메뉴 건너뛰기




Volumn 110, Issue 1-4, 2004, Pages 579-586

BNCT microdosimetry at the tapiro reactor thermal column

Author keywords

[No Author keywords available]

Indexed keywords

BORON 10; POLYETHYLENE;

EID: 4644281703     PISSN: 01448420     EISSN: None     Source Type: Journal    
DOI: 10.1093/rpd/nch206     Document Type: Article
Times cited : (13)

References (12)
  • 1
    • 4644287931 scopus 로고    scopus 로고
    • SPES project study of an advanced facility for exotic beams at LNL
    • LNL report. LNL-INFN (REP) 145/99 Laboratori Nazional di Leguaro viale dell' Universita, I-35020, Italy
    • Stepharini, A., et al. SPES project study of an advanced facility for exotic beams at LNL. LNL report, LNL-INFN (REP) 145/99 (1999) Laboratori Nazional di Leguaro viale dell' Universita, I-35020, Italy.
    • (1999)
    • Stepharini, A.1
  • 2
    • 0036133337 scopus 로고    scopus 로고
    • Characterisation of an accelerator-based neutron source for BNCT versus beam energy
    • Agosteo, S., Curzio, G., d'Errico, F., Nath, R. and Tinti, R., Characterisation of an accelerator-based neutron source for BNCT versus beam energy. Nucl. Instrum. Meth. A 476, 106-112 (2002).
    • (2002) Nucl. Instrum. Meth. A , vol.476 , pp. 106-112
    • Agosteo, S.1    Curzio, G.2    d'Errico, F.3    Nath, R.4    Tinti, R.5
  • 4
    • 0034806317 scopus 로고    scopus 로고
    • Miniature tissue-equivalent proportional counters for BNCT and BNCEFNT dosimetry
    • Burmeister, J., Kota, C., Maughan, R. L. and Waker, A. J. Miniature tissue-equivalent proportional counters for BNCT and BNCEFNT dosimetry. Med. Phys. 28, 1911-1925 (2001).
    • (2001) Med. Phys. , vol.28 , pp. 1911-1925
    • Burmeister, J.1    Kota, C.2    Maughan, R.L.3    Waker, A.J.4
  • 10
    • 0028313985 scopus 로고
    • Radiobiological effectiveness of radiation beams with broad LET spectra: Microdosimetric analysis using biological weighting functions
    • Loncol, T., Cosgrove, V., Denis, J. M., Gueulette, J., Mazal, A., Menzel, H. G., Pihet, P. and Sabattier, R. Radiobiological effectiveness of radiation beams with broad LET spectra: microdosimetric analysis using biological weighting functions. Radiat. Prot. Dosim. 52, 347-352 (1994).
    • (1994) Radiat. Prot. Dosim. , vol.52 , pp. 347-352
    • Loncol, T.1    Cosgrove, V.2    Denis, J.M.3    Gueulette, J.4    Mazal, A.5    Menzel, H.G.6    Pihet, P.7    Sabattier, R.8
  • 11
    • 0022010766 scopus 로고
    • Experimental uncertainties in microdosimetric measurements and an examination of the performancy of three commercially produced proportional counters
    • Waker, A. J. Experimental uncertainties in microdosimetric measurements and an examination of the performancy of three commercially produced proportional counters. Nucl. Instrum. Meth. A 234, 354-360 (1985).
    • (1985) Nucl. Instrum. Meth. A , vol.234 , pp. 354-360
    • Waker, A.J.1
  • 12
    • 4644353865 scopus 로고    scopus 로고
    • Statistical and overall uncertainties in BNCT microdosimetric measurements
    • Laboratori di Legnaro report, LNL-INFN(REP) 199/2003
    • Seravalli, E. and Colautti, P. Statistical and overall uncertainties in BNCT microdosimetric measurements. Laboratori di Legnaro report, LNL-INFN(REP) 199/2003 (2003).
    • (2003)
    • Seravalli, E.1    Colautti, P.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.