Volumn 28, Issue 9, 2001, Pages 1911-1925

Miniature tissue-equivalent proportional counters for BNCT and BNCEFNT dosimetry

Author keywords

BNCEFNT tissue equivalent proportional counters; BNCT; Dosimetry; Microdosimetry

Indexed keywords

BORON; CHARGED PARTICLES; DOSIMETRY; PROPORTIONAL COUNTERS; TISSUE;

EID: 0034806317     PISSN: 00942405     EISSN: None     Source Type: Journal    
DOI: 10.1118/1.1398303     Document Type: Article
Times cited : (26)

References (76)
  • 3
    • 0000605030 scopus 로고
    • The uses of nuclear disintegration in the diagnosis and treatment of brain tumor
    • (1951) N. Engl. J. Med. , vol.245 , pp. 875-878
    • Sweet, W.H.1
  • 4
    • 0344354577 scopus 로고
    • The possible use of neutron-capturing isotopes such as boron-10 in the treatment of neoplasms. I. Intracranial tumors
    • (1952) J. Neurosurg. , vol.9 , pp. 200-209
    • Sweet, W.H.1    Javid, M.2
  • 9
    • 0025895856 scopus 로고
    • A history of boron neutron capture therapy of brain tumors
    • (1991) Brain , vol.114 , pp. 1609-1629
    • Slatkin, D.N.1
  • 44
    • 0034122435 scopus 로고    scopus 로고
    • Use of low pressure tissue equivalent proportional counters for dosimetry in BNCT and BNCEFNT
    • (2000) Med. Phys. , vol.27 , pp. 535-548
    • Kota, C.1    Maughan, R.L.2
  • 46
    • 0015107602 scopus 로고
    • Considerations on the random traversal of convex bodies and solutions for general cylinders
    • (1971) Radiat. Res. , vol.47 , pp. 359-376
    • Kellerer, A.M.1
  • 48
    • 0019472904 scopus 로고
    • Criteria for the equivalence of spherical and cylindrical proportional counters in microdosimetry
    • (1981) Radiat. Res. , vol.86 , pp. 277-286
    • Kellerer, A.M.1
  • 59
    • 0004183119 scopus 로고
    • ICRU #36. (International Commission on Radiation Units and Measurements, Bethesda, MD)
    • (1983) Microdosimetry
  • 63
    • 0000792876 scopus 로고
    • Note on the Bragg-Gray cavity principle for measuring energy dissipation
    • (1954) Radiat. Res. , vol.1 , pp. 237-240
    • Fano, U.1
  • 66
    • 0022010766 scopus 로고
    • Experimental uncertainties in microdosimetric measurements and an examination of the performance of three commercially produced proportional counters
    • (1985) Nucl. Instrum. Methods Phys. Res. A , vol.234 , pp. 354-360
    • Waker, A.J.1
  • 67
    • 0025204645 scopus 로고
    • Microdosimetry at middle age: Some old experimental problems and new aspirations
    • (1990) Radiat. Res. , vol.124
    • Kliauga, P.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.