메뉴 건너뛰기




Volumn 16, Issue 3, 2007, Pages 471-492

Preoperative Imaging for Metastasectomy

Author keywords

[No Author keywords available]

Indexed keywords

1,4,7,10 TETRAAZACYCLODODECANE 1,4,7,10 TETRAACETIC ACID; CONTRAST MEDIUM; FLUORINE 18; GADOLINIUM; YTTRIUM 90;

EID: 34347258905     PISSN: 10553207     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.soc.2007.04.004     Document Type: Review
Times cited : (3)

References (138)
  • 1
    • 0017332281 scopus 로고
    • Detection of pulmonary nodules by computed tomography
    • Muhm J.R., Brown L.R., and Crowe J.K. Detection of pulmonary nodules by computed tomography. AJR Am J Roentgenol 128 2 (1977) 267-270
    • (1977) AJR Am J Roentgenol , vol.128 , Issue.2 , pp. 267-270
    • Muhm, J.R.1    Brown, L.R.2    Crowe, J.K.3
  • 2
    • 12144261858 scopus 로고    scopus 로고
    • Detection of pulmonary nodules at multirow-detector CT: effectiveness of double reading to improve sensitivity at standard-dose and low-dose chest CT
    • Wormanns D., Ludwig K., Beyer F., et al. Detection of pulmonary nodules at multirow-detector CT: effectiveness of double reading to improve sensitivity at standard-dose and low-dose chest CT. Eur Radiol 15 1 (2005) 14-22
    • (2005) Eur Radiol , vol.15 , Issue.1 , pp. 14-22
    • Wormanns, D.1    Ludwig, K.2    Beyer, F.3
  • 3
    • 8644226203 scopus 로고    scopus 로고
    • The feasibility of low-dose CT for pulmonary metastasis in patients with primary gynecologic malignancy
    • Weng M.J., Wu M.T., Pan H.B., et al. The feasibility of low-dose CT for pulmonary metastasis in patients with primary gynecologic malignancy. Clin Imaging 28 6 (2004) 408-414
    • (2004) Clin Imaging , vol.28 , Issue.6 , pp. 408-414
    • Weng, M.J.1    Wu, M.T.2    Pan, H.B.3
  • 4
    • 0027245609 scopus 로고
    • Pulmonary nodules: detection with thick-section spiral CT versus conventional CT
    • Remy-Jardin M., Remy J., Giraud F., et al. Pulmonary nodules: detection with thick-section spiral CT versus conventional CT. Radiology 187 2 (1993) 513-520
    • (1993) Radiology , vol.187 , Issue.2 , pp. 513-520
    • Remy-Jardin, M.1    Remy, J.2    Giraud, F.3
  • 5
    • 0028279872 scopus 로고
    • Spiral CT of the lungs: optimal technique and resolution compared with conventional CT
    • Paranjpe D.V., and Bergin C.J. Spiral CT of the lungs: optimal technique and resolution compared with conventional CT. AJR Am J Roentgenol 162 3 (1994) 561-567
    • (1994) AJR Am J Roentgenol , vol.162 , Issue.3 , pp. 561-567
    • Paranjpe, D.V.1    Bergin, C.J.2
  • 6
    • 0029122713 scopus 로고
    • Pulmonary nodules: effect of increased data sampling on detection with spiral CT and confidence in diagnosis
    • Buckley J.A., Scott Jr. W.W., Siegelman S.S., et al. Pulmonary nodules: effect of increased data sampling on detection with spiral CT and confidence in diagnosis. Radiology 196 2 (1995) 395-400
    • (1995) Radiology , vol.196 , Issue.2 , pp. 395-400
    • Buckley, J.A.1    Scott Jr., W.W.2    Siegelman, S.S.3
  • 7
    • 0032909316 scopus 로고    scopus 로고
    • Helical CT of pulmonary nodules in patients with extrathoracic malignancy
    • Diederich S., Semik M., Lentschig M.G., et al. Helical CT of pulmonary nodules in patients with extrathoracic malignancy. AJR Am J Roentgenol 172 (1999) 353-360
    • (1999) AJR Am J Roentgenol , vol.172 , pp. 353-360
    • Diederich, S.1    Semik, M.2    Lentschig, M.G.3
  • 8
    • 9344261777 scopus 로고    scopus 로고
    • Accuracy of helical CT in the detection of pulmonary metastases: is intraoperative palpation still necessary?
    • [discussion: 1916-8]
    • Parsons A.M., Detterbeck F.C., and Parker L.A. Accuracy of helical CT in the detection of pulmonary metastases: is intraoperative palpation still necessary?. Ann Thorac Surg 78 6 (2004) 1910-1916 [discussion: 1916-8]
    • (2004) Ann Thorac Surg , vol.78 , Issue.6 , pp. 1910-1916
    • Parsons, A.M.1    Detterbeck, F.C.2    Parker, L.A.3
  • 9
    • 30344459729 scopus 로고    scopus 로고
    • Computed tomographic scan of the chest underestimates the number of metastatic lesions in osteosarcoma
    • Kayton M.L., Huvos A.G., Casher J., et al. Computed tomographic scan of the chest underestimates the number of metastatic lesions in osteosarcoma. J Pediatr Surg 41 (2006) 200-206
    • (2006) J Pediatr Surg , vol.41 , pp. 200-206
    • Kayton, M.L.1    Huvos, A.G.2    Casher, J.3
  • 10
    • 0031304611 scopus 로고    scopus 로고
    • Detection of pulmonary nodules with helical CT: comparison of cine and film-based viewing
    • Tillich M., Kammerhuber F., Reittner P., et al. Detection of pulmonary nodules with helical CT: comparison of cine and film-based viewing. AJR Am J Roentgenol 169 (1997) 1611-1614
    • (1997) AJR Am J Roentgenol , vol.169 , pp. 1611-1614
    • Tillich, M.1    Kammerhuber, F.2    Reittner, P.3
  • 11
    • 0036280811 scopus 로고    scopus 로고
    • Incremental benefit of maximum-intensity-projection images on observer detection of small pulmonary nodules revealed by multidetector CT
    • Gruden J.F., Ouanounou S., Tigges S., et al. Incremental benefit of maximum-intensity-projection images on observer detection of small pulmonary nodules revealed by multidetector CT. AJR Am J Roentgenol 179 (2002) 149-157
    • (2002) AJR Am J Roentgenol , vol.179 , pp. 149-157
    • Gruden, J.F.1    Ouanounou, S.2    Tigges, S.3
  • 12
    • 31444447203 scopus 로고    scopus 로고
    • Value of axial and coronal maximum intensity projection (MIP) images in the detection of pulmonary nodules by multislice spiral CT: comparison with axial 1-mm and 5-mm slices
    • Valencia R., Denecke T., Lehmkuhl L., et al. Value of axial and coronal maximum intensity projection (MIP) images in the detection of pulmonary nodules by multislice spiral CT: comparison with axial 1-mm and 5-mm slices. Eur Radiol 16 (2006) 325-332
    • (2006) Eur Radiol , vol.16 , pp. 325-332
    • Valencia, R.1    Denecke, T.2    Lehmkuhl, L.3
  • 13
    • 10644262269 scopus 로고    scopus 로고
    • Pulmonary nodules on multi-detector row CT scans: performance comparison of radiologists and computer-aided detection
    • Rubin G.D., Lyo J.K., Paik D.S., et al. Pulmonary nodules on multi-detector row CT scans: performance comparison of radiologists and computer-aided detection. Radiology 234 (2005) 274-283
    • (2005) Radiology , vol.234 , pp. 274-283
    • Rubin, G.D.1    Lyo, J.K.2    Paik, D.S.3
  • 14
    • 3142743079 scopus 로고    scopus 로고
    • Diagnostic performance of a commercially available computer-aided diagnosis system for automatic detection of pulmonary nodules: comparison with single and double reading
    • Wormanns D., Beyer F., Diederich S., et al. Diagnostic performance of a commercially available computer-aided diagnosis system for automatic detection of pulmonary nodules: comparison with single and double reading. Rofo 176 7 (2004) 953-958
    • (2004) Rofo , vol.176 , Issue.7 , pp. 953-958
    • Wormanns, D.1    Beyer, F.2    Diederich, S.3
  • 15
    • 20744443150 scopus 로고    scopus 로고
    • Automated detection of pulmonary nodules on CT images: effect of section thickness and reconstruction interval-initial results
    • Kim J.S., Kim J.H., Cho G., et al. Automated detection of pulmonary nodules on CT images: effect of section thickness and reconstruction interval-initial results. Radiology 236 (2005) 295-299
    • (2005) Radiology , vol.236 , pp. 295-299
    • Kim, J.S.1    Kim, J.H.2    Cho, G.3
  • 16
    • 30444440310 scopus 로고    scopus 로고
    • Automated detection of lung nodules in multidetector CT: influence of different reconstruction protocols on performance of a software prototype
    • Gurung J., Maataoui A., Khan M., et al. Automated detection of lung nodules in multidetector CT: influence of different reconstruction protocols on performance of a software prototype. Rofo 178 1 (2006) 71-77
    • (2006) Rofo , vol.178 , Issue.1 , pp. 71-77
    • Gurung, J.1    Maataoui, A.2    Khan, M.3
  • 17
    • 7044231339 scopus 로고    scopus 로고
    • The potential contribution of a computer-aided detection system for lung nodule detection in multidetector row computed tomography
    • Lee J.W., Goo J.M., Lee H.J., et al. The potential contribution of a computer-aided detection system for lung nodule detection in multidetector row computed tomography. Invest Radiol 39 (2004) 649-655
    • (2004) Invest Radiol , vol.39 , pp. 649-655
    • Lee, J.W.1    Goo, J.M.2    Lee, H.J.3
  • 18
    • 33745558637 scopus 로고    scopus 로고
    • Computer-aided detection in screening CT for pulmonary nodules
    • Yuan R., Vos P.M., and Cooperberg P.L. Computer-aided detection in screening CT for pulmonary nodules. AJR Am J Roentgenol 18 (2006) 1280-1287
    • (2006) AJR Am J Roentgenol , vol.18 , pp. 1280-1287
    • Yuan, R.1    Vos, P.M.2    Cooperberg, P.L.3
  • 19
    • 20744460878 scopus 로고    scopus 로고
    • Pulmonary nodules: automated detection on CT images with morphologic matching algorithm-preliminary results
    • Bae K.T., Kim J.S., Na Y.H., et al. Pulmonary nodules: automated detection on CT images with morphologic matching algorithm-preliminary results. Radiology 236 (2005) 286-294
    • (2005) Radiology , vol.236 , pp. 286-294
    • Bae, K.T.1    Kim, J.S.2    Na, Y.H.3
  • 20
    • 0033962497 scopus 로고    scopus 로고
    • Lung nodule enhancement at CT: multicenter study
    • Swensen S.J., Viggiano R.W., Midthun D.E., et al. Lung nodule enhancement at CT: multicenter study. Radiology 214 (2000) 73-80
    • (2000) Radiology , vol.214 , pp. 73-80
    • Swensen, S.J.1    Viggiano, R.W.2    Midthun, D.E.3
  • 21
    • 33646913058 scopus 로고    scopus 로고
    • Inherent variability of CT lung nodule measurements in vivo using semiautomated volumetric measurements
    • Goodman L.R., Gulsun M., Washington L., et al. Inherent variability of CT lung nodule measurements in vivo using semiautomated volumetric measurements. AJR Am J Roentgenol 186 (2006) 989-994
    • (2006) AJR Am J Roentgenol , vol.186 , pp. 989-994
    • Goodman, L.R.1    Gulsun, M.2    Washington, L.3
  • 22
    • 2142697951 scopus 로고    scopus 로고
    • Are two-dimensional CT measurements of small noncalcified pulmonary nodules reliable?
    • Revel M.P., Bissery A., Bienvenu M., et al. Are two-dimensional CT measurements of small noncalcified pulmonary nodules reliable?. Radiology 231 (2004) 453-458
    • (2004) Radiology , vol.231 , pp. 453-458
    • Revel, M.P.1    Bissery, A.2    Bienvenu, M.3
  • 23
    • 2142812310 scopus 로고    scopus 로고
    • Small pulmonary nodules: reproducibility of three-dimensional volumetric measurement and estimation of time to follow-up CT
    • Kostis W.J., Yankelevitz D.F., Reeves A.P., et al. Small pulmonary nodules: reproducibility of three-dimensional volumetric measurement and estimation of time to follow-up CT. Radiology 231 (2004) 446-452
    • (2004) Radiology , vol.231 , pp. 446-452
    • Kostis, W.J.1    Yankelevitz, D.F.2    Reeves, A.P.3
  • 24
    • 0035925107 scopus 로고    scopus 로고
    • Accuracy of positron emission tomography for diagnosis of pulmonary nodules and mass lesions: a meta-analysis
    • Gould M.K., Maclean C.C., Kuschner W.G., et al. Accuracy of positron emission tomography for diagnosis of pulmonary nodules and mass lesions: a meta-analysis. JAMA 285 7 (2001) 914-924
    • (2001) JAMA , vol.285 , Issue.7 , pp. 914-924
    • Gould, M.K.1    Maclean, C.C.2    Kuschner, W.G.3
  • 25
    • 33747105270 scopus 로고    scopus 로고
    • Integrating PET and CT information to improve diagnostic accuracy for lung nodules: a semiautomatic computer-aided method
    • Nie Y., Li Q., Li F., et al. Integrating PET and CT information to improve diagnostic accuracy for lung nodules: a semiautomatic computer-aided method. J Nucl Med 47 (2006) 1075-1080
    • (2006) J Nucl Med , vol.47 , pp. 1075-1080
    • Nie, Y.1    Li, Q.2    Li, F.3
  • 26
    • 31044448696 scopus 로고    scopus 로고
    • Nodal involvement at the time of pulmonary metastasectomy: experiences in 245 patients
    • Pfannschmidt J., Klode J., Muley T., et al. Nodal involvement at the time of pulmonary metastasectomy: experiences in 245 patients. Ann Thorac Surg 81 (2006) 448-454
    • (2006) Ann Thorac Surg , vol.81 , pp. 448-454
    • Pfannschmidt, J.1    Klode, J.2    Muley, T.3
  • 27
    • 1942436741 scopus 로고    scopus 로고
    • Prognostic significance of lymph node metastasis found during pulmonary metastasectomy for extrapulmonary carcinoma
    • Ercan S., Nichols F.C., Trastek V.F., et al. Prognostic significance of lymph node metastasis found during pulmonary metastasectomy for extrapulmonary carcinoma. Ann Thorac Surg 77 (2004) 1786-1791
    • (2004) Ann Thorac Surg , vol.77 , pp. 1786-1791
    • Ercan, S.1    Nichols, F.C.2    Trastek, V.F.3
  • 28
    • 32944456177 scopus 로고    scopus 로고
    • Detection of pulmonary nodules using a 2D HASTE MR sequence: comparison with MDCT
    • Schroeder T., Ruehm S.G., Debatin J.F., et al. Detection of pulmonary nodules using a 2D HASTE MR sequence: comparison with MDCT. AJR Am J Roentgenol 185 (2005) 979-984
    • (2005) AJR Am J Roentgenol , vol.185 , pp. 979-984
    • Schroeder, T.1    Ruehm, S.G.2    Debatin, J.F.3
  • 29
    • 33644981802 scopus 로고    scopus 로고
    • IV contrast for MDTC: current thoughts and practice
    • Johnson P.T., and Fishman E.K. IV contrast for MDTC: current thoughts and practice. AJR Am J Roentgenol 186 (2006) 406-415
    • (2006) AJR Am J Roentgenol , vol.186 , pp. 406-415
    • Johnson, P.T.1    Fishman, E.K.2
  • 30
    • 0031757970 scopus 로고    scopus 로고
    • Liver lesions: improved detection with dual-detector-array CT and routine 2.5-mm thin collimation
    • Weg N., Scheer M.R., and Gabor M.P. Liver lesions: improved detection with dual-detector-array CT and routine 2.5-mm thin collimation. Radiology 209 (1998) 417-426
    • (1998) Radiology , vol.209 , pp. 417-426
    • Weg, N.1    Scheer, M.R.2    Gabor, M.P.3
  • 31
    • 0036787351 scopus 로고    scopus 로고
    • Multi-detector row helical CT in preoperative assessment of small (≤1.5 cm) liver metastases: Is thinner collimation better?
    • Haider M.A., Amitai M.M., Rappaport D.C., et al. Multi-detector row helical CT in preoperative assessment of small (≤1.5 cm) liver metastases: Is thinner collimation better?. Radiology 225 (2002) 137-142
    • (2002) Radiology , vol.225 , pp. 137-142
    • Haider, M.A.1    Amitai, M.M.2    Rappaport, D.C.3
  • 32
    • 4944236265 scopus 로고    scopus 로고
    • Prospective study of contrast-enhanced computed tomography, computed tomography during arterioportography, and magnetic resonance imaging for staging colorectal liver metastases for liver resection
    • Bhattacharjya S., Bhattacharjya T., Baber S., et al. Prospective study of contrast-enhanced computed tomography, computed tomography during arterioportography, and magnetic resonance imaging for staging colorectal liver metastases for liver resection. Br J Surg 91 (2004) 1361-1369
    • (2004) Br J Surg , vol.91 , pp. 1361-1369
    • Bhattacharjya, S.1    Bhattacharjya, T.2    Baber, S.3
  • 33
    • 0032956637 scopus 로고    scopus 로고
    • Hepatic lesion detection: comparison of MR imaging after the administration of superparamagnetic iron oxide with dual-phase CT by using alternative-free response receiver operating characteristic analysis
    • Ward J., Naik K.S., Guthrie J.A., et al. Hepatic lesion detection: comparison of MR imaging after the administration of superparamagnetic iron oxide with dual-phase CT by using alternative-free response receiver operating characteristic analysis. Radiology 210 (1999) 459-466
    • (1999) Radiology , vol.210 , pp. 459-466
    • Ward, J.1    Naik, K.S.2    Guthrie, J.A.3
  • 34
    • 0034546354 scopus 로고    scopus 로고
    • Hepatic lesion detection and characterization: value of nonenhanced MR imaging, superparamagnetic iron oxide-enhanced MR imaging, and spiral CT: ROC analysis
    • Reimer P., Jahnke N., Fiebich M., et al. Hepatic lesion detection and characterization: value of nonenhanced MR imaging, superparamagnetic iron oxide-enhanced MR imaging, and spiral CT: ROC analysis. Radiology 217 (2000) 152-158
    • (2000) Radiology , vol.217 , pp. 152-158
    • Reimer, P.1    Jahnke, N.2    Fiebich, M.3
  • 35
    • 0036239057 scopus 로고    scopus 로고
    • Characterization of liver lesion with mangafodipir trisodium-enhanced MR imaging: multicenter study comparing MR and dual-phase spiral CT
    • Oudkerk M., Torres C.G., Song B., et al. Characterization of liver lesion with mangafodipir trisodium-enhanced MR imaging: multicenter study comparing MR and dual-phase spiral CT. Radiology 223 (2002) 517-524
    • (2002) Radiology , vol.223 , pp. 517-524
    • Oudkerk, M.1    Torres, C.G.2    Song, B.3
  • 36
    • 1942469293 scopus 로고    scopus 로고
    • Small (≤2 cm) hepatic lesions in colorectal cancer patients: detection and characterization on mangafodipir trisodium-enhanced MRI
    • Kim K.W., Kim A.Y., Kim T.K., et al. Small (≤2 cm) hepatic lesions in colorectal cancer patients: detection and characterization on mangafodipir trisodium-enhanced MRI. AJR Am J Roentgenol 182 (2004) 1233-1240
    • (2004) AJR Am J Roentgenol , vol.182 , pp. 1233-1240
    • Kim, K.W.1    Kim, A.Y.2    Kim, T.K.3
  • 37
    • 2142825027 scopus 로고    scopus 로고
    • Detection of hypovascular hepatic metastases at triple-phase helical CT: sensitivity of phases and comparison with surgical and histopathologic findings
    • Soyer P., Poccard M., Boudiaf M., et al. Detection of hypovascular hepatic metastases at triple-phase helical CT: sensitivity of phases and comparison with surgical and histopathologic findings. Radiology 231 (2004) 413-420
    • (2004) Radiology , vol.231 , pp. 413-420
    • Soyer, P.1    Poccard, M.2    Boudiaf, M.3
  • 38
    • 25144432834 scopus 로고    scopus 로고
    • Liver metastases in candidates for hepatic resection: comparison of helical CT and gadolinium- and SPIO- enhanced MR imaging
    • Ward J., Robinson P.J., Guthrie J.A., et al. Liver metastases in candidates for hepatic resection: comparison of helical CT and gadolinium- and SPIO- enhanced MR imaging. Radiology 237 (2005) 170-180
    • (2005) Radiology , vol.237 , pp. 170-180
    • Ward, J.1    Robinson, P.J.2    Guthrie, J.A.3
  • 39
    • 33746238709 scopus 로고    scopus 로고
    • Characterization of small liver lesions: added role of MR after MDCT
    • Holalkere N.S., Sahani D.V., Blake M.A., et al. Characterization of small liver lesions: added role of MR after MDCT. J Comput Assist Tomogr 30 4 (2006) 591-596
    • (2006) J Comput Assist Tomogr , vol.30 , Issue.4 , pp. 591-596
    • Holalkere, N.S.1    Sahani, D.V.2    Blake, M.A.3
  • 40
    • 18744389130 scopus 로고    scopus 로고
    • Preoperative assessment of focal liver lesions: multidetector computed tomography challenges magnetic resonance imaging
    • Numminen K., Isoniemi H., Halavaara J., et al. Preoperative assessment of focal liver lesions: multidetector computed tomography challenges magnetic resonance imaging. Acta Radiol 46 1 (2005) 9-15
    • (2005) Acta Radiol , vol.46 , Issue.1 , pp. 9-15
    • Numminen, K.1    Isoniemi, H.2    Halavaara, J.3
  • 41
    • 33645122604 scopus 로고    scopus 로고
    • Hepatic metastases: detection with multi-detector row CT, SPIO-enhanced MR imaging, and both techniques combined
    • Onishi H., Murakami T., Kim T., et al. Hepatic metastases: detection with multi-detector row CT, SPIO-enhanced MR imaging, and both techniques combined. Radiology 239 1 (2006) 131-138
    • (2006) Radiology , vol.239 , Issue.1 , pp. 131-138
    • Onishi, H.1    Murakami, T.2    Kim, T.3
  • 42
    • 0042932352 scopus 로고    scopus 로고
    • Colorectal hepatic metastases: detection with SPIO-enhanced breath-hold MR imaging: comparison of optimized sequences
    • Ward J., Guthrie J.A., Wilson D., et al. Colorectal hepatic metastases: detection with SPIO-enhanced breath-hold MR imaging: comparison of optimized sequences. Radiology 228 (2003) 709-718
    • (2003) Radiology , vol.228 , pp. 709-718
    • Ward, J.1    Guthrie, J.A.2    Wilson, D.3
  • 43
    • 33745966057 scopus 로고    scopus 로고
    • New MR techniques for the detection of liver metastases
    • Ward J. New MR techniques for the detection of liver metastases. Cancer Imaging 6 (2006) 33-42
    • (2006) Cancer Imaging , vol.6 , pp. 33-42
    • Ward, J.1
  • 44
    • 12544252337 scopus 로고    scopus 로고
    • Detection of liver metastases: gadobenate dimeglumine-enhanced three-dimensional dynamic phases and one-hour delayed phase MR imaging versus superparamagnetic iron oxide-enhanced MR imaging
    • Kim Y.K., Lee J.M., Kim C.S., et al. Detection of liver metastases: gadobenate dimeglumine-enhanced three-dimensional dynamic phases and one-hour delayed phase MR imaging versus superparamagnetic iron oxide-enhanced MR imaging. Eur Radiol 15 2 (2005) 220-228
    • (2005) Eur Radiol , vol.15 , Issue.2 , pp. 220-228
    • Kim, Y.K.1    Lee, J.M.2    Kim, C.S.3
  • 45
    • 33646191521 scopus 로고    scopus 로고
    • Mangafodipir trisodium-enhanced MRI for the detection and characterization of focal hepatic lesions: is delayed imaging useful?
    • Chung J.J., Kim M.J., and Kim K.W. Mangafodipir trisodium-enhanced MRI for the detection and characterization of focal hepatic lesions: is delayed imaging useful?. J Magn Reson Imaging 23 5 (2006) 706-711
    • (2006) J Magn Reson Imaging , vol.23 , Issue.5 , pp. 706-711
    • Chung, J.J.1    Kim, M.J.2    Kim, K.W.3
  • 46
    • 0842280679 scopus 로고    scopus 로고
    • Detection of colorectal liver metastases: a prospective multicenter trial comparing unenhanced MRI, MnDPDP-enhanced MRI, and spiral CT
    • Bartolozzi C., Donati F., Cioni D., et al. Detection of colorectal liver metastases: a prospective multicenter trial comparing unenhanced MRI, MnDPDP-enhanced MRI, and spiral CT. Eur Radiol 14 (2004) 14-20
    • (2004) Eur Radiol , vol.14 , pp. 14-20
    • Bartolozzi, C.1    Donati, F.2    Cioni, D.3
  • 47
    • 0038756513 scopus 로고    scopus 로고
    • Preoperative evaluation of malignant liver tumors: comparison of unenhanced and SPIO (Resovist)-enhanced MR imaging with biphasic CTAP and intraoperative US
    • Vogl T.J., Schwarz W., and Blume S. Preoperative evaluation of malignant liver tumors: comparison of unenhanced and SPIO (Resovist)-enhanced MR imaging with biphasic CTAP and intraoperative US. Eur Radiol 13 (2003) 262-272
    • (2003) Eur Radiol , vol.13 , pp. 262-272
    • Vogl, T.J.1    Schwarz, W.2    Blume, S.3
  • 48
    • 2142771281 scopus 로고    scopus 로고
    • Evaluation of hepatic metastases from colorectal carcinoma with MR-superparamagnetic iron oxide
    • Vidiri A., Carpanese L., D'Annibale M., et al. Evaluation of hepatic metastases from colorectal carcinoma with MR-superparamagnetic iron oxide. J Exp Clin Cancer Res 23 1 (2004) 53-60
    • (2004) J Exp Clin Cancer Res , vol.23 , Issue.1 , pp. 53-60
    • Vidiri, A.1    Carpanese, L.2    D'Annibale, M.3
  • 49
    • 0036893501 scopus 로고    scopus 로고
    • Detection of liver metastases: comparison of gadobenate dimeglumine-enhanced and ferumoxides-enhanced MR imaging examinations
    • Del Frate C., Bazzocchi M., and Mortele K.J. Detection of liver metastases: comparison of gadobenate dimeglumine-enhanced and ferumoxides-enhanced MR imaging examinations. Radiology 225 (2002) 766-772
    • (2002) Radiology , vol.225 , pp. 766-772
    • Del Frate, C.1    Bazzocchi, M.2    Mortele, K.J.3
  • 50
    • 10344235969 scopus 로고    scopus 로고
    • Magnetic resonance imaging of focal liver lesions: comparison of the superparamagnetic iron oxide resovist versus gadolinium-DTPA in the same patient
    • Vogl T.J., Hammerstingl R., Schwarz W., et al. Magnetic resonance imaging of focal liver lesions: comparison of the superparamagnetic iron oxide resovist versus gadolinium-DTPA in the same patient. Invest Radiol 31 11 (1996) 696-708
    • (1996) Invest Radiol , vol.31 , Issue.11 , pp. 696-708
    • Vogl, T.J.1    Hammerstingl, R.2    Schwarz, W.3
  • 51
    • 4744367361 scopus 로고    scopus 로고
    • Detection and characterization of focal hepatic lesions: mangafodipir vs. superparamagnetic iron oxide-enhanced magnetic resonance imaging
    • Kim M.J., Kim J.H., Lim J.S., et al. Detection and characterization of focal hepatic lesions: mangafodipir vs. superparamagnetic iron oxide-enhanced magnetic resonance imaging. J Magn Reson Imaging 20 4 (2004) 612-621
    • (2004) J Magn Reson Imaging , vol.20 , Issue.4 , pp. 612-621
    • Kim, M.J.1    Kim, J.H.2    Lim, J.S.3
  • 52
    • 33748693499 scopus 로고    scopus 로고
    • Detection of hepatic metastasis: manganese- and ferucarbotran-enhanced MR imaging
    • Choi J.Y., Kim M.J., and Kim J.H. Detection of hepatic metastasis: manganese- and ferucarbotran-enhanced MR imaging. Eur J Radiol 60 1 (2006) 84-90
    • (2006) Eur J Radiol , vol.60 , Issue.1 , pp. 84-90
    • Choi, J.Y.1    Kim, M.J.2    Kim, J.H.3
  • 53
    • 33646911995 scopus 로고    scopus 로고
    • Comparison of mangafodipir trisodium- and ferucarbotran-enhanced MRI for detection and characterization of hepatic metastases in colorectal cancer patients
    • Kim H.J., Kim K.W., Byun J.H., et al. Comparison of mangafodipir trisodium- and ferucarbotran-enhanced MRI for detection and characterization of hepatic metastases in colorectal cancer patients. AJR Am J Roentgenol 186 (2006) 1059-1066
    • (2006) AJR Am J Roentgenol , vol.186 , pp. 1059-1066
    • Kim, H.J.1    Kim, K.W.2    Byun, J.H.3
  • 54
    • 0036739169 scopus 로고    scopus 로고
    • Ferumoxide-enhanced magnetic resonance imaging techniques in pre-operative assessment for colorectal liver metastases
    • van Etten B., van der Sijp J.R.M., Kruyt R.H., et al. Ferumoxide-enhanced magnetic resonance imaging techniques in pre-operative assessment for colorectal liver metastases. Eur J Surg Oncol 28 (2002) 645-651
    • (2002) Eur J Surg Oncol , vol.28 , pp. 645-651
    • van Etten, B.1    van der Sijp, J.R.M.2    Kruyt, R.H.3
  • 55
    • 0032886084 scopus 로고    scopus 로고
    • Liver metastases: comparison of current MR techniques and spiral CT during arterial portography for detection in 20 surgically staged cases
    • Semelka R.C., Cance W.G., Marcos H.B., et al. Liver metastases: comparison of current MR techniques and spiral CT during arterial portography for detection in 20 surgically staged cases. Radiology 312 1 (1999) 86-91
    • (1999) Radiology , vol.312 , Issue.1 , pp. 86-91
    • Semelka, R.C.1    Cance, W.G.2    Marcos, H.B.3
  • 56
    • 33745486962 scopus 로고    scopus 로고
    • Comparison of CT during arterial portography and MR during arterial portography in the detection of liver metastases
    • Hosch W.P., Schmidt S.M., and Plaza S. Comparison of CT during arterial portography and MR during arterial portography in the detection of liver metastases. AJR Am J Roentgenol 186 (2006) 1502-1511
    • (2006) AJR Am J Roentgenol , vol.186 , pp. 1502-1511
    • Hosch, W.P.1    Schmidt, S.M.2    Plaza, S.3
  • 57
    • 0035002837 scopus 로고    scopus 로고
    • What is the yield of intraoperative ultrasonography during partial hepatectomy for malignant disease?
    • Jarnagin W.R., Bach A.M., Winston C.B., et al. What is the yield of intraoperative ultrasonography during partial hepatectomy for malignant disease?. J Am Coll Surg 192 (2001) 577-583
    • (2001) J Am Coll Surg , vol.192 , pp. 577-583
    • Jarnagin, W.R.1    Bach, A.M.2    Winston, C.B.3
  • 58
    • 0008731371 scopus 로고    scopus 로고
    • Current value of intraoperative sonography during surgery for hepatic neoplams
    • Zacherl J., Scheuba C., Imhof M., et al. Current value of intraoperative sonography during surgery for hepatic neoplams. World J Surg 26 (2002) 550-554
    • (2002) World J Surg , vol.26 , pp. 550-554
    • Zacherl, J.1    Scheuba, C.2    Imhof, M.3
  • 59
    • 31844433217 scopus 로고    scopus 로고
    • Potential value of contrast-enhanced intraoperative ultrasonography during partial hepatectomy for metastases
    • Leen E., Ceccotti P., Moug S.J., et al. Potential value of contrast-enhanced intraoperative ultrasonography during partial hepatectomy for metastases. Ann Surg 243 (2006) 236-240
    • (2006) Ann Surg , vol.243 , pp. 236-240
    • Leen, E.1    Ceccotti, P.2    Moug, S.J.3
  • 60
    • 0036721291 scopus 로고    scopus 로고
    • Detection of hepatic metastases from cancers of the gastrointestinal tract by using noninvasive imaging methods (US, CT, MR imaging, PET): a meta-analysis
    • Kinkel K., Lu Y., Both M., et al. Detection of hepatic metastases from cancers of the gastrointestinal tract by using noninvasive imaging methods (US, CT, MR imaging, PET): a meta-analysis. Radiology 224 (2002) 748-756
    • (2002) Radiology , vol.224 , pp. 748-756
    • Kinkel, K.1    Lu, Y.2    Both, M.3
  • 61
    • 15944429402 scopus 로고    scopus 로고
    • 18F]fluoro-2-deoxy-D-glucose positron emission tomography of resectable colorectal liver metastases
    • 18F]fluoro-2-deoxy-D-glucose positron emission tomography of resectable colorectal liver metastases. Br J Surg 92 (2005) 362-369
    • (2005) Br J Surg , vol.92 , pp. 362-369
    • Truant, S.1    Huglo, D.2    Hebbar, M.3
  • 62
    • 33846614119 scopus 로고    scopus 로고
    • Comparison of multiphase CT, FDG-PET and intra-operative ultrasound in patients with colorectal liver metastases selected for surgery
    • Wiering B., Ruers T.J.M., Krabbe P.F.M., et al. Comparison of multiphase CT, FDG-PET and intra-operative ultrasound in patients with colorectal liver metastases selected for surgery. Ann Surg Oncol 14 2 (2007) 818-826
    • (2007) Ann Surg Oncol , vol.14 , Issue.2 , pp. 818-826
    • Wiering, B.1    Ruers, T.J.M.2    Krabbe, P.F.M.3
  • 63
    • 17144423534 scopus 로고    scopus 로고
    • Detectability of liver metastases in malignant melanoma: prospective comparison of magnetic resonance imaging and positron emission tomography
    • Ghanem N., Altehoefer C., Hogerle S., et al. Detectability of liver metastases in malignant melanoma: prospective comparison of magnetic resonance imaging and positron emission tomography. Eur J Radiol 54 2 (2005) 264-270
    • (2005) Eur J Radiol , vol.54 , Issue.2 , pp. 264-270
    • Ghanem, N.1    Altehoefer, C.2    Hogerle, S.3
  • 64
    • 24644441861 scopus 로고    scopus 로고
    • Detection of liver metastases from adenocarcinoma of the colon and pancreas: comparison of mangafodipir trisodium-enhanced liver MRI and whole-body FDG PET
    • Sahani D.V., Kalva S.P., Fischman A.J., et al. Detection of liver metastases from adenocarcinoma of the colon and pancreas: comparison of mangafodipir trisodium-enhanced liver MRI and whole-body FDG PET. AJR Am J Roentgenol 185 (2005) 239-246
    • (2005) AJR Am J Roentgenol , vol.185 , pp. 239-246
    • Sahani, D.V.1    Kalva, S.P.2    Fischman, A.J.3
  • 65
    • 33644747712 scopus 로고    scopus 로고
    • Assessment of the extent of metastases of gastrointestinal carcinoid tumors using whole-body PET, CT, MRI, PET/CT and PET/MRI
    • Seemann M.D., Meisetschlaeger G., Gaa G., et al. Assessment of the extent of metastases of gastrointestinal carcinoid tumors using whole-body PET, CT, MRI, PET/CT and PET/MRI. Eur J Med Res 11 2 (2006) 58-65
    • (2006) Eur J Med Res , vol.11 , Issue.2 , pp. 58-65
    • Seemann, M.D.1    Meisetschlaeger, G.2    Gaa, G.3
  • 66
    • 28044445671 scopus 로고    scopus 로고
    • High-resolution whole- body magnetic resonance image tumor staging with the use of parallel imaging versus dual-modality positron emission tomography-computed tomography
    • Schmidt G.P., Baur-Melnyk A., Herzog P., et al. High-resolution whole- body magnetic resonance image tumor staging with the use of parallel imaging versus dual-modality positron emission tomography-computed tomography. Invest Radiol 40 (2005) 743-753
    • (2005) Invest Radiol , vol.40 , pp. 743-753
    • Schmidt, G.P.1    Baur-Melnyk, A.2    Herzog, P.3
  • 67
    • 0014326195 scopus 로고
    • On the prevalence of adrenocortical adenomas in an autopsy material in relation to hypertension and diabetes
    • Hedeland H., Ostberg G., and Hokfelt B. On the prevalence of adrenocortical adenomas in an autopsy material in relation to hypertension and diabetes. Acta Med Scand 184 3 (1968) 211-214
    • (1968) Acta Med Scand , vol.184 , Issue.3 , pp. 211-214
    • Hedeland, H.1    Ostberg, G.2    Hokfelt, B.3
  • 68
    • 31144436265 scopus 로고    scopus 로고
    • Distinguishing benign from malignant adrenal masses: multi-detector row CT Protocol with 10-minute delay
    • Blake M.A., Kalra M.K., Sweeney A., et al. Distinguishing benign from malignant adrenal masses: multi-detector row CT Protocol with 10-minute delay. Radiology 238 2 (2006) 578-586
    • (2006) Radiology , vol.238 , Issue.2 , pp. 578-586
    • Blake, M.A.1    Kalra, M.K.2    Sweeney, A.3
  • 69
    • 0036186857 scopus 로고    scopus 로고
    • Adrenal masses: characterization with combined unenhanced and delayed enhanced CT
    • Caoili E.M., Korobkin M., Francis I.R., et al. Adrenal masses: characterization with combined unenhanced and delayed enhanced CT. Radiology 222 (2002) 629-633
    • (2002) Radiology , vol.222 , pp. 629-633
    • Caoili, E.M.1    Korobkin, M.2    Francis, I.R.3
  • 70
    • 0030059558 scopus 로고    scopus 로고
    • Differentiation of adrenal adenomas from nonadenomas using CT attenuation values
    • Korobkin M., Brodeur F.J., Yutzy G.G., et al. Differentiation of adrenal adenomas from nonadenomas using CT attenuation values. AJR Am J Roentgenol 166 3 (1996) 531-536
    • (1996) AJR Am J Roentgenol , vol.166 , Issue.3 , pp. 531-536
    • Korobkin, M.1    Brodeur, F.J.2    Yutzy, G.G.3
  • 71
    • 0031832517 scopus 로고    scopus 로고
    • Characterization of adrenal masses using unenhanced CT: an analysis of the CT literature
    • Boland G.W., Lee M.J., Gazelle G.S., et al. Characterization of adrenal masses using unenhanced CT: an analysis of the CT literature. AJR Am J Roentgenol 171 1 (1998) 201-204
    • (1998) AJR Am J Roentgenol , vol.171 , Issue.1 , pp. 201-204
    • Boland, G.W.1    Lee, M.J.2    Gazelle, G.S.3
  • 72
    • 33644846085 scopus 로고    scopus 로고
    • Value of chemical shift subtraction MRI in characterization of adrenal masses
    • Savci G., Yazici Z., Sahin N., et al. Value of chemical shift subtraction MRI in characterization of adrenal masses. AJR Am J Roentgenol 186 (2006) 130-135
    • (2006) AJR Am J Roentgenol , vol.186 , pp. 130-135
    • Savci, G.1    Yazici, Z.2    Sahin, N.3
  • 73
    • 0027476070 scopus 로고
    • Adrenal masses: differentiation with chemical shift, fast low-angle shot MR imaging
    • Tsushima Y., Ishizaka H., and Matsumoto M. Adrenal masses: differentiation with chemical shift, fast low-angle shot MR imaging. Radiology 186 (1993) 705-709
    • (1993) Radiology , vol.186 , pp. 705-709
    • Tsushima, Y.1    Ishizaka, H.2    Matsumoto, M.3
  • 74
    • 2442667852 scopus 로고    scopus 로고
    • Chemical shift MR imaging of hyperattenuating (>10 HU) adrenal masses: does it still have a role?
    • Haider M.A., Ghai S., Jhaveri K., et al. Chemical shift MR imaging of hyperattenuating (>10 HU) adrenal masses: does it still have a role?. Radiology 231 (2004) 711-716
    • (2004) Radiology , vol.231 , pp. 711-716
    • Haider, M.A.1    Ghai, S.2    Jhaveri, K.3
  • 75
    • 0035542957 scopus 로고    scopus 로고
    • 18F-FDG PET in characterizing adrenal lesions detected on CT or MRI
    • 18F-FDG PET in characterizing adrenal lesions detected on CT or MRI. J Nucl Med 42 (2001) 1795-1799
    • (2001) J Nucl Med , vol.42 , pp. 1795-1799
    • Yun, M.1    Kim, W.2    Alnafisi, N.3
  • 76
    • 0033042067 scopus 로고    scopus 로고
    • Imaging of adrenal tumors using FDG PET: comparison of benign and malignant lesions
    • Maurea S., Mainolfi C., Bazzicalupo L., et al. Imaging of adrenal tumors using FDG PET: comparison of benign and malignant lesions. AJR Am J Roentgenol 173 (1999) 25-29
    • (1999) AJR Am J Roentgenol , vol.173 , pp. 25-29
    • Maurea, S.1    Mainolfi, C.2    Bazzicalupo, L.3
  • 77
    • 0028950485 scopus 로고
    • Indeterminate adrenal mass in patients with cancer: evaluation at PET with 2-[F-18]-fluoro-2-deoxy-D-glucose
    • Boland G.W., Goldberg M.A., Lee M.J., et al. Indeterminate adrenal mass in patients with cancer: evaluation at PET with 2-[F-18]-fluoro-2-deoxy-D-glucose. Radiology 194 (1995) 131-134
    • (1995) Radiology , vol.194 , pp. 131-134
    • Boland, G.W.1    Goldberg, M.A.2    Lee, M.J.3
  • 78
    • 33344455256 scopus 로고    scopus 로고
    • Adrenal lesions: characterization with fused PET/CT image in patients with proved or suspected malignancy: initial experience
    • Blake M.A., Slattery J.M., Kalra M.K., et al. Adrenal lesions: characterization with fused PET/CT image in patients with proved or suspected malignancy: initial experience. Radiology 238 3 (2006) 970-977
    • (2006) Radiology , vol.238 , Issue.3 , pp. 970-977
    • Blake, M.A.1    Slattery, J.M.2    Kalra, M.K.3
  • 79
    • 29144504049 scopus 로고    scopus 로고
    • The impact of Fluor-18-deoxyglucose-positron emission tomography in the management of colorectal liver metastases
    • Wiering B., Krabbe P.F.M., Jager G.J., et al. The impact of Fluor-18-deoxyglucose-positron emission tomography in the management of colorectal liver metastases. Cancer 104 (2005) 2658-2670
    • (2005) Cancer , vol.104 , pp. 2658-2670
    • Wiering, B.1    Krabbe, P.F.M.2    Jager, G.J.3
  • 80
    • 33846587472 scopus 로고    scopus 로고
    • The role of FDG-PET in the selection of patients with colorectal liver metastases
    • Wiering B., Krabbe P.F.M., Dekker H.M., et al. The role of FDG-PET in the selection of patients with colorectal liver metastases. Ann Surg Oncol 2 14 (2007) 771-779
    • (2007) Ann Surg Oncol , vol.2 , Issue.14 , pp. 771-779
    • Wiering, B.1    Krabbe, P.F.M.2    Dekker, H.M.3
  • 81
    • 4344615981 scopus 로고    scopus 로고
    • Five-year survival after resection of hepatic metastases from colorectal cancer in patients screened by positron emission tomography with F-18 Fluorodeoxyglucose (FDG-PET)
    • Fernandez F.G., Drebin J.A., Linehan D.C., et al. Five-year survival after resection of hepatic metastases from colorectal cancer in patients screened by positron emission tomography with F-18 Fluorodeoxyglucose (FDG-PET). Ann Surg 240 (2004) 438-450
    • (2004) Ann Surg , vol.240 , pp. 438-450
    • Fernandez, F.G.1    Drebin, J.A.2    Linehan, D.C.3
  • 82
    • 0031912655 scopus 로고    scopus 로고
    • Utility of FDG-PET for Investigating unexplained plasma CEA elevation in patients with colorectal cancer
    • Flanagan F.L., Dehdashti F., Ogunbiyi O.A., et al. Utility of FDG-PET for Investigating unexplained plasma CEA elevation in patients with colorectal cancer. Ann Surg 227 3 (1998) 319-323
    • (1998) Ann Surg , vol.227 , Issue.3 , pp. 319-323
    • Flanagan, F.L.1    Dehdashti, F.2    Ogunbiyi, O.A.3
  • 83
    • 0034093915 scopus 로고    scopus 로고
    • Usefulness of FDG-PET scan in the assessment of suspected metastatic or recurrent adenocarcinoma of the colon and rectum
    • [discussion: 767-70]
    • Whiteford M.H., Whiteford H.M., Yee L.F., et al. Usefulness of FDG-PET scan in the assessment of suspected metastatic or recurrent adenocarcinoma of the colon and rectum. Dis Colon Rectum 43 6 (2000) 759-767 [discussion: 767-70]
    • (2000) Dis Colon Rectum , vol.43 , Issue.6 , pp. 759-767
    • Whiteford, M.H.1    Whiteford, H.M.2    Yee, L.F.3
  • 85
    • 6944247966 scopus 로고    scopus 로고
    • A prospective analysis of positron emission tomography and conventional imaging for detection of stage IV metastatic melanoma in patients undergoing metastasectomy
    • Finkelstein S.E., Carrasquillo J.A., Hoffman J.M., et al. A prospective analysis of positron emission tomography and conventional imaging for detection of stage IV metastatic melanoma in patients undergoing metastasectomy. Ann Surg Oncol 11 8 (2004) 731-738
    • (2004) Ann Surg Oncol , vol.11 , Issue.8 , pp. 731-738
    • Finkelstein, S.E.1    Carrasquillo, J.A.2    Hoffman, J.M.3
  • 86
    • 0036340383 scopus 로고    scopus 로고
    • Positron emission tomography is superior to computed tomography for metastatic detection in melanoma patients
    • 646-3
    • Swetter S.M., Carroll L.A., Johnson D.L., et al. Positron emission tomography is superior to computed tomography for metastatic detection in melanoma patients. Ann Surg Oncol 9 7 (2002) 646-3
    • (2002) Ann Surg Oncol , vol.9 , Issue.7
    • Swetter, S.M.1    Carroll, L.A.2    Johnson, D.L.3
  • 87
    • 31144433548 scopus 로고    scopus 로고
    • Prospective comparison of the impact on treatment decisions of whole-body magnetic resonance imaging and computed tomography in patients with metastatic malignant melanoma
    • Muller-Horvat C., Radny P., Eigentler T.K., et al. Prospective comparison of the impact on treatment decisions of whole-body magnetic resonance imaging and computed tomography in patients with metastatic malignant melanoma. Eur J Cancer 42 3 (2006) 342-350
    • (2006) Eur J Cancer , vol.42 , Issue.3 , pp. 342-350
    • Muller-Horvat, C.1    Radny, P.2    Eigentler, T.K.3
  • 88
    • 33846587851 scopus 로고    scopus 로고
    • 18F-fluorodeoxyglucose positron emission tomography/computed tomography and whole-body magnetic resonance imaging in staging of advanced malignant melanoma
    • 18F-fluorodeoxyglucose positron emission tomography/computed tomography and whole-body magnetic resonance imaging in staging of advanced malignant melanoma. Eur J Cancer 43 (2007) 557-564
    • (2007) Eur J Cancer , vol.43 , pp. 557-564
    • Pfannenberg, C.1    Aschoff, P.2    Schanz, S.3
  • 89
    • 33644975843 scopus 로고    scopus 로고
    • 18F-FDG PET/C imaging for N- and M- staging of malignant melanoma: experience with 250 consecutive patients
    • 18F-FDG PET/C imaging for N- and M- staging of malignant melanoma: experience with 250 consecutive patients. J Clin Oncol 24 (2006) 1178-1187
    • (2006) J Clin Oncol , vol.24 , pp. 1178-1187
    • Reinhardt, M.J.1    Joe, A.Y.2    Jaeger, U.3
  • 90
    • 0032887728 scopus 로고    scopus 로고
    • Liver metastases from melanoma: detection with multiphasic contrast-enhanced CT
    • Blake S.P., Weisinger K., Atkins M.B., et al. Liver metastases from melanoma: detection with multiphasic contrast-enhanced CT. Radiology 213 1 (1999) 92-96
    • (1999) Radiology , vol.213 , Issue.1 , pp. 92-96
    • Blake, S.P.1    Weisinger, K.2    Atkins, M.B.3
  • 91
    • 4344679124 scopus 로고    scopus 로고
    • Recent advances in radiological and radionuclide imaging and therapy of neuroendocrine tumours
    • Kaltsas G., Rockall A., Papadogias D., et al. Recent advances in radiological and radionuclide imaging and therapy of neuroendocrine tumours. Eur J Endocrinol 151 (2004) 15-27
    • (2004) Eur J Endocrinol , vol.151 , pp. 15-27
    • Kaltsas, G.1    Rockall, A.2    Papadogias, D.3
  • 92
    • 0030982511 scopus 로고    scopus 로고
    • False-negative fluorine-18-FDG PET in metastatic carcinoid
    • Jadvar H., and Segall G.M. False-negative fluorine-18-FDG PET in metastatic carcinoid. J Nucl Med 38 9 (1997) 1382-1383
    • (1997) J Nucl Med , vol.38 , Issue.9 , pp. 1382-1383
    • Jadvar, H.1    Segall, G.M.2
  • 93
    • 0035991806 scopus 로고    scopus 로고
    • Fluorodeoxyglucose positron emission tomography and somatostatin receptor scintigraphy for diagnosing and staging carcinoid tumours: correlations with the pathological indexes p53 and Ki-67
    • Belhocine T., Foidart J., Rigo P., et al. Fluorodeoxyglucose positron emission tomography and somatostatin receptor scintigraphy for diagnosing and staging carcinoid tumours: correlations with the pathological indexes p53 and Ki-67. Nucl Med Commun 23 8 (2002) 727-734
    • (2002) Nucl Med Commun , vol.23 , Issue.8 , pp. 727-734
    • Belhocine, T.1    Foidart, J.2    Rigo, P.3
  • 95
    • 0038037897 scopus 로고    scopus 로고
    • Benefit of anatomical-functional image fusion in the diagnostic work-up of neuroendocrine neoplasms
    • Pfannenberg A.C., Eschmann S.M., Horger M., et al. Benefit of anatomical-functional image fusion in the diagnostic work-up of neuroendocrine neoplasms. Eur J Nucl Med Mol Imaging 30 (2003) 835-843
    • (2003) Eur J Nucl Med Mol Imaging , vol.30 , pp. 835-843
    • Pfannenberg, A.C.1    Eschmann, S.M.2    Horger, M.3
  • 96
    • 0141855166 scopus 로고    scopus 로고
    • CT, endoscopic sonography, and a combined protocol for preoperative evaluation of pancreatic insulinomas
    • Gouya H., Vignaux O., Augui J., et al. CT, endoscopic sonography, and a combined protocol for preoperative evaluation of pancreatic insulinomas. AJR Am J Roentgenol 181 (2003) 987-992
    • (2003) AJR Am J Roentgenol , vol.181 , pp. 987-992
    • Gouya, H.1    Vignaux, O.2    Augui, J.3
  • 97
    • 0031929995 scopus 로고    scopus 로고
    • Carcinoid metastases to the liver: role of triple-phase helical CT
    • Paulson E.K., McDermott V.G., Keogan M.T., et al. Carcinoid metastases to the liver: role of triple-phase helical CT. Radiology 206 (1998) 143-150
    • (1998) Radiology , vol.206 , pp. 143-150
    • Paulson, E.K.1    McDermott, V.G.2    Keogan, M.T.3
  • 98
    • 16644375649 scopus 로고    scopus 로고
    • Detection of liver metastases from endocrine tumors: a prospective comparison of somatostatin receptor scintigraphy, computed tomography, and magnetic resonance imaging
    • Dromain C., de Baere T., Lumbroso J., et al. Detection of liver metastases from endocrine tumors: a prospective comparison of somatostatin receptor scintigraphy, computed tomography, and magnetic resonance imaging. J Clin Oncol 23 (2005) 70-78
    • (2005) J Clin Oncol , vol.23 , pp. 70-78
    • Dromain, C.1    de Baere, T.2    Lumbroso, J.3
  • 100
    • 21244471142 scopus 로고    scopus 로고
    • 11C-5-hydroxytryptophan positron emission tomography as a universal imaging technique for neuroendocrine tumors: comparison with somatostatin receptor scintigraphy and computed tomography
    • 11C-5-hydroxytryptophan positron emission tomography as a universal imaging technique for neuroendocrine tumors: comparison with somatostatin receptor scintigraphy and computed tomography. J Clin Endocrinol Metab 90 6 (2005) 3392-3400
    • (2005) J Clin Endocrinol Metab , vol.90 , Issue.6 , pp. 3392-3400
    • Orlefors, H.1    Sundin, A.2    Garske, U.3
  • 101
    • 4043130985 scopus 로고    scopus 로고
    • Imaging of advanced neuroendocrine tumors with 18F-FDOPA PET
    • Becherer A., Szabo M., Karanikas G., et al. Imaging of advanced neuroendocrine tumors with 18F-FDOPA PET. J Nucl Med 45 7 (2004) 1161-1167
    • (2004) J Nucl Med , vol.45 , Issue.7 , pp. 1161-1167
    • Becherer, A.1    Szabo, M.2    Karanikas, G.3
  • 102
    • 33748746832 scopus 로고    scopus 로고
    • F-FDG PET and PET/CT for detection of pulmonary metastases from musculoskeletal sarcomas
    • Iagaru A., Chawla S., Menendez L., et al. F-FDG PET and PET/CT for detection of pulmonary metastases from musculoskeletal sarcomas. Nucl Med Commun 27 (2006) 795-802
    • (2006) Nucl Med Commun , vol.27 , pp. 795-802
    • Iagaru, A.1    Chawla, S.2    Menendez, L.3
  • 103
    • 1442284854 scopus 로고    scopus 로고
    • Roles of positron emission tomography with fluorine-18-deoxyglucose in the detection of local recurrent and distant metastatic sarcoma
    • Johnson G.R., Zhuang H., Khan J., et al. Roles of positron emission tomography with fluorine-18-deoxyglucose in the detection of local recurrent and distant metastatic sarcoma. Clin Nucl Med 28 (2003) 815-820
    • (2003) Clin Nucl Med , vol.28 , pp. 815-820
    • Johnson, G.R.1    Zhuang, H.2    Khan, J.3
  • 104
    • 0034979190 scopus 로고    scopus 로고
    • Whole-body MR imaging for detection of bone metastases in children and young adults: comparison with skeletal scintigraphy and FDG PET
    • Daldrup-Link H., Franzius C., Link T.M., et al. Whole-body MR imaging for detection of bone metastases in children and young adults: comparison with skeletal scintigraphy and FDG PET. AJR Am J Roentgenol 177 (2001) 229-236
    • (2001) AJR Am J Roentgenol , vol.177 , pp. 229-236
    • Daldrup-Link, H.1    Franzius, C.2    Link, T.M.3
  • 105
    • 33748432697 scopus 로고    scopus 로고
    • Is PET useful in detecting occult nonpulmonary metastases in pediatric bone sarcomas?
    • Kneisl J.S., Patt J.C., and Johnson J.C. Is PET useful in detecting occult nonpulmonary metastases in pediatric bone sarcomas?. Clin Orthop Relat Res 450 (2006) 101-104
    • (2006) Clin Orthop Relat Res , vol.450 , pp. 101-104
    • Kneisl, J.S.1    Patt, J.C.2    Johnson, J.C.3
  • 106
    • 0027275167 scopus 로고
    • Evaluation of computed tomography in patients with peritoneal carcinomatosis
    • Jacquet P., Jelinek J.S., Steves M.A., et al. Evaluation of computed tomography in patients with peritoneal carcinomatosis. Cancer 72 5 (1993) 1631-1636
    • (1993) Cancer , vol.72 , Issue.5 , pp. 1631-1636
    • Jacquet, P.1    Jelinek, J.S.2    Steves, M.A.3
  • 107
    • 2342639688 scopus 로고    scopus 로고
    • Peritoneal carcinomatosis from colorectal or appendiceal origin: correlation of preoperative CT with intraopertaive findings and evaluation of interobserver agreement
    • De Bree E., Koops W., Kroger R., et al. Peritoneal carcinomatosis from colorectal or appendiceal origin: correlation of preoperative CT with intraopertaive findings and evaluation of interobserver agreement. J Surg Oncol 86 (2004) 64-73
    • (2004) J Surg Oncol , vol.86 , pp. 64-73
    • De Bree, E.1    Koops, W.2    Kroger, R.3
  • 108
    • 33845411633 scopus 로고    scopus 로고
    • Surgical strategies for gastric cancer with synchronous peritoneal carcinomatosis
    • Gretschel S., Siegel R., Estevez-Schwarz L., et al. Surgical strategies for gastric cancer with synchronous peritoneal carcinomatosis. Br J Surg 93 (2006) 1530-1535
    • (2006) Br J Surg , vol.93 , pp. 1530-1535
    • Gretschel, S.1    Siegel, R.2    Estevez-Schwarz, L.3
  • 109
    • 0027952984 scopus 로고
    • Computerized tomography of the abdomen and pelvis with peritoneal administration of soluble contrast (IPC-CT) in detection of residual disease for patients with ovarian cancer
    • Frasci G., Contino A., Iaffaioli R.V., et al. Computerized tomography of the abdomen and pelvis with peritoneal administration of soluble contrast (IPC-CT) in detection of residual disease for patients with ovarian cancer. Gynecol Oncol 52 2 (1994) 154-160
    • (1994) Gynecol Oncol , vol.52 , Issue.2 , pp. 154-160
    • Frasci, G.1    Contino, A.2    Iaffaioli, R.V.3
  • 110
    • 0028909316 scopus 로고
    • Induced pneumoperitoneum in CT evaluation of peritoneal carcinomatosis
    • [discussion: 56-7]
    • Caseiro-Alves F., Goncalo M., Abraul E., et al. Induced pneumoperitoneum in CT evaluation of peritoneal carcinomatosis. Abdom Imaging 20 1 (1995) 52-55 [discussion: 56-7]
    • (1995) Abdom Imaging , vol.20 , Issue.1 , pp. 52-55
    • Caseiro-Alves, F.1    Goncalo, M.2    Abraul, E.3
  • 111
    • 0031784728 scopus 로고    scopus 로고
    • Intraperitoneal contrast material combined with CT for detection of peritoneal metastases of ovarian cancer
    • Gryspeerdt S., Clabout L., Van Hoe L., et al. Intraperitoneal contrast material combined with CT for detection of peritoneal metastases of ovarian cancer. Eur J Gynaecol Oncol 19 5 (1998) 434-437
    • (1998) Eur J Gynaecol Oncol , vol.19 , Issue.5 , pp. 434-437
    • Gryspeerdt, S.1    Clabout, L.2    Van Hoe, L.3
  • 112
    • 0036233925 scopus 로고    scopus 로고
    • Peritoneal metastases: detection with spiral CT in patients with ovarian cancer
    • Coakley F.V., Choi P.H., Gougoutas C.A., et al. Peritoneal metastases: detection with spiral CT in patients with ovarian cancer. Radiology 223 (2002) 495-499
    • (2002) Radiology , vol.223 , pp. 495-499
    • Coakley, F.V.1    Choi, P.H.2    Gougoutas, C.A.3
  • 113
    • 0037484045 scopus 로고    scopus 로고
    • Thin section dual-phase multidetector-row computed tomography detection of peritoneal metastases in gynecologic cancers
    • Pannu H.K., Horton K.M., and Fishman E.K. Thin section dual-phase multidetector-row computed tomography detection of peritoneal metastases in gynecologic cancers. J Comput Assist Tomogr 27 3 (2003) 333-340
    • (2003) J Comput Assist Tomogr , vol.27 , Issue.3 , pp. 333-340
    • Pannu, H.K.1    Horton, K.M.2    Fishman, E.K.3
  • 114
    • 12344325535 scopus 로고    scopus 로고
    • Role of CT and MR imaging in predicting optimal cytoreduction of newly diagnosed primary epithelial ovarian cancer
    • Qayyum A., Coakley F.V., Westphalen A.C., et al. Role of CT and MR imaging in predicting optimal cytoreduction of newly diagnosed primary epithelial ovarian cancer. Gynecol Oncol 96 (2005) 301-306
    • (2005) Gynecol Oncol , vol.96 , pp. 301-306
    • Qayyum, A.1    Coakley, F.V.2    Westphalen, A.C.3
  • 115
    • 3042823262 scopus 로고    scopus 로고
    • The utility of computed tomography scans in predicting suboptimal cytoreductive surgery in women with advanced ovarian carcinoma
    • Dowdy S.C., Mullany S.A., Brandt K.R., et al. The utility of computed tomography scans in predicting suboptimal cytoreductive surgery in women with advanced ovarian carcinoma. Cancer 101 (2004) 346-352
    • (2004) Cancer , vol.101 , pp. 346-352
    • Dowdy, S.C.1    Mullany, S.A.2    Brandt, K.R.3
  • 116
    • 30844454419 scopus 로고    scopus 로고
    • Preoperative computed tomography and selection of patients with colorectal peritoneal carcinomatosis for cytoreductive surgery and hyperthermic intraperitoneal chemotherapy
    • de Bree E., Koops W., Kroger R., et al. Preoperative computed tomography and selection of patients with colorectal peritoneal carcinomatosis for cytoreductive surgery and hyperthermic intraperitoneal chemotherapy. Eur J Surg Oncol 32 (2006) 65-71
    • (2006) Eur J Surg Oncol , vol.32 , pp. 65-71
    • de Bree, E.1    Koops, W.2    Kroger, R.3
  • 117
    • 13444252267 scopus 로고    scopus 로고
    • Abdominal computed tomography scans in the selection of patients with malignant peritoneal mesothelioma for comprehensive treatment with cytoreductive surgery and perioperative intraperitoneal chemotherapy
    • Yan T.D., Haveric N., and Carmignani C.P. Abdominal computed tomography scans in the selection of patients with malignant peritoneal mesothelioma for comprehensive treatment with cytoreductive surgery and perioperative intraperitoneal chemotherapy. Cancer 103 (2005) 839-849
    • (2005) Cancer , vol.103 , pp. 839-849
    • Yan, T.D.1    Haveric, N.2    Carmignani, C.P.3
  • 118
    • 0034078236 scopus 로고    scopus 로고
    • Staging of advanced ovarian cancer: comparison of imaging modalities: report from the Radiological Diagnostic Oncology Group
    • Tempany C.M.C., Zou K.H., and Silverman S.G. Staging of advanced ovarian cancer: comparison of imaging modalities: report from the Radiological Diagnostic Oncology Group. Radiology 215 (2000) 761-767
    • (2000) Radiology , vol.215 , pp. 761-767
    • Tempany, C.M.C.1    Zou, K.H.2    Silverman, S.G.3
  • 119
    • 0032976594 scopus 로고    scopus 로고
    • Extrahepatic abdominal imaging in patients with malignancy: comparison of MR imaging and helical CT, with subsequent surgical correlation
    • Low R.N., Semelka R.C., Worawattanakul S., et al. Extrahepatic abdominal imaging in patients with malignancy: comparison of MR imaging and helical CT, with subsequent surgical correlation. Radiology 210 (1999) 625-632
    • (1999) Radiology , vol.210 , pp. 625-632
    • Low, R.N.1    Semelka, R.C.2    Worawattanakul, S.3
  • 120
    • 33751160841 scopus 로고    scopus 로고
    • MRI evaluation of bulky tumor masses in the mesentery and bladder involvement in peritoneal carcinomatosis
    • Cotton F., Pellet O., Gilly F.N., et al. MRI evaluation of bulky tumor masses in the mesentery and bladder involvement in peritoneal carcinomatosis. Eur J Surg Oncol 32 (2006) 1212-1216
    • (2006) Eur J Surg Oncol , vol.32 , pp. 1212-1216
    • Cotton, F.1    Pellet, O.2    Gilly, F.N.3
  • 121
    • 0030797016 scopus 로고    scopus 로고
    • Peritoneal tumor: MR imaging with dilute oral barium and intravenous gadolinium-containing contrast agents compared with unenhanced MR imaging and CT
    • Low R.N., Barone R.M., Lacey C., et al. Peritoneal tumor: MR imaging with dilute oral barium and intravenous gadolinium-containing contrast agents compared with unenhanced MR imaging and CT. Radiology 204 (1997) 513-520
    • (1997) Radiology , vol.204 , pp. 513-520
    • Low, R.N.1    Barone, R.M.2    Lacey, C.3
  • 122
    • 0036873692 scopus 로고    scopus 로고
    • Abdominal recurrence of ovarian cancer: value of abdominal MR in patients with positive CA 125 and negative CT
    • Balestreri L., Bison L., Sorio R., et al. Abdominal recurrence of ovarian cancer: value of abdominal MR in patients with positive CA 125 and negative CT. Radiol Med (Torino) 104 5-6 (2002) 426-436
    • (2002) Radiol Med (Torino) , vol.104 , Issue.5-6 , pp. 426-436
    • Balestreri, L.1    Bison, L.2    Sorio, R.3
  • 123
    • 1642289329 scopus 로고    scopus 로고
    • Rectal cancer: mesorectal lymph nodes at MR imaging with USPIO versus histopathologic findings: initial observations
    • Koh D.M., Brown G., Temple L., et al. Rectal cancer: mesorectal lymph nodes at MR imaging with USPIO versus histopathologic findings: initial observations. Radiology 231 1 (2004) 91-99
    • (2004) Radiology , vol.231 , Issue.1 , pp. 91-99
    • Koh, D.M.1    Brown, G.2    Temple, L.3
  • 124
    • 0042932291 scopus 로고    scopus 로고
    • Evaluation of neck and body metastases to nodes with ferumoxtran 10-enhanced MR imaging: phase III safety and efficacy study
    • Anzai Y., Piccoli C.W., Outwater E.K., et al. Evaluation of neck and body metastases to nodes with ferumoxtran 10-enhanced MR imaging: phase III safety and efficacy study. Radiology 228 3 (2003) 777-788
    • (2003) Radiology , vol.228 , Issue.3 , pp. 777-788
    • Anzai, Y.1    Piccoli, C.W.2    Outwater, E.K.3
  • 125
    • 33646585820 scopus 로고    scopus 로고
    • Lymphotropic nanoparticle enhanced MR imaging (LNMRI) technique for lymph node imaging
    • Saksena M.A., Saokar A., and Harisinghani M.G. Lymphotropic nanoparticle enhanced MR imaging (LNMRI) technique for lymph node imaging. Eur J Radiol 58 (2006) 367-374
    • (2006) Eur J Radiol , vol.58 , pp. 367-374
    • Saksena, M.A.1    Saokar, A.2    Harisinghani, M.G.3
  • 126
    • 33845456610 scopus 로고    scopus 로고
    • Comparison of CT and 18F-FDG PET for detecting peritoneal metastasis on the preoperative evaluation for gastric carcinoma
    • Lim J.S., Kim M.J., Yun M.J., et al. Comparison of CT and 18F-FDG PET for detecting peritoneal metastasis on the preoperative evaluation for gastric carcinoma. Korean J Radiol 7 4 (2006) 249-256
    • (2006) Korean J Radiol , vol.7 , Issue.4 , pp. 249-256
    • Lim, J.S.1    Kim, M.J.2    Yun, M.J.3
  • 127
    • 0042744048 scopus 로고    scopus 로고
    • Positron emission tomography with FDG in the detection of peritoneal and retroperitoneal metastases of ovarian cancer
    • Drieskens O., Stroobants S., Gysen M., et al. Positron emission tomography with FDG in the detection of peritoneal and retroperitoneal metastases of ovarian cancer. Gynecol Obstet Invest 55 3 (2003) 130-134
    • (2003) Gynecol Obstet Invest , vol.55 , Issue.3 , pp. 130-134
    • Drieskens, O.1    Stroobants, S.2    Gysen, M.3
  • 128
    • 2342620155 scopus 로고    scopus 로고
    • PET-CT detection of abdominal recurrence of ovarian cancer: radiologic-surgical correlation
    • Pannu H.K., Cohade C., Bristow R.E., et al. PET-CT detection of abdominal recurrence of ovarian cancer: radiologic-surgical correlation. Abdom Imaging 39 (2004) 398-403
    • (2004) Abdom Imaging , vol.39 , pp. 398-403
    • Pannu, H.K.1    Cohade, C.2    Bristow, R.E.3
  • 129
    • 0142212380 scopus 로고    scopus 로고
    • Peritoneal carcinomatosis role of (18) F-FDG PET
    • Turlakow A., Yeung H., Walmon H.W., et al. Peritoneal carcinomatosis role of (18) F-FDG PET. J Nucl Med 44 9 (2003) 1407-1412
    • (2003) J Nucl Med , vol.44 , Issue.9 , pp. 1407-1412
    • Turlakow, A.1    Yeung, H.2    Walmon, H.W.3
  • 130
    • 5444250962 scopus 로고    scopus 로고
    • Value of 18F-FDG PET in the detection of peritoneal carcinomatosis
    • Suzuki A., Kawano T., Takahashi N., et al. Value of 18F-FDG PET in the detection of peritoneal carcinomatosis. Eur J Nucl Med Mol Imaging 31 10 (2004) 1413-1420
    • (2004) Eur J Nucl Med Mol Imaging , vol.31 , Issue.10 , pp. 1413-1420
    • Suzuki, A.1    Kawano, T.2    Takahashi, N.3
  • 131
    • 12444321927 scopus 로고    scopus 로고
    • Advanced ovarian carcinoma: usefulness of [(18)F] FDG-PET in combination with CT for lesion detection after primary treatment
    • Picchio M., Sironi S., Messa C., et al. Advanced ovarian carcinoma: usefulness of [(18)F] FDG-PET in combination with CT for lesion detection after primary treatment. Q J Nucl Med 47 (2003) 77-84
    • (2003) Q J Nucl Med , vol.47 , pp. 77-84
    • Picchio, M.1    Sironi, S.2    Messa, C.3
  • 132
    • 33846913995 scopus 로고    scopus 로고
    • The diagnostic value of PET-CT for peritoneal dissemination of abdominal malignancies
    • Yang Q.M., Bando E., Kawamura T., et al. The diagnostic value of PET-CT for peritoneal dissemination of abdominal malignancies. Gan To Kagaku Ryoho 33 12 (2006) 1817-1821
    • (2006) Gan To Kagaku Ryoho , vol.33 , Issue.12 , pp. 1817-1821
    • Yang, Q.M.1    Bando, E.2    Kawamura, T.3
  • 133
    • 7044232022 scopus 로고    scopus 로고
    • Integrated FDG PET/CT in patients with persistent ovarian cancer: correlation with histologic findings
    • Sironi S., essa C., Mangili G., et al. Integrated FDG PET/CT in patients with persistent ovarian cancer: correlation with histologic findings. Radiology 233 (2004) 433-440
    • (2004) Radiology , vol.233 , pp. 433-440
    • Sironi, S.1    essa, C.2    Mangili, G.3
  • 134
    • 0141974973 scopus 로고    scopus 로고
    • Clinically occult recurrent ovarian cancer: patient selection for secondary cytoreductive surgery using combined PET/CT
    • Bristow R.E., del Carmen M.G., Pannu H.K., et al. Clinically occult recurrent ovarian cancer: patient selection for secondary cytoreductive surgery using combined PET/CT. Gynecol Oncol 90 (2003) 519-528
    • (2003) Gynecol Oncol , vol.90 , pp. 519-528
    • Bristow, R.E.1    del Carmen, M.G.2    Pannu, H.K.3
  • 135
    • 15544384862 scopus 로고    scopus 로고
    • FDG-PET for management of cervical and ovarian cancer
    • Havrilesky L.J., Kulasingam S.L., Matchar D.B., et al. FDG-PET for management of cervical and ovarian cancer. Gynecol Oncol 97 (2005) 183-191
    • (2005) Gynecol Oncol , vol.97 , pp. 183-191
    • Havrilesky, L.J.1    Kulasingam, S.L.2    Matchar, D.B.3
  • 136
    • 0036062771 scopus 로고    scopus 로고
    • Usefulness of FDG PET for assessment of early recurrent epithelial ovarian cancer
    • Cho S.M., Ha H.K., Byun J.Y., et al. Usefulness of FDG PET for assessment of early recurrent epithelial ovarian cancer. AJR Am J Roentgenol 179 (2002) 391-395
    • (2002) AJR Am J Roentgenol , vol.179 , pp. 391-395
    • Cho, S.M.1    Ha, H.K.2    Byun, J.Y.3
  • 137
    • 0034986738 scopus 로고    scopus 로고
    • Clinical value of positron emission tomography with FDG for recurrent ovarian cancer
    • Nakamoto Y., Safa T., Ishimori T., et al. Clinical value of positron emission tomography with FDG for recurrent ovarian cancer. AJR Am J Roentgenol 176 (2001) 1449-1454
    • (2001) AJR Am J Roentgenol , vol.176 , pp. 1449-1454
    • Nakamoto, Y.1    Safa, T.2    Ishimori, T.3
  • 138
    • 0034936676 scopus 로고    scopus 로고
    • Positive emission tomography for evaluating a complete clinical response in patients with ovarian or peritoneal carcinoma: correlation with second-look laparotomy
    • Rose P.G., Faulhaber P., Miraldi F., et al. Positive emission tomography for evaluating a complete clinical response in patients with ovarian or peritoneal carcinoma: correlation with second-look laparotomy. Gynecol Oncol 82 (2001) 17-21
    • (2001) Gynecol Oncol , vol.82 , pp. 17-21
    • Rose, P.G.1    Faulhaber, P.2    Miraldi, F.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.