메뉴 건너뛰기




Volumn 176, Issue 7, 2004, Pages 953-958

Diagnostic performance of a commercially available computer-aided diagnosis system for automatic detection of pulmonary nodules: Comparison with single and double reading

Author keywords

Computed tomography (CT); Computer, diagnostic aid; Lung, nodule

Indexed keywords

ADULT; ARTICLE; CLINICAL ARTICLE; COMPUTER ASSISTED DIAGNOSIS; COMPUTER ASSISTED TOMOGRAPHY; COMPUTER PROGRAM; DIAGNOSTIC ACCURACY; HUMAN; IMAGE ANALYSIS; IMAGING SYSTEM; INTERMETHOD COMPARISON; LOW DOSE COMPUTED TOMOGRAPHY; LOW ENERGY RADIATION; LUNG METASTASIS; LUNG NODULE; MULTIROW DETECTOR COMPUTER ASSISTED TOMOGRAPHY; PERFORMANCE; PRIORITY JOURNAL; REFERENCE VALUE;

EID: 3142743079     PISSN: 14389029     EISSN: None     Source Type: Journal    
DOI: 10.1055/s-2004-813251     Document Type: Article
Times cited : (53)

References (15)
  • 1
    • 0034772674 scopus 로고    scopus 로고
    • Radiologisches screening des bronchialkarzinoms: Aktueller stand und zukünftige perspektiven
    • Diederich S, Wormanns D, Heindel H. Radiologisches Screening des Bronchialkarzinoms: Aktueller Stand und zukünftige Perspektiven. Fortschr Röntgenstr 2001; 173: 873-882
    • (2001) Fortschr Röntgenstr , vol.173 , pp. 873-882
    • Diederich, S.1    Wormanns, D.2    Heindel, H.3
  • 2
    • 0037083775 scopus 로고    scopus 로고
    • Screening for lung cancer with lowdose spiral computed tomography
    • Swensen SJ, Jett JR, Sloan JA et al. Screening for lung cancer with lowdose spiral computed tomography. Am J Respir Crit Care Med 2002; 165: 508-513
    • (2002) Am J Respir Crit Care Med , vol.165 , pp. 508-513
    • Swensen, S.J.1    Jett, J.R.2    Sloan, J.A.3
  • 3
    • 0034538087 scopus 로고    scopus 로고
    • Small pulmonary nodules: Volumetrically determined growth rates based on CT evaluation
    • Yankelevitz DF, Reeves AP, Kostis WJ et al. Small pulmonary nodules: volumetrically determined growth rates based on CT evaluation. Radiology 2000; 217: 251-256
    • (2000) Radiology , vol.217 , pp. 251-256
    • Yankelevitz, D.F.1    Reeves, A.P.2    Kostis, W.J.3
  • 4
    • 0242432449 scopus 로고    scopus 로고
    • Indeterminate solitary pulmonary nodules revealed at population-based CT screening of the lung: Using first follow-up diagnostic CT to differentiate benign and malignant lesions
    • Takashima S, Sone S, Li F et al. Indeterminate solitary pulmonary nodules revealed at population-based CT screening of the lung: using first follow-up diagnostic CT to differentiate benign and malignant lesions. Am J Roentgenol 2003; 180: 1255-1263
    • (2003) Am J Roentgenol , vol.180 , pp. 1255-1263
    • Takashima, S.1    Sone, S.2    Li, F.3
  • 5
    • 0029114612 scopus 로고
    • Spiral CT of the chest: Comparison of cine and film-based viewing
    • Seltzer SE, Judy PF, Adams DF et al. Spiral CT of the chest: comparison of cine and film-based viewing. Radiology 1995; 197: 73-78
    • (1995) Radiology , vol.197 , pp. 73-78
    • Seltzer, S.E.1    Judy, P.F.2    Adams, D.F.3
  • 6
    • 0032909316 scopus 로고    scopus 로고
    • Helical CT of pulmonary nodules in patients with extrathoracic malignancy: CT-surgical correlation
    • Diederich S, Semik M, Lentschig MG et al. Helical CT of pulmonary nodules in patients with extrathoracic malignancy: CT-surgical correlation. Am J Roentgenol 1999; 172: 353-360
    • (1999) Am J Roentgenol , vol.172 , pp. 353-360
    • Diederich, S.1    Semik, M.2    Lentschig, M.G.3
  • 7
    • 0037257550 scopus 로고    scopus 로고
    • Detection of pulmonary metastases with multi-detector row CT scans of 5-mm nominal section thickness: Autopsy lung study
    • Kozuka T, Johkoh T, Hamada S et al. Detection of pulmonary metastases with multi-detector row CT scans of 5-mm nominal section thickness: autopsy lung study. Radiology 2003; 226: 231-234
    • (2003) Radiology , vol.226 , pp. 231-234
    • Kozuka, T.1    Johkoh, T.2    Hamada, S.3
  • 8
    • 0036582337 scopus 로고    scopus 로고
    • Automatic detection of pulmonary nodules at spiral CT: Clinical application of a computer-aided diagnosis system
    • Wormanns D, Fiebich M, Saidi M et al. Automatic detection of pulmonary nodules at spiral CT: clinical application of a computer-aided diagnosis system. Eur Radiol 2002; 12: 1052-1057
    • (2002) Eur Radiol , vol.12 , pp. 1052-1057
    • Wormanns, D.1    Fiebich, M.2    Saidi, M.3
  • 9
    • 0036891913 scopus 로고    scopus 로고
    • Lung cancer: Performance of automated lung nodule detection applied to cancers missed in a CT screening program
    • Armato SG, Li F, Giger ML et al. Lung cancer: performance of automated lung nodule detection applied to cancers missed in a CT screening program. Radiology 2002; 225: 685-692
    • (2002) Radiology , vol.225 , pp. 685-692
    • Armato, S.G.1    Li, F.2    Giger, M.L.3
  • 10
    • 0036892529 scopus 로고    scopus 로고
    • Lung cancers missed at low-dose helical CT screening in a general population: Comparison of clinical, histopathologic, and imaging findings
    • Li F, Sone S, Abe H et al. Lung cancers missed at low-dose helical CT screening in a general population: comparison of clinical, histopathologic, and imaging findings. Radiology 2002; 225: 673-683
    • (2002) Radiology , vol.225 , pp. 673-683
    • Li, F.1    Sone, S.2    Abe, H.3
  • 11
    • 0344234296 scopus 로고    scopus 로고
    • Computerunterstützte diagnostik in der thoraxradiologie - Aktuelle schwerpunkte und techniken
    • Achenbach T, Vomweg T, Heussel CP et al. Computerunterstützte Diagnostik in der Thoraxradiologie - aktuelle Schwerpunkte und Techniken. Fortschr Röntgenstr 2003; 175: 1471-1481
    • (2003) Fortschr Röntgenstr , vol.175 , pp. 1471-1481
    • Achenbach, T.1    Vomweg, T.2    Heussel, C.P.3
  • 12
    • 0036028244 scopus 로고    scopus 로고
    • Interobserver variations on interpretation of multislice CT lung cancer screening studies, and the implications for computer-aided diagnosis
    • Novak C, Qian J, Fan L et al. Interobserver variations on interpretation of multislice CT lung cancer screening studies, and the implications for computer-aided diagnosis. Proc SPIE 2002; 4686: 68-79
    • (2002) Proc SPIE , vol.4686 , pp. 68-79
    • Novak, C.1    Qian, J.2    Fan, L.3
  • 13
    • 1642580603 scopus 로고    scopus 로고
    • Pulmonary nodules at chest CT: Effect of computer-aided diagnosis on radiologists' detection performance
    • Awai K, Murao K, Ozawa A et al. Pulmonary nodules at chest CT: effect of computer-aided diagnosis on radiologists' detection performance. Radiology 2004; 230: 347-352
    • (2004) Radiology , vol.230 , pp. 347-352
    • Awai, K.1    Murao, K.2    Ozawa, A.3
  • 14
    • 0029787204 scopus 로고    scopus 로고
    • Sliding thin slab, minimum intensity projection technique in the diagnosis of emphysema: Histopathologic-CT correlation
    • Remy-Jardin M, Remy J, Gosselin B et al. Sliding thin slab, minimum intensity projection technique in the diagnosis of emphysema: histopathologic-CT correlation. Radiology 1996; 200: 665-671
    • (1996) Radiology , vol.200 , pp. 665-671
    • Remy-Jardin, M.1    Remy, J.2    Gosselin, B.3
  • 15
    • 0034831618 scopus 로고    scopus 로고
    • Mehrschicht-spiral-CT der lunge: Multiplanare rekonstruktionen und maximum-intensitäts-projektionen in der detektion lungenrundherden
    • Eibel R, Türk TR, Kulinna C et al. Mehrschicht-Spiral-CT der Lunge: Multiplanare Rekonstruktionen und Maximum-Intensitäts-Projektionen in der Detektion Lungenrundherden. Fortschr Röntgenstr 2001; 173: 815-821
    • (2001) Fortschr Röntgenstr , vol.173 , pp. 815-821
    • Eibel, R.1    Türk, T.R.2    Kulinna, C.3