Hepatic lesion detection: Comparison of MR imaging superparamagnetic iron oxide with dual-phase CT by using alternative-free response receiver operating characteristic analysis

Author keywords

Colon, neoplasms; Iron; Live neoplasms, MR; Liver neoplasms, CT; Liver neoplasms, metastases; Magnetic resonance (MR), comparative studies; Receiver operating characteristic curve (ROC)

Indexed keywords

SUPERPARAMAGNETIC IRON OXIDE;

EID: 0032956637     PISSN: 00338419     EISSN: None     Source Type: Journal    
DOI: 10.1148/radiology.210.2.r99fe05459     Document Type: Article
Times cited : (223)

References (35)
  • 1
    • 0028937598 scopus 로고
    • Dual-phase CT of the liver: Value of arterial phase scans in the detection of small (≤1.5 cm) malignant hepatic neoplasms
    • Hollett MD, Jeffrey RB, Nino-Murcia M, Jorgensen MJ, Harris DP. Dual-phase CT of the liver: value of arterial phase scans in the detection of small (≤1.5 cm) malignant hepatic neoplasms. AJR 1995; 164: 879-884.
    • (1995) AJR , vol.164 , pp. 879-884
    • Hollett, M.D.1    Jeffrey, R.B.2    Nino-Murcia, M.3    Jorgensen, M.J.4    Harris, D.P.5
  • 2
    • 0029820068 scopus 로고    scopus 로고
    • Spiral CT for the detection of hepatocellular carcinomas: Relative value of arterial- and late-phase scanning
    • Choi BI, Cho JM, Han JK, Choi DS, Han MC. Spiral CT for the detection of hepatocellular carcinomas: relative value of arterial- and late-phase scanning. Abdom Imaging 1996; 21:440-444.
    • (1996) Abdom Imaging , vol.21 , pp. 440-444
    • Choi, B.I.1    Cho, J.M.2    Han, J.K.3    Choi, D.S.4    Han, M.C.5
  • 3
    • 0029889815 scopus 로고    scopus 로고
    • Detecting hepatocellular carcinoma: Value of unenhanced or arterial phase CT imaging or both used in conjunction with conventional portal venous phase contrast-enhanced CT imaging
    • Oliver JH, Baron RL, Federle MP, Rockette HE. Detecting hepatocellular carcinoma: value of unenhanced or arterial phase CT imaging or both used in conjunction with conventional portal venous phase contrast-enhanced CT imaging. AJR 1996; 167:71-77.
    • (1996) AJR , vol.167 , pp. 71-77
    • Oliver, J.H.1    Baron, R.L.2    Federle, M.P.3    Rockette, H.E.4
  • 4
    • 0028875674 scopus 로고
    • Helical CT of the liver: Value of an early hepatic arterial phase
    • Bonaldi VM, Bret PM, Reinhold C, Atri M. Helical CT of the liver: value of an early hepatic arterial phase. Radiology 1995; 197:357-363.
    • (1995) Radiology , vol.197 , pp. 357-363
    • Bonaldi, V.M.1    Bret, P.M.2    Reinhold, C.3    Atri, M.4
  • 5
    • 0029685346 scopus 로고    scopus 로고
    • CT during arterial portography
    • Soyer P. CT during arterial portography. Eur Radiol 1996; 6:349-357.
    • (1996) Eur Radiol , vol.6 , pp. 349-357
    • Soyer, P.1
  • 6
    • 0021947111 scopus 로고
    • Dynamic computed tomography during arterial portography: The most sensitive examination for small hepato-cellular carcinomas
    • Matsui O, Takashima T, Kadoya M, et al. Dynamic computed tomography during arterial portography: the most sensitive examination for small hepato-cellular carcinomas. J Comput Assist Tomogr 1985; 9:19-24.
    • (1985) J Comput Assist Tomogr , vol.9 , pp. 19-24
    • Matsui, O.1    Takashima, T.2    Kadoya, M.3
  • 7
    • 0024516289 scopus 로고
    • Detection of focal hepatic masses: Prospective evaluation with CT, delayed CT, CT during arterial portography, and MR imaging
    • Heiken JP, Weyman PJ, Lee JK, et al. Detection of focal hepatic masses: prospective evaluation with CT, delayed CT, CT during arterial portography, and MR imaging. Radiology 1989; 171:47-51.
    • (1989) Radiology , vol.171 , pp. 47-51
    • Heiken, J.P.1    Weyman, P.J.2    Lee, J.K.3
  • 8
    • 0029122716 scopus 로고
    • Detection of liver metastases: Comparison of superparamagnetic iron oxide-enhanced MR imaging at 1.5T with dynamic CT, intraoperative US and percutaneous US
    • Hagspiel KD, Neidl KFW, Eichenberger AC, Weder W, Marincek B. Detection of liver metastases: comparison of superparamagnetic iron oxide-enhanced MR imaging at 1.5T with dynamic CT, intraoperative US and percutaneous US. Radiology 1995; 196:471-178.
    • (1995) Radiology , vol.196 , pp. 471-1178
    • Hagspiel, K.D.1    Neidl, K.F.W.2    Eichenberger, A.C.3    Weder, W.4    Marincek, B.5
  • 9
    • 0022470978 scopus 로고
    • ROC methodology in radiological imaging
    • Metz CE. ROC methodology in radiological imaging. Invest Radiol 1986; 21:720-733.
    • (1986) Invest Radiol , vol.21 , pp. 720-733
    • Metz, C.E.1
  • 10
    • 0025269074 scopus 로고
    • Free response methodology: Alternate analysis and a new observer-performance experiment
    • Chakraborty DP, Winter LHL. Free response methodology: alternate analysis and a new observer-performance experiment. Radiology 1990; 174:873-881.
    • (1990) Radiology , vol.174 , pp. 873-881
    • Chakraborty, D.P.1    Winter, L.H.L.2
  • 11
    • 0028283774 scopus 로고
    • Treatment of metastatic cancer to the liver
    • Sheiner PA, Brower ST. Treatment of metastatic cancer to the liver. Semin Liver Dis 1994; 14:169-177.
    • (1994) Semin Liver Dis , vol.14 , pp. 169-177
    • Sheiner, P.A.1    Brower, S.T.2
  • 12
    • 0025349440 scopus 로고
    • Surgical decision making for large bowel cancer metastatic to the liver
    • Sugarbaker PH. Surgical decision making for large bowel cancer metastatic to the liver. Radiology 1990; 174:621-626.
    • (1990) Radiology , vol.174 , pp. 621-626
    • Sugarbaker, P.H.1
  • 13
    • 0023155627 scopus 로고
    • Ferrite particles: A superparamagnetic contrast agent for the reticuloendothelial system
    • Saini S, Stark D, Hahn PF, et al. Ferrite particles: a superparamagnetic contrast agent for the reticuloendothelial system. Radiology 1987; 162:211-216.
    • (1987) Radiology , vol.162 , pp. 211-216
    • Saini, S.1    Stark, D.2    Hahn, P.F.3
  • 14
    • 0023801420 scopus 로고
    • Superparamagnetic iron oxide: Clinical application as a contrast agent for MR imaging of the liver
    • Stark DD, Weissleder R, Elizondo G, et al. Superparamagnetic iron oxide: clinical application as a contrast agent for MR imaging of the liver. Radiology 1988; 168:297-301.
    • (1988) Radiology , vol.168 , pp. 297-301
    • Stark, D.D.1    Weissleder, R.2    Elizondo, G.3
  • 15
    • 0024505526 scopus 로고
    • Superparamagnetic iron oxide: Pharmacokinetics and toxicity
    • Weissleder R, Stark DD, Englestad BL, et al. Superparamagnetic iron oxide: pharmacokinetics and toxicity. AJR 1989; 152: 167-173.
    • (1989) AJR , vol.152 , pp. 167-173
    • Weissleder, R.1    Stark, D.D.2    Englestad, B.L.3
  • 16
    • 0025079604 scopus 로고
    • Detection of hepatic metastases: Comparison of contrast-enhanced CT, unenhanced MRI and iron-oxide enhanced MR imaging
    • Fretz CJ, Stark DD, Metz CE, et al. Detection of hepatic metastases: comparison of contrast-enhanced CT, unenhanced MRI and iron-oxide enhanced MR imaging. AJR 1990; 155:763-770.
    • (1990) AJR , vol.155 , pp. 763-770
    • Fretz, C.J.1    Stark, D.D.2    Metz, C.E.3
  • 17
    • 0025163295 scopus 로고
    • Iron oxide-enhanced MR imaging of the liver and spleen: Review of the first 5 years
    • Ferrucci JT, Stark DD. Iron oxide-enhanced MR imaging of the liver and spleen: review of the first 5 years. AJR 1990; 155:943-950.
    • (1990) AJR , vol.155 , pp. 943-950
    • Ferrucci, J.T.1    Stark, D.D.2
  • 18
    • 0028046173 scopus 로고
    • Liver metastases: Safety and efficacy of detection with superparamagnetic iron oxide MR imaging
    • Bellin MR, Zaim S, Auberton E, et al. Liver metastases: safety and efficacy of detection with superparamagnetic iron oxide MR imaging. Radiology 1994; 193:657-663.
    • (1994) Radiology , vol.193 , pp. 657-663
    • Bellin, M.R.1    Zaim, S.2    Auberton, E.3
  • 19
    • 0029151620 scopus 로고
    • Hepatic MR imaging with ferumoxides: A multicenter clinical trial of the safety and efficacy in the detection of focal hepatic lesions
    • Ros PR, Freeny PC, Harms SE, et al. Hepatic MR imaging with ferumoxides: a multicenter clinical trial of the safety and efficacy in the detection of focal hepatic lesions. Radiology 1995; 196:478-481.
    • (1995) Radiology , vol.196 , pp. 478-481
    • Ros, P.R.1    Freeny, P.C.2    Harms, S.E.3
  • 20
    • 0028511368 scopus 로고
    • Contrast-enhanced MR imaging of liver and spleen: First experience in humans with a new superparamagnetic iron oxide
    • Hamm B, Staks T, Taupitz M, et al. Contrast-enhanced MR imaging of liver and spleen: first experience in humans with a new superparamagnetic iron oxide. JMRI 1994; 4:659-668.
    • (1994) JMRI , vol.4 , pp. 659-668
    • Hamm, B.1    Staks, T.2    Taupitz, M.3
  • 21
    • 84869594070 scopus 로고
    • Clinical results with Resovist: A phase II clinical trial
    • Reimer P, Rummeny EJ, Daldrup HE, et al. Clinical results with Resovist: a phase II clinical trial. Radiology 1995; 195:489-496.
    • (1995) Radiology , vol.195 , pp. 489-496
    • Reimer, P.1    Rummeny, E.J.2    Daldrup, H.E.3
  • 22
    • 0029808352 scopus 로고    scopus 로고
    • Detection of hepatic metastases: Ferumoxides-enhanced MR imaging versus unenhanced MR imaging and CT during arterial portography
    • Seneterre E, Taourel P, Bouvier Y, et al. Detection of hepatic metastases: ferumoxides-enhanced MR imaging versus unenhanced MR imaging and CT during arterial portography. Radiology 1996; 200: 785-792.
    • (1996) Radiology , vol.200 , pp. 785-792
    • Seneterre, E.1    Taourel, P.2    Bouvier, Y.3
  • 23
    • 0024339608 scopus 로고
    • Hepatic tumors: Comparison of CT during arterial portography, delayed CT, and MR imaging for preoperative evaluation
    • Nelson RC, Chezmar JL, Sugarbaker PH, Bernardino ME. Hepatic tumors: comparison of CT during arterial portography, delayed CT, and MR imaging for preoperative evaluation. Radiology 1989; 172:27-34.
    • (1989) Radiology , vol.172 , pp. 27-34
    • Nelson, R.C.1    Chezmar, J.L.2    Sugarbaker, P.H.3    Bernardino, M.E.4
  • 24
    • 0026747696 scopus 로고
    • Detection of liver metastases from colorectal cancer: Comparison of intraoperative US and CT during arterial portography
    • Soyer P, Levesque M, Elias D, Zeitoun G, Rocke A. Detection of liver metastases from colorectal cancer: comparison of intraoperative US and CT during arterial portography. Radiology 1992; 183:541-544.
    • (1992) Radiology , vol.183 , pp. 541-544
    • Soyer, P.1    Levesque, M.2    Elias, D.3    Zeitoun, G.4    Rocke, A.5
  • 25
    • 0027531615 scopus 로고
    • False positive diagnosis based on CT portography: Correlation with pathological findings
    • Soyer P, Lacheheb D, Levesque M. False positive diagnosis based on CT portography: correlation with pathological findings. AJR 1992; 160:285-289.
    • (1992) AJR , vol.160 , pp. 285-289
    • Soyer, P.1    Lacheheb, D.2    Levesque, M.3
  • 26
    • 0030995844 scopus 로고    scopus 로고
    • Hepatic lesion detection at MR imaging: A comparative study with four sequences
    • Blakeborough A, Ward J, Wilson D, et al. Hepatic lesion detection at MR imaging: a comparative study with four sequences. Radiology 1997; 203:759-765.
    • (1997) Radiology , vol.203 , pp. 759-765
    • Blakeborough, A.1    Ward, J.2    Wilson, D.3
  • 27
    • 0028328567 scopus 로고
    • T2-weighted MR imaging of the upper part of the abdomen: Should fat suppression be used routinely?
    • Lu DSK, Saini S, Hahn PF, et al. T2-weighted MR imaging of the upper part of the abdomen: should fat suppression be used routinely? AJR 1994; 162:1095-1100.
    • (1994) AJR , vol.162 , pp. 1095-1100
    • Lu, D.S.K.1    Saini, S.2    Hahn, P.F.3
  • 28
    • 0344590339 scopus 로고    scopus 로고
    • Imaging of focal liver lesions with fast SPIO-MR imaging in comparison with triple phase helical-CT
    • Mueller D, Kopka L, Fischer U, Grabbe EH. Imaging of focal liver lesions with fast SPIO-MR imaging in comparison with triple phase helical-CT (abstr). Radiology 1997;205(P):371.
    • (1997) Radiology , vol.205 , Issue.P , pp. 371
    • Mueller, D.1    Kopka, L.2    Fischer, U.3    Grabbe, E.H.4
  • 29
    • 0344158776 scopus 로고    scopus 로고
    • Detection of liver metastases: Prospective comparison of unenhanced and superparamagnetic iron oxide-enhanced MR imaging, dual-phase spiral-CT, and spiral CT during arterial portography
    • Lencioni RA, Laiolo E, Pinto F, Donati F, Giulianotti P, Bartolozzi C. Detection of liver metastases: prospective comparison of unenhanced and superparamagnetic iron oxide-enhanced MR imaging, dual-phase spiral-CT, and spiral CT during arterial portography (abstr). Radiology 1997; 205(P):371.
    • (1997) Radiology , vol.205 , Issue.P , pp. 371
    • Lencioni, R.A.1    Laiolo, E.2    Pinto, F.3    Donati, F.4    Giulianotti, P.5    Bartolozzi, C.6
  • 30
    • 0026095215 scopus 로고
    • Detection of hepatic masses in patients with carcinoma: Comparative sensitivities of sonography, CT and MR imaging
    • Wernecke K, Rummeny E, Bongartz G, et al. Detection of hepatic masses in patients with carcinoma: comparative sensitivities of sonography, CT and MR imaging. AJR 1991; 157:731-739.
    • (1991) AJR , vol.157 , pp. 731-739
    • Wernecke, K.1    Rummeny, E.2    Bongartz, G.3
  • 33
    • 0024519973 scopus 로고
    • Detection of liver metastases with superparamagnetic iron oxide in 15 patients: Results of MR imaging at 1.5T
    • Marchal G, Ven Hecke P, Demaerel P, et al. Detection of liver metastases with superparamagnetic iron oxide in 15 patients: results of MR imaging at 1.5T. AJR 1989; 152:771-775.
    • (1989) AJR , vol.152 , pp. 771-775
    • Marchal, G.1    Ven Hecke, P.2    Demaerel, P.3
  • 35
    • 0031040612 scopus 로고    scopus 로고
    • Detection and segmental location of malignant hepatic tumours: Comparison of ferumoxides-enhanced gradient-echo and T2-weighted spin-echo MR imaging
    • Van Beers BE, Lacrosse M, Jamart J, et al. Detection and segmental location of malignant hepatic tumours: comparison of ferumoxides-enhanced gradient-echo and T2-weighted spin-echo MR imaging. AJR 1997; 168:713-717.
    • (1997) AJR , vol.168 , pp. 713-717
    • Van Beers, B.E.1    Lacrosse, M.2    Jamart, J.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.