Volumn 854, Issue 1-2, 2007, Pages 43-47
|
Validated HPLC method for the determination of gabapentin in human plasma using pre-column derivatization with 1-fluoro-2,4-dinitrobenzene and its application to a pharmacokinetic study
|
Author keywords
1 Fluoro 2,4 dinitrobenzene; Epilepsy; Gabapentin; HPLC; UV detection
|
Indexed keywords
DRUG PRODUCTS;
HIGH PERFORMANCE LIQUID CHROMATOGRAPHY;
MAMMALS;
PLASMAS;
PRECIPITATION (CHEMICAL);
PROTEINS;
ULTRAVIOLET DETECTORS;
GABAPENTIN;
UV-DETECTION;
PHARMACOKINETICS;
1 FLUORO 2,4 DINITROBENZENE;
ACETONITRILE;
AMLODIPINE;
GABAPENTIN;
ACCURACY;
ADULT;
ARTICLE;
CLINICAL ARTICLE;
CLINICAL TRIAL;
DERIVATIZATION;
DRUG DETERMINATION;
FLOW RATE;
HIGH PERFORMANCE LIQUID CHROMATOGRAPHY;
HUMAN;
MALE;
NORMAL HUMAN;
PRIORITY JOURNAL;
SEPARATION TECHNIQUE;
ULTRAVIOLET RADIATION;
ADULT;
AMINES;
CALIBRATION;
CHROMATOGRAPHY, HIGH PRESSURE LIQUID;
CYCLOHEXANECARBOXYLIC ACIDS;
DINITROFLUOROBENZENE;
GAMMA-AMINOBUTYRIC ACID;
HUMANS;
MALE;
REPRODUCIBILITY OF RESULTS;
SENSITIVITY AND SPECIFICITY;
SPECTROPHOTOMETRY, ULTRAVIOLET;
|
EID: 34250732928
PISSN: 15700232
EISSN: None
Source Type: Journal
DOI: 10.1016/j.jchromb.2007.03.039 Document Type: Article |
Times cited : (52)
|
References (20)
|