메뉴 건너뛰기




Volumn 17, Issue 2, 2007, Pages 196-202

Comparison of Swedish interactive threshold algorithm and full threshold algorithm for glaucomatous visual field loss

Author keywords

Full threshold; Glaucomatous visual field defects; Swedish interactive threshold algorithm; Variability

Indexed keywords

ALGORITHM; ARTICLE; BAYES THEOREM; CONTROLLED STUDY; GENETIC VARIABILITY; GLAUCOMA; HUMAN; PERIMETRY; PREVALENCE; PRIORITY JOURNAL; SWEDEN; VISUAL FIELD; VISUAL FIELD DEFECT; VISUAL IMPAIRMENT;

EID: 34250366265     PISSN: 11206721     EISSN: None     Source Type: Journal    
DOI: 10.1177/112067210701700208     Document Type: Article
Times cited : (14)

References (24)
  • 1
    • 0023933541 scopus 로고
    • Fatigue effects in automated perimetry
    • Johnson CA, Adams CW, Lewis RA. Fatigue effects in automated perimetry. Appl Opt 1988; 27: 1030-7.
    • (1988) Appl Opt , vol.27 , pp. 1030-1037
    • Johnson, C.A.1    Adams, C.W.2    Lewis, R.A.3
  • 2
    • 0026715019 scopus 로고
    • Properties of staircase procedures for estimating thresholds in automated perimetry
    • Johnson CA, Chauhan BC, Shapiro LR. Properties of staircase procedures for estimating thresholds in automated perimetry. Invest Ophthalmol Vis Sci 1992; 33: 2966-74.
    • (1992) Invest Ophthalmol Vis Sci , vol.33 , pp. 2966-2974
    • Johnson, C.A.1    Chauhan, B.C.2    Shapiro, L.R.3
  • 3
    • 0028157639 scopus 로고
    • Fatigue effects during a single session of automated static threshold perimetry
    • Hudson C, Wild JM, O'Neill EC. Fatigue effects during a single session of automated static threshold perimetry. Invest Ophthalmol Vis Sci 1994; 35: 268-80.
    • (1994) Invest Ophthalmol Vis Sci , vol.35 , pp. 268-280
    • Hudson, C.1    Wild, J.M.2    O'Neill, E.C.3
  • 4
    • 0029162961 scopus 로고
    • Simulations for FASTPAC and the standard 4-2 dB full-threshold strategy of the Humphrey Field Analyzer
    • Glass E, Schaumberger M, Lachenmayr BJ. Simulations for FASTPAC and the standard 4-2 dB full-threshold strategy of the Humphrey Field Analyzer. Invest Ophthalmol Vis Sci 1995; 9: 1847-54.
    • (1995) Invest Ophthalmol Vis Sci , vol.9 , pp. 1847-1854
    • Glass, E.1    Schaumberger, M.2    Lachenmayr, B.J.3
  • 5
    • 0030817329 scopus 로고    scopus 로고
    • A new generation of algorithms for computerized threshold perimetry, SITA
    • Bengtsson B, Olsson J, Heijl A, Rootzen H. A new generation of algorithms for computerized threshold perimetry, SITA. Acta Ophthalmol Scand 1997; 75: 368-75.
    • (1997) Acta Ophthalmol Scand , vol.75 , pp. 368-375
    • Bengtsson, B.1    Olsson, J.2    Heijl, A.3    Rootzen, H.4
  • 6
    • 0030927853 scopus 로고    scopus 로고
    • An improved method to estimate frequency of false positive answers in computerized perimetry
    • Olsson J, Bengtsson B, Heijl A, Rootzen H. An improved method to estimate frequency of false positive answers in computerized perimetry. Acta Ophthalmol Scand 1997; 75: 181-3.
    • (1997) Acta Ophthalmol Scand , vol.75 , pp. 181-183
    • Olsson, J.1    Bengtsson, B.2    Heijl, A.3    Rootzen, H.4
  • 7
    • 0031867951 scopus 로고    scopus 로고
    • Evaluation of a new perimetric threshold strategy, SITA, in patients with manifest and suspect glaucoma
    • Bengtsson B, Heijl A. Evaluation of a new perimetric threshold strategy, SITA, in patients with manifest and suspect glaucoma. Acta Ophthalmol Scand 1998; 76: 268-72.
    • (1998) Acta Ophthalmol Scand , vol.76 , pp. 268-272
    • Bengtsson, B.1    Heijl, A.2
  • 8
    • 0036100772 scopus 로고    scopus 로고
    • Sensitivity and specificity of the Swedish interactive threshold algorithm for glaucomatous visual field defects
    • Budenz DL, Rhee P, Feuer WJ, Mcsoley J, Johnson CA, Anderson DR. Sensitivity and specificity of the Swedish interactive threshold algorithm for glaucomatous visual field defects. Ophthalmology 2002; 109: 1052-8.
    • (2002) Ophthalmology , vol.109 , pp. 1052-1058
    • Budenz, D.L.1    Rhee, P.2    Feuer, W.J.3    Mcsoley, J.4    Johnson, C.A.5    Anderson, D.R.6
  • 9
    • 0142200837 scopus 로고    scopus 로고
    • Properties of perimetric threshold estimates from Full Threshold, ZEST and SITA-like strategies as determined by computer simulation
    • Turpin A, McKendrick AM, Johnson CA, Vingrys AJ. Properties of perimetric threshold estimates from Full Threshold, ZEST and SITA-like strategies as determined by computer simulation. Invest Ophthalmol Vis Sci 2003; 44: 4787-95.
    • (2003) Invest Ophthalmol Vis Sci , vol.44 , pp. 4787-4795
    • Turpin, A.1    McKendrick, A.M.2    Johnson, C.A.3    Vingrys, A.J.4
  • 10
    • 0032779892 scopus 로고    scopus 로고
    • A new look at threshold estimation algorithms for automated static perimetry
    • Vingrys AJ, Pianta MJ. A new look at threshold estimation algorithms for automated static perimetry. Optom Vis Sci 1999; 76:588-95.
    • (1999) Optom Vis Sci , vol.76 , pp. 588-595
    • Vingrys, A.J.1    Pianta, M.J.2
  • 11
    • 0036328737 scopus 로고    scopus 로고
    • Properties of perimetric threshold estimates from Full Threshold, SITA Standard, and SITA Fast strategies
    • Artes PH, Iwase A, Ohno Y, Kitazawa Y, Chauhan BC. Properties of perimetric threshold estimates from Full Threshold, SITA Standard, and SITA Fast strategies. Invest Ophthalmol Vis Sci 2002; 43: 2654-9.
    • (2002) Invest Ophthalmol Vis Sci , vol.43 , pp. 2654-2659
    • Artes, P.H.1    Iwase, A.2    Ohno, Y.3    Kitazawa, Y.4    Chauhan, B.C.5
  • 12
    • 0031976913 scopus 로고    scopus 로고
    • Evaluation of a new threshold visual field strategy, SITA, in normal subjects
    • Bengtsson B, Heijl A, Olsson J. Evaluation of a new threshold visual field strategy, SITA, in normal subjects. Acta Ophthalmol Scand 1998; 76:165-9.
    • (1998) Acta Ophthalmol Scand , vol.76 , pp. 165-169
    • Bengtsson, B.1    Heijl, A.2    Olsson, J.3
  • 13
    • 0032941718 scopus 로고    scopus 로고
    • Inter-subject variability and normal limits of the SITA Standard, SITA Fast, and the Humphrey Full Threshold computerized perimetry strategies, SITA STATPAC
    • Bengtsson B, Heijl A. Inter-subject variability and normal limits of the SITA Standard, SITA Fast, and the Humphrey Full Threshold computerized perimetry strategies, SITA STATPAC. Acta Ophthalmol Scand 1999; 77: 125-9.
    • (1999) Acta Ophthalmol Scand , vol.77 , pp. 125-129
    • Bengtsson, B.1    Heijl, A.2
  • 14
    • 0036734696 scopus 로고    scopus 로고
    • Comparison of glaucomatous visual field defects using standard full threshold and Swedish interactive threshold algorithms
    • Budenz DL, Rhee P, Feuer WJ, Mcsoley J, Johnson CA, Anderson DR. Comparison of glaucomatous visual field defects using standard full threshold and Swedish interactive threshold algorithms. Arch Ophthalmol 2002; 120:1136-41.
    • (2002) Arch Ophthalmol , vol.120 , pp. 1136-1141
    • Budenz, D.L.1    Rhee, P.2    Feuer, W.J.3    Mcsoley, J.4    Johnson, C.A.5    Anderson, D.R.6
  • 15
    • 0034088692 scopus 로고    scopus 로고
    • Glaucoma follow-up when converting from long to short perimetric threshold tests
    • Heijl A, Bengtsson B, Patella VM. Glaucoma follow-up when converting from long to short perimetric threshold tests. Arch Ophthalmol 2000; 118: 489-93.
    • (2000) Arch Ophthalmol , vol.118 , pp. 489-493
    • Heijl, A.1    Bengtsson, B.2    Patella, V.M.3
  • 16
    • 0031731957 scopus 로고    scopus 로고
    • Evaluation of the Swedish interactive thresholding algorithm, a new thresholding algorithm, of the Humphrey Field Analyzer in glaucoma patients
    • Inazumi K, Tsuji A, Yamamoto T, Kitazawa Y. Evaluation of the Swedish interactive thresholding algorithm, a new thresholding algorithm, of the Humphrey Field Analyzer in glaucoma patients. J Jpn Ophthalmol Soc 1998; 102: 667-72.
    • (1998) J Jpn Ophthalmol Soc , vol.102 , pp. 667-672
    • Inazumi, K.1    Tsuji, A.2    Yamamoto, T.3    Kitazawa, Y.4
  • 17
    • 0034444235 scopus 로고    scopus 로고
    • Comparison of the Humphrey Swedish Interactive Thresholding Algorithm (SITA) and full threshold strategies
    • Sharma AK, Goldberg I, Graham SL, Mohsin M. Comparison of the Humphrey Swedish Interactive Thresholding Algorithm (SITA) and full threshold strategies. J Glaucoma 2000; 9: 20-7.
    • (2000) J Glaucoma , vol.9 , pp. 20-27
    • Sharma, A.K.1    Goldberg, I.2    Graham, S.L.3    Mohsin, M.4
  • 19
    • 0032955641 scopus 로고    scopus 로고
    • Between-algorithm, between-individual differences in normal perimetric sensitivity: Full Threshold, FASTPAC, and SITA
    • Wild JM, Pacey IE, Hancock SA, Cunliffe IA. Between-algorithm, between-individual differences in normal perimetric sensitivity: Full Threshold, FASTPAC, and SITA. Invest Ophthalmol Vis Sci 1999; 40: 1152-61.
    • (1999) Invest Ophthalmol Vis Sci , vol.40 , pp. 1152-1161
    • Wild, J.M.1    Pacey, I.E.2    Hancock, S.A.3    Cunliffe, I.A.4
  • 21
    • 0036841407 scopus 로고    scopus 로고
    • Full-threshold versus Swedish Interactive Threshold Algorithm (SITA) in normal individual undergoing automated perimetry for the fist time
    • Schimiti RB, Avelino RR, Kara-Jose N, Costa VP. Full-threshold versus Swedish Interactive Threshold Algorithm (SITA) in normal individual undergoing automated perimetry for the fist time. Ophthalmology 2002; 109: 2084-92.
    • (2002) Ophthalmology , vol.109 , pp. 2084-2092
    • Schimiti, R.B.1    Avelino, R.R.2    Kara-Jose, N.3    Costa, V.P.4
  • 23
    • 0011912225 scopus 로고
    • Improved test algorithms for automated perimetry
    • Krieglstein GK, ed, Heidelberg: Kaden Verlag
    • Heijl A. Improved test algorithms for automated perimetry. In: Krieglstein GK, ed. Glaucoma Update, vol. 5. Heidelberg: Kaden Verlag, 1995; 168-73.
    • (1995) Glaucoma Update , vol.5 , pp. 168-173
    • Heijl, A.1
  • 24


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.