메뉴 건너뛰기




Volumn 76, Issue 3, 1998, Pages 268-272

Evaluation of a new perimetric threshold strategy, SITA, in patients with manifest and suspect glaucoma

Author keywords

Clinical testing; Computerized threshold perimetry; Glaucoma; Visual field strategies

Indexed keywords

ADULT; AGED; ARTICLE; CLINICAL ARTICLE; CLINICAL EXAMINATION; CONTROLLED STUDY; DIAGNOSTIC ACCURACY; GLAUCOMA; HUMAN; INTRAOCULAR HYPERTENSION; PERIMETRY; PRIORITY JOURNAL; VISUAL FIELD; VISUAL THRESHOLD;

EID: 0031867951     PISSN: 13953907     EISSN: None     Source Type: Journal    
DOI: 10.1034/j.1600-0420.1998.760303.x     Document Type: Article
Times cited : (152)

References (13)
  • 1
    • 0031976913 scopus 로고    scopus 로고
    • Evaluation of a new threshold visual field strategy. SITA, in normal subjects
    • Bengtsson B, Heijl A & Olsson J (1998): Evaluation of a new threshold visual field strategy. SITA, in normal subjects. Acta Ophthalmol Scand 76: 165-169.
    • (1998) Acta Ophthalmol Scand , vol.76 , pp. 165-169
    • Bengtsson, B.1    Heijl, A.2    Olsson, J.3
  • 2
    • 0030817329 scopus 로고    scopus 로고
    • A new generation of algorithms for computerized threshold perimetry, SITA
    • Bengtsson B, Olsson J, Heijl A & Rootzén H (1997): A new generation of algorithms for computerized threshold perimetry, SITA. Acta Ophthalmol 75: 368-375.
    • (1997) Acta Ophthalmol , vol.75 , pp. 368-375
    • Bengtsson, B.1    Olsson, J.2    Heijl, A.3    Rootzén, H.4
  • 3
    • 0021280713 scopus 로고
    • Covariates of the long-term fluctuation of the differential light threshold
    • Flammer J, Drance SM & Schultzer M (1984): Covariates of the long-term fluctuation of the differential light threshold. Arch Ophthalmol 102: 880-882.
    • (1984) Arch Ophthalmol , vol.102 , pp. 880-882
    • Flammer, J.1    Drance, S.M.2    Schultzer, M.3
  • 5
    • 0020601188 scopus 로고
    • Changes in differential threshold in patients with glaucoma during prolonged perimetry
    • Heijl A & Drance SM (1983): Changes in differential threshold in patients with glaucoma during prolonged perimetry. Br J Ophthalmol 67: 512-516.
    • (1983) Br J Ophthalmol , vol.67 , pp. 512-516
    • Heijl, A.1    Drance, S.M.2
  • 6
    • 0017519514 scopus 로고
    • Time changes of contrast threshold during automatic perimetry
    • Copenh
    • Heijl A (1977): Time changes of contrast threshold during automatic perimetry. Acta Ophthalmol (Copenh) 55: 696-708.
    • (1977) Acta Ophthalmol , vol.55 , pp. 696-708
    • Heijl, A.1
  • 7
    • 0001924355 scopus 로고
    • The Humphrey Field Analyzer, construction and concepts
    • Heijl & Greve (eds). Documenta Ophthalmol. Proc series. Junk Publishers, Dordrecht
    • Heijl A (1985): The Humphrey Field Analyzer, construction and concepts. In: Heijl & Greve (eds). Documenta Ophthalmol. Proc series 42: 77-84. Proceedings of the 6th International Perimetric Society Meeting 1984. Junk Publishers, Dordrecht.
    • (1985) Proceedings of the 6th International Perimetric Society Meeting 1984 , vol.42 , pp. 77-84
    • Heijl, A.1
  • 8
    • 0024399833 scopus 로고
    • Test-retest variability in glaucomatous visual fields
    • Heijl A, Lindgren A & Lindgren G (1989): Test-retest variability in glaucomatous visual fields. Am J Ophthalmol 108: 130-135.
    • (1989) Am J Ophthalmol , vol.108 , pp. 130-135
    • Heijl, A.1    Lindgren, A.2    Lindgren, G.3
  • 9
    • 0000139368 scopus 로고
    • A package for the statistical analysis of computerized visual fields
    • Greve & Heijl (eds). Documenta Ophthalmol. proc series Junk Publishers, Dordrecht
    • Heijl A, Lindgren G & Olsson J (1987): A package for the statistical analysis of computerized visual fields. In: Greve & Heijl (eds). Documenta Ophthalmol. proc series 49:153-168. Proceedings of the 7th International Perimetric Society Meeting 1988, Junk Publishers, Dordrecht.
    • (1987) Proceedings of the 7th International Perimetric Society Meeting 1988 , vol.49 , pp. 153-168
    • Heijl, A.1    Lindgren, G.2    Olsson, J.3
  • 10
    • 0028157639 scopus 로고
    • Fatigue effects during a single session of automated static threshold perimetry
    • Hudson C, Wild JM & O'Neill EC (1994): Fatigue effects during a single session of automated static threshold perimetry. Invest Ophthalmol Vis Sci 35: 268-280.
    • (1994) Invest Ophthalmol Vis Sci , vol.35 , pp. 268-280
    • Hudson, C.1    Wild, J.M.2    O'Neill, E.C.3
  • 13
    • 0027032790 scopus 로고
    • The properties of perimetric thresholds in normal and glaucomatous eye
    • Weber J & Rau S (1992): The properties of perimetric thresholds in normal and glaucomatous eye. Ger J Ophthalmol 1: 79-85.
    • (1992) Ger J Ophthalmol , vol.1 , pp. 79-85
    • Weber, J.1    Rau, S.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.