메뉴 건너뛰기




Volumn 52, Issue 2, 2004, Pages 310-320

UNFOLD-SENSE: A parallel MRI method with self-calibration and artifact suppression

Author keywords

Artifact correction; Cardiac imaging; Fast imaging; Parallel imaging; Sense; Unfold

Indexed keywords

MAPPING;

EID: 3543128963     PISSN: 07403194     EISSN: None     Source Type: Journal    
DOI: 10.1002/mrm.20133     Document Type: Article
Times cited : (66)

References (28)
  • 1
    • 0030982409 scopus 로고    scopus 로고
    • Simultaneous acquisition of spatial harmonics (SMASH): Fast imaging with radiofrequency coil arrays
    • Sodickson DK, Manning WJ. Simultaneous acquisition of spatial harmonics (SMASH): fast imaging with radiofrequency coil arrays. Magn Reson Med 1997;38:591-603.
    • (1997) Magn Reson Med , vol.38 , pp. 591-603
    • Sodickson, D.K.1    Manning, W.J.2
  • 3
    • 0032751897 scopus 로고    scopus 로고
    • Unaliasing by Fourier-encoding the overlaps using the temporal dimension (UNFOLD), applied to cardiac imaging and fMRI
    • Madore B, Glover GH, Pelc NJ, Unaliasing by Fourier-encoding the overlaps using the temporal dimension (UNFOLD), applied to cardiac imaging and fMRI. Magn Reson Med 1999;42;813-828.
    • (1999) Magn Reson Med , vol.42 , pp. 813-828
    • Madore, B.1    Glover, G.H.2    Pelc, N.J.3
  • 4
    • 0036708129 scopus 로고    scopus 로고
    • Using UNFOLD to remove artifacts in parallel imaging and in partial-Fourier imaging
    • Madore B. Using UNFOLD to remove artifacts in parallel imaging and in partial-Fourier imaging. Magn Reson Med 2002;48:493-501.
    • (2002) Magn Reson Med , vol.48 , pp. 493-501
    • Madore, B.1
  • 5
    • 0035032781 scopus 로고    scopus 로고
    • Adaptive sensitivity encoding incorporating temporal filtering (TSENSE)
    • Kellman P, Epstein FH, McVeigh ER. Adaptive sensitivity encoding incorporating temporal filtering (TSENSE), Magn Reson Med 2001;45: 846-852.
    • (2001) Magn Reson Med , vol.45 , pp. 846-852
    • Kellman, P.1    Epstein, F.H.2    McVeigh, E.R.3
  • 6
    • 0242385483 scopus 로고    scopus 로고
    • k-t BLAST and k-t SENSE: Dynamic MRI with high frame rate exploiting spatiotemporal correlations
    • Tsao J, Boesiger P, Pruessmann KP, k-t BLAST and k-t SENSE: dynamic MRI with high frame rate exploiting spatiotemporal correlations. Magn Reson Med 2003;50:1031-1042.
    • (2003) Magn Reson Med , vol.50 , pp. 1031-1042
    • Tsao, J.1    Boesiger, P.2    Pruessmann, K.P.3
  • 7
    • 0027992115 scopus 로고
    • Dynamically adaptive MRI with encoding by singular value decomposition
    • Zientara GP, Panych LP, Jolesz FA. Dynamically adaptive MRI with encoding by singular value decomposition. Magn Reson Med 1994;32: 268-274.
    • (1994) Magn Reson Med , vol.32 , pp. 268-274
    • Zientara, G.P.1    Panych, L.P.2    Jolesz, F.A.3
  • 8
    • 0029923709 scopus 로고    scopus 로고
    • Implementation of a fast gradient-echo SVD encoding technique for dynamic imaging
    • Panych LP, Oesterle C, Zientara GP, Hennig J. Implementation of a fast gradient-echo SVD encoding technique for dynamic imaging. Magn Reson Med 1996;35:554-562.
    • (1996) Magn Reson Med , vol.35 , pp. 554-562
    • Panych, L.P.1    Oesterle, C.2    Zientara, G.P.3    Hennig, J.4
  • 11
    • 0010068927 scopus 로고    scopus 로고
    • Using UNFOLD to remove artifacts in dynamic imaging
    • Glasgow, Scotland
    • Madore B, Using UNFOLD to remove artifacts in dynamic imaging. In: Proceedings of the 9th Annual Meeting of ISMRM, Glasgow, Scotland, 2001, p 444.
    • (2001) Proceedings of the 9th Annual Meeting of ISMRM , pp. 444
    • Madore, B.1
  • 17
    • 0036135282 scopus 로고    scopus 로고
    • On the UNFOLD method
    • Tsao J. On the UNFOLD method. Magn Reson Med 2002;47:202-207.
    • (2002) Magn Reson Med , vol.47 , pp. 202-207
    • Tsao, J.1
  • 18
    • 0033646259 scopus 로고    scopus 로고
    • Low-latency temporal filter design for real-time MRI using UNFOLD
    • Kellman P, Sorger JM, Epstein FH, McVeigh ER. Low-latency temporal filter design for real-time MRI using UNFOLD. Magn Reson Med 2000; 44:933-939.
    • (2000) Magn Reson Med , vol.44 , pp. 933-939
    • Kellman, P.1    Sorger, J.M.2    Epstein, F.H.3    McVeigh, E.R.4
  • 21
    • 0010172555 scopus 로고    scopus 로고
    • Reduced field-of-view dynamic imaging with 2D spatially selective excitation and UNFOLD
    • Honolulu
    • Zhao L, Madore B, Panych LP. Reduced field-of-view dynamic imaging with 2D spatially selective excitation and UNFOLD. In: Proceedings of the 10th Annual Meeting of ISMRM, Honolulu, 2002. p 76.
    • (2002) Proceedings of the 10th Annual Meeting of ISMRM , pp. 76
    • Zhao, L.1    Madore, B.2    Panych, L.P.3
  • 22
    • 0035006567 scopus 로고    scopus 로고
    • SMASH and SENSE: Experimental and numerical comparisons
    • Madore B, Pelc NJ, SMASH and SENSE: experimental and numerical comparisons. Magn Reson Med 2001;45:1103-1111,
    • (2001) Magn Reson Med , vol.45 , pp. 1103-1111
    • Madore, B.1    Pelc, N.J.2
  • 26
    • 3543052512 scopus 로고    scopus 로고
    • UNFOLD-SENSE: A self-calibrated parallel imaging method with artifact suppression
    • Honolulu
    • Madore B. UNFOLD-SENSE: a self-calibrated parallel imaging method with artifact suppression. In: Proceedings of the 10th Annual Meeting of ISMRM, Honolulu, 2002.
    • (2002) Proceedings of the 10th Annual Meeting of ISMRM
    • Madore, B.1
  • 27
    • 0034120692 scopus 로고    scopus 로고
    • Reconstructing MR images from undersampled data: Data-weighting considerations
    • Pipe JG. Reconstructing MR images from undersampled data: data-weighting considerations. Magn Reson Med 2000;43:867-875.
    • (2000) Magn Reson Med , vol.43 , pp. 867-875
    • Pipe, J.G.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.