메뉴 건너뛰기




Volumn 5, Issue 3, 2007, Pages 413-421

Imagify™ (perflubutane polymer microspheres) injectable suspension for the assessment of coronary artery disease

Author keywords

Coronary heart disease; Diagnostic accuracy; Efficacy; Imagify ; Pharmakokinetics; Safety; Ultrasound contrast

Indexed keywords

AI 700; CARDIOSPHERE; CONSTA; ECHO CONTRAST MEDIUM; FS 069; GOSERELIN; IMAGIFY; LEUPRORELIN; MICROSPHERE; OCTREOTIDE; PERFLUORO COMPOUND; PERFLUOROBUTANE; PERFLUTREN; PLACEBO; POLYGLACTIN; RISPERIDONE; SONOVUE; UNCLASSIFIED DRUG; DIAGNOSTIC AGENT; FLUOROCARBON; POLYMER;

EID: 34249295930     PISSN: 14779072     EISSN: 17448344     Source Type: Journal    
DOI: 10.1586/14779072.5.3.413     Document Type: Article
Times cited : (9)

References (27)
  • 1
    • 0028938462 scopus 로고
    • Myocardial contrast echocardiography in coronary artery disease: Potential applications using venous injections of contrast
    • Kaul S. Myocardial contrast echocardiography in coronary artery disease: potential applications using venous injections of contrast. Am. J. Cardiol. 75(11), 61D-68D (1995).
    • (1995) Am. J. Cardiol , vol.75 , Issue.11
    • Kaul, S.1
  • 2
    • 0032501992 scopus 로고    scopus 로고
    • Quantification of myocardial blood flow with ultrasound-induced destruction of microbubbles administered as a constant venous infusion
    • Wei K, Jayaweera AR, Firoozan S, Linka A, Skyba DM, Kaul S. Quantification of myocardial blood flow with ultrasound-induced destruction of microbubbles administered as a constant venous infusion. Circulation 97(5), 473-483 (1998).
    • (1998) Circulation , vol.97 , Issue.5 , pp. 473-483
    • Wei, K.1    Jayaweera, A.R.2    Firoozan, S.3    Linka, A.4    Skyba, D.M.5    Kaul, S.6
  • 3
    • 34249275817 scopus 로고    scopus 로고
    • Myocardial perfusion imaging during stress using contrast echocardiography
    • Zamarano JL, Garcia-Fernandez MA Eds, Springer, Milan, Italy
    • Monaghan M. Myocardial perfusion imaging during stress using contrast echocardiography. In: Contrast Echocardiograpby in Clinical Practice. Zamarano JL, Garcia-Fernandez MA (Eds). Springer, Milan, Italy, 175-190 (2007).
    • (2007) Contrast Echocardiograpby in Clinical Practice , pp. 175-190
    • Monaghan, M.1
  • 4
    • 4844224266 scopus 로고    scopus 로고
    • Incremental benefit of myocardial contrast to combined dipyridamole - exercise stress echocardiography for the assessment of coronary artery disease
    • Moir S, Haluska BA, Jenkins C, Fathi R, Marwick TH. Incremental benefit of myocardial contrast to combined dipyridamole - exercise stress echocardiography for the assessment of coronary artery disease. Circulation 110(9), 1108-1113 (2004).
    • (2004) Circulation , vol.110 , Issue.9 , pp. 1108-1113
    • Moir, S.1    Haluska, B.A.2    Jenkins, C.3    Fathi, R.4    Marwick, T.H.5
  • 5
    • 0037950405 scopus 로고    scopus 로고
    • Comparison of usefulness of dipyridamole stress myocardial contrast echocardiography to technetium-99m sestamibi single-photon emission computed tomography for detection of coronary artery disease (PB127 multicenter Phase 2 trial results)
    • Wei K, Crouse L, Weiss J et al. Comparison of usefulness of dipyridamole stress myocardial contrast echocardiography to technetium-99m sestamibi single-photon emission computed tomography for detection of coronary artery disease (PB127 multicenter Phase 2 trial results). Am. J. Cardiol. 91(11), 1293-1298 (2003).
    • (2003) Am. J. Cardiol , vol.91 , Issue.11 , pp. 1293-1298
    • Wei, K.1    Crouse, L.2    Weiss, J.3
  • 6
    • 3042770848 scopus 로고    scopus 로고
    • Myocardial perfusion assessment in patients with medium probability of coronary artery disease and no prior myocardial infarction: Comparison of myocardial contrast echocardiography with 99mTc single-photon emission computed tomography
    • Senior R, Lepper W, Pasquet A et al. Myocardial perfusion assessment in patients with medium probability of coronary artery disease and no prior myocardial infarction: comparison of myocardial contrast echocardiography with 99mTc single-photon emission computed tomography. Am. Heart J. 147(6), 1100-1105 (2004).
    • (2004) Am. Heart J , vol.147 , Issue.6 , pp. 1100-1105
    • Senior, R.1    Lepper, W.2    Pasquet, A.3
  • 7
    • 1042264292 scopus 로고    scopus 로고
    • Assessment of the physiologic significance of coronary disease with dipyridamole real-time myocardial contrast echocardiography. Comparison with technetium-99m sestamibi single-photon emission computed tomography and quantitative coronary angiography
    • Peltier M, Vancraeynest D, Pasquet A et al. Assessment of the physiologic significance of coronary disease with dipyridamole real-time myocardial contrast echocardiography. Comparison with technetium-99m sestamibi single-photon emission computed tomography and quantitative coronary angiography. J. Am. Coll. Cardiol. 43(2), 257-264 (2004).
    • (2004) J. Am. Coll. Cardiol , vol.43 , Issue.2 , pp. 257-264
    • Peltier, M.1    Vancraeynest, D.2    Pasquet, A.3
  • 8
    • 29344437525 scopus 로고    scopus 로고
    • Myocardial contrast echocardiography for the detection of coronary artery stenosis: A prospective multicenter study in comparison with single-photon emission computed tomography
    • Jeetley P, Hickman M, Kamp O et al. Myocardial contrast echocardiography for the detection of coronary artery stenosis: a prospective multicenter study in comparison with single-photon emission computed tomography. J. Am. Coll. Cardiol. 47(1), 141-145 (2006).
    • (2006) J. Am. Coll. Cardiol , vol.47 , Issue.1 , pp. 141-145
    • Jeetley, P.1    Hickman, M.2    Kamp, O.3
  • 9
    • 33845223507 scopus 로고    scopus 로고
    • Myocardial contrast echocardiography evolving as a clinically feasible technique for accurate, rapid, and safe assessment of myocardial perfusion: The evidence so far
    • Dijkmans PA, Senior R, Becher H et al. Myocardial contrast echocardiography evolving as a clinically feasible technique for accurate, rapid, and safe assessment of myocardial perfusion: the evidence so far. J. Am. Coll. Cardiol. 48(11), 2168-2177 (2006).
    • (2006) J. Am. Coll. Cardiol , vol.48 , Issue.11 , pp. 2168-2177
    • Dijkmans, P.A.1    Senior, R.2    Becher, H.3
  • 10
    • 0031955290 scopus 로고    scopus 로고
    • Effect of blood and microbubble oxygen and nitrogen content on perfluorocarbon-filled dextrose albumin microbubble size and efficacy: In vitro and in vivo studies
    • Porter T, Kricsfeld D, Cheatham S, Li S. Effect of blood and microbubble oxygen and nitrogen content on perfluorocarbon-filled dextrose albumin microbubble size and efficacy: in vitro and in vivo studies. J. Am. Soc. Echocardiogr. 11 (5), 421-425 (1998).
    • (1998) J. Am. Soc. Echocardiogr , vol.11 , Issue.5 , pp. 421-425
    • Porter, T.1    Kricsfeld, D.2    Cheatham, S.3    Li, S.4
  • 11
    • 0030226472 scopus 로고    scopus 로고
    • Increased ultrasound contrast and decreased microbubble destruction rates with triggered ultrasound imaging
    • Porter TR, Xie F, Li S, D'Sa A, Rafter P. Increased ultrasound contrast and decreased microbubble destruction rates with triggered ultrasound imaging. J. Am. Soc. Echocardiogr. 9(5), 599-605 (1996).
    • (1996) J. Am. Soc. Echocardiogr , vol.9 , Issue.5 , pp. 599-605
    • Porter, T.R.1    Xie, F.2    Li, S.3    D'Sa, A.4    Rafter, P.5
  • 12
    • 0030889485 scopus 로고    scopus 로고
    • Detection of myocardial perfusion in multiple echocardiographic windows with one intravenous injection of microbubbles using transient response second harmonic imaging
    • Porter TR, Li S, Kricsfeld D, Armbruster RW. Detection of myocardial perfusion in multiple echocardiographic windows with one intravenous injection of microbubbles using transient response second harmonic imaging. J. Am. Coll. Cardiol. 29(4), 791-799 (1997).
    • (1997) J. Am. Coll. Cardiol , vol.29 , Issue.4 , pp. 791-799
    • Porter, T.R.1    Li, S.2    Kricsfeld, D.3    Armbruster, R.W.4
  • 13
    • 0033009439 scopus 로고    scopus 로고
    • Real-time visualization of myocardial perfusion and wall thickening in human beings with intravenous ultrasonographic contrast and accelerated intermittent harmonic imaging
    • Porter TR, Li S, Jiang L, Grayburn P, Deligonul U. Real-time visualization of myocardial perfusion and wall thickening in human beings with intravenous ultrasonographic contrast and accelerated intermittent harmonic imaging. J. Am. Soc. Echocardiogr. 12(4), 266-271 (1999).
    • (1999) J. Am. Soc. Echocardiogr , vol.12 , Issue.4 , pp. 266-271
    • Porter, T.R.1    Li, S.2    Jiang, L.3    Grayburn, P.4    Deligonul, U.5
  • 14
    • 19044387992 scopus 로고    scopus 로고
    • Evaluation of a new ultrasound contrast agent (AI-700) using two-dimensional and three-dimensional imaging during acute ischemia
    • Yao J, Takeuchi M, Teupe C et al. Evaluation of a new ultrasound contrast agent (AI-700) using two-dimensional and three-dimensional imaging during acute ischemia. J. Am. Soc. Echocardiogr. 15(7), 686-694 (2002).
    • (2002) J. Am. Soc. Echocardiogr , vol.15 , Issue.7 , pp. 686-694
    • Yao, J.1    Takeuchi, M.2    Teupe, C.3
  • 15
    • 0042991200 scopus 로고    scopus 로고
    • The effects of AI-700 echo-contrast perfusion and/or wall motion imaging on detection of perfusion in patients with coronary artery disease [Abstract]
    • Picard M, Pandian N, Morcerf F et al. The effects of AI-700 echo-contrast perfusion and/or wall motion imaging on detection of perfusion in patients with coronary artery disease [Abstract]. J. Am. Soc. Echocardiogr. 14, 460 (2001).
    • (2001) J. Am. Soc. Echocardiogr , vol.14 , pp. 460
    • Picard, M.1    Pandian, N.2    Morcerf, F.3
  • 16
    • 0035282040 scopus 로고    scopus 로고
    • Real-time assessment of myocardial perfusion and wall motion during bicycle and treadmill exercise echocardiography: Comparison with single photon emission computed tomography
    • Shimoni S, Zoghbi WA, Xie F et al. Real-time assessment of myocardial perfusion and wall motion during bicycle and treadmill exercise echocardiography: comparison with single photon emission computed tomography. J. Am. Coll. Cardiol. 37(3), 741-747 (2001).
    • (2001) J. Am. Coll. Cardiol , vol.37 , Issue.3 , pp. 741-747
    • Shimoni, S.1    Zoghbi, W.A.2    Xie, F.3
  • 17
    • 0004138266 scopus 로고    scopus 로고
    • The acoustical responses of AI-700 in vitro [Abstract]
    • Church CC. The acoustical responses of AI-700 in vitro [Abstract]. J. Am. Soc. Echocardiogr. 13, 457 (2000).
    • (2000) J. Am. Soc. Echocardiogr , vol.13 , pp. 457
    • Church, C.C.1
  • 19
    • 26944470343 scopus 로고    scopus 로고
    • Porous PLGA microparticles: AI-700, an intravenously administered ultrasound contrast agent for use in echocardiography
    • Straub JA, Chickering DE, Church CC, Shah B, Hanlon T, Bernstein H. Porous PLGA microparticles: AI-700, an intravenously administered ultrasound contrast agent for use in echocardiography. J. Control. Release 108(1), 21-32 (2005).
    • (2005) J. Control. Release , vol.108 , Issue.1 , pp. 21-32
    • Straub, J.A.1    Chickering, D.E.2    Church, C.C.3    Shah, B.4    Hanlon, T.5    Bernstein, H.6
  • 20
    • 34249287130 scopus 로고    scopus 로고
    • Acusphere Inc. Investigator's brochure: investigational product AI-700. Edition 5.0 (2006).
    • Acusphere Inc. Investigator's brochure: investigational product AI-700. Edition 5.0 (2006).
  • 21
    • 34249292758 scopus 로고    scopus 로고
    • AI-700 pharmacokinetics, tissue distribution and exhaled elimination kinetics in rats
    • Straub JA, Chickering DE, Hartman TG, Gloff CA, Bernstein H. AI-700 pharmacokinetics, tissue distribution and exhaled elimination kinetics in rats. Int. J. Pharm. 328(1), 35-41 (2007).
    • (2007) Int. J. Pharm , vol.328 , Issue.1 , pp. 35-41
    • Straub, J.A.1    Chickering, D.E.2    Hartman, T.G.3    Gloff, C.A.4    Bernstein, H.5
  • 23
    • 33845704634 scopus 로고    scopus 로고
    • Initial safety and myocardial perfusion imaging results with AI-700: A synthetic polymeric ultrasound contrast agent [Abstract]
    • Walovitch RC, Kwan OL, Picard MH et al. Initial safety and myocardial perfusion imaging results with AI-700: a synthetic polymeric ultrasound contrast agent [Abstract]. J Am. Soc. Echocardiogr. 13, 457 (2000).
    • (2000) J Am. Soc. Echocardiogr , vol.13 , pp. 457
    • Walovitch, R.C.1    Kwan, O.L.2    Picard, M.H.3
  • 24
    • 24644496509 scopus 로고    scopus 로고
    • Comparison of myocardial contrast ECHO to 99mTC MIBI SPECT in patients with myocardial perfusion defects: A Phase 2 study of AI-700 [Abstract]
    • Weissman N, Grayburn P, Klein A. Comparison of myocardial contrast ECHO to 99mTC MIBI SPECT in patients with myocardial perfusion defects: a Phase 2 study of AI-700 [Abstract]. J. Am. Soc. Echocardiogr. 14, 461 (2001).
    • (2001) J. Am. Soc. Echocardiogr , vol.14 , pp. 461
    • Weissman, N.1    Grayburn, P.2    Klein, A.3
  • 25
    • 34249337847 scopus 로고    scopus 로고
    • Comparison of AI-700 echo and nuclear perfusion imaging to coronary angiography in patients with suspected coronary disease [Abstract]
    • Grayburn PA, Zoghbi WA, Weissman NJ et al. Comparison of AI-700 echo and nuclear perfusion imaging to coronary angiography in patients with suspected coronary disease [Abstract]. J. Am. Soc. Echocardiogr. 17, 502 (2004).
    • (2004) J. Am. Soc. Echocardiogr , vol.17 , pp. 502
    • Grayburn, P.A.1    Zoghbi, W.A.2    Weissman, N.J.3
  • 27
    • 0023178922 scopus 로고
    • Using body surface mapping to detect vulnerability to ventricular arrhythmias in patients with coronary artery disease
    • Yasumura S, Kubota I, Ikeda K, Tsuiki K, Yasui S. Using body surface mapping to detect vulnerability to ventricular arrhythmias in patients with coronary artery disease. J. Electrocardiol. 20(2), 114-120 (1987).
    • (1987) J. Electrocardiol , vol.20 , Issue.2 , pp. 114-120
    • Yasumura, S.1    Kubota, I.2    Ikeda, K.3    Tsuiki, K.4    Yasui, S.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.