메뉴 건너뛰기




Volumn 25, Issue 5, 2007, Pages 982-991

Multiple regression method for pulmonary apparent diffusion coefficient measurement by hyperpolarized 3He MRI

Author keywords

Apparent diffusion coefficient; Diffusion sensitization; Hyperpolarized 3He MRI; Measurement uncertainty; Multiple regression method

Indexed keywords

HELIUM;

EID: 34247847771     PISSN: 10531807     EISSN: 15222586     Source Type: Journal    
DOI: 10.1002/jmri.20901     Document Type: Article
Times cited : (4)

References (38)
  • 4
    • 0031397685 scopus 로고    scopus 로고
    • 3He MRI: Preliminary clinical experience in 18 patients with and without lung disease
    • 3He MRI: preliminary clinical experience in 18 patients with and without lung disease. J Magn Reson 1997;7:538-543.
    • (1997) J Magn Reson , vol.7 , pp. 538-543
    • Kauczor, H.-U.1    Eberle, B.2    Kreitner, K.F.3
  • 5
    • 17544386265 scopus 로고    scopus 로고
    • 3He MRI in healthy volunteers: Preliminary correlation with smoking history and lung volumes
    • 3He MRI in healthy volunteers: preliminary correlation with smoking history and lung volumes. NMR Biomed 2000;13:182-189.
    • (2000) NMR Biomed , vol.13 , pp. 182-189
    • Guenther, D.1    Eberle, B.2    Hast, J.3
  • 8
    • 0032896724 scopus 로고    scopus 로고
    • An MR imaging method for simultaneous measurement of gaseous diffusion constant and longitudinal relaxation time
    • Dimitrov IE, Charagundla SR, Rizi RR, Reddy R, Leigh JS. An MR imaging method for simultaneous measurement of gaseous diffusion constant and longitudinal relaxation time. Magn Reson Imaging 1999;17:267-273.
    • (1999) Magn Reson Imaging , vol.17 , pp. 267-273
    • Dimitrov, I.E.1    Charagundla, S.R.2    Rizi, R.R.3    Reddy, R.4    Leigh, J.S.5
  • 10
    • 0344980295 scopus 로고    scopus 로고
    • Spatially resolved measurements of hyperpolarized gas properties in the lung in vivo. Part I: Diffusion coefficient
    • Chen XJ, Moller HE, Chawla MS, et al. Spatially resolved measurements of hyperpolarized gas properties in the lung in vivo. Part I: diffusion coefficient. Magn Reson Med 1999;42:721-728.
    • (1999) Magn Reson Med , vol.42 , pp. 721-728
    • Chen, X.J.1    Moller, H.E.2    Chawla, M.S.3
  • 12
    • 0036135901 scopus 로고    scopus 로고
    • 3He diffusion imaging of the lung
    • 3He diffusion imaging of the lung. Radiology 2002;222:8-11.
    • (2002) Radiology , vol.222 , pp. 8-11
    • Mayo, J.R.1    Hayden, M.E.2
  • 17
    • 0033945191 scopus 로고    scopus 로고
    • 2 and its time course during apnea in healthy volunteers: First results, reproducibility, and technical limitations
    • 2 and its time course during apnea in healthy volunteers: first results, reproducibility, and technical limitations. NMR Biomed 2000;13:194-201.
    • (2000) NMR Biomed , vol.13 , pp. 194-201
    • Deninger, A.J.1    Eberle, B.2    Ebert, M.3
  • 20
    • 4744369965 scopus 로고    scopus 로고
    • Single-acquisition sequence for the measurement of oxygen partial pressure by hyperpolarized gas MRI
    • Fischer MC, Spector ZZ, Ishii M, et al. Single-acquisition sequence for the measurement of oxygen partial pressure by hyperpolarized gas MRI. Magn Reson Med 2004;52:766-773.
    • (2004) Magn Reson Med , vol.52 , pp. 766-773
    • Fischer, M.C.1    Spector, Z.Z.2    Ishii, M.3
  • 21
    • 0000857966 scopus 로고    scopus 로고
    • J.C.Liner SW. Determination of temperature dependence of gaseous diffusion coeficients using gas chromatographic apparatus. J Chem Phys 1972;56:2288-2290.
    • J.C.Liner SW. Determination of temperature dependence of gaseous diffusion coeficients using gas chromatographic apparatus. J Chem Phys 1972;56:2288-2290.
  • 23
    • 36849127288 scopus 로고
    • Use of spin echoes in a pulsed magnetic-field gradient to study anisotropic, restricted diffusion and flow
    • Stejskal EO. Use of spin echoes in a pulsed magnetic-field gradient to study anisotropic, restricted diffusion and flow. J Chem Phys 1965;43:3597-3603.
    • (1965) J Chem Phys , vol.43 , pp. 3597-3603
    • Stejskal, E.O.1
  • 25
    • 23344450484 scopus 로고    scopus 로고
    • Assessment of lung microstructure with magnetic resonance imaging of hyperpolarized Helium-3
    • Wolfgang G, Schreiber AEM, Trine Stavngaard, et al. Assessment of lung microstructure with magnetic resonance imaging of hyperpolarized Helium-3. Respir Physiol Neurobiol 2005;148:23-42.
    • (2005) Respir Physiol Neurobiol , vol.148 , pp. 23-42
    • Wolfgang, G.1    Schreiber, A.E.M.2    Stavngaard, T.3
  • 26
    • 20044381701 scopus 로고    scopus 로고
    • Morbach AE GK, Schmiedeskamp J, Dahmen A, et al. Diffusion-weighted MRI of the lung with hyperpolarized helium-3: a study of reproducibility. J Magn Reson Imaging 2005;21:765-774.
    • Morbach AE GK, Schmiedeskamp J, Dahmen A, et al. Diffusion-weighted MRI of the lung with hyperpolarized helium-3: a study of reproducibility. J Magn Reson Imaging 2005;21:765-774.
  • 28
    • 0344549306 scopus 로고    scopus 로고
    • Spatially resolved measurements of hyperpolarized gas properties in the lung in vivo. Part II: T2*
    • Chen XJ, Möller HEC, M. S., et al. Spatially resolved measurements of hyperpolarized gas properties in the lung in vivo. Part II: T2*. Magn Reson Med 1999;42:729-737.
    • (1999) Magn Reson Med , vol.42 , pp. 729-737
    • Chen, X.J.1    Möller, H.M.S.2
  • 29
    • 0036260586 scopus 로고    scopus 로고
    • 3He MRI and arterial spin tagging in healthy normal subjects and in pulmonary embolism and orthotopic lung transplant patients
    • 3He MRI and arterial spin tagging in healthy normal subjects and in pulmonary embolism and orthotopic lung transplant patients. Magn Reson Med 2002;47:1073-1076.
    • (2002) Magn Reson Med , vol.47 , pp. 1073-1076
    • Lipson, D.A.1    Roberts, D.A.2    Hansen-Flaschen, J.3
  • 31
    • 0021948756 scopus 로고
    • Measurement of signal intensities in the presence of noise in MR images
    • Henkelman RM. Measurement of signal intensities in the presence of noise in MR images. Med Phys 1985;12:232-233.
    • (1985) Med Phys , vol.12 , pp. 232-233
    • Henkelman, R.M.1
  • 32
    • 0028839871 scopus 로고
    • The Rician distribution of noisy MRI data
    • Gudbjartsson H, Patz S. The Rician distribution of noisy MRI data. Magn Reson Med 1995;34:910-914.
    • (1995) Magn Reson Med , vol.34 , pp. 910-914
    • Gudbjartsson, H.1    Patz, S.2
  • 33
    • 3242778538 scopus 로고    scopus 로고
    • MRI of helium-3 gas in healthy lungs: Posture related variations of alveolar size
    • Stanislao Fichele NW, Andrew J, Swift, Zead Said, et al. MRI of helium-3 gas in healthy lungs: posture related variations of alveolar size. J Magn Reson Imaging 2004;20:331-335.
    • (2004) J Magn Reson Imaging , vol.20 , pp. 331-335
    • Stanislao Fichele, N.W.1    Andrew, J.2
  • 34
    • 33846810869 scopus 로고    scopus 로고
    • Measurements of regional alveolar oxygen pressure and oxygen depletion rate by hyperpolarized 3He MRI in small animals
    • Miami Beach, FL, USA, Abstract 1830
    • Yu J, Fischer MC, Ishii M, Emami K, Rizi RR. Measurements of regional alveolar oxygen pressure and oxygen depletion rate by hyperpolarized 3He MRI in small animals. In: Proceedings of the 13th Annual Meeting of ISMRM, Miami Beach, FL, USA, 2005 (Abstract 1830).
    • (2005) Proceedings of the 13th Annual Meeting of ISMRM
    • Yu, J.1    Fischer, M.C.2    Ishii, M.3    Emami, K.4    Rizi, R.R.5
  • 35
    • 34247843605 scopus 로고    scopus 로고
    • Nonlinear fitting method for the measurements of regional alveolar oxygen pressure and oxygen depletion rate by hyperpolarized 3He MRI
    • Seattle, WA, USA, Abstract 1340
    • Yu J, Emami K, Ishii M, et al. Nonlinear fitting method for the measurements of regional alveolar oxygen pressure and oxygen depletion rate by hyperpolarized 3He MRI. In: Proceedings of the 14th Annual Meeting of ISMRM, Seattle, WA, USA, 2006 (Abstract 1340).
    • (2006) Proceedings of the 14th Annual Meeting of ISMRM
    • Yu, J.1    Emami, K.2    Ishii, M.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.