메뉴 건너뛰기




Volumn 53, Issue 5, 2005, Pages 1055-1064

3D volume-localized pO2 measurement in the human lung with 3He MRI

Author keywords

3D gradient echo; 3helium; Diffusion; Hyperpolarized; Oxygen; Perfusion; Ventilation

Indexed keywords

DIFFUSION; OXYGEN; SIGNAL ANALYSIS; VENTILATION;

EID: 15844407792     PISSN: 07403194     EISSN: None     Source Type: Journal    
DOI: 10.1002/mrm.20423     Document Type: Article
Times cited : (94)

References (19)
  • 10
    • 2342588151 scopus 로고    scopus 로고
    • Magnetization tagging decay to measure long-range (3)He diffusion in healthy and emphysematous canine lungs
    • Woods JC, Yablonskiy DA, Chino K, Tanoli TS, Cooper JD, Conradi MS. Magnetization tagging decay to measure long-range (3)He diffusion in healthy and emphysematous canine lungs. Magn Reson Med 2004;51: 1002-1008.
    • (2004) Magn Reson Med , vol.51 , pp. 1002-1008
    • Woods, J.C.1    Yablonskiy, D.A.2    Chino, K.3    Tanoli, T.S.4    Cooper, J.D.5    Conradi, M.S.6
  • 11
    • 0031480383 scopus 로고    scopus 로고
    • Spin-exchange optical pumping of noble-gas nuclei
    • Walker TG, Happer W. Spin-exchange optical pumping of noble-gas nuclei. Rev Mod Phys 1997;69:629-642.
    • (1997) Rev Mod Phys , vol.69 , pp. 629-642
    • Walker, T.G.1    Happer, W.2
  • 14
    • 1242287522 scopus 로고    scopus 로고
    • Investigating 3He diffusion NMR in the lungs using finite difference simulations and in vivo PGSE experiments
    • Fichele S, Paley MN, Woodhouse N, Griffiths PD, van Beek EJ, Wild JM. Investigating 3He diffusion NMR in the lungs using finite difference simulations and in vivo PGSE experiments. J Magn Reson 2004;167:1-11.
    • (2004) J Magn Reson , vol.167 , pp. 1-11
    • Fichele, S.1    Paley, M.N.2    Woodhouse, N.3    Griffiths, P.D.4    Van Beek, E.J.5    Wild, J.M.6
  • 15
    • 0021948756 scopus 로고
    • Measurement of signal intensities in the presence of noise in MR images
    • Henkelman RM. Measurement of signal intensities in the presence of noise in MR images. Med Phys 1985;12:232-233.
    • (1985) Med Phys , vol.12 , pp. 232-233
    • Henkelman, R.M.1
  • 16
    • 0036201635 scopus 로고    scopus 로고
    • k-Space filtering in 2D gradient-echo breath-hold hyperpolarized 3He MRI: Spatial resolution and signal-to-noise ratio considerations
    • Wild JM, Paley MN, Viallon M, Schreiber WG, van Beek EJ, Griffiths PD. k-Space filtering in 2D gradient-echo breath-hold hyperpolarized 3He MRI: spatial resolution and signal-to-noise ratio considerations. Magn Reson Med 2002;47:687-695.
    • (2002) Magn Reson Med , vol.47 , pp. 687-695
    • Wild, J.M.1    Paley, M.N.2    Viallon, M.3    Schreiber, W.G.4    Van Beek, E.J.5    Griffiths, P.D.6
  • 17
    • 4444320114 scopus 로고    scopus 로고
    • Hyperpolarized 3He lung ventilation imaging with B1-inhomogeneity correction in a single breath-hold scan
    • Miller GW, Altes TA, Brookeman JR, De Lange EE, Mugler 3rd JP. Hyperpolarized 3He lung ventilation imaging with B1-inhomogeneity correction in a single breath-hold scan, MAGMA 2004;16:218-226.
    • (2004) MAGMA , vol.16 , pp. 218-226
    • Miller, G.W.1    Altes, T.A.2    Brookeman, J.R.3    De Lange, E.E.4    Mugler III, J.P.5
  • 18
    • 0036158539 scopus 로고    scopus 로고
    • Sensitivity calculations and comparisons for shielded elliptical and circular birdcage coils
    • De Zanche N, Allen PS. Sensitivity calculations and comparisons for shielded elliptical and circular birdcage coils. Magn Reson Med 2002; 47:364-371.
    • (2002) Magn Reson Med , vol.47 , pp. 364-371
    • De Zanche, N.1    Allen, P.S.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.