메뉴 건너뛰기




Volumn 141, Issue 2, 1999, Pages 207-216

Quantification of Regional Intrapulmonary Oxygen Partial Pressure Evolution during Apnea by 3He MRI

Author keywords

Functional imaging; Hyperpolarized gas MRI; Intrapulmonary oxygen; MRI of lung; Oxygen concentration

Indexed keywords

DIAGNOSTIC AGENT; HELIUM; ISOTOPE; OXYGEN;

EID: 0033257617     PISSN: 10907807     EISSN: None     Source Type: Journal    
DOI: 10.1006/jmre.1999.1902     Document Type: Article
Times cited : (180)

References (26)
  • 17
    • 0001352588 scopus 로고
    • Nuclear spin-lattice relaxation in the presence of magnetic-field gradients
    • L. D. Schearer and G. K. Walters, Nuclear spin-lattice relaxation in the presence of magnetic-field gradients, Phys. Rev. 139(5A), 1398-1402 (1965).
    • (1965) Phys. Rev. , vol.139 , Issue.5 A , pp. 1398-1402
    • Schearer, L.D.1    Walters, G.K.2
  • 18
    • 0001064575 scopus 로고
    • Relaxation of spins due to field inhomogeneities in gaseous samples at low magnetic fields and low pressures
    • G. D. Cates, S. R. Schaefer, and W. Happer, Relaxation of spins due to field inhomogeneities in gaseous samples at low magnetic fields and low pressures, Phys. Rev. A 37, 2877-2885 (1988).
    • (1988) Phys. Rev. A , vol.37 , pp. 2877-2885
    • Cates, G.D.1    Schaefer, S.R.2    Happer, W.3
  • 21
    • 24544451660 scopus 로고
    • Very long nuclear relaxation times of spin polarized helium 3 in metal coated cells
    • W. Heil, H. Humblot, E. W. Otten, M. Schäfer, R. Surkau, and M. Leduc, Very long nuclear relaxation times of spin polarized helium 3 in metal coated cells, Phys. Lett. A 201, 337-343 (1995).
    • (1995) Phys. Lett. A , vol.201 , pp. 337-343
    • Heil, W.1    Humblot, H.2    Otten, E.W.3    Schäfer, M.4    Surkau, R.5    Leduc, M.6
  • 23
    • 0021948756 scopus 로고
    • Measurement of signal intensities in the presence of noise in MR images
    • Erratum: Med. Phys. 13, 544 (1986)
    • R. M. Henkelman, Measurement of signal intensities in the presence of noise in MR images, Med. Phys. 12, 232-233 (1985). [Erratum: Med. Phys. 13, 544 (1986)]
    • (1985) Med. Phys. , vol.12 , pp. 232-233
    • Henkelman, R.M.1
  • 24
    • 0028839871 scopus 로고
    • The Rician distribution of noisy MRI data
    • H. Gudbjartsson and S. Patz, The Rician distribution of noisy MRI data, Magn. Res. Med. 34, 910-914 (1995).
    • (1995) Magn. Res. Med. , vol.34 , pp. 910-914
    • Gudbjartsson, H.1    Patz, S.2
  • 26
    • 0347696505 scopus 로고    scopus 로고
    • Considerations in using the variable-flip-angle method in laser polarized magnetic resonance gas imaging and spectroscopy experiments
    • J. Knight-Scott, V. M. Mai, J. P. Mugler III, J. R. Brookeman, Considerations in using the variable-flip-angle method in laser polarized magnetic resonance gas imaging and spectroscopy experiments, Proc. Intl. Soc. Magn. Res. Med. 7, 2092 (1999).
    • (1999) Proc. Intl. Soc. Magn. Res. Med. , vol.7 , pp. 2092
    • Knight-Scott, J.1    Mai, V.M.2    Mugler J.P. III3    Brookeman, J.R.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.