-
1
-
-
0035889335
-
Intensity-modulated radiotherapy: Current status and issues of interest
-
Intensity Modulated Radiation Therapy Collaborative Working Group
-
Intensity Modulated Radiation Therapy Collaborative Working Group. Intensity-modulated radiotherapy: current status and issues of interest. Int J Radiat Oncol Biol Phys. 2001;51(4):880-914.
-
(2001)
Int J Radiat Oncol Biol Phys
, vol.51
, Issue.4
, pp. 880-914
-
-
-
2
-
-
0036127055
-
Communication and sampling rate limitations in IMRT delivery with a dynamic multileaf collimator system
-
Xia P, Chuang CF, Verhey LJ. Communication and sampling rate limitations in IMRT delivery with a dynamic multileaf collimator system. Med Phys. 2002;29(3):412-423.
-
(2002)
Med Phys
, vol.29
, Issue.3
, pp. 412-423
-
-
Xia, P.1
Chuang, C.F.2
Verhey, L.J.3
-
3
-
-
0035015664
-
Dosimetric validation for multileaf collimator-based intensity modulated radiotherapy: A review
-
Arnfield MR, Wu Q, Tong S, Mohan R. Dosimetric validation for multileaf collimator-based intensity modulated radiotherapy: a review. Med Dosim. 2001;26(2):179-188.
-
(2001)
Med Dosim
, vol.26
, Issue.2
, pp. 179-188
-
-
Arnfield, M.R.1
Wu, Q.2
Tong, S.3
Mohan, R.4
-
4
-
-
0031762329
-
Physical and dosimetric aspects of a multileaf collimation system used in the dynamic mode for implementing intensity modulated radiotherapy
-
LoSasso T, Chui CS, Ling CC. Physical and dosimetric aspects of a multileaf collimation system used in the dynamic mode for implementing intensity modulated radiotherapy. Med Phys. 1998;25(10):1919-1927.
-
(1998)
Med Phys
, vol.25
, Issue.10
, pp. 1919-1927
-
-
LoSasso, T.1
Chui, C.S.2
Ling, C.C.3
-
5
-
-
0033848727
-
Some limitations in the practical delivery of intensity modulated radiation therapy
-
Meyer J, Mills JA, Haas OCL, Parvin EM, Burnham KJ. Some limitations in the practical delivery of intensity modulated radiation therapy. Br J Radiol. 2000;73(872):854-863.
-
(2000)
Br J Radiol
, vol.73
, Issue.872
, pp. 854-863
-
-
Meyer, J.1
Mills, J.A.2
Haas, O.C.L.3
Parvin, E.M.4
Burnham, K.J.5
-
6
-
-
0037342156
-
Using the volumetric effect of a finite-sized detector for routine quality assurance of multileaf collimator leaf positioning
-
Yang Y, Xing L. Using the volumetric effect of a finite-sized detector for routine quality assurance of multileaf collimator leaf positioning. Med Phys. 2003;30(3):433-441.
-
(2003)
Med Phys
, vol.30
, Issue.3
, pp. 433-441
-
-
Yang, Y.1
Xing, L.2
-
7
-
-
0035011160
-
Delivery systems of intensity-modulated radiotherapy using conventional multileaf collimators
-
Xia P, Verhey LJ. Delivery systems of intensity-modulated radiotherapy using conventional multileaf collimators. Med Dosim. 2001;26(2):169-177.
-
(2001)
Med Dosim
, vol.26
, Issue.2
, pp. 169-177
-
-
Xia, P.1
Verhey, L.J.2
-
8
-
-
0035180383
-
Calibration and quality assurance for rounded leaf-end MLC systems
-
Graves MN, Thompson AV, Martel MK, McShan DL, Fraass BA. Calibration and quality assurance for rounded leaf-end MLC systems. Med Phys. 2001;28(11):2227-2233.
-
(2001)
Med Phys
, vol.28
, Issue.11
, pp. 2227-2233
-
-
Graves, M.N.1
Thompson, A.V.2
Martel, M.K.3
McShan, D.L.4
Fraass, B.A.5
-
9
-
-
0038587417
-
MLC quality assurance techniques for IMRT applications
-
Bayouth JE, Wendt D, Morrill SM. MLC quality assurance techniques for IMRT applications. Med Phys. 2003;30(5):743-749.
-
(2003)
Med Phys
, vol.30
, Issue.5
, pp. 743-749
-
-
Bayouth, J.E.1
Wendt, D.2
Morrill, S.M.3
-
10
-
-
0036117951
-
Dose to radiation therapists from activation at high-energy accelerators used for conventional and intensity-modulated radiation therapy
-
Rawlinson JA, Islam MK, Galbraith DM. Dose to radiation therapists from activation at high-energy accelerators used for conventional and intensity-modulated radiation therapy. Med Phys. 2002;29(4):598-608.
-
(2002)
Med Phys
, vol.29
, Issue.4
, pp. 598-608
-
-
Rawlinson, J.A.1
Islam, M.K.2
Galbraith, D.M.3
-
11
-
-
0030793184
-
Estimates of whole-body dose equivalent produced by beam intensity modulated conformal therapy
-
Followill D, Geis P, Boyer A. Estimates of whole-body dose equivalent produced by beam intensity modulated conformal therapy. Int J Radiat Oncol Biol Phys. 1997;38(3):667-672.
-
(1997)
Int J Radiat Oncol Biol Phys
, vol.38
, Issue.3
, pp. 667-672
-
-
Followill, D.1
Geis, P.2
Boyer, A.3
-
12
-
-
0030884958
-
-
Followill D, Geis P, Boyer A. Erratum: estimates of whole-body dose equivalent produced by beam intensity modulated conformal therapy. Int J Radiat Oncol Biol Phys. 1997;39(3):783.
-
Followill D, Geis P, Boyer A. Erratum: estimates of whole-body dose equivalent produced by beam intensity modulated conformal therapy. Int J Radiat Oncol Biol Phys. 1997;39(3):783.
-
-
-
-
13
-
-
0034078005
-
Intensity modulation delivery techniques: "step and shoot" MLC autosequence versus the use of a modulator
-
Chang SX, Cullip TJ, Deschesne KM. Intensity modulation delivery techniques: "step and shoot" MLC autosequence versus the use of a modulator. Med Phys. 2000;27(5):948-959.
-
(2000)
Med Phys
, vol.27
, Issue.5
, pp. 948-959
-
-
Chang, S.X.1
Cullip, T.J.2
Deschesne, K.M.3
-
14
-
-
0033000694
-
Accuracy of numerically produced compensators
-
Thompson H, Evans MD, Fallone BG. Accuracy of numerically produced compensators. Med Dosim. 1999;24(1):49-52.
-
(1999)
Med Dosim
, vol.24
, Issue.1
, pp. 49-52
-
-
Thompson, H.1
Evans, M.D.2
Fallone, B.G.3
-
15
-
-
0035067023
-
Compensators for IMRT - an investigation in quality assurance
-
Bakal A, Laub WU, Nusslin F. Compensators for IMRT - an investigation in quality assurance. Z Med Phys. 2001;1l(1):15-22.
-
(2001)
Z Med Phys
, vol.1 l
, Issue.1
, pp. 15-22
-
-
Bakal, A.1
Laub, W.U.2
Nusslin, F.3
-
16
-
-
0036430212
-
Compensators for intensity modulated beams
-
Dimitriadis DM, Fallone BG. Compensators for intensity modulated beams. Med Dosim. 2002;27(3):215-220.
-
(2002)
Med Dosim
, vol.27
, Issue.3
, pp. 215-220
-
-
Dimitriadis, D.M.1
Fallone, B.G.2
-
18
-
-
0038586578
-
A multiportal compensator system for IMRT delivery
-
Yoda K, Aoki Y. A multiportal compensator system for IMRT delivery. Med Phys. 2003;30(5):880-886.
-
(2003)
Med Phys
, vol.30
, Issue.5
, pp. 880-886
-
-
Yoda, K.1
Aoki, Y.2
-
19
-
-
0036798789
-
Reshapable physical modulator for intensity modulated radiation therapy
-
Xu T, Shikhaliev PM, Al-Ghazi M, Molloi S. Reshapable physical modulator for intensity modulated radiation therapy. Med Phys. 2002;29(10):2222-2229.
-
(2002)
Med Phys
, vol.29
, Issue.10
, pp. 2222-2229
-
-
Xu, T.1
Shikhaliev, P.M.2
Al-Ghazi, M.3
Molloi, S.4
-
20
-
-
22544455941
-
A packed building-block compensator (TETRIS-RT) and feasibility for IMRT delivery
-
Nakagawa K, Fukuhara N, Kawakami H. A packed building-block compensator (TETRIS-RT) and feasibility for IMRT delivery. Med Phys. 2005;32(7):2231-2235.
-
(2005)
Med Phys
, vol.32
, Issue.7
, pp. 2231-2235
-
-
Nakagawa, K.1
Fukuhara, N.2
Kawakami, H.3
-
21
-
-
3042513347
-
Credentialing of institutions for IMRT in clinical trials
-
Palta JR, Deye JA, Ibbott GS, et al. Credentialing of institutions for IMRT in clinical trials. Int J Radiat Oncol Biol Phys. 2004;59(4):1257-1262.
-
(2004)
Int J Radiat Oncol Biol Phys
, vol.59
, Issue.4
, pp. 1257-1262
-
-
Palta, J.R.1
Deye, J.A.2
Ibbott, G.S.3
-
22
-
-
0031861573
-
A technique for the quantitative evaluation of dose distributions
-
Low DA, Harms WB, Mutic S, et al. A technique for the quantitative evaluation of dose distributions. Med Phys. 1998;25(5):656-661.
-
(1998)
Med Phys
, vol.25
, Issue.5
, pp. 656-661
-
-
Low, D.A.1
Harms, W.B.2
Mutic, S.3
-
23
-
-
0033407585
-
Intensity-modulation radiotherapy using independent collimators: An algorithm study
-
Dai JR, Hu YM. Intensity-modulation radiotherapy using independent collimators: an algorithm study. Med Phys. 1999;26(12):2565-2570.
-
(1999)
Med Phys
, vol.26
, Issue.12
, pp. 2565-2570
-
-
Dai, J.R.1
Hu, Y.M.2
-
24
-
-
0035989958
-
Direct aperture optimization: A turnkey solution for step-and-shoot IMRT
-
Shepard DM, Earl MA, Li XA, et al. Direct aperture optimization: a turnkey solution for step-and-shoot IMRT. Med Phys. 2002;29(6):1007-1018.
-
(2002)
Med Phys
, vol.29
, Issue.6
, pp. 1007-1018
-
-
Shepard, D.M.1
Earl, M.A.2
Li, X.A.3
-
25
-
-
1242293101
-
The delivery of IMRT with a single physical modulator for multiple fields: A feasibility study for paranasal sinus cancer
-
O'Daniel JC, Dong L, Kuban DA, et al. The delivery of IMRT with a single physical modulator for multiple fields: a feasibility study for paranasal sinus cancer. Int J Radiat Oncol Biol Phys. 2004;58(3):876-887.
-
(2004)
Int J Radiat Oncol Biol Phys
, vol.58
, Issue.3
, pp. 876-887
-
-
O'Daniel, J.C.1
Dong, L.2
Kuban, D.A.3
-
26
-
-
0031805413
-
On modulator design for photon beam intensity-modulated conformal therapy
-
Jiang SB, Ayyangar KM. On modulator design for photon beam intensity-modulated conformal therapy. Med Phys. 1998;25(5):668-675.
-
(1998)
Med Phys
, vol.25
, Issue.5
, pp. 668-675
-
-
Jiang, S.B.1
Ayyangar, K.M.2
|