메뉴 건너뛰기




Volumn 30, Issue 3, 2003, Pages 433-441

Using the volumetric effect of a finite-sized detector for routine quality assurance of multileaf collimator leaf positioning

Author keywords

Dose measurement; IMRT; Multileaf collimator; Quality assurance

Indexed keywords

BIOMEDICAL ENGINEERING; ERRORS; LOCATION; QUALITY ASSURANCE;

EID: 0037342156     PISSN: 00942405     EISSN: None     Source Type: Journal    
DOI: 10.1118/1.1543150     Document Type: Article
Times cited : (18)

References (25)
  • 2
    • 0031834130 scopus 로고    scopus 로고
    • An optimized leaf-setting algorithm for beam intensity modulation using dynamic multileaf collimators
    • L. Ma, A. L. Boyer, L. Xing, and C. M. Ma, "An optimized leaf-setting algorithm for beam intensity modulation using dynamic multileaf collimators," Phys. Med. Biol. 43, 1629-1643 (1998).
    • (1998) Phys. Med. Biol. , vol.43 , pp. 1629-1643
    • Ma, L.1    Boyer, A.L.2    Xing, L.3    Ma, C.M.4
  • 3
    • 0031868367 scopus 로고    scopus 로고
    • Multileaf collimator leaf sequencing algorithm for intensity modulated beams with multiple static segments
    • P. Xia and L. J. Verhey, "Multileaf collimator leaf sequencing algorithm for intensity modulated beams with multiple static segments," Med. Phys. 25, 1424-1434 (1998).
    • (1998) Med. Phys. , vol.25 , pp. 1424-1434
    • Xia, P.1    Verhey, L.J.2
  • 4
    • 0032736686 scopus 로고    scopus 로고
    • Comparison of algorithms for multileaf collimator field segmentation
    • W. Que, "Comparison of algorithms for multileaf collimator field segmentation," Med. Phys. 26, 2390-2396 (1999).
    • (1999) Med. Phys. , vol.26 , pp. 2390-2396
    • Que, W.1
  • 5
    • 0035664146 scopus 로고    scopus 로고
    • Delivery of intensity-modulated radiation therapy with a conventional multileaf collimator: Comparison of dynamic and segmental methods
    • C. S. Chui, M. F. Chan, E. Yorke, S. Spirou, and C. C. Ling, "Delivery of intensity-modulated radiation therapy with a conventional multileaf collimator: Comparison of dynamic and segmental methods," Med. Phys. 28, 2441-2449 (2001).
    • (2001) Med. Phys. , vol.28 , pp. 2441-2449
    • Chui, C.S.1    Chan, M.F.2    Yorke, E.3    Spirou, S.4    Ling, C.C.5
  • 6
    • 0026661373 scopus 로고
    • The generation of intensity-modulated fields for conformal radiotherapy by dynamic collimation
    • D. J. Convey and M. E. Rosenbloom, "The generation of intensity-modulated fields for conformal radiotherapy by dynamic collimation," Phys. Med. Biol. 37, 1359-1374 (1992).
    • (1992) Phys. Med. Biol. , vol.37 , pp. 1359-1374
    • Convey, D.J.1    Rosenbloom, M.E.2
  • 7
    • 0028144837 scopus 로고
    • Generation of arbitrary intensity profiles by dynamic jaws or multileaf collimators
    • S. V. Spirou and C. S. Chui, "Generation of arbitrary intensity profiles by dynamic jaws or multileaf collimators," Med. Phys. 21, 1031-1041 (1994).
    • (1994) Med. Phys. , vol.21 , pp. 1031-1041
    • Spirou, S.V.1    Chui, C.S.2
  • 8
    • 0028153801 scopus 로고
    • An analytical solution for the dynamic control of multileaf collimators
    • R. Svensson, P. Kallman, and A. Brahme, "An analytical solution for the dynamic control of multileaf collimators," Phys. Med. Biol. 39, 37-61 (1994).
    • (1994) Phys. Med. Biol. , vol.39 , pp. 37-61
    • Svensson, R.1    Kallman, P.2    Brahme, A.3
  • 9
    • 0028077046 scopus 로고
    • Dynamic x-ray compensation for conformal radiotherapy by means of multi-leaf collimation
    • R. Stein, T. Bortfeld, B. Dorschel, and W. Schlegel, "Dynamic x-ray compensation for conformal radiotherapy by means of multi-leaf collimation," Radiother. Oncol. 32, 163-173 (1994).
    • (1994) Radiother. Oncol. , vol.32 , pp. 163-173
    • Stein, R.1    Bortfeld, T.2    Dorschel, B.3    Schlegel, W.4
  • 10
    • 0030199938 scopus 로고    scopus 로고
    • Conformal radiation treatment of prostate cancer using inversely-planned intensity-modulated photon beams produced with dynamic multileaf collimation
    • C. C. Ling, C. Burman, C. S. Chui, G. J. Kutcher, S. A. Leibel, T. LoSasso, and R. Mohan, "Conformal radiation treatment of prostate cancer using inversely-planned intensity-modulated photon beams produced with dynamic multileaf collimation," Int. J. Radiat. Oncol., Biol., Phys. 35, 721-730 (1996).
    • (1996) Int. J. Radiat. Oncol., Biol., Phys. , vol.35 , pp. 721-730
    • Ling, C.C.1    Burman, C.2    Chui, C.S.3    Kutcher, G.J.4    Leibel, S.A.5    LoSasso, T.6    Mohan, R.7
  • 11
    • 0030661596 scopus 로고    scopus 로고
    • Planning, delivery, and quality assurance of intensity-modulated radiotherapy using dynamic multileaf collimator: Strategy for large-scale implementation for the treatment of carcinoma of the prostate
    • C. Burman, C. S. Chui, G. Kutcher, S. Leibel, M. Zelefsky, T. LoSasso, S. Spirou, Q. Wu, J. Yang, J. Stein, R. Mohan, Z. Fuks, and C. C. Ling, "Planning, delivery, and quality assurance of intensity-modulated radiotherapy using dynamic multileaf collimator: strategy for large-scale implementation for the treatment of carcinoma of the prostate," Int. J. Radiat. Oncol., Biol., Phys. 39, 863-873 (1997).
    • (1997) Int. J. Radiat. Oncol., Biol., Phys. , vol.39 , pp. 863-873
    • Burman, C.1    Chui, C.S.2    Kutcher, G.3    Leibel, S.4    Zelefsky, M.5    LoSasso, T.6    Spirou, S.7    Wu, Q.8    Yang, J.9    Stein, J.10    Mohan, R.11    Fuks, Z.12    Ling, C.C.13
  • 12
    • 0034063644 scopus 로고    scopus 로고
    • Monitor unit calculation for an intensity modulated photon field by a simple scatter-summation algorithm
    • L. Xing, Y. Chen, G. Luxton, J. G. Li, and A. L. Boyer, "Monitor unit calculation for an intensity modulated photon field by a simple scatter-summation algorithm," Phys. Med. Biol. 45, N1-N7 (2000).
    • (2000) Phys. Med. Biol. , vol.45
    • Xing, L.1    Chen, Y.2    Luxton, G.3    Li, J.G.4    Boyer, A.L.5
  • 14
    • 0034085523 scopus 로고    scopus 로고
    • The impact of fluctuations in intensity patterns on the number of monitor units and the quality and accuracy of intensity modulated radiotherapy
    • R. Mohan, M. Arnfield, S. Tong, Q. Wu, and J. Siebers, "The impact of fluctuations in intensity patterns on the number of monitor units and the quality and accuracy of intensity modulated radiotherapy," Med. Phys. 27, 1226-1237 (2000).
    • (2000) Med. Phys. , vol.27 , pp. 1226-1237
    • Mohan, R.1    Arnfield, M.2    Tong, S.3    Wu, Q.4    Siebers, J.5
  • 16
    • 0033796474 scopus 로고    scopus 로고
    • Computer verification of fluence map for intensity modulated radiation therapy
    • L. Xing and J. G. Li, "Computer verification of fluence map for intensity modulated radiation therapy," Med. Phys. 27, 2084-2092 (2000).
    • (2000) Med. Phys. , vol.27 , pp. 2084-2092
    • Xing, L.1    Li, J.G.2
  • 17
    • 0031762329 scopus 로고    scopus 로고
    • Physical and dosimetric aspects of a multileaf collimation system used in the dynamic mode for implementing intensity modulated radiotherapy
    • T. LoSasso, C. S. Chui, and C. C. Ling, "Physical and dosimetric aspects of a multileaf collimation system used in the dynamic mode for implementing intensity modulated radiotherapy," Med. Phys. 25, 1919-1927 (1998).
    • (1998) Med. Phys. , vol.25 , pp. 1919-1927
    • LoSasso, T.1    Chui, C.S.2    Ling, C.C.3
  • 18
    • 0034083357 scopus 로고    scopus 로고
    • Requirements for leaf position accuracy for dynamic multileaf
    • G. J. Budgell, J. H. L. Mott, P. C. Williams, and K. J. Brown, "Requirements for leaf position accuracy for dynamic multileaf," Phys. Med. Biol. 45, 1211-1227 (2000).
    • (2000) Phys. Med. Biol. , vol.45 , pp. 1211-1227
    • Budgell, G.J.1    Mott, J.H.L.2    Williams, P.C.3    Brown, K.J.4
  • 20
    • 0343773372 scopus 로고    scopus 로고
    • Characterization of a commercial multileaf collimator used for intensity modulated radiation therapy
    • D. A. Low, J. W. Sohn, E. E. Klein, J. Markman, S. Mutic, and J. F. Dempsey, "Characterization of a commercial multileaf collimator used for intensity modulated radiation therapy," Med. Phys. 28, 752-756 (2001).
    • (2001) Med. Phys. , vol.28 , pp. 752-756
    • Low, D.A.1    Sohn, J.W.2    Klein, E.E.3    Markman, J.4    Mutic, S.5    Dempsey, J.F.6
  • 21
    • 0035185056 scopus 로고    scopus 로고
    • Method of identifying dynamic multileaf collimator irradiation that is highly sensitive to a systematic MLC calibration error
    • P. Zygmanski and J. H. Kung, "Method of identifying dynamic multileaf collimator irradiation that is highly sensitive to a systematic MLC calibration error," Med. Phys. 28, 2220-2226 (2001).
    • (2001) Med. Phys. , vol.28 , pp. 2220-2226
    • Zygmanski, P.1    Kung, J.H.2
  • 23
    • 0029931223 scopus 로고    scopus 로고
    • Testing of dynamic multileaf collimation
    • C. S. Chui, S. Spirou, and T. LoSasso, "Testing of dynamic multileaf collimation," Med. Phys. 23, 635-641 (1996).
    • (1996) Med. Phys. , vol.23 , pp. 635-641
    • Chui, C.S.1    Spirou, S.2    LoSasso, T.3
  • 24
    • 0035192124 scopus 로고    scopus 로고
    • Comprehensive quality assurance for the delivery of intensity modulated radiotherapy with a multileaf collimator used in the dynamic mode
    • T. LoSasso, C. S. Chui, and C. C. Ling, "Comprehensive quality assurance for the delivery of intensity modulated radiotherapy with a multileaf collimator used in the dynamic mode," Med. Phys. 28, 2209-2219 (2001).
    • (2001) Med. Phys. , vol.28 , pp. 2209-2219
    • LoSasso, T.1    Chui, C.S.2    Ling, C.C.3
  • 25
    • 0033965317 scopus 로고    scopus 로고
    • Verification of dynamic multileaf collimation using an electronic portal imaging device
    • H. V. James, S. Atherton, G. J. Budgell, M. C. Kirby, and P. C. Williams, "Verification of dynamic multileaf collimation using an electronic portal imaging device," Phys. Med. Biol. 45, 495-509 (2000).
    • (2000) Phys. Med. Biol. , vol.45 , pp. 495-509
    • James, H.V.1    Atherton, S.2    Budgell, G.J.3    Kirby, M.C.4    Williams, P.C.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.