-
1
-
-
0028256435
-
X-ray field compensation with multileaf collimators
-
T. R. Bortfeld, D. L. Kahler, T. J. Waldron, and A. L. Boyer, "X-ray field compensation with multileaf collimators," Int. J. Radiat. Oncol., Biol., Phys. 28, 723-730 (1994).
-
(1994)
Int. J. Radiat. Oncol., Biol., Phys.
, vol.28
, pp. 723-730
-
-
Bortfeld, T.R.1
Kahler, D.L.2
Waldron, T.J.3
Boyer, A.L.4
-
2
-
-
0031834130
-
An optimized leaf-setting algorithm for beam intensity modulation using dynamic multileaf collimators
-
L. Ma, A. L. Boyer, L. Xing, and C. M. Ma, "An optimized leaf-setting algorithm for beam intensity modulation using dynamic multileaf collimators," Phys. Med. Biol. 43, 1629-1643 (1998).
-
(1998)
Phys. Med. Biol.
, vol.43
, pp. 1629-1643
-
-
Ma, L.1
Boyer, A.L.2
Xing, L.3
Ma, C.M.4
-
3
-
-
0031868367
-
Multileaf collimator leaf sequencing algorithm for intensity modulated beams with multiple static segments
-
P. Xia and L. J. Verhey, "Multileaf collimator leaf sequencing algorithm for intensity modulated beams with multiple static segments," Med. Phys. 25, 1424-1434 (1998).
-
(1998)
Med. Phys.
, vol.25
, pp. 1424-1434
-
-
Xia, P.1
Verhey, L.J.2
-
4
-
-
0032736686
-
Comparison of algorithms for multileaf collimator field segmentation
-
W. Que, "Comparison of algorithms for multileaf collimator field segmentation," Med. Phys. 26, 2390-2396 (1999).
-
(1999)
Med. Phys.
, vol.26
, pp. 2390-2396
-
-
Que, W.1
-
5
-
-
0035664146
-
Delivery of intensity-modulated radiation therapy with a conventional multileaf collimator: Comparison of dynamic and segmental methods
-
C. S. Chui, M. F. Chan, E. Yorke, S. Spirou, and C. C. Ling, "Delivery of intensity-modulated radiation therapy with a conventional multileaf collimator: Comparison of dynamic and segmental methods," Med. Phys. 28, 2441-2449 (2001).
-
(2001)
Med. Phys.
, vol.28
, pp. 2441-2449
-
-
Chui, C.S.1
Chan, M.F.2
Yorke, E.3
Spirou, S.4
Ling, C.C.5
-
6
-
-
0026661373
-
The generation of intensity-modulated fields for conformal radiotherapy by dynamic collimation
-
D. J. Convey and M. E. Rosenbloom, "The generation of intensity-modulated fields for conformal radiotherapy by dynamic collimation," Phys. Med. Biol. 37, 1359-1374 (1992).
-
(1992)
Phys. Med. Biol.
, vol.37
, pp. 1359-1374
-
-
Convey, D.J.1
Rosenbloom, M.E.2
-
7
-
-
0028144837
-
Generation of arbitrary intensity profiles by dynamic jaws or multileaf collimators
-
S. V. Spirou and C. S. Chui, "Generation of arbitrary intensity profiles by dynamic jaws or multileaf collimators," Med. Phys. 21, 1031-1041 (1994).
-
(1994)
Med. Phys.
, vol.21
, pp. 1031-1041
-
-
Spirou, S.V.1
Chui, C.S.2
-
8
-
-
0028153801
-
An analytical solution for the dynamic control of multileaf collimators
-
R. Svensson, P. Kallman, and A. Brahme, "An analytical solution for the dynamic control of multileaf collimators," Phys. Med. Biol. 39, 37-61 (1994).
-
(1994)
Phys. Med. Biol.
, vol.39
, pp. 37-61
-
-
Svensson, R.1
Kallman, P.2
Brahme, A.3
-
9
-
-
0028077046
-
Dynamic x-ray compensation for conformal radiotherapy by means of multi-leaf collimation
-
R. Stein, T. Bortfeld, B. Dorschel, and W. Schlegel, "Dynamic x-ray compensation for conformal radiotherapy by means of multi-leaf collimation," Radiother. Oncol. 32, 163-173 (1994).
-
(1994)
Radiother. Oncol.
, vol.32
, pp. 163-173
-
-
Stein, R.1
Bortfeld, T.2
Dorschel, B.3
Schlegel, W.4
-
10
-
-
0030199938
-
Conformal radiation treatment of prostate cancer using inversely-planned intensity-modulated photon beams produced with dynamic multileaf collimation
-
C. C. Ling, C. Burman, C. S. Chui, G. J. Kutcher, S. A. Leibel, T. LoSasso, and R. Mohan, "Conformal radiation treatment of prostate cancer using inversely-planned intensity-modulated photon beams produced with dynamic multileaf collimation," Int. J. Radiat. Oncol., Biol., Phys. 35, 721-730 (1996).
-
(1996)
Int. J. Radiat. Oncol., Biol., Phys.
, vol.35
, pp. 721-730
-
-
Ling, C.C.1
Burman, C.2
Chui, C.S.3
Kutcher, G.J.4
Leibel, S.A.5
LoSasso, T.6
Mohan, R.7
-
11
-
-
0030661596
-
Planning, delivery, and quality assurance of intensity-modulated radiotherapy using dynamic multileaf collimator: Strategy for large-scale implementation for the treatment of carcinoma of the prostate
-
C. Burman, C. S. Chui, G. Kutcher, S. Leibel, M. Zelefsky, T. LoSasso, S. Spirou, Q. Wu, J. Yang, J. Stein, R. Mohan, Z. Fuks, and C. C. Ling, "Planning, delivery, and quality assurance of intensity-modulated radiotherapy using dynamic multileaf collimator: strategy for large-scale implementation for the treatment of carcinoma of the prostate," Int. J. Radiat. Oncol., Biol., Phys. 39, 863-873 (1997).
-
(1997)
Int. J. Radiat. Oncol., Biol., Phys.
, vol.39
, pp. 863-873
-
-
Burman, C.1
Chui, C.S.2
Kutcher, G.3
Leibel, S.4
Zelefsky, M.5
LoSasso, T.6
Spirou, S.7
Wu, Q.8
Yang, J.9
Stein, J.10
Mohan, R.11
Fuks, Z.12
Ling, C.C.13
-
12
-
-
0034063644
-
Monitor unit calculation for an intensity modulated photon field by a simple scatter-summation algorithm
-
L. Xing, Y. Chen, G. Luxton, J. G. Li, and A. L. Boyer, "Monitor unit calculation for an intensity modulated photon field by a simple scatter-summation algorithm," Phys. Med. Biol. 45, N1-N7 (2000).
-
(2000)
Phys. Med. Biol.
, vol.45
-
-
Xing, L.1
Chen, Y.2
Luxton, G.3
Li, J.G.4
Boyer, A.L.5
-
13
-
-
0029865277
-
Dosimetric verification of intensity-modulated fields
-
X. Wang, S. Spirou, T. LoSasso, J. Stein, C. S. Chui, and B. Mohan, "Dosimetric verification of intensity-modulated fields," Med. Phys. 23, 317-327 (1996).
-
(1996)
Med. Phys.
, vol.23
, pp. 317-327
-
-
Wang, X.1
Spirou, S.2
LoSasso, T.3
Stein, J.4
Chui, C.S.5
Mohan, B.6
-
14
-
-
0034085523
-
The impact of fluctuations in intensity patterns on the number of monitor units and the quality and accuracy of intensity modulated radiotherapy
-
R. Mohan, M. Arnfield, S. Tong, Q. Wu, and J. Siebers, "The impact of fluctuations in intensity patterns on the number of monitor units and the quality and accuracy of intensity modulated radiotherapy," Med. Phys. 27, 1226-1237 (2000).
-
(2000)
Med. Phys.
, vol.27
, pp. 1226-1237
-
-
Mohan, R.1
Arnfield, M.2
Tong, S.3
Wu, Q.4
Siebers, J.5
-
15
-
-
0034176959
-
Relative profile and dose verification of intensity modulated radiation therapy
-
J. Chang, G. S. Mageras, C. S. Chui, C. C. Ling, and R. Mohan, "Relative profile and dose verification of intensity modulated radiation therapy," Int. J. Radiat. Oncol., Biol., Phys. 47, 231-240 (2000).
-
(2000)
Int. J. Radiat. Oncol., Biol., Phys.
, vol.47
, pp. 231-240
-
-
Chang, J.1
Mageras, G.S.2
Chui, C.S.3
Ling, C.C.4
Mohan, R.5
-
16
-
-
0033796474
-
Computer verification of fluence map for intensity modulated radiation therapy
-
L. Xing and J. G. Li, "Computer verification of fluence map for intensity modulated radiation therapy," Med. Phys. 27, 2084-2092 (2000).
-
(2000)
Med. Phys.
, vol.27
, pp. 2084-2092
-
-
Xing, L.1
Li, J.G.2
-
17
-
-
0031762329
-
Physical and dosimetric aspects of a multileaf collimation system used in the dynamic mode for implementing intensity modulated radiotherapy
-
T. LoSasso, C. S. Chui, and C. C. Ling, "Physical and dosimetric aspects of a multileaf collimation system used in the dynamic mode for implementing intensity modulated radiotherapy," Med. Phys. 25, 1919-1927 (1998).
-
(1998)
Med. Phys.
, vol.25
, pp. 1919-1927
-
-
LoSasso, T.1
Chui, C.S.2
Ling, C.C.3
-
18
-
-
0034083357
-
Requirements for leaf position accuracy for dynamic multileaf
-
G. J. Budgell, J. H. L. Mott, P. C. Williams, and K. J. Brown, "Requirements for leaf position accuracy for dynamic multileaf," Phys. Med. Biol. 45, 1211-1227 (2000).
-
(2000)
Phys. Med. Biol.
, vol.45
, pp. 1211-1227
-
-
Budgell, G.J.1
Mott, J.H.L.2
Williams, P.C.3
Brown, K.J.4
-
19
-
-
0031696075
-
Quality assurance of the dose delivered by small radiation segments
-
V. N. Hansen, P. M. Evans, G. J. Budgell, J. H. L. Mott, P. C. Williams, M. Brugmans, F. W. Wittkämper, and B. Mijnheer, "Quality assurance of the dose delivered by small radiation segments," Phys. Med. Biol. 43, 2665-2675 (1998).
-
(1998)
Phys. Med. Biol.
, vol.43
, pp. 2665-2675
-
-
Hansen, V.N.1
Evans, P.M.2
Budgell, G.J.3
Mott, J.H.L.4
Williams, P.C.5
Brugmans, M.6
Wittkämper, F.W.7
Mijnheer, B.8
-
20
-
-
0343773372
-
Characterization of a commercial multileaf collimator used for intensity modulated radiation therapy
-
D. A. Low, J. W. Sohn, E. E. Klein, J. Markman, S. Mutic, and J. F. Dempsey, "Characterization of a commercial multileaf collimator used for intensity modulated radiation therapy," Med. Phys. 28, 752-756 (2001).
-
(2001)
Med. Phys.
, vol.28
, pp. 752-756
-
-
Low, D.A.1
Sohn, J.W.2
Klein, E.E.3
Markman, J.4
Mutic, S.5
Dempsey, J.F.6
-
21
-
-
0035185056
-
Method of identifying dynamic multileaf collimator irradiation that is highly sensitive to a systematic MLC calibration error
-
P. Zygmanski and J. H. Kung, "Method of identifying dynamic multileaf collimator irradiation that is highly sensitive to a systematic MLC calibration error," Med. Phys. 28, 2220-2226 (2001).
-
(2001)
Med. Phys.
, vol.28
, pp. 2220-2226
-
-
Zygmanski, P.1
Kung, J.H.2
-
22
-
-
0035180383
-
Calibration and quality assurance for rounded leaf-end systems
-
M. N. Graves, A. V. Thompson, M. K. Martel, D. L. McShan, and B. A. Fraass, "Calibration and quality assurance for rounded leaf-end systems," Med. Phys. 28, 2227-2233 (2001).
-
(2001)
Med. Phys.
, vol.28
, pp. 2227-2233
-
-
Graves, M.N.1
Thompson, A.V.2
Martel, M.K.3
McShan, D.L.4
Fraass, B.A.5
-
23
-
-
0029931223
-
Testing of dynamic multileaf collimation
-
C. S. Chui, S. Spirou, and T. LoSasso, "Testing of dynamic multileaf collimation," Med. Phys. 23, 635-641 (1996).
-
(1996)
Med. Phys.
, vol.23
, pp. 635-641
-
-
Chui, C.S.1
Spirou, S.2
LoSasso, T.3
-
24
-
-
0035192124
-
Comprehensive quality assurance for the delivery of intensity modulated radiotherapy with a multileaf collimator used in the dynamic mode
-
T. LoSasso, C. S. Chui, and C. C. Ling, "Comprehensive quality assurance for the delivery of intensity modulated radiotherapy with a multileaf collimator used in the dynamic mode," Med. Phys. 28, 2209-2219 (2001).
-
(2001)
Med. Phys.
, vol.28
, pp. 2209-2219
-
-
LoSasso, T.1
Chui, C.S.2
Ling, C.C.3
-
25
-
-
0033965317
-
Verification of dynamic multileaf collimation using an electronic portal imaging device
-
H. V. James, S. Atherton, G. J. Budgell, M. C. Kirby, and P. C. Williams, "Verification of dynamic multileaf collimation using an electronic portal imaging device," Phys. Med. Biol. 45, 495-509 (2000).
-
(2000)
Phys. Med. Biol.
, vol.45
, pp. 495-509
-
-
James, H.V.1
Atherton, S.2
Budgell, G.J.3
Kirby, M.C.4
Williams, P.C.5
|