1
-
-
0024237042
-
Standard compensators for ENT therapy fields
-
Clark B.G., Evans M.D.C. Standard compensators for ENT therapy fields. Med. Dosim. 13:1988;173-177.
-
(1988)
Med. Dosim.
, vol.13
, pp. 173-177
-
-
Clark, B.G.1
Evans, M.D.C.2
-
2
-
-
0019833340
-
Improved methods for the design of tissue compensators
-
Shragge P.C., Patterson M.S. Improved methods for the design of tissue compensators. Med. Phys. 8:1981;885-891.
-
(1981)
Med. Phys.
, vol.8
, pp. 885-891
-
-
Shragge, P.C.1
Patterson, M.S.2
-
3
-
-
0020564494
-
A note on designing tissue compensators for parallel opposed fields
-
Renner W.D., O'Connor T.P., Bermudez N.M. A note on designing tissue compensators for parallel opposed fields. Med. Phys. 10:1983;483-486.
-
(1983)
Med. Phys.
, vol.10
, pp. 483-486
-
-
Renner, W.D.1
O'Connor, T.P.2
Bermudez, N.M.3
-
4
-
-
0019992678
-
Compensating filters for high energy x rays
-
Boyer A.L. Compensating filters for high energy x rays. Med. Phys. 9:1982;429-433.
-
(1982)
Med. Phys.
, vol.9
, pp. 429-433
-
-
Boyer, A.L.1
-
5
-
-
0024527010
-
Limitation of retracted missing tissue compensators: An experimental analysis
-
Robinson D.M., Scrimger J.W. Limitation of retracted missing tissue compensators An experimental analysis. Med. Dosim. 14:1989;49-54.
-
(1989)
Med. Dosim.
, vol.14
, pp. 49-54
-
-
Robinson, D.M.1
Scrimger, J.W.2
-
6
-
-
0026806134
-
Missing tissue compensators: Evaluation and optimization of a commercial system
-
Ansbacher W., Robinson D.M., Scrimger J.W. Missing tissue compensators Evaluation and optimization of a commercial system. Med. Phys. 19:1992;1267-1272.
-
(1992)
Med. Phys.
, vol.19
, pp. 1267-1272
-
-
Ansbacher, W.1
Robinson, D.M.2
Scrimger, J.W.3
-
7
-
-
0022645280
-
Scattered photons produced by beam-modifying filters
-
Huang P., Chin L.M., Bjärngard B.E. Scattered photons produced by beam-modifying filters. Med. Phys. 13:1986;57-63.
-
(1986)
Med. Phys.
, vol.13
, pp. 57-63
-
-
Huang, P.1
Chin, L.M.2
Bjärngard, B.E.3
-
8
-
-
0027192363
-
A technique for the evaluation of a missing tissue compensator system
-
Chu T., Lee K., Dunscombe P. A technique for the evaluation of a missing tissue compensator system. Med. Phys. 20:1993;713-716.
-
(1993)
Med. Phys.
, vol.20
, pp. 713-716
-
-
Chu, T.1
Lee, K.2
Dunscombe, P.3
-
9
-
-
0029929964
-
Verification of milled two-dimensional photon compensating filters using an electronic portal imaging device
-
Low D.A., Li Z., Klein E.E. Verification of milled two-dimensional photon compensating filters using an electronic portal imaging device. Med. Phys. 23:1996;929-938.
-
(1996)
Med. Phys.
, vol.23
, pp. 929-938
-
-
Low, D.A.1
Li, Z.2
Klein, E.E.3
-
10
-
-
0031762874
-
Evaluation of optimized compensators on a 3D planning system
-
Basran P.S., Ansbacher W., Field G.C., Murray B.R. Evaluation of optimized compensators on a 3D planning system. Med. Phys. 25:1998;1837-1844.
-
(1998)
Med. Phys.
, vol.25
, pp. 1837-1844
-
-
Basran, P.S.1
Ansbacher, W.2
Field, G.C.3
Murray, B.R.4
-
11
-
-
0026806134
-
Missing tissue compensators: Evaluation and optimization of a commercial system
-
Ansbacher W., Robinson D.M., Scrimger J.W. Missing tissue compensators Evaluation and optimization of a commercial system. Med. Phys. 19:1992;1267-1272.
-
(1992)
Med. Phys.
, vol.19
, pp. 1267-1272
-
-
Ansbacher, W.1
Robinson, D.M.2
Scrimger, J.W.3
-
12
-
-
0000280904
-
Clinical implementation of intensity-modulated treatments using compensators: Dosimetric verification
-
Levegrün S., Hartwig K., Oelfke U., et al. Clinical implementation of intensity-modulated treatments using compensators Dosimetric verification. Med. Phys. 25:1998;A150.
-
(1998)
Med. Phys.
, vol.25
-
-
Levegrün, S.1
Hartwig, K.2
Oelfke, U.3
-
13
-
-
0031805413
-
On compensator design for photon beam intensity-modulated conformal therapy
-
Jiang S.B., Ayyangar K.M. On compensator design for photon beam intensity-modulated conformal therapy. Med. Phys. 25:1998;668-675.
-
(1998)
Med. Phys.
, vol.25
, pp. 668-675
-
-
Jiang, S.B.1
Ayyangar, K.M.2
-
14
-
-
0017846995
-
Variation in depth dose data between open and wedge fields for 4 MV x-rays
-
Sewchand W., Khan F.M., Williamson J. Variation in depth dose data between open and wedge fields for 4 MV x-rays. Radiology. 3:1978;789-792.
-
(1978)
Radiology
, vol.3
, pp. 789-792
-
-
Sewchand, W.1
Khan, F.M.2
Williamson, J.3
-
15
-
-
0028880490
-
The influence of scatter on the design of optimized intensity modulations
-
Chen Z., Wang X., Bortfeld T., Mohan R., Reinstein L. The influence of scatter on the design of optimized intensity modulations. Med Phys. 22:1995;1727-1733.
-
(1995)
Med Phys
, vol.22
, pp. 1727-1733
-
-
Chen, Z.1
Wang, X.2
Bortfeld, T.3
Mohan, R.4
Reinstein, L.5
|