-
1
-
-
0023840270
-
Comparative analysis of ankle arthroplasty versus ankle arthrodesis
-
McGuire MR, Kyle RF, Gustillo RB, Premer RF. Comparative analysis of ankle arthroplasty versus ankle arthrodesis. Clin Orthop 1988;226:174-181.
-
(1988)
Clin Orthop
, vol.226
, pp. 174-181
-
-
McGuire, M.R.1
Kyle, R.F.2
Gustillo, R.B.3
Premer, R.F.4
-
2
-
-
0018715606
-
Clinical study of total ankle replacement with gait analysis
-
Demottaz JD, Mazur JM, Thomas WH, Sledge CB, Simon SR. Clinical study of total ankle replacement with gait analysis. J Bone Joint Surg Am 1979;61:976-988.
-
(1979)
J Bone Joint Surg Am
, vol.61
, pp. 976-988
-
-
Demottaz, J.D.1
Mazur, J.M.2
Thomas, W.H.3
Sledge, C.B.4
Simon, S.R.5
-
3
-
-
0023888628
-
Total ankle arthroplasty in rheumatoid arthritis: A long term follow-up study
-
Unger AS, Inglis AE, Mow CS, Figgie HE. Total ankle arthroplasty in rheumatoid arthritis: A long term follow-up study. Foot Ankle 1988;8:173-179.
-
(1988)
Foot Ankle
, vol.8
, pp. 173-179
-
-
Unger, A.S.1
Inglis, A.E.2
Mow, C.S.3
Figgie, H.E.4
-
4
-
-
0026795141
-
Long-term follow up of the conaxial (Beck-Steffee) total ankle arthroplasty
-
Wynn AH, Wilde AH. Long-term follow up of the conaxial (Beck-Steffee) total ankle arthroplasty. Foot Ankle Surg 1992; 3:303-306.
-
(1992)
Foot Ankle Surg
, vol.3
, pp. 303-306
-
-
Wynn, A.H.1
Wilde, A.H.2
-
5
-
-
0030475271
-
Clinical results of the Mayo total ankle arthroplasty
-
Kitaoka HB, Patzer GL. Clinical results of the Mayo total ankle arthroplasty. J Bone Joint Surg Am 1996;78:1658-1664.
-
(1996)
J Bone Joint Surg Am
, vol.78
, pp. 1658-1664
-
-
Kitaoka, H.B.1
Patzer, G.L.2
-
6
-
-
0001201292
-
Total ankle replacement. Review and critical analysis of the current status
-
Bauer G, Eberhardt O, Rosenbaum D, Claes L. Total ankle replacement. Review and critical analysis of the current status. Foot Ankle Surg 1996;2:119-126.
-
(1996)
Foot Ankle Surg
, vol.2
, pp. 119-126
-
-
Bauer, G.1
Eberhardt, O.2
Rosenbaum, D.3
Claes, L.4
-
8
-
-
0023257380
-
Total ankle arthroplasty using biological fixation components compared to ankle arthrodesis
-
Scholz KC. Total ankle arthroplasty using biological fixation components compared to ankle arthrodesis. Orthopedics 1987; 10:125-131.
-
(1987)
Orthopedics
, vol.10
, pp. 125-131
-
-
Scholz, K.C.1
-
9
-
-
0023916789
-
New Jersey low contact stress total ankle replacement: Biomechanical rationale and review of 23 cementless cases
-
Buechel FF, Pappas MJ, Iorio LJ. New Jersey low contact stress total ankle replacement: Biomechanical rationale and review of 23 cementless cases. Foot Ankle 1988;6:279-290.
-
(1988)
Foot Ankle
, vol.6
, pp. 279-290
-
-
Buechel, F.F.1
Pappas, M.J.2
Iorio, L.J.3
-
10
-
-
33947709818
-
-
rationale: The Buechel-Pappas ankle replacement system. Available at
-
Pappas MJ, Buechel FF. Biomechanics and design rationale: The Buechel-Pappas ankle replacement system. Available at: www.endotec.com.
-
Biomechanics and design
-
-
Pappas, M.J.1
Buechel, F.F.2
-
11
-
-
0028128515
-
The ankle joint prosthetic replacement: Clinical performance and research challenges
-
Lewis G. The ankle joint prosthetic replacement: Clinical performance and research challenges. Foot Ankle Int 1994;15: 471-476.
-
(1994)
Foot Ankle Int
, vol.15
, pp. 471-476
-
-
Lewis, G.1
-
12
-
-
33947625411
-
Cementless meniscal bearing (shallow sulcus) TAR: Multicenter clinical trial of 237
-
Unpublished
-
Keblish PK, Buechel FF, Fenning JB. Cementless meniscal bearing (shallow sulcus) TAR: Multicenter clinical trial of 237. Unpublished.
-
-
-
Keblish, P.K.1
Buechel, F.F.2
Fenning, J.B.3
-
13
-
-
0036116831
-
Investigation of wear of knee prostheses in a new displacement/force-controlled simulator
-
Barnett PI, McEwen HMJ, Auger DD, Stone MH, Ingham E, Fisher J. Investigation of wear of knee prostheses in a new displacement/force-controlled simulator. Proc Inst Mech Eng J Eng Med 2002;216:51-61.
-
(2002)
Proc Inst Mech Eng J Eng Med
, vol.216
, pp. 51-61
-
-
Barnett, P.I.1
McEwen, H.M.J.2
Auger, D.D.3
Stone, M.H.4
Ingham, E.5
Fisher, J.6
-
14
-
-
0017688293
-
Force and motion analysis of the normal, diseased, and prosthetic ankle joint
-
Stauffer RN, Chao EYS, Brewster RC. Force and motion analysis of the normal, diseased, and prosthetic ankle joint. Clin Orthop 1977;127:189-196.
-
(1977)
Clin Orthop
, vol.127
, pp. 189-196
-
-
Stauffer, R.N.1
Chao, E.Y.S.2
Brewster, R.C.3
-
15
-
-
0020735292
-
Biomechanical design of the total ankle prosthesis
-
Calderale PM, Garro A, Barbiero R, Fasolio G, Pipino F. Biomechanical design of the total ankle prosthesis. Eng Med 1983;12:69-80.
-
(1983)
Eng Med
, vol.12
, pp. 69-80
-
-
Calderale, P.M.1
Garro, A.2
Barbiero, R.3
Fasolio, G.4
Pipino, F.5
-
16
-
-
0015021876
-
Kinematic measurements in the study of human walking
-
Lamoreux LW. Kinematic measurements in the study of human walking. Bull Prosthet Res 1971;10:3-84.
-
(1971)
Bull Prosthet Res
, vol.10
, pp. 3-84
-
-
Lamoreux, L.W.1
-
18
-
-
0033928533
-
Total ankle replacement: Review of the designs and of the current status
-
Giannini S, Leardini A, O'Connor JJ. Total ankle replacement: Review of the designs and of the current status. Foot Ankle Surg 2000;6:77-88.
-
(2000)
Foot Ankle Surg
, vol.6
, pp. 77-88
-
-
Giannini, S.1
Leardini, A.2
O'Connor, J.J.3
-
19
-
-
0034886659
-
Geometry and mechanics of the human ankle complex and ankle prosthesis design
-
Leardini A. Geometry and mechanics of the human ankle complex and ankle prosthesis design. Clin Biomech 2001;16: 706-709.
-
(2001)
Clin Biomech
, vol.16
, pp. 706-709
-
-
Leardini, A.1
-
20
-
-
10444261188
-
The influence of design, materials and kinematics on the in vitro wear of total knee replacements
-
McEwen HMJ, Barnett PI, Bell CJ, Farrar R, Auger DD, Stone MH, Fisher J. The influence of design, materials and kinematics on the in vitro wear of total knee replacements. J Biomech 2005;38:357-365.
-
(2005)
J Biomech
, vol.38
, pp. 357-365
-
-
McEwen, H.M.J.1
Barnett, P.I.2
Bell, C.J.3
Farrar, R.4
Auger, D.D.5
Stone, M.H.6
Fisher, J.7
-
21
-
-
33947622424
-
The influence of RGCA TiN coating on reduction of UHMWPE wear in knee prostheses
-
Kamali A, Farrar R, Hatto P, Stone MH, Fisher J. The influence of RGCA TiN coating on reduction of UHMWPE wear in knee prostheses. Trans Orthop Res Soc 2004;29:1481.
-
(2004)
Trans Orthop Res Soc
, vol.29
, pp. 1481
-
-
Kamali, A.1
Farrar, R.2
Hatto, P.3
Stone, M.H.4
Fisher, J.5
-
22
-
-
1542268872
-
The influence of molecular weight, crosslinking and counterface roughness on TNF-α production by macrophages in response to ultra high molecular weight polyethylene particles
-
Ingram JH, Stone MH, Fisher J, Ingham E. The influence of molecular weight, crosslinking and counterface roughness on TNF-α production by macrophages in response to ultra high molecular weight polyethylene particles. Biomaterials 2004;25: 3511-3522.
-
(2004)
Biomaterials
, vol.25
, pp. 3511-3522
-
-
Ingram, J.H.1
Stone, M.H.2
Fisher, J.3
Ingham, E.4
-
23
-
-
0031259388
-
The influence of stress conditions on the wear of UHMWPE for total joint replacements
-
Barbour PSM, Barton DC, Fisher J. The influence of stress conditions on the wear of UHMWPE for total joint replacements. J Mater Sci Mater Med 1997;8:603-611.
-
(1997)
J Mater Sci Mater Med
, vol.8
, pp. 603-611
-
-
Barbour, P.S.M.1
Barton, D.C.2
Fisher, J.3
-
24
-
-
8644278179
-
Is the wear factor in total joint replacements dependent on the nominal contact stress in ultrahigh molecular weight polyethylene contacts?
-
Vassiliou K, Unsworth A. Is the wear factor in total joint replacements dependent on the nominal contact stress in ultrahigh molecular weight polyethylene contacts? Proc Inst Mech Eng J Eng Med 2004;218:101-107.
-
(2004)
Proc Inst Mech Eng J Eng Med
, vol.218
, pp. 101-107
-
-
Vassiliou, K.1
Unsworth, A.2
-
25
-
-
0347516482
-
Microscopic asperity contact and deformation of ultrahigh molecular weight polyethylene bearing surfaces
-
Wang FC, Jin ZM, McEwen HMJ, Fisher J. Microscopic asperity contact and deformation of ultrahigh molecular weight polyethylene bearing surfaces. Proc Inst Mech Eng J Eng Med 2003;217:477-490.
-
(2003)
Proc Inst Mech Eng J Eng Med
, vol.217
, pp. 477-490
-
-
Wang, F.C.1
Jin, Z.M.2
McEwen, H.M.J.3
Fisher, J.4
-
26
-
-
4344701495
-
The human ankle joint during walking, implications for the design of biomimetic ankle prostheses
-
Hansen AH, Childress DS, Miff SC, Gard SA, Mesplay KP. The human ankle joint during walking, implications for the design of biomimetic ankle prostheses. J Biomech 2004;37: 1467-1474.
-
(2004)
J Biomech
, vol.37
, pp. 1467-1474
-
-
Hansen, A.H.1
Childress, D.S.2
Miff, S.C.3
Gard, S.A.4
Mesplay, K.P.5
|