메뉴 건너뛰기




Volumn 19, Issue 4, 2003, Pages 401-409

Glucose sensor for flow injection analysis of serum glucose based on immobilization of glucose oxidase in titania sol-gel membrane

Author keywords

Biosensors; Electrocatalysis; Flow injection analysis; Glucose; Glucose oxidase; Sol gel; Titania; Vapor deposition

Indexed keywords

ENZYMES; GLUCOSE; MASS TRANSFER; SOL-GELS; VAPOR DEPOSITION;

EID: 0242486387     PISSN: 09565663     EISSN: None     Source Type: Journal    
DOI: 10.1016/S0956-5663(03)00199-4     Document Type: Article
Times cited : (175)

References (45)
  • 1
    • 0001195207 scopus 로고
    • Characterization of mixed enzyme-mediator carbon paste electrodes
    • Amine A., Kauffmann J.M., Guilbault G.G. Characterization of mixed enzyme-mediator carbon paste electrodes. Anal. Lett. 26:1993;1281-1299.
    • (1993) Anal. Lett. , vol.26 , pp. 1281-1299
    • Amine, A.1    Kauffmann, J.M.2    Guilbault, G.G.3
  • 2
    • 0034133820 scopus 로고    scopus 로고
    • Covalent attachment of osmium complexes to glucose oxidase and the application of the resulting modified enzyme in an enzyme switch response to glucose
    • Battaglini F., Bartlett P.N., Wang J.H. Covalent attachment of osmium complexes to glucose oxidase and the application of the resulting modified enzyme in an enzyme switch response to glucose. Anal. Chem. 72:2000;502-509.
    • (2000) Anal. Chem. , vol.72 , pp. 502-509
    • Battaglini, F.1    Bartlett, P.N.2    Wang, J.H.3
  • 3
    • 0032592426 scopus 로고    scopus 로고
    • Stabilization of wired glucose oxidase anodes rotating at 1000 rpm at 37°C
    • Binyamin G., Heller A. Stabilization of wired glucose oxidase anodes rotating at 1000 rpm at 37°C. J. Electrochem. Soc. 146:1999;2965-2967.
    • (1999) J. Electrochem. Soc. , vol.146 , pp. 2965-2967
    • Binyamin, G.1    Heller, A.2
  • 5
    • 0035282173 scopus 로고    scopus 로고
    • Self-referencing ceramic-based multisite microelectrodes for detection and elimination of interferences from the measurement of L-glutamate and other analytes
    • Burmeister J.J., Gerhardt G.A. Self-referencing ceramic-based multisite microelectrodes for detection and elimination of interferences from the measurement of L-glutamate and other analytes. Anal. Chem. 73:2001;1037-1042.
    • (2001) Anal. Chem. , vol.73 , pp. 1037-1042
    • Burmeister, J.J.1    Gerhardt, G.A.2
  • 8
    • 0028489808 scopus 로고
    • Wired enzyme electrodes for amperometric determination of glucose or lactate in the presence of interfering substances
    • Chara T.J., Rajagopalan R., Heller A. Wired enzyme electrodes for amperometric determination of glucose or lactate in the presence of interfering substances. Anal. Chem. 66:1994;2451-2457.
    • (1994) Anal. Chem. , vol.66 , pp. 2451-2457
    • Chara, T.J.1    Rajagopalan, R.2    Heller, A.3
  • 9
    • 0032550685 scopus 로고    scopus 로고
    • Stability of oxidases immobilized in silica gels
    • Chen Q., Kenausis G.L., Heller A. Stability of oxidases immobilized in silica gels. J. Am. Chem. Soc. 120:1998;4582-4585.
    • (1998) J. Am. Chem. Soc. , vol.120 , pp. 4582-4585
    • Chen, Q.1    Kenausis, G.L.2    Heller, A.3
  • 10
    • 0033620585 scopus 로고    scopus 로고
    • Biomolecule immobilization on electrode surfaces by entrapment or attachment to electrochemically polymerized films. A review
    • Cosnier S. Biomolecule immobilization on electrode surfaces by entrapment or attachment to electrochemically polymerized films. A review. Biosens. Bioelectron. 14:1999;443-456.
    • (1999) Biosens. Bioelectron. , vol.14 , pp. 443-456
    • Cosnier, S.1
  • 13
    • 0034324767 scopus 로고    scopus 로고
    • Amperometric glucose biosensors based on Prussian Blue and polyaniline glucose oxidase modified electrodes
    • Garjonyte R., Malinauskas A. Amperometric glucose biosensors based on Prussian Blue and polyaniline glucose oxidase modified electrodes. Biosens. Bioelectron. 15:2000;445-451.
    • (2000) Biosens. Bioelectron. , vol.15 , pp. 445-451
    • Garjonyte, R.1    Malinauskas, A.2
  • 14
    • 85022463261 scopus 로고
    • Sol-gel vanadium pentaoxide glucose biosensor
    • Glezer V., Lev O. Sol-gel vanadium pentaoxide glucose biosensor. J. Am. Chem. Soc. 115:1993;2533-2534.
    • (1993) J. Am. Chem. Soc. , vol.115 , pp. 2533-2534
    • Glezer, V.1    Lev, O.2
  • 15
    • 0032081292 scopus 로고    scopus 로고
    • Platinum-catalyzed enzyme electrodes immobilized on gold using self-assembled layers
    • Gooding J.J., Praig V., Hall E.A.H. Platinum-catalyzed enzyme electrodes immobilized on gold using self-assembled layers. Anal. Chem. 70:1998;2396-2402.
    • (1998) Anal. Chem. , vol.70 , pp. 2396-2402
    • Gooding, J.J.1    Praig, V.2    Hall, E.A.H.3
  • 16
    • 85030941859 scopus 로고    scopus 로고
    • Heller, A., Feldman, B.J., Say, J., Vreeke, M.S., Tomasco, M.F., 1998. Small volume in vitro analyte sensor. PCT Int. Appl. WO9835225 A1 (US Pat. Appl. WO -US2652)
    • Heller, A., Feldman, B.J., Say, J., Vreeke, M.S., Tomasco, M.F., 1998. Small volume in vitro analyte sensor. PCT Int. Appl. WO9835225 A1 (US Pat. Appl. WO -US2652).
  • 17
    • 0000121726 scopus 로고    scopus 로고
    • Amperometric L-lactate biosensor: 1. Lactic acid sensing electrode containing lactate oxidase in a composite poly-lysine matrix
    • Iwuoha E.I., Rock A., Smyth M.R. Amperometric L-lactate biosensor: 1. Lactic acid sensing electrode containing lactate oxidase in a composite poly-lysine matrix. Electroanalysis. 111:1999;367-373.
    • (1999) Electroanalysis , vol.111 , pp. 367-373
    • Iwuoha, E.I.1    Rock, A.2    Smyth, M.R.3
  • 18
    • 0019035135 scopus 로고
    • Rotating ring-disk enzyme electrode for biocatalysis kinetic studies and characterization of the immobilized enzyme layer
    • Kamin R.A., Wilson G.S. Rotating ring-disk enzyme electrode for biocatalysis kinetic studies and characterization of the immobilized enzyme layer. Anal. Chem. 52:1980;1198-1205.
    • (1980) Anal. Chem. , vol.52 , pp. 1198-1205
    • Kamin, R.A.1    Wilson, G.S.2
  • 19
    • 0034994852 scopus 로고    scopus 로고
    • Recombinant Microdochium nivale carbohydrate oxidase and its application in an amperometric glucose sensor
    • Kulys J., Tetianec L., Schneider P. Recombinant Microdochium nivale carbohydrate oxidase and its application in an amperometric glucose sensor. Biosens. Bioelectron. 16:2001;319-324.
    • (2001) Biosens. Bioelectron. , vol.16 , pp. 319-324
    • Kulys, J.1    Tetianec, L.2    Schneider, P.3
  • 20
    • 0000469079 scopus 로고
    • Diagnostic applications of organically doped sol-gel porous glass
    • Lev O. Diagnostic applications of organically doped sol-gel porous glass. Analusis. 20:1992;543-553.
    • (1992) Analusis , vol.20 , pp. 543-553
    • Lev, O.1
  • 22
    • 0030579569 scopus 로고    scopus 로고
    • Silica sol-gel immobilized amperometric biosensor for hydrogen peroxide
    • Li J., Tan S.N., Ge H. Silica sol-gel immobilized amperometric biosensor for hydrogen peroxide. Anal. Chim. Acta. 335:1996;137-145.
    • (1996) Anal. Chim. Acta , vol.335 , pp. 137-145
    • Li, J.1    Tan, S.N.2    Ge, H.3
  • 23
    • 0032671297 scopus 로고    scopus 로고
    • Renewable silica sol-gel derived carbon composite based glucose biosensor
    • Li J., Chia L.S., Goh N.K., Tan S.N. Renewable silica sol-gel derived carbon composite based glucose biosensor. J. Electroanal. Chem. 460:1999;234-241.
    • (1999) J. Electroanal. Chem. , vol.460 , pp. 234-241
    • Li, J.1    Chia, L.S.2    Goh, N.K.3    Tan, S.N.4
  • 25
    • 0029644698 scopus 로고
    • Polyacrylamide-based redox polymer for connecting redox centers of enzymes to electrodes
    • Lumley-Woodyear T., Rocca P., Lindsay J., Dror Y., Freeman A., Heller A. Polyacrylamide-based redox polymer for connecting redox centers of enzymes to electrodes. Anal. Chem. 67:1995;1332-1338.
    • (1995) Anal. Chem. , vol.67 , pp. 1332-1338
    • Lumley-Woodyear, T.1    Rocca, P.2    Lindsay, J.3    Dror, Y.4    Freeman, A.5    Heller, A.6
  • 26
    • 0035356251 scopus 로고    scopus 로고
    • Construction and analytical characterization of prussian blue based carbon paste electrodes and their assembly as oxidase enzyme sensors
    • Moscone D., D'Ottavi D., Compagnone D., Palleschi G., Amine A. Construction and analytical characterization of prussian blue based carbon paste electrodes and their assembly as oxidase enzyme sensors. Anal. Chem. 73:2001;2529-2535.
    • (2001) Anal. Chem. , vol.73 , pp. 2529-2535
    • Moscone, D.1    D'ottavi, D.2    Compagnone, D.3    Palleschi, G.4    Amine, A.5
  • 27
    • 0032524461 scopus 로고    scopus 로고
    • Glucose oxidase bound to self-assembled monolayers of bis (4-pyridyl) disulfide at a gold electrode: Amperometric determination of glucose
    • Murthy A.S.N., Sharma J. Glucose oxidase bound to self-assembled monolayers of bis (4-pyridyl) disulfide at a gold electrode: amperometric determination of glucose. Anal. Chim. Acta. 363:1998;215-220.
    • (1998) Anal. Chim. Acta , vol.363 , pp. 215-220
    • Murthy, A.S.N.1    Sharma, J.2
  • 28
    • 0036134834 scopus 로고    scopus 로고
    • Ultra thin polysiloxane film composite membranes for the optimisation of amperometric oxidase enzyme electrodes
    • Myler S., Collyer S.D., Bridge K.A., Higson S.P.J. Ultra thin polysiloxane film composite membranes for the optimisation of amperometric oxidase enzyme electrodes. Biosens. Bioelectron. 17:2002;35-43.
    • (2002) Biosens. Bioelectron. , vol.17 , pp. 35-43
    • Myler, S.1    Collyer, S.D.2    Bridge, K.A.3    Higson, S.P.J.4
  • 31
    • 0034325046 scopus 로고    scopus 로고
    • Simultaneous monitoring of glucose and lactate by an interference and cross-talk free dual electrode amperometric biosensor based on electropolymerized thin films
    • Palmisano F., Rizzi R., Centonze D., Zambonin P.G. Simultaneous monitoring of glucose and lactate by an interference and cross-talk free dual electrode amperometric biosensor based on electropolymerized thin films. Biosens. Bioelectron. 15:2000;531-539.
    • (2000) Biosens. Bioelectron. , vol.15 , pp. 531-539
    • Palmisano, F.1    Rizzi, R.2    Centonze, D.3    Zambonin, P.G.4
  • 32
    • 0015214394 scopus 로고
    • Interaction of D-glucal with Aspergillus niger glucose oxidase
    • Rogers M.J., Brandt K.G. Interaction of D-glucal with Aspergillus niger glucose oxidase. Biochemistry. 10:1971;4624-4630.
    • (1971) Biochemistry , vol.10 , pp. 4624-4630
    • Rogers, M.J.1    Brandt, K.G.2
  • 33
    • 0032523526 scopus 로고    scopus 로고
    • Accuracy of the one-point in vivo calibration of wired glucose oxidase electrodes implanted in jugular veins of rats in periods of rapid rise and decline of the glucose concentration
    • Schmidtke D.W., Heller A. Accuracy of the one-point in vivo calibration of wired glucose oxidase electrodes implanted in jugular veins of rats in periods of rapid rise and decline of the glucose concentration. Anal. Chem. 70:1998;2149-2155.
    • (1998) Anal. Chem. , vol.70 , pp. 2149-2155
    • Schmidtke, D.W.1    Heller, A.2
  • 34
    • 0032746036 scopus 로고    scopus 로고
    • A laponite clay-poly (pyrrole-pyridinium) matrix for the fabrication of conductimetric microbiosensors
    • Senillou A., Jaffrezic N., Martelet C., Cosnier S. A laponite clay-poly (pyrrole-pyridinium) matrix for the fabrication of conductimetric microbiosensors. Anal. Chim. Acta. 401:1999;117-124.
    • (1999) Anal. Chim. Acta , vol.401 , pp. 117-124
    • Senillou, A.1    Jaffrezic, N.2    Martelet, C.3    Cosnier, S.4
  • 36
    • 0037169201 scopus 로고    scopus 로고
    • Bienzymatic amperometric biosensor for glucose based on polypyrrole/ceramic carbon as electrode material
    • Tian F., Zhu G. Bienzymatic amperometric biosensor for glucose based on polypyrrole/ceramic carbon as electrode material. Anal. Chim. Acta. 451:2002;251-258.
    • (2002) Anal. Chim. Acta , vol.451 , pp. 251-258
    • Tian, F.1    Zhu, G.2
  • 37
    • 0032030279 scopus 로고    scopus 로고
    • Electropolymerization of pyrrole and immobilization of glucose oxidase in a flow system: Influence of the operating conditions on analytical performance
    • Vidal J.C., Garcia E., Castillo J.R. Electropolymerization of pyrrole and immobilization of glucose oxidase in a flow system: influence of the operating conditions on analytical performance. Biosens. Bioelectron. 13:1998;371-382.
    • (1998) Biosens. Bioelectron. , vol.13 , pp. 371-382
    • Vidal, J.C.1    Garcia, E.2    Castillo, J.R.3
  • 38
    • 0032859410 scopus 로고    scopus 로고
    • Sol-gel materials for electrochemical biosensors
    • Wang J. Sol-gel materials for electrochemical biosensors. Anal. Chim. Acta. 399:1999;21-27.
    • (1999) Anal. Chim. Acta , vol.399 , pp. 21-27
    • Wang, J.1
  • 39
    • 0032520399 scopus 로고    scopus 로고
    • Sol-gel derived thick film amperometric immunosensors
    • Wang J., Pamidi P.V.A. Sol-gel derived thick film amperometric immunosensors. Anal. Chem. 70:1998;1171-1175.
    • (1998) Anal. Chem. , vol.70 , pp. 1171-1175
    • Wang, J.1    Pamidi, P.V.A.2
  • 40
    • 0035865442 scopus 로고    scopus 로고
    • Needle-type dual microsensor for the simultaneous moniting of glucose and insulin
    • Wang J., Zhang X.J. Needle-type dual microsensor for the simultaneous moniting of glucose and insulin. Anal. Chem. 73:2001;844-847.
    • (2001) Anal. Chem. , vol.73 , pp. 844-847
    • Wang, J.1    Zhang, X.J.2
  • 41
    • 0027682255 scopus 로고
    • Affinity of antifluorescein antibodies encapsulated within a transparent sol-gel glass
    • Wang R., Narang U., Prasad P.N., Bright F.V. Affinity of antifluorescein antibodies encapsulated within a transparent sol-gel glass. Anal. Chem. 65:1993;2671-2675.
    • (1993) Anal. Chem. , vol.65 , pp. 2671-2675
    • Wang, R.1    Narang, U.2    Prasad, P.N.3    Bright, F.V.4
  • 42
    • 0032129145 scopus 로고    scopus 로고
    • Amperometric glucose biosensor based on organic-inorganic hybrid material
    • Wang B., Li B., Deng Q., Dong S. Amperometric glucose biosensor based on organic-inorganic hybrid material. Anal. Chem. 70:1998;3170-3174.
    • (1998) Anal. Chem. , vol.70 , pp. 3170-3174
    • Wang, B.1    Li, B.2    Deng, Q.3    Dong, S.4
  • 43
    • 0033562450 scopus 로고    scopus 로고
    • Sol-gel thin film immobilized soybean peroxidase biosensor for amperometric determination of hydrogen peroxide in acid medium
    • Wang B., Li B., Wang Z., Xu G., Wang Q., Dong S. Sol-gel thin film immobilized soybean peroxidase biosensor for amperometric determination of hydrogen peroxide in acid medium. Anal. Chem. 71:1999;1935-1939.
    • (1999) Anal. Chem. , vol.71 , pp. 1935-1939
    • Wang, B.1    Li, B.2    Wang, Z.3    Xu, G.4    Wang, Q.5    Dong, S.6
  • 44
    • 0031937009 scopus 로고    scopus 로고
    • Amperometric biosensor with a composite memberane of sol-gel derived enzyme film and electrochemically generated poly (1,2-diaminobenzene) flim
    • Yao T., Takashima K. Amperometric biosensor with a composite memberane of sol-gel derived enzyme film and electrochemically generated poly (1,2-diaminobenzene) flim. Biosens. Bioelectron. 13:1998;67-73.
    • (1998) Biosens. Bioelectron. , vol.13 , pp. 67-73
    • Yao, T.1    Takashima, K.2
  • 45
    • 0037099226 scopus 로고    scopus 로고
    • Preparation of porous titania sol-gel matrix for immobilization of horseradish peroxidase by a vapor deposition method
    • Yu J., Ju H. Preparation of porous titania sol-gel matrix for immobilization of horseradish peroxidase by a vapor deposition method. Anal. Chem. 74:2002;3579-3583.
    • (2002) Anal. Chem. , vol.74 , pp. 3579-3583
    • Yu, J.1    Ju, H.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.