메뉴 건너뛰기




Volumn 1, Issue 9, 2006, Pages 988-997

The potential of differential mobility analysis coupled to MS for the study of very large singly and multiply charged proteins and protein complexes in the gas phase

Author keywords

Differential mobility analysis; Electrospray mass spectrometry; Gas phase electrophoretic mobility molecular analyzer; Ion mobility spectrometry; Size analysis

Indexed keywords

DIFFERENTIAL MOBILITY ANALYSIS; ELECTROSPRAY MASS SPECTROMETRY; GASPHASE; ION MOBILITY SPECTROMETRY; SIZE ANALYSIS;

EID: 33847639076     PISSN: 18606768     EISSN: 18607314     Source Type: Journal    
DOI: 10.1002/biot.200600070     Document Type: Article
Times cited : (50)

References (36)
  • 1
    • 0024438708 scopus 로고
    • Electrospray ionization for mass spectrometry of large biomolecules
    • Fenn, J. B., Mann, M., Meng, C. K., Wong, S. F., Whitehouse, C. M., Electrospray ionization for mass spectrometry of large biomolecules. Science 1989, 246, 64-71.
    • (1989) Science , vol.246 , pp. 64-71
    • Fenn, J.B.1    Mann, M.2    Meng, C.K.3    Wong, S.F.4    Whitehouse, C.M.5
  • 2
    • 20444486424 scopus 로고    scopus 로고
    • Electrospray ionization mass spectrometry and ion mobility analysis of the 20S proteasome complex
    • Loo J. A., Berhane B., Kaddis C. S., Wooding, K. M. et al., Electrospray ionization mass spectrometry and ion mobility analysis of the 20S proteasome complex. J. Am. Soc. Mass Spectrom. 2005, 16, 998-1008.
    • (2005) J. Am. Soc. Mass Spectrom. , vol.16 , pp. 998-1008
    • Loo, J.A.1    Berhane, B.2    Kaddis, C.S.3    Wooding, K.M.4
  • 3
    • 0000753479 scopus 로고    scopus 로고
    • Measurement of noncovalent complexes with high m/z by electrospray time-of-flight mass spectrometry
    • Ens, W., Standing, K. G., and Chernushevich, I. V., Editors, Kluwer, Dordrecht
    • Chernushevich I. V., Ens, W., Standing, K. G., Measurement of noncovalent complexes with high m/z by electrospray time-of-flight mass spectrometry. In: Ens, W., Standing, K. G., and Chernushevich, I. V., Editors, New Methods for the Study of Biomolecular Complexes, Kluwer, Dordrecht 1998, pp. 101-116
    • (1998) New Methods for the Study of Biomolecular Complexes , pp. 101-116
    • Chernushevich, I.V.1    Ens, W.2    Standing, K.G.3
  • 4
    • 0034639980 scopus 로고    scopus 로고
    • Electrospray time-of-flight mass spectrometry of the intact Ms2 virus capsid
    • Tito, M. A., Tars, K., Valegard, K., Hajdu, J., Robinson, C. V., Electrospray time-of-flight mass spectrometry of the intact Ms2 virus capsid. J. Am. Chem. Soc. 2000, 122, 3550-3551.
    • (2000) J. Am. Chem. Soc. , vol.122 , pp. 3550-3551
    • Tito, M.A.1    Tars, K.2    Valegard, K.3    Hajdu, J.4    Robinson, C.V.5
  • 5
    • 0032195850 scopus 로고    scopus 로고
    • Ion ion chemistry of high-mass multiply charged ions
    • McLuckey, S. A., Stephenson, J. L., Ion ion chemistry of high-mass multiply charged ions. Mass Spectrom. Rev. 1998, 17, 369-407.
    • (1998) Mass Spectrom. Rev. , vol.17 , pp. 369-407
    • McLuckey, S.A.1    Stephenson, J.L.2
  • 6
    • 26944438195 scopus 로고    scopus 로고
    • Recent developments in the ion/ion chemistry of high-mass multiply charged ions
    • Pitteri, S. J., McLuckey, S. A., Recent developments in the ion/ion chemistry of high-mass multiply charged ions. Mass Spectrom. Rev. 2005, 24, 931-958.
    • (2005) Mass Spectrom. Rev. , vol.24 , pp. 931-958
    • Pitteri, S.J.1    McLuckey, S.A.2
  • 8
    • 0030167866 scopus 로고    scopus 로고
    • Macromolecule determination based on electrophoretic mobility in air globular proteins
    • Kaufman, S. L., Skogen, J. W., Dorman, F. D., Zarrin, F., Lewis, K. C., Macromolecule determination based on electrophoretic mobility in air globular proteins. Anal. Chem. 1996, 68, 1895-1904.
    • (1996) Anal. Chem. , vol.68 , pp. 1895-1904
    • Kaufman, S.L.1    Skogen, J.W.2    Dorman, F.D.3    Zarrin, F.4    Lewis, K.C.5
  • 9
    • 0037213116 scopus 로고    scopus 로고
    • Performance of a quadrupole ion trap mass spectrometer adapted for ion/ion reaction studies
    • Reid G. E., Wells, J. M., Badman, E. R., McLuckey, S. A., Performance of a quadrupole ion trap mass spectrometer adapted for ion/ion reaction studies. Int. J. Mass Spectrom. 2003, 222, 243-258.
    • (2003) Int. J. Mass Spectrom. , vol.222 , pp. 243-258
    • Reid, G.E.1    Wells, J.M.2    Badman, E.R.3    McLuckey, S.A.4
  • 10
    • 49549137435 scopus 로고
    • Aerosol classification by electric mobility: Apparatus, theory and applications
    • Knutson, K. O., Whitby, K. T., Aerosol classification by electric mobility: Apparatus, theory and applications. J. Aerosol Sci. 1975, 6, 443-451.
    • (1975) J. Aerosol Sci. , vol.6 , pp. 443-451
    • Knutson, K.O.1    Whitby, K.T.2
  • 11
    • 4644359803 scopus 로고    scopus 로고
    • Charge-induced unfolding of multiply charged polyethylene glycol ions
    • Ude, S., Fernandez de la Mora, J., Thomson, B. A., Charge-induced unfolding of multiply charged polyethylene glycol ions. J. Am. Chem. Soc. 2004, 126, 12184-12190.
    • (2004) J. Am. Chem. Soc. , vol.126 , pp. 12184-12190
    • Ude, S.1    Fernandez de la Mora, J.2    Thomson, B.A.3
  • 13
    • 0034784941 scopus 로고    scopus 로고
    • Charge-reduced nano electrospray ionization combined with differential mobility analysis of peptides, proteins, glycoproteins, noncovalent protein complexes and viruses
    • Bacher, G., Szymanski, W. W., Kaufman, S. L., Zollner, P. et al., Charge-reduced nano electrospray ionization combined with differential mobility analysis of peptides, proteins, glycoproteins, noncovalent protein complexes and viruses. J. Mass Spectrom. 2001, 36, 1038-1052.
    • (2001) J. Mass Spectrom. , vol.36 , pp. 1038-1052
    • Bacher, G.1    Szymanski, W.W.2    Kaufman, S.L.3    Zollner, P.4
  • 14
    • 32444446480 scopus 로고    scopus 로고
    • Charge reduced electrospray size spectrometry of mega- and gigadalton complexes whole viruses and virus fragments
    • Hogan, C. J., Kettleson, E. M., Ramaswami, B., Chen, D. R., Biswas, P., Charge reduced electrospray size spectrometry of mega- and gigadalton complexes whole viruses and virus fragments. Anal. Chem. 2006, 78, 844-852.
    • (2006) Anal. Chem. , vol.78 , pp. 844-852
    • Hogan, C.J.1    Kettleson, E.M.2    Ramaswami, B.3    Chen, D.R.4    Biswas, P.5
  • 15
    • 33646266030 scopus 로고    scopus 로고
    • Resolution improvements of a nano-DMA operating transonically
    • Martínez-Lozano, P., Fernández de la Mora, J., Resolution improvements of a nano-DMA operating transonically. J. Aerosol Sci. 2006, 37, 500-512.
    • (2006) J. Aerosol Sci. , vol.37 , pp. 500-512
    • Martínez-Lozano, P.1    Fernández de la Mora, J.2
  • 16
    • 0032101038 scopus 로고    scopus 로고
    • Design and evaluation of a nanometer aerosol differential mobility analyzer (nano-DMA)
    • Chen, D. R., Pui, D. Y. H., Hummes, D., Fissan, H. et al., Design and evaluation of a nanometer aerosol differential mobility analyzer (nano-DMA). J. Aerosol Sci. 1998, 29, 497-509.
    • (1998) J. Aerosol Sci. , vol.29 , pp. 497-509
    • Chen, D.R.1    Pui, D.Y.H.2    Hummes, D.3    Fissan, H.4
  • 18
    • 0033654137 scopus 로고    scopus 로고
    • Peptides and proteins in the vapor phase
    • Jarrold M. F., Peptides and proteins in the vapor phase. Annu. Rev. Phys. Chem. 2000, 51, 179-207.
    • (2000) Annu. Rev. Phys. Chem. , vol.51 , pp. 179-207
    • Jarrold, M.F.1
  • 19
    • 33646357505 scopus 로고    scopus 로고
    • Evidence for many resolvable structures within conformation types of electrosprayed ubiquitin ions
    • Koeniger, S. L., Merenbloom, S. I., Clemmer, D. E., Evidence for many resolvable structures within conformation types of electrosprayed ubiquitin ions. J. Phys. Chem. B 2006, 110, 7017-7021.
    • (2006) J. Phys. Chem. B , vol.110 , pp. 7017-7021
    • Koeniger, S.L.1    Merenbloom, S.I.2    Clemmer, D.E.3
  • 20
    • 33646801627 scopus 로고    scopus 로고
    • Characterizing the structures and folding of free proteins using 2-D gas-phase separations: Observation of multiple unfolded conformers
    • Shvartsburg, A. A., Li, F. M., Tang, K. Q., Smith, R. D., Characterizing the structures and folding of free proteins using 2-D gas-phase separations: Observation of multiple unfolded conformers. Anal. Chem. 2006, 78, 3304-3315.
    • (2006) Anal. Chem. , vol.78 , pp. 3304-3315
    • Shvartsburg, A.A.1    Li, F.M.2    Tang, K.Q.3    Smith, R.D.4
  • 21
    • 26944459246 scopus 로고    scopus 로고
    • Controlling gasphase reactions for efficient charge reduction electrospray mass spectrometry of intact proteins
    • Frey, B. L., Lin, Y., Westphall, M. S., Smith, L. M., Controlling gasphase reactions for efficient charge reduction electrospray mass spectrometry of intact proteins. J. Am. Soc. Mass Spectrom. 2005, 16, 1876-1887.
    • (2005) J. Am. Soc. Mass Spectrom. , vol.16 , pp. 1876-1887
    • Frey, B.L.1    Lin, Y.2    Westphall, M.S.3    Smith, L.M.4
  • 22
    • 0033984616 scopus 로고    scopus 로고
    • Electrospray diagnostics performed by using sucrose and proteins in the gas-phase electrophoretic mobility molecular analyzer (GEMMA)
    • Kaufman, S. L., Electrospray diagnostics performed by using sucrose and proteins in the gas-phase electrophoretic mobility molecular analyzer (GEMMA). Anal. Chim. Acta 2000, 406, 3-10.
    • (2000) Anal. Chim. Acta , vol.406 , pp. 3-10
    • Kaufman, S.L.1
  • 23
    • 1242271254 scopus 로고    scopus 로고
    • Fernandez de la Mora, J., Mass analysis of water-soluble polymers by mobility measurement of charge-reduced electrosprays
    • Saucy, D., Ude, S., Lenggoro, W., Fernandez de la Mora, J., Mass analysis of water-soluble polymers by mobility measurement of charge-reduced electrosprays. Anal. Chem. 2004, 76, 1045-1053.
    • (2004) Anal. Chem. , vol.76 , pp. 1045-1053
    • Saucy, D.1    Ude, S.2    Lenggoro, W.3
  • 24
    • 0842327203 scopus 로고    scopus 로고
    • Fernandez de la Mora, J., Saucy, D. A., Alexander, J. N., IV, Mass distribution measurement of water-insoluble polymers by charge-reduced electrospray mobility analysis
    • Ku, B-K., Fernandez de la Mora, J., Saucy, D. A., Alexander, J. N., IV, Mass distribution measurement of water-insoluble polymers by charge-reduced electrospray mobility analysis. Anal. Chem. 2004, 76, 814-822.
    • (2004) Anal. Chem. , vol.76 , pp. 814-822
    • Ku, B.-K.1
  • 25
    • 27744463781 scopus 로고    scopus 로고
    • Aerosol size standards in the nanometer size range: II. Narrow size distributions of polystyrene 3-11 nm in diameter
    • Ude, S., Fernandez de la Mora, J., Alexander, J. N., IV, Saucy, D. A., Aerosol size standards in the nanometer size range: II. Narrow size distributions of polystyrene 3-11 nm in diameter. J. Colloid Interface Sci. 2006, 293, 384-393.
    • (2006) J. Colloid Interface Sci. , vol.293 , pp. 384-393
    • Ude, S.1    Fernandez de la Mora, J.2    Alexander IV, J.N.3    Saucy, D.A.4
  • 27
    • 0002124332 scopus 로고    scopus 로고
    • Electrospray ionization of large multiply charged species proceeds via Dole's charged residue mechanism
    • Fernández de la Mora, J., Electrospray ionization of large multiply charged species proceeds via Dole's charged residue mechanism. Anal. Chim. Acta 2000, 406, 93-104.
    • (2000) Anal. Chim. Acta , vol.406 , pp. 93-104
    • Fernández de la Mora, J.1
  • 28
    • 0345062639 scopus 로고    scopus 로고
    • Structures of carbon cluster ions from 3 to 60 atoms: Linears to rings to fullerenes
    • Von Helden, G., Hsu M-T., Kemper, P. R., Bowers, M. T., Structures of carbon cluster ions from 3 to 60 atoms: Linears to rings to fullerenes. J. Chem. Phys. 1999, 95, 3835-3842.
    • (1999) J. Chem. Phys. , vol.95 , pp. 3835-3842
    • Von Helden, G.1    Hsu, M.-T.2    Kemper, P.R.3    Bowers, M.T.4
  • 31
    • 18844425931 scopus 로고    scopus 로고
    • High-sensitivity ion mobility spectrometry/mass spectrometry using electrodynamic ion funnel interfaces
    • Tang, K., Shvartsburg, A. A., Lee, H. N., Prior, D. C. et al., High-sensitivity ion mobility spectrometry/mass spectrometry using electrodynamic ion funnel interfaces. Anal. Chem. 2005, 77, 3330-3339.
    • (2005) Anal. Chem. , vol.77 , pp. 3330-3339
    • Tang, K.1    Shvartsburg, A.A.2    Lee, H.N.3    Prior, D.C.4
  • 32
    • 33646801627 scopus 로고    scopus 로고
    • Characterizing the structures and folding of free proteins using 2-D gas-phase separations: Observation of multiple unfolded conformers
    • Shvartsburg, A. A., Li, F. M., Tang, K. Q., Smith, R. D., Characterizing the structures and folding of free proteins using 2-D gas-phase separations: Observation of multiple unfolded conformers. Anal. Chem. 2006, 78, 3304-3315.
    • (2006) Anal. Chem. , vol.78 , pp. 3304-3315
    • Shvartsburg, A.A.1    Li, F.M.2    Tang, K.Q.3    Smith, R.D.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.