메뉴 건너뛰기




Volumn 34, Issue 3, 2007, Pages 206-212

Retention and leakage of implant-supported restorations luted with provisional cement: A pilot study

Author keywords

Cement; Compression; Implant; Marginal leakage; Tensile bond strength; Thermal cycling

Indexed keywords

EMOLLIENT AGENT; IMPROV; MINERAL OIL; PETROLATUM; RESIN CEMENT; TEMPBOND NE; TOOTH CEMENT; UNCLASSIFIED DRUG; ZINC OXIDE; ZINC OXIDE EUGENOL; ZINC PHOSPHATE;

EID: 33846939488     PISSN: 0305182X     EISSN: 13652842     Source Type: Journal    
DOI: 10.1111/j.1365-2842.2006.01673.x     Document Type: Article
Times cited : (18)

References (32)
  • 1
    • 0032061298 scopus 로고    scopus 로고
    • Cemented single crowns on osseointegrated implants after 5 years: Results from a prospective study in CeraOne
    • Andersson B, Odman P, Carlsson L, Branemark PI. Cemented single crowns on osseointegrated implants after 5 years: results from a prospective study in CeraOne. Int J Prothodont. 1998;11:212-218.
    • (1998) Int J Prothodont , vol.11 , pp. 212-218
    • Andersson, B.1    Odman, P.2    Carlsson, L.3    Branemark, P.I.4
  • 2
    • 0031088298 scopus 로고    scopus 로고
    • Multicenter retrospective analysis of the ITI implant system used for single-tooth replacements: Preliminary results at 6 or months of loading
    • Levine RA, Clem DS, Wilson TG Jr, Higginbottom F, Solnit G. Multicenter retrospective analysis of the ITI implant system used for single-tooth replacements: preliminary results at 6 or months of loading. Int J Oral Maxillofac Implants. 1997;12:237-242.
    • (1997) Int J Oral Maxillofac Implants , vol.12 , pp. 237-242
    • Levine, R.A.1    Clem, D.S.2    Wilson Jr, T.G.3    Higginbottom, F.4    Solnit, G.5
  • 5
    • 0030635617 scopus 로고    scopus 로고
    • Cement-retained versus screw-retained implant restorations: Achieving optimal occlusion and esthetics in implant dentistry
    • Hebel K, Gajjar R. Cement-retained versus screw-retained implant restorations: achieving optimal occlusion and esthetics in implant dentistry. J Prosthet Dent. 1997;77:28-35.
    • (1997) J Prosthet Dent , vol.77 , pp. 28-35
    • Hebel, K.1    Gajjar, R.2
  • 6
    • 0032160199 scopus 로고    scopus 로고
    • Dental luting agents: A review of the current literature
    • Rosensteil SF, Land MF, Crispin BJ. Dental luting agents: a review of the current literature. J Prosthet Dent. 1998;80:280-301.
    • (1998) J Prosthet Dent , vol.80 , pp. 280-301
    • Rosensteil, S.F.1    Land, M.F.2    Crispin, B.J.3
  • 7
    • 4444333437 scopus 로고    scopus 로고
    • Immediate provisional restoration of Osseotite implants: A clinical report of 18-month results
    • Drago CJ, Lazzara RJ. Immediate provisional restoration of Osseotite implants: a clinical report of 18-month results. Int J Oral Maxillofac Implants. 2004;19:534-541.
    • (2004) Int J Oral Maxillofac Implants , vol.19 , pp. 534-541
    • Drago, C.J.1    Lazzara, R.J.2
  • 8
    • 0030144094 scopus 로고    scopus 로고
    • The use of provisional restoration in implant dentistry: A clinical report
    • Moscovitch MS, Saba S. The use of provisional restoration in implant dentistry: a clinical report. Int J Oral Maxillofac Implants. 1996;11:395-399.
    • (1996) Int J Oral Maxillofac Implants , vol.11 , pp. 395-399
    • Moscovitch, M.S.1    Saba, S.2
  • 9
    • 0027613649 scopus 로고
    • Adhesive cements and cementation
    • White SN. Adhesive cements and cementation. J Calif Dent Assoc. 1993;21:30-37.
    • (1993) J Calif Dent Assoc , vol.21 , pp. 30-37
    • White, S.N.1
  • 11
    • 7244232613 scopus 로고    scopus 로고
    • Effect of preparation convergence on retention and seating discrepancy of complete veneer crowns
    • Chan DCN, Wilson AH Jr, Barbe P, Cronin RJ Jr, Chung C. Effect of preparation convergence on retention and seating discrepancy of complete veneer crowns. J Oral Rehabil. 2004;31:1007-1013.
    • (2004) J Oral Rehabil , vol.31 , pp. 1007-1013
    • Chan, D.C.N.1    Wilson Jr, A.H.2    Barbe, P.3    Cronin Jr, R.J.4    Chung, C.5
  • 12
    • 33745491003 scopus 로고    scopus 로고
    • Implant supported fixed prostheses
    • Rosensteil SF, Land MF, Fujimoto J, eds, 3rd edn. St Louis: Mosby;
    • McGlumphy EA. Implant supported fixed prostheses. In: Rosensteil SF, Land MF, Fujimoto J, eds. Contemporary Fixed Prosthodontics. 3rd edn. St Louis: Mosby; 2001:313-353.
    • (2001) Contemporary Fixed Prosthodontics , pp. 313-353
    • McGlumphy, E.A.1
  • 13
    • 0024688842 scopus 로고
    • Microleakage of core materials for complete cast gold crowns
    • Tjan AH, Chiu J. Microleakage of core materials for complete cast gold crowns. J Prosthet Dent. 1989;61:659-664.
    • (1989) J Prosthet Dent , vol.61 , pp. 659-664
    • Tjan, A.H.1    Chiu, J.2
  • 14
    • 0032132650 scopus 로고    scopus 로고
    • Peri-implant microflora of implants with cemented and screw retained suprastructures
    • Keller W, Brägger U, Mombelli A. Peri-implant microflora of implants with cemented and screw retained suprastructures. Clin Oral Implants Res. 1998;9:209-217.
    • (1998) Clin Oral Implants Res , vol.9 , pp. 209-217
    • Keller, W.1    Brägger, U.2    Mombelli, A.3
  • 15
    • 16344389173 scopus 로고    scopus 로고
    • Microleakage of various cementing agents for full cast crowns
    • Piwowarczyk A, Lauer HC, Sorensen JA. Microleakage of various cementing agents for full cast crowns. Dent Mater. 2005;21:445-453.
    • (2005) Dent Mater , vol.21 , pp. 445-453
    • Piwowarczyk, A.1    Lauer, H.C.2    Sorensen, J.A.3
  • 16
    • 0035287492 scopus 로고    scopus 로고
    • In vitro microleakage of luting cements and crown foundation material
    • Lindquist TJ, Connolly J. In vitro microleakage of luting cements and crown foundation material. J Prosthet Dent. 2001;85:292-298.
    • (2001) J Prosthet Dent , vol.85 , pp. 292-298
    • Lindquist, T.J.1    Connolly, J.2
  • 17
    • 0029179850 scopus 로고
    • Microleakage through dentin after crown cementation
    • White SN, Furuichi R, Kyomen SM. Microleakage through dentin after crown cementation. J Endod. 1995;21:9-12.
    • (1995) J Endod , vol.21 , pp. 9-12
    • White, S.N.1    Furuichi, R.2    Kyomen, S.M.3
  • 18
    • 0029171517 scopus 로고
    • Thermocycling and dwell times in microleakage evaluation for bonded restorations
    • Rossomando KJ, Wendt SL Jr. Thermocycling and dwell times in microleakage evaluation for bonded restorations. Dent Mater. 1995;11:47-51.
    • (1995) Dent Mater , vol.11 , pp. 47-51
    • Rossomando, K.J.1    Wendt Jr, S.L.2
  • 19
    • 0028370295 scopus 로고
    • Effects of thermocycling, load-cycling, and blood contamination on cemented implant abutments
    • GaRey DJ, Tjan AH, James RA, Caputo AA. Effects of thermocycling, load-cycling, and blood contamination on cemented implant abutments. J Prosthet Dent. 1994;71:124-132.
    • (1994) J Prosthet Dent , vol.71 , pp. 124-132
    • GaRey, D.J.1    Tjan, A.H.2    James, R.A.3    Caputo, A.A.4
  • 21
    • 4444297012 scopus 로고    scopus 로고
    • In vitro shear bond strength of cementing agents to fixed prosthodontic restorative agents
    • Piwowarczyk A, Lauer HC, Sorensen JA. In vitro shear bond strength of cementing agents to fixed prosthodontic restorative agents. J Prosthet Dent. 2004;92:265-273.
    • (2004) J Prosthet Dent , vol.92 , pp. 265-273
    • Piwowarczyk, A.1    Lauer, H.C.2    Sorensen, J.A.3
  • 22
    • 0141959776 scopus 로고    scopus 로고
    • Effect of simulated resin-bonded fixed partial denture clinical conditions on resin cement mechanical properties
    • Walker MP, Spencer P, Eick JD. Effect of simulated resin-bonded fixed partial denture clinical conditions on resin cement mechanical properties. J Oral Rehabil. 2003;30:837-846.
    • (2003) J Oral Rehabil , vol.30 , pp. 837-846
    • Walker, M.P.1    Spencer, P.2    Eick, J.D.3
  • 23
    • 0026178204 scopus 로고
    • The effect of connector design on cement retention in an implant and natural tooth-supported fixed partial denture
    • Mathews MF, Breeding LC, Dixon DL, Aquilino S. The effect of connector design on cement retention in an implant and natural tooth-supported fixed partial denture. J Prosthet Dent. 1991;65:822-827.
    • (1991) J Prosthet Dent , vol.65 , pp. 822-827
    • Mathews, M.F.1    Breeding, L.C.2    Dixon, D.L.3    Aquilino, S.4
  • 24
    • 0642311345 scopus 로고    scopus 로고
    • The effects of abutment taper, length, and cement type on resistance to dislodgement of cement-retained, implant-supported restorations
    • Bernal G, Okamura M, Munoz CA. The effects of abutment taper, length, and cement type on resistance to dislodgement of cement-retained, implant-supported restorations. J Prosthodont. 2003;12:111-115.
    • (2003) J Prosthodont , vol.12 , pp. 111-115
    • Bernal, G.1    Okamura, M.2    Munoz, C.A.3
  • 25
    • 0036689755 scopus 로고    scopus 로고
    • Comparative evaluation of casting retention using the ITI solid abutment with six cements
    • Mansour A, Ercoli C, Grase G, Tallents R, Moss M. Comparative evaluation of casting retention using the ITI solid abutment with six cements. Clin Oral Implants Res. 2002;13:343-348.
    • (2002) Clin Oral Implants Res , vol.13 , pp. 343-348
    • Mansour, A.1    Ercoli, C.2    Grase, G.3    Tallents, R.4    Moss, M.5
  • 27
    • 9144261667 scopus 로고    scopus 로고
    • Comparison of the tensile bond strength of cast metal crowns luted with resin cements
    • Fonseca RG, Dos Santos Cruz CA, Adabo GL, Vaz LG. Comparison of the tensile bond strength of cast metal crowns luted with resin cements. J Oral Rehabil. 2004;31:1080-1084.
    • (2004) J Oral Rehabil , vol.31 , pp. 1080-1084
    • Fonseca, R.G.1    Dos Santos Cruz, C.A.2    Adabo, G.L.3    Vaz, L.G.4
  • 28
    • 0032184747 scopus 로고    scopus 로고
    • Comparative study of the marginal microleakage of six cements in fixed provisional crowns
    • Baldissara P, Comin G, Martone F, Scotti R. Comparative study of the marginal microleakage of six cements in fixed provisional crowns. J Prosthet Dent. 1998;80:417-422.
    • (1998) J Prosthet Dent , vol.80 , pp. 417-422
    • Baldissara, P.1    Comin, G.2    Martone, F.3    Scotti, R.4
  • 29
    • 0027015469 scopus 로고
    • Use of luting agents with an implant system: Part II
    • Dixon D, Breeding L, Lily K. Use of luting agents with an implant system: part II. J Prosthet Dent. 1992;68:885-890.
    • (1992) J Prosthet Dent , vol.68 , pp. 885-890
    • Dixon, D.1    Breeding, L.2    Lily, K.3
  • 30
    • 0018027449 scopus 로고
    • The influence of surface roughness on the retentive ability of two dental luting cements
    • Oilo G, Jorgenson KD. The influence of surface roughness on the retentive ability of two dental luting cements. J Oral Rehabil. 1978;5:377-389.
    • (1978) J Oral Rehabil , vol.5 , pp. 377-389
    • Oilo, G.1    Jorgenson, K.D.2
  • 31
    • 0033192816 scopus 로고    scopus 로고
    • An in vitro wear device for determining posterior composite wear
    • Leinfelder KF, Suzuki S. An in vitro wear device for determining posterior composite wear. J Am Dent Assoc. 1999;130:1347-1353.
    • (1999) J Am Dent Assoc , vol.130 , pp. 1347-1353
    • Leinfelder, K.F.1    Suzuki, S.2
  • 32
    • 0024041402 scopus 로고
    • Effect of variation in powder-to liquid ratio of zinc phosphate cement on the retention of posts
    • Wacker DR, Tjan AHL. Effect of variation in powder-to liquid ratio of zinc phosphate cement on the retention of posts. J Prosthet Dent. 1988;60:49-52.
    • (1988) J Prosthet Dent , vol.60 , pp. 49-52
    • Wacker, D.R.1    Tjan, A.H.L.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.