메뉴 건너뛰기




Volumn 22, Issue 2, 2007, Pages 251-257

Polyethylene Wear Against Alumina and Zirconia Heads in Cemented Total Hip Arthroplasty

Author keywords

alumina; clinical result; polyethylene wear; total hip arthroplasty; zirconia

Indexed keywords

ALUMINUM OXIDE; BONE CEMENT; POLYETHYLENE; ZIRCONIUM OXIDE;

EID: 33846519914     PISSN: 08835403     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.arth.2006.03.004     Document Type: Article
Times cited : (31)

References (25)
  • 1
    • 0032775639 scopus 로고    scopus 로고
    • Advances in the processing, sterilization and crosslinking of ultra-high molecular weight polyethylene for total joint arthroplasty
    • Kurtz S.M., Muratoglu O.K., Evans M., et al. Advances in the processing, sterilization and crosslinking of ultra-high molecular weight polyethylene for total joint arthroplasty. Biomaterials 20 (1999) 1659
    • (1999) Biomaterials , vol.20 , pp. 1659
    • Kurtz, S.M.1    Muratoglu, O.K.2    Evans, M.3
  • 2
    • 0015319816 scopus 로고
    • Arthroplastie totale de la hanche par prosthese en alumine frittee
    • Boutin P. Arthroplastie totale de la hanche par prosthese en alumine frittee. Rev Chir Orthop 58 (1972) 229
    • (1972) Rev Chir Orthop , vol.58 , pp. 229
    • Boutin, P.1
  • 4
    • 0033771089 scopus 로고    scopus 로고
    • Zirconia as a sliding material
    • Cales B. Zirconia as a sliding material. Clin Orthop 379 (2000) 94
    • (2000) Clin Orthop , vol.379 , pp. 94
    • Cales, B.1
  • 5
    • 0032917811 scopus 로고    scopus 로고
    • Zirconia as a ceramic biomaterial
    • Piconi C., and Maccauro G. Zirconia as a ceramic biomaterial. Biomaterials 20 (1999) 1
    • (1999) Biomaterials , vol.20 , pp. 1
    • Piconi, C.1    Maccauro, G.2
  • 6
    • 0025834740 scopus 로고
    • Low wear rate of UHMWPE against zirconia ceramic (Y-PSZ) in comparison to alumina ceramic and SUS 316L alloy
    • Kumar P., Oka M., Ikeuchi K., et al. Low wear rate of UHMWPE against zirconia ceramic (Y-PSZ) in comparison to alumina ceramic and SUS 316L alloy. J Biomed Mater Res 25 (1991) 813
    • (1991) J Biomed Mater Res , vol.25 , pp. 813
    • Kumar, P.1    Oka, M.2    Ikeuchi, K.3
  • 8
    • 0034803312 scopus 로고    scopus 로고
    • Phase transformation of a zirconia ceramic head after total hip arthroplasty
    • Haraguchi K., Sugano N., Nishii T., et al. Phase transformation of a zirconia ceramic head after total hip arthroplasty. J Bone Joint Surg Br 83 (2001) 996
    • (2001) J Bone Joint Surg Br , vol.83 , pp. 996
    • Haraguchi, K.1    Sugano, N.2    Nishii, T.3
  • 9
    • 0034926714 scopus 로고    scopus 로고
    • A comparison of polyethylene wear in hips with cobalt-chrome or zirconia heads
    • Kim Y.H., Kim J.S., and Cho S.H. A comparison of polyethylene wear in hips with cobalt-chrome or zirconia heads. J Bone Joint Surg Br 83 (2001) 742
    • (2001) J Bone Joint Surg Br , vol.83 , pp. 742
    • Kim, Y.H.1    Kim, J.S.2    Cho, S.H.3
  • 10
    • 0037397639 scopus 로고    scopus 로고
    • Wear of enhanced ultra-high molecular-weight polyethylene (Hylamer) in combination with a 22.225 mm diameter zirconia femoral head
    • Wroblewski B.M., Siney P.D., and Fleming P.A. Wear of enhanced ultra-high molecular-weight polyethylene (Hylamer) in combination with a 22.225 mm diameter zirconia femoral head. J Bone Joint Surg Br 85 (2003) 376
    • (2003) J Bone Joint Surg Br , vol.85 , pp. 376
    • Wroblewski, B.M.1    Siney, P.D.2    Fleming, P.A.3
  • 11
    • 0038441585 scopus 로고    scopus 로고
    • Zirconia and alumina ceramics in comparison with stainless-steel heads. Polyethylene wear after a minimum ten-year follow-up
    • Hernigou P., and Bahrami T. Zirconia and alumina ceramics in comparison with stainless-steel heads. Polyethylene wear after a minimum ten-year follow-up. J Bone Joint Surg Br 85 (2003) 504
    • (2003) J Bone Joint Surg Br , vol.85 , pp. 504
    • Hernigou, P.1    Bahrami, T.2
  • 12
    • 0019957225 scopus 로고
    • Femoral component loosening using contemporary techniques of femoral cement fixation
    • Harris W.H., McCarthy J.C., and O'Neill D.A. Femoral component loosening using contemporary techniques of femoral cement fixation. J Bone Joint Surg Am 64 (1982) 1063
    • (1982) J Bone Joint Surg Am , vol.64 , pp. 1063
    • Harris, W.H.1    McCarthy, J.C.2    O'Neill, D.A.3
  • 14
    • 0043172244 scopus 로고    scopus 로고
    • Effect of alumina femoral heads on polyethylene wear in cemented total hip arthroplasty. Old versus current alumina
    • Tanaka K., Tamura J., Kawanabe K., et al. Effect of alumina femoral heads on polyethylene wear in cemented total hip arthroplasty. Old versus current alumina. J Bone Joint Surg Br 85 (2003) 655
    • (2003) J Bone Joint Surg Br , vol.85 , pp. 655
    • Tanaka, K.1    Tamura, J.2    Kawanabe, K.3
  • 15
    • 0030746652 scopus 로고    scopus 로고
    • Radiographic evaluation of penetration by the femoral head into the polyethylene liner over time
    • Sychterz C.J., Engh Jr. C.A., Shah N., et al. Radiographic evaluation of penetration by the femoral head into the polyethylene liner over time. J Bone Joint Surg Am 79 (1997) 1040
    • (1997) J Bone Joint Surg Am , vol.79 , pp. 1040
    • Sychterz, C.J.1    Engh Jr., C.A.2    Shah, N.3
  • 16
    • 0025343488 scopus 로고
    • Effect of femoral head size on wear in wear of the polyethylene acetabular component
    • Livermore J., Ilstrup L., and Morry B. Effect of femoral head size on wear in wear of the polyethylene acetabular component. J Bone Joint Surg Am 72 (1990) 518
    • (1990) J Bone Joint Surg Am , vol.72 , pp. 518
    • Livermore, J.1    Ilstrup, L.2    Morry, B.3
  • 17
    • 0033958767 scopus 로고    scopus 로고
    • Effect of low friction ion treated femoral heads on polyethylene wear rates
    • Maruyama M., Capello W.N., D'Antonio J.A., et al. Effect of low friction ion treated femoral heads on polyethylene wear rates. Clin Orthop 370 (2000) 183
    • (2000) Clin Orthop , vol.370 , pp. 183
    • Maruyama, M.1    Capello, W.N.2    D'Antonio, J.A.3
  • 18
    • 0012962157 scopus 로고
    • Polyethylene wear in total hip arthroplasty: volumetric wear measurement of retrieved acetabular components
    • Hashimoto Y., Bauer T.W., Jiang M., et al. Polyethylene wear in total hip arthroplasty: volumetric wear measurement of retrieved acetabular components. Trans Orthop Res Soc 20 (1995) 116
    • (1995) Trans Orthop Res Soc , vol.20 , pp. 116
    • Hashimoto, Y.1    Bauer, T.W.2    Jiang, M.3
  • 19
    • 0142057174 scopus 로고    scopus 로고
    • Surface crystalline phases and nanoindentation hardness of explanted zirconia femoral heads
    • Catledge S.A., Cook M., and Vohra Y.K. Surface crystalline phases and nanoindentation hardness of explanted zirconia femoral heads. J Mater Sci Mater Med 14 (2003) 863
    • (2003) J Mater Sci Mater Med , vol.14 , pp. 863
    • Catledge, S.A.1    Cook, M.2    Vohra, Y.K.3
  • 20
    • 0000708783 scopus 로고
    • Low wear rate of UHMWPE against zirconia ceramic (Y-PSZ)
    • Oka M., Kumar P., Ikeuchi K., et al. Low wear rate of UHMWPE against zirconia ceramic (Y-PSZ). Bioceramics 5 (1992) 373
    • (1992) Bioceramics , vol.5 , pp. 373
    • Oka, M.1    Kumar, P.2    Ikeuchi, K.3
  • 22
    • 10744222195 scopus 로고    scopus 로고
    • Current status of zirconia used in total hip implants
    • Clarke I.C., Manaka M., Green D.D., et al. Current status of zirconia used in total hip implants. J Bone Joint Surg Am 85 Supple 4 (2003) 73
    • (2003) J Bone Joint Surg Am , vol.85 , Issue.Supple 4 , pp. 73
    • Clarke, I.C.1    Manaka, M.2    Green, D.D.3
  • 23
    • 0030627862 scopus 로고    scopus 로고
    • Frictional heating of bearing materials tested in a hip joint wear simulator
    • Lu Z., and McKellop H. Frictional heating of bearing materials tested in a hip joint wear simulator. Proc Inst Mech Eng (H) 211 (1997) 101
    • (1997) Proc Inst Mech Eng (H) , vol.211 , pp. 101
    • Lu, Z.1    McKellop, H.2
  • 24
    • 0026115091 scopus 로고
    • Effect of alumina addition on the tetragonal-to-monoclinic phase transformation in zirconia-3 mol% yttria
    • Tsubakino H., and Nozato R. Effect of alumina addition on the tetragonal-to-monoclinic phase transformation in zirconia-3 mol% yttria. J Am Ceram Soc 74 (1991) 440
    • (1991) J Am Ceram Soc , vol.74 , pp. 440
    • Tsubakino, H.1    Nozato, R.2
  • 25
    • 17444450453 scopus 로고    scopus 로고
    • Clinical and laboratory wear studies of zirconia-on-UHMWPE combination in cementless THA
    • Nakamura T., Tanaka K., Tamura J., et al. Clinical and laboratory wear studies of zirconia-on-UHMWPE combination in cementless THA. Key Eng Mater 240-242 (2003) 832
    • (2003) Key Eng Mater , vol.240-242 , pp. 832
    • Nakamura, T.1    Tanaka, K.2    Tamura, J.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.