메뉴 건너뛰기




Volumn 3, Issue 6, 2006, Pages 769-776

Implants for total hip arthroplasty

Author keywords

Bearing surface; Cemented; Cementless; Hip arthroplasty; Hip replacement

Indexed keywords

BONE CEMENT; CHONDROITIN SULFATE; GLUCOSAMINE;

EID: 33845906348     PISSN: 17434440     EISSN: 17452422     Source Type: Journal    
DOI: 10.1586/17434440.3.6.769     Document Type: Review
Times cited : (13)

References (115)
  • 1
    • 23644432858 scopus 로고    scopus 로고
    • Revision of cemented hip arthroplasty using a hydroxyapatite-ceramic-coated femoral component
    • Raman R, Kamath RP, Parikh A, Angus PD. Revision of cemented hip arthroplasty using a hydroxyapatite-ceramic-coated femoral component. J. Bone Joint Surg. 87-B, 1061-1067 (2005).
    • (2005) J. Bone Joint Surg. , vol.87 B , pp. 1061-1067
    • Raman, R.1    Kamath, R.P.2    Parikh, A.3    Angus, P.D.4
  • 2
    • 9644254364 scopus 로고    scopus 로고
    • Is 'aseptic' loosening of the prosthetic cup after total hip replacement due to nonculturable bacterial pathogens in patients with low-grade infection?
    • Ince A, Rupp J, Frommelt L, Katzer A, Gille J, Lohr JF. Is 'aseptic' loosening of the prosthetic cup after total hip replacement due to nonculturable bacterial pathogens in patients with low-grade infection? Clin. Infect. Dis. 39(11), 1599-1603 (2004).
    • (2004) Clin. Infect. Dis. , vol.39 , Issue.11 , pp. 1599-1603
    • Ince, A.1    Rupp, J.2    Frommelt, L.3    Katzer, A.4    Gille, J.5    Lohr, J.F.6
  • 3
    • 16644381512 scopus 로고    scopus 로고
    • Indications, methods, and results of cemented, hybrid, and cement-free implantation of THR
    • Kruckhans AR, Dustmann HO. Indications, methods, and results of cemented, hybrid, and cement-free implantation of THR. Surg. Technol. Int. 12, 253-257 (2004).
    • (2004) Surg. Technol. Int. , vol.12 , pp. 253-257
    • Kruckhans, A.R.1    Dustmann, H.O.2
  • 4
    • 0030482427 scopus 로고    scopus 로고
    • Hybrid total hip replacement: Rationale and intermediate clinical results
    • Harris WH. Hybrid total hip replacement: rationale and intermediate clinical results. Clin. Orthop. Relat. Res. 333, 155-164 (1996).
    • (1996) Clin. Orthop. Relat. Res. , vol.333 , pp. 155-164
    • Harris, W.H.1
  • 5
    • 0035857983 scopus 로고    scopus 로고
    • Recent advances: Orthopaedics
    • Moran CG, Tourret LJ. Recent advances: orthopaedics. BMJ 322(7291), 902-905 (2001).
    • (2001) BMJ , vol.322 , Issue.7291 , pp. 902-905
    • Moran, C.G.1    Tourret, L.J.2
  • 6
    • 33845908900 scopus 로고    scopus 로고
    • Knee and hip joint replacements. Longer lasting prostheses
    • Fraser J. Knee and hip joint replacements. Longer lasting prostheses. Aust. Fam. Physician 11 (1109-11), 1114-1115 (2001).
    • (2001) Aust. Fam. Physician , vol.11 , Issue.1109-1111 , pp. 1114-1115
    • Fraser, J.1
  • 7
    • 33646193989 scopus 로고    scopus 로고
    • Hip, knee, and ankle kinematics of high range of motion activities of daily living
    • Hemmerich A, Brown H, Smith S, Marthandam SS, Wyss UP. Hip, knee, and ankle kinematics of high range of motion activities of daily living. J. Orthop. Res. 24(4), 770-781 (2006).
    • (2006) J. Orthop. Res. , vol.24 , Issue.4 , pp. 770-781
    • Hemmerich, A.1    Brown, H.2    Smith, S.3    Marthandam, S.S.4    Wyss, U.P.5
  • 8
    • 0014848095 scopus 로고
    • Hip motion measurements for selected activities of daily living
    • Johnston RC, Schmidt GL. Hip motion measurements for selected activities of daily living. Clin. Orthop. 72, 205-215 (1970).
    • (1970) Clin. Orthop. , vol.72 , pp. 205-215
    • Johnston, R.C.1    Schmidt, G.L.2
  • 9
    • 0027641060 scopus 로고
    • Hip joint loading during walking and running, measured in 2 patients
    • Bergmann G, Graichen F, Rohlmann A. Hip joint loading during walking and running, measured in 2 patients. J. Biomech. 26, 969-990 (1993).
    • (1993) J. Biomech. , vol.26 , pp. 969-990
    • Bergmann, G.1    Graichen, F.2    Rohlmann, A.3
  • 11
    • 0029294152 scopus 로고
    • Is staircase walking a risk for the fixation of hip implants?
    • Bergmann G, Graichen F, Rohlmann A. Is staircase walking a risk for the fixation of hip implants? J. Biomech. 28, 535-553 (1995).
    • (1995) J. Biomech. , vol.28 , pp. 535-553
    • Bergmann, G.1    Graichen, F.2    Rohlmann, A.3
  • 12
    • 0034986916 scopus 로고    scopus 로고
    • Musculo-skeletal loading conditions at the hip during walking and stair climbing
    • Heller MO, Bergmann G, Deuretzbacher G et al. Musculo-skeletal loading conditions at the hip during walking and stair climbing. J. Biomech. 34, 883-893 (2001).
    • (2001) J. Biomech. , vol.34 , pp. 883-893
    • Heller, M.O.1    Bergmann, G.2    Deuretzbacher, G.3
  • 13
    • 20444365875 scopus 로고    scopus 로고
    • Reconstructed hip joint position and abductor muscle strength after total hip arthroplasty
    • Asayama I, Chamnongkich S, Simpson KJ, Kinsey TL, Mahoney OM. Reconstructed hip joint position and abductor muscle strength after total hip arthroplasty. J. Arthroplasty 20, 414-420 (2005).
    • (2005) J. Arthroplasty , vol.20 , pp. 414-420
    • Asayama, I.1    Chamnongkich, S.2    Simpson, K.J.3    Kinsey, T.L.4    Mahoney, O.M.5
  • 14
    • 21644470848 scopus 로고    scopus 로고
    • Total hip arthroplasty: The relationship between posterolateral reconstruction, abductor muscle strength, and femoral offset
    • Yamaguchi T, Naito M, Asayama I, Ishiko T. Total hip arthroplasty: the relationship between posterolateral reconstruction, abductor muscle strength, and femoral offset. J. Orthop. Surg. 12, 164-167 (2004).
    • (2004) J. Orthop. Surg. , vol.12 , pp. 164-167
    • Yamaguchi, T.1    Naito, M.2    Asayama, I.3    Ishiko, T.4
  • 15
    • 0028805203 scopus 로고
    • Effect of femoral offset on range of motion and abductor muscle strength after total hip arthroplasty
    • McGrory BJ, Morrey BF, Cahalan TD, An KN, Cabanela ME. Effect of femoral offset on range of motion and abductor muscle strength after total hip arthroplasty. J. Bone Joint Surg. 77-B, 865-869 (1995).
    • (1995) J. Bone Joint Surg. , vol.77 B , pp. 865-869
    • McGrory, B.J.1    Morrey, B.F.2    Cahalan, T.D.3    An, K.N.4    Cabanela, M.E.5
  • 16
    • 0036713568 scopus 로고    scopus 로고
    • Relationship between radiographic measurements of reconstructed hip joint position and the Trendelenburg sign
    • Asayama I, Naito M, Fujisawa M, Kambe T. Relationship between radiographic measurements of reconstructed hip joint position and the Trendelenburg sign. J. Arthroplasty 17, 747-51 (2002).
    • (2002) J. Arthroplasty , vol.17 , pp. 747-751
    • Asayama, I.1    Naito, M.2    Fujisawa, M.3    Kambe, T.4
  • 17
    • 0031743864 scopus 로고    scopus 로고
    • The effectiveness of exercise therapy in patients with osteoarthritis of the hip or knee: A randomized clinical trial
    • van Baar ME, Dekker J, Oostendorp RA et al. The effectiveness of exercise therapy in patients with osteoarthritis of the hip or knee: a randomized clinical trial. J. Rheum. 25, 2432-2439 (1998).
    • (1998) J. Rheum. , vol.25 , pp. 2432-2439
    • van Baar, M.E.1    Dekker, J.2    Oostendorp, R.A.3
  • 18
    • 33645061272 scopus 로고    scopus 로고
    • Efficacy and tolerance of an oral enzyme combination in painful osteoarthritis of the hip. A double-blind, randomized study comparing oral enzymes with non-steroidal anti-inflammatory drugs
    • Klein G, Kullich W, Schnitker J, Schwann H. Efficacy and tolerance of an oral enzyme combination in painful osteoarthritis of the hip. A double-blind, randomized study comparing oral enzymes with non-steroidal anti-inflammatory drugs. Clin. Exp. Rheumatol. 24, 25-30 (2006).
    • (2006) Clin. Exp. Rheumatol. , vol.24 , pp. 25-30
    • Klein, G.1    Kullich, W.2    Schnitker, J.3    Schwann, H.4
  • 19
    • 16344383840 scopus 로고    scopus 로고
    • Evaluation of the comparative efficacy of etoricoxib and ibuprofen for treatment of patients with osteoarthritis: A randomized, double-blind, placebo-controlled trial
    • Wiesenhutter CW, Boice JA, Ko A et al. Evaluation of the comparative efficacy of etoricoxib and ibuprofen for treatment of patients with osteoarthritis: a randomized, double-blind, placebo-controlled trial. Mayo Clin. Proc. 80, 470-479 (2005).
    • (2005) Mayo Clin. Proc. , vol.80 , pp. 470-479
    • Wiesenhutter, C.W.1    Boice, J.A.2    Ko, A.3
  • 20
    • 32844455611 scopus 로고    scopus 로고
    • Celecoxib versus naproxen and diclofenac in osteoarthritis patients: SUCCESS-I study
    • Singh G, Fort JG, Goldstein JL et al. Celecoxib versus naproxen and diclofenac in osteoarthritis patients: SUCCESS-I study. Am. J. Med. 119, 255-266 (2006).
    • (2006) Am. J. Med. , vol.119 , pp. 255-266
    • Singh, G.1    Fort, J.G.2    Goldstein, J.L.3
  • 21
    • 20744457410 scopus 로고    scopus 로고
    • Drug insight: Cyclo-oxygenase 2 inhibitors and cardiovascular risk - Where are we now?
    • Spektor G, Fuster V. Drug insight: cyclo-oxygenase 2 inhibitors and cardiovascular risk - where are we now? Nat. Clin. Pract. Cardiovasc. Med. 2(6), 290-300 (2005).
    • (2005) Nat. Clin. Pract. Cardiovasc. Med. , vol.2 , Issue.6 , pp. 290-300
    • Spektor, G.1    Fuster, V.2
  • 22
    • 24144436942 scopus 로고    scopus 로고
    • Current concepts in the therapeutic management of osteoarthritis with glucosamine
    • Reginster JY, Bruyere O, Fraikin G, Henrotin Y. Current concepts in the therapeutic management of osteoarthritis with glucosamine. Bull. Hosp. Joint Diseases 63(1-2), 31-36 (2005).
    • (2005) Bull. Hosp. Joint Diseases , vol.63 , Issue.1-2 , pp. 31-36
    • Reginster, J.Y.1    Bruyere, O.2    Fraikin, G.3    Henrotin, Y.4
  • 24
    • 0025886244 scopus 로고
    • Total hip replacement with cemented, uncemented, and hybrid prostheses: A comparison of clinical and radiographic results at two to four years
    • Wixson RL, Stulberg SD, Mehlhoff M. Total hip replacement with cemented, uncemented, and hybrid prostheses: a comparison of clinical and radiographic results at two to four years. J. Bone Joint Surg. 73-A(2), 257-270 (1991).
    • (1991) J. Bone Joint Surg. , vol.73 A , Issue.2 , pp. 257-270
    • Wixson, R.L.1    Stulberg, S.D.2    Mehlhoff, M.3
  • 25
    • 5444220921 scopus 로고    scopus 로고
    • Titanium and cobalt-chrome cementless femoral stems of identical shape produce equal results
    • Kim YH. Titanium and cobalt-chrome cementless femoral stems of identical shape produce equal results. Clin. Orthop. Relat. Res. 427, 148-156 (2004).
    • (2004) Clin. Orthop. Relat. Res. , vol.427 , pp. 148-156
    • Kim, Y.H.1
  • 26
    • 5344264425 scopus 로고    scopus 로고
    • Thigh pain in primary total hip arthroplasty: The effects of elastic moduli
    • Lavernia C, D'Apuzzo M, Hernandez V, Lee D. Thigh pain in primary total hip arthroplasty: the effects of elastic moduli. J. Arthroplasty 19(7 Suppl. 2), 10-16 (2004).
    • (2004) J. Arthroplasty , vol.19 , Issue.7 SUPPL. 2 , pp. 10-16
    • Lavernia, C.1    D'Apuzzo, M.2    Hernandez, V.3    Lee, D.4
  • 27
    • 0019518012 scopus 로고
    • An analysis of collar function and the use of titanium in femoral prostheses
    • Crowninshield RD, Brand RA, Johnston RC, Pedersen DR. An analysis of collar function and the use of titanium in femoral prostheses. Clin. Orthop. 158, 270-277 (1981).
    • (1981) Clin. Orthop. , vol.158 , pp. 270-277
    • Crowninshield, R.D.1    Brand, R.A.2    Johnston, R.C.3    Pedersen, D.R.4
  • 28
    • 0029589240 scopus 로고
    • Normalized and proportionalized cemented femoral stem designs. A 10-year clinical study
    • Jaffe WL, Jarolem KL. Normalized and proportionalized cemented femoral stem designs. A 10-year clinical study. J. Arthroplasty 10(Suppl.), S39-S44 (1995).
    • (1995) J. Arthroplasty , vol.10 , Issue.SUPPL.
    • Jaffe, W.L.1    Jarolem, K.L.2
  • 30
    • 0027938815 scopus 로고
    • Micromotion of femoral stems in total hip arthroplasty. A randomized study of cemented, hydroxyapatite-coated, and porous-coated stems with roentgen stereophotogrammetric analysis
    • Karrholm J, Malchau H, Snorrason F, Herberts P. Micromotion of femoral stems in total hip arthroplasty. A randomized study of cemented, hydroxyapatite-coated, and porous-coated stems with roentgen stereophotogrammetric analysis. J. Bone Joint Surg. 76-A(11), 1692-705 (1994).
    • (1994) J. Bone Joint Surg. , vol.76 A , Issue.11 , pp. 1692-1705
    • Karrholm, J.1    Malchau, H.2    Snorrason, F.3    Herberts, P.4
  • 31
    • 0031762032 scopus 로고    scopus 로고
    • Effects of design changes on cemented tapered femoral stem fixation
    • Middleton RG, Howie DW, Casti K, Sharpe P. Effects of design changes on cemented tapered femoral stem fixation. Clin. Orthop. 355, 47-56 (1998).
    • (1998) Clin. Orthop. , vol.355 , pp. 47-56
    • Middleton, R.G.1    Howie, D.W.2    Casti, K.3    Sharpe, P.4
  • 32
    • 0031790427 scopus 로고    scopus 로고
    • Pressurization and centralization enhance the quality and reproducibility of cement mantles
    • Noble PC, Collier MB, Maltry JA, Kamaric E, Tullos HS. Pressurization and centralization enhance the quality and reproducibility of cement mantles. Clin. Orthop. 355, 77-89 (1998).
    • (1998) Clin. Orthop. , vol.355 , pp. 77-89
    • Noble, P.C.1    Collier, M.B.2    Maltry, J.A.3    Kamaric, E.4    Tullos, H.S.5
  • 33
    • 0020068498 scopus 로고
    • An axisymmetric model of acetabular components in total hip arthroplasty
    • Pedersen DR, Crowninshield RD, Brand RA, Johnston RC. An axisymmetric model of acetabular components in total hip arthroplasty. J. Biomech. 15(4), 305-315 (1982).
    • (1982) J. Biomech. , vol.15 , Issue.4 , pp. 305-315
    • Pedersen, D.R.1    Crowninshield, R.D.2    Brand, R.A.3    Johnston, R.C.4
  • 35
    • 0030705211 scopus 로고    scopus 로고
    • Fixation of the acetabular component: The case for cement
    • Ranawat CS, Peters LE, Umlas ME. Fixation of the acetabular component: the case for cement. Clin. Orthop. 344, 207-215 (1997).
    • (1997) Clin. Orthop. , vol.344 , pp. 207-215
    • Ranawat, C.S.1    Peters, L.E.2    Umlas, M.E.3
  • 36
    • 0023802174 scopus 로고
    • A fifteen-year follow-up study of one hundred Charnley low-friction arthroplasties
    • McCoy TH, Salvati EA, Ranawat CS, Wilson PD. A fifteen-year follow-up study of one hundred Charnley low-friction arthroplasties. Orthop. Clin. North Am. 19(3), 467-476 (1988).
    • (1988) Orthop. Clin. North Am. , vol.19 , Issue.3 , pp. 467-476
    • McCoy, T.H.1    Salvati, E.A.2    Ranawat, C.S.3    Wilson, P.D.4
  • 37
    • 0028284420 scopus 로고
    • Charnley low-friction arthroplasty of the hip. Twenty-year results with cement
    • Kavanagh BF, Wallrichs S, Dewitz M et al. Charnley low-friction arthroplasty of the hip. Twenty-year results with cement. J. Arthroplasty 9(3), 229-234 (1994).
    • (1994) J. Arthroplasty , vol.9 , Issue.3 , pp. 229-234
    • Kavanagh, B.F.1    Wallrichs, S.2    Dewitz, M.3
  • 38
    • 0027301351 scopus 로고
    • The outcome of Charnley total hip arthroplasty with cement after a minimum twenty-year follow-up. The results of one surgeon
    • Schulte KR, Callaghan JJ, Kelley SS, Johnston RC. The outcome of Charnley total hip arthroplasty with cement after a minimum twenty-year follow-up. The results of one surgeon. J. Bone Joint Surg. 75-A(7), 961-975 (1993).
    • (1993) J. Bone Joint Surg. , vol.75 A , Issue.7 , pp. 961-975
    • Schulte, K.R.1    Callaghan, J.J.2    Kelley, S.S.3    Johnston, R.C.4
  • 39
    • 0026527960 scopus 로고
    • Improved cementing techniques and femoral component loosening in young patients with hip arthroplasty. A 12-year radiographic review
    • Barrack RL, Mulroy RD, Harris WH. Improved cementing techniques and femoral component loosening in young patients with hip arthroplasty. A 12-year radiographic review. J. Bone Joint Surg. 74-B(3), 385-389 (1992).
    • (1992) J. Bone Joint Surg. , vol.74 B , Issue.3 , pp. 385-389
    • Barrack, R.L.1    Mulroy, R.D.2    Harris, W.H.3
  • 40
    • 0029557806 scopus 로고
    • Total hip arthroplasty with use of so-called second-generation cementing techniques. A fifteen-year-average follow-up study
    • Mulroy WF, Estok DM, Harris WH. Total hip arthroplasty with use of so-called second-generation cementing techniques. A fifteen-year-average follow-up study. J. Bone Joint Surg. 77-A(12), 1845-1852 (1995).
    • (1995) J. Bone Joint Surg. , vol.77 A , Issue.12 , pp. 1845-1852
    • Mulroy, W.F.1    Estok, D.M.2    Harris, W.H.3
  • 41
    • 0032413147 scopus 로고    scopus 로고
    • The Harris Design-2 total hip replacement fixed with so-called second-generation cementing techniques. A ten to fifteen-year follow-up
    • Bourne RB, Rorabeck CH, Skutek M, Mikkelsen S, Winemaker M, Robertson D. The Harris Design-2 total hip replacement fixed with so-called second-generation cementing techniques. A ten to fifteen-year follow-up. J. Bone Joint Surg. 80-A(12), 1775-1780 (1998).
    • (1998) J. Bone Joint Surg. , vol.80 A , Issue.12 , pp. 1775-1780
    • Bourne, R.B.1    Rorabeck, C.H.2    Skutek, M.3    Mikkelsen, S.4    Winemaker, M.5    Robertson, D.6
  • 42
    • 0028121998 scopus 로고
    • The femoral component in total hip arthroplasty: Six to eight-year follow-up of one hundred consecutive patients after use of a third-generation cementing technique
    • Oishi CS, Walker RH, Colwell CW. The femoral component in total hip arthroplasty: six to eight-year follow-up of one hundred consecutive patients after use of a third-generation cementing technique. J. Bone Joint Surg. 76-A(8), 1130-1136 (1994).
    • (1994) J. Bone Joint Surg. , vol.76 A , Issue.8 , pp. 1130-1136
    • Oishi, C.S.1    Walker, R.H.2    Colwell, C.W.3
  • 43
    • 0035217646 scopus 로고    scopus 로고
    • Minimal 10 year follow-up of a tapered cementless femoral component in total hip arthroplasty
    • Mallory TH, Lombardi AV, Leith JR et al. Minimal 10 year follow-up of a tapered cementless femoral component in total hip arthroplasty. J. Arthroplasty 16, 49-54 (2001).
    • (2001) J. Arthroplasty , vol.16 , pp. 49-54
    • Mallory, T.H.1    Lombardi, A.V.2    Leith, J.R.3
  • 44
    • 0037264552 scopus 로고    scopus 로고
    • Primary total hip arthroplasty with a second generation cementless total hip prosthesis in patients younger than fifty years of age
    • Kim YH, Oh SH, Kim JS. Primary total hip arthroplasty with a second generation cementless total hip prosthesis in patients younger than fifty years of age. J. Bone Joint Surg. 85-A, 109-114 (2003).
    • (2003) J. Bone Joint Surg. , vol.85 A , pp. 109-114
    • Kim, Y.H.1    Oh, S.H.2    Kim, J.S.3
  • 45
    • 0029842374 scopus 로고    scopus 로고
    • A tapered titanium femoral stem inserted without cement in a total hip arthroplasty: Radiographic evaluation and stability
    • Mulliken BD, Bourne RB, Rorabek CH, Nayak N. A tapered titanium femoral stem inserted without cement in a total hip arthroplasty: radiographic evaluation and stability J. Bone Joint Surg. 78-A, 1214-1225 (1996).
    • (1996) J. Bone Joint Surg. , vol.78 A , pp. 1214-1225
    • Mulliken, B.D.1    Bourne, R.B.2    Rorabek, C.H.3    Nayak, N.4
  • 46
    • 0029974592 scopus 로고    scopus 로고
    • Incidence of thigh pain after uncemented total hip arthroplasty as a function of femoral stem size
    • Vresilovic EJ, Hozack WJ, Rothman RH. Incidence of thigh pain after uncemented total hip arthroplasty as a function of femoral stem size. J. Arthroplasty 11, 304-311 (1996)
    • (1996) J. Arthroplasty , vol.11 , pp. 304-311
    • Vresilovic, E.J.1    Hozack, W.J.2    Rothman, R.H.3
  • 47
    • 0030471506 scopus 로고    scopus 로고
    • Total hip arthroplasty with hydroxyapatite-coated prostheses
    • Jaffe WL, Scott DF. Total hip arthroplasty with hydroxyapatite-coated prostheses. J. Bone Joint Surg. 78-A, 1918-1934 (1996).
    • (1996) J. Bone Joint Surg. , vol.78 A , pp. 1918-1934
    • Jaffe, W.L.1    Scott, D.F.2
  • 49
    • 0030696486 scopus 로고    scopus 로고
    • Proximally coated ingrowth prostheses: A review
    • Mont MA, Hungerford DS. Proximally coated ingrowth prostheses: a review. Clin. Orthop. 344, 139-149 (1997).
    • (1997) Clin. Orthop. , vol.344 , pp. 139-149
    • Mont, M.A.1    Hungerford, D.S.2
  • 50
    • 33644773527 scopus 로고    scopus 로고
    • The correlation between immediate radiolucent lines and early implant migration in cemented acetabular components
    • Kneif D, Downing MR, Ashcroft GP et al. The correlation between immediate radiolucent lines and early implant migration in cemented acetabular components. J. Arthroplasty 21(2), 215-220 (2006).
    • (2006) J. Arthroplasty , vol.21 , Issue.2 , pp. 215-220
    • Kneif, D.1    Downing, M.R.2    Ashcroft, G.P.3
  • 51
    • 0024270601 scopus 로고    scopus 로고
    • Long-term follow-up of cemented total hip replacement for osteoarthritis
    • Brick GW, Poss R. Long-term follow-up of cemented total hip replacement for osteoarthritis. Rheum. Dis. Clin. North Am. 14(3), 565-577 (1998).
    • (1998) Rheum. Dis. Clin. North Am. , vol.14 , Issue.3 , pp. 565-577
    • Brick, G.W.1    Poss, R.2
  • 52
    • 0023729268 scopus 로고
    • Radiographic performance of two different total hip cemented arthroplasties. A survivorship analysis
    • Sarmiento A, Natarajan V, Gruen TA, McMahon M. Radiographic performance of two different total hip cemented arthroplasties. A survivorship analysis. Orthop. Clin. North Am. 19(3), 505-515 (1988).
    • (1988) Orthop. Clin. North Am. , vol.19 , Issue.3 , pp. 505-515
    • Sarmiento, A.1    Natarajan, V.2    Gruen, T.A.3    McMahon, M.4
  • 53
    • 0032905061 scopus 로고    scopus 로고
    • The Harris-Galante porous-coated acetabular component with screw fixation: An average ten-year follow-up study
    • Clohisy JC, Harris WH. The Harris-Galante porous-coated acetabular component with screw fixation: an average ten-year follow-up study. J. Bone Joint Surg. 81-A, 66-73 (1999).
    • (1999) J. Bone Joint Surg. , vol.81 A , pp. 66-73
    • Clohisy, J.C.1    Harris, W.H.2
  • 54
    • 18944375927 scopus 로고    scopus 로고
    • Long-term results of the cementless porous-coatcd anatomic total hip prosthesis
    • Kim YH. Long-term results of the cementless porous-coatcd anatomic total hip prosthesis. J. Bone Joint Surg. 87-B(5), 623-627 (2005).
    • (2005) J. Bone Joint Surg. , vol.87 B , Issue.5 , pp. 623-627
    • Kim, Y.H.1
  • 55
    • 12344323398 scopus 로고    scopus 로고
    • Cementless porous-coated sockets without holes implanted with pure press-fit technique
    • Torga Spak R, Stuchin SA. Cementless porous-coated sockets without holes implanted with pure press-fit technique. J. Arthroplasty 20(1), 4-10 (2005).
    • (2005) J. Arthroplasty , vol.20 , Issue.1 , pp. 4-10
    • Torga Spak, R.1    Stuchin, S.A.2
  • 56
    • 4544290225 scopus 로고    scopus 로고
    • Clinical and radiographic results associated with a modern, cementless modular cup design in total hip arthroplasty
    • Valle AG, Zoppi A, Peterson MG, Salvati EA. Clinical and radiographic results associated with a modern, cementless modular cup design in total hip arthroplasty. J. Bone Joint Surg. 86-A(9), 1998-2004 (2004).
    • (2004) J. Bone Joint Surg. , vol.86 A , Issue.9 , pp. 1998-2004
    • Valle, A.G.1    Zoppi, A.2    Peterson, M.G.3    Salvati, E.A.4
  • 57
    • 0942301374 scopus 로고    scopus 로고
    • Cementless acetabular fixation at fifteen years. A comparison with the same surgeon's results following acetabular fixation with cement
    • Gaffey JL, Callaghan JJ, Pedersen DR, Goetz DD, Sullivan PM, Johnston RC. Cementless acetabular fixation at fifteen years. A comparison with the same surgeon's results following acetabular fixation with cement. J. Bone Joint Surg. 86-A(2), 257-261 (2004).
    • (2004) J. Bone Joint Surg. , vol.86 A , Issue.2 , pp. 257-261
    • Gaffey, J.L.1    Callaghan, J.J.2    Pedersen, D.R.3    Goetz, D.D.4    Sullivan, P.M.5    Johnston, R.C.6
  • 59
    • 4544222174 scopus 로고    scopus 로고
    • Thirty-day mortality following hip arthroplasty for acute fracture
    • Parvizi J, Ereth MH, Lewallen DG. Thirty-day mortality following hip arthroplasty for acute fracture. J. Bone Joint Surg. 86-A(9), 1983-1988 (2004).
    • (2004) J. Bone Joint Surg. , vol.86 A , Issue.9 , pp. 1983-1988
    • Parvizi, J.1    Ereth, M.H.2    Lewallen, D.G.3
  • 60
    • 1942487863 scopus 로고    scopus 로고
    • In-hospital deaths following elective total joint arthroplasty
    • Rauh MA, Krackow KA. In-hospital deaths following elective total joint arthroplasty. Orthopedics 27(4), 407-411 (2004).
    • (2004) Orthopedics , vol.27 , Issue.4 , pp. 407-411
    • Rauh, M.A.1    Krackow, K.A.2
  • 61
    • 1242319997 scopus 로고    scopus 로고
    • Primary total hip arthroplasty with an uncemented femoral component: A long term study of the taperloc stem
    • Parvizi J, Keisu KS, Hozack WJ, Sharkey PF, Rothman RH. Primary total hip arthroplasty with an uncemented femoral component: a long term study of the taperloc stem. J. Arthroplasty 19, 151-156 (2004).
    • (2004) J. Arthroplasty , vol.19 , pp. 151-156
    • Parvizi, J.1    Keisu, K.S.2    Hozack, W.J.3    Sharkey, P.F.4    Rothman, R.H.5
  • 62
    • 8144220495 scopus 로고    scopus 로고
    • Hydroxyapatite-coated prostheses in total hip and knee arthroplasty
    • Dumbleton J, Manley MT. Hydroxyapatite-coated prostheses in total hip and knee arthroplasty. J. Bone Joint Surg. 86-A. 2526-2540 (2004).
    • (2004) J. Bone Joint Surg. , vol.86 A , pp. 2526-2540
    • Dumbleton, J.1    Manley, M.T.2
  • 63
    • 0029974887 scopus 로고    scopus 로고
    • Comparative results of a distal modular sleeve, circumferential coating, and stiffness relief using the Anatomic Porous Replacement II
    • Dorr LD, Wan Z. Comparative results of a distal modular sleeve, circumferential coating, and stiffness relief using the Anatomic Porous Replacement II. J. Arthroplasty 11(4), 419-428 (1996).
    • (1996) J. Arthroplasty , vol.11 , Issue.4 , pp. 419-428
    • Dorr, L.D.1    Wan, Z.2
  • 64
    • 0029816260 scopus 로고    scopus 로고
    • Primary total hip arthroplasty with the Karl Zweymuller first-generation cementless prosthesis. A 5- to 9-year retrospective study
    • Delaunay CP, Kapandji AI. Primary total hip arthroplasty with the Karl Zweymuller first-generation cementless prosthesis. A 5- to 9-year retrospective study. J. Arthroplasty 11(6), 643-652 (1996).
    • (1996) J. Arthroplasty , vol.11 , Issue.6 , pp. 643-652
    • Delaunay, C.P.1    Kapandji, A.I.2
  • 65
    • 0030320795 scopus 로고    scopus 로고
    • Results of the cementless Mallory-Head primary total hip arthroplasty: A 5 to 7 year review
    • Mulliken BD, Bourne RB, Rorabeck CH, Nayak N. Results of the cementless Mallory-Head primary total hip arthroplasty: a 5 to 7 year review. Iowa Orthop. J. 16, 20-34 (1996).
    • (1996) Iowa Orthop. J. , vol.16 , pp. 20-34
    • Mulliken, B.D.1    Bourne, R.B.2    Rorabeck, C.H.3    Nayak, N.4
  • 66
    • 0030039643 scopus 로고    scopus 로고
    • Early radiographic results comparing cemented and cementless total hip arthroplasty
    • Mulliken BD, Nayak N, Bourne RB, Rorabeck CH, Bullas R. Early radiographic results comparing cemented and cementless total hip arthroplasty. J. Arthroplasty 11(1), 24-33 (1996).
    • (1996) J. Arthroplasty , vol.11 , Issue.1 , pp. 24-33
    • Mulliken, B.D.1    Nayak, N.2    Bourne, R.B.3    Rorabeck, C.H.4    Bullas, R.5
  • 67
    • 21544453313 scopus 로고    scopus 로고
    • Anterior thigh pain after cementless total hip arthroplasty
    • Faraj AA, Yousuf M. Anterior thigh pain after cementless total hip arthroplasty. Int. Orthop. 29(3), 149-151 (2005).
    • (2005) Int. Orthop. , vol.29 , Issue.3 , pp. 149-151
    • Faraj, A.A.1    Yousuf, M.2
  • 69
    • 0029842374 scopus 로고    scopus 로고
    • A tapered titanium femoral stem inserted without cement in a total hip arthroplasty. Radiographic evaluation and stability
    • Mulliken BD, Bourne RB, Rorabeck CH, Nayak N. A tapered titanium femoral stem inserted without cement in a total hip arthroplasty. Radiographic evaluation and stability. J. Bone Joint Surg. 78-A(8), 1214-1225 (1996).
    • (1996) J. Bone Joint Surg. , vol.78 A , Issue.8 , pp. 1214-1225
    • Mulliken, B.D.1    Bourne, R.B.2    Rorabeck, C.H.3    Nayak, N.4
  • 70
    • 0028054273 scopus 로고
    • Taperloc femoral component. A 2-6-year study of the first 100 consecutive cases
    • Hozack W, Gardiner R, Hearn S, Eng K, Rothman R. Taperloc femoral component. A 2-6-year study of the first 100 consecutive cases. J. Arthroplasty 9(5), 489-493 (1994).
    • (1994) J. Arthroplasty , vol.9 , Issue.5 , pp. 489-493
    • Hozack, W.1    Gardiner, R.2    Hearn, S.3    Eng, K.4    Rothman, R.5
  • 71
    • 0025449943 scopus 로고
    • Clinical and radiographic results with the Trilock femoral component - A wedge-fit porous ingrowth stem design
    • Hozack WJ, Booth B. Clinical and radiographic results with the Trilock femoral component - a wedge-fit porous ingrowth stem design. Semin. Arthroplasty 1(1), 64-69 (1990).
    • (1990) Semin. Arthroplasty , vol.1 , Issue.1 , pp. 64-69
    • Hozack, W.J.1    Booth, B.2
  • 73
    • 0032975280 scopus 로고    scopus 로고
    • Clinical and radiographic outcomes of total hip arthroplasty with insertion of an anatomically designed femoral component without cement for the treatment of primary osteoarthritis. A study with a minimum of six years of follow-up
    • 1999
    • Ragab AA, Kraay MJ, Goldberg VM. Clinical and radiographic outcomes of total hip arthroplasty with insertion of an anatomically designed femoral component without cement for the treatment of primary osteoarthritis. A study with a minimum of six years of follow-up. J. Bone Joint Surg. 1999, 81-A(2), 210-208 (1999).
    • (1999) J. Bone Joint Surg. , vol.81 A , Issue.2 , pp. 208-210
    • Ragab, A.A.1    Kraay, M.J.2    Goldberg, V.M.3
  • 74
    • 0033065994 scopus 로고    scopus 로고
    • Primary total hip arthroplasty with the AML total hip prosthesis
    • Kim YH, Kim JS, Cho SH. Primary total hip arthroplasty with the AML total hip prosthesis. Clin. Orthop. Relat. Res. 360, 147-158 (1999).
    • (1999) Clin. Orthop. Relat. Res. , vol.360 , pp. 147-158
    • Kim, Y.H.1    Kim, J.S.2    Cho, S.H.3
  • 75
    • 2642570359 scopus 로고    scopus 로고
    • Primary total hip arthroplasty with a proximally porous coated femoral stem
    • Sinha RK, Dungy DS, Yeon HB. Primary total hip arthroplasty with a proximally porous coated femoral stem. J. Bone Joint Surg. 86-A, 1254-1261 (2004).
    • (2004) J. Bone Joint Surg. , vol.86 A , pp. 1254-1261
    • Sinha, R.K.1    Dungy, D.S.2    Yeon, H.B.3
  • 77
    • 0030454624 scopus 로고    scopus 로고
    • Hybrid total hip arthroplasty: A 7 to eleven year follow-up
    • Goldberg VM, Ninomiya KG, Kraay M. Hybrid total hip arthroplasty: a 7 to eleven year follow-up. Clin. Orthop. 333, 147-154 (1996).
    • (1996) Clin. Orthop. , vol.333 , pp. 147-154
    • Goldberg, V.M.1    Ninomiya, K.G.2    Kraay, M.3
  • 78
    • 0141993628 scopus 로고    scopus 로고
    • Fifteen-year survivorship of a collarless, cemented normalized femoral stem in primary hybrid total hip arthroplasty with a modified third-generation cement technique
    • Rasquinha VJ, Dua V, Rodriguez JA, Ranawat CS. Fifteen-year survivorship of a collarless, cemented normalized femoral stem in primary hybrid total hip arthroplasty with a modified third-generation cement technique. J. Arthroplasty 18(7 Suppl. 1), 86-94 (2003).
    • (2003) J. Arthroplasty , vol.18 , Issue.7 SUPPL. 1 , pp. 86-94
    • Rasquinha, V.J.1    Dua, V.2    Rodriguez, J.A.3    Ranawat, C.S.4
  • 80
    • 33646825663 scopus 로고    scopus 로고
    • Treatment of the young active patient with osteoarthritis of the hip: A five- to seven-year comparison of hybrid total hip arthroplasty and metal-on-metal resurfacing
    • Pollard TC, Baker RP, Eastaugh-Waring SJ, Bannister GC. Treatment of the young active patient with osteoarthritis of the hip: a five- to seven-year comparison of hybrid total hip arthroplasty and metal-on-metal resurfacing. J. Bone Joint Surg. 88-B(5), 592-600 (2006).
    • (2006) J. Bone Joint Surg. , vol.88 B , Issue.5 , pp. 592-600
    • Pollard, T.C.1    Baker, R.P.2    Eastaugh-Waring, S.J.3    Bannister, G.C.4
  • 81
    • 22544453310 scopus 로고    scopus 로고
    • Alternative bearing surfaces in total hip arthroplasty
    • Tuli R, Parvizi J. Alternative bearing surfaces in total hip arthroplasty. Expert Rev. Med. Devices 2(4), 445-452 (2005).
    • (2005) Expert Rev. Med. Devices , vol.2 , Issue.4 , pp. 445-452
    • Tuli, R.1    Parvizi, J.2
  • 82
    • 0042235809 scopus 로고    scopus 로고
    • Alternative materials to improve total hip replacement tribology
    • Santavirta S, Bohler M, Harris WH et al. Alternative materials to improve total hip replacement tribology. Acta Orthop. Scand. 74(4), 380-388 (2003).
    • (2003) Acta Orthop. Scand. , vol.74 , Issue.4 , pp. 380-388
    • Santavirta, S.1    Bohler, M.2    Harris, W.H.3
  • 83
    • 0036023527 scopus 로고    scopus 로고
    • A literature review of the association between wear rate and osteolysis in total hip arthroplasty
    • Dumbleton JH, Manley MT, Edidin AA. A literature review of the association between wear rate and osteolysis in total hip arthroplasty. J. Arthroplasty 17, 649-661 (2002).
    • (2002) J. Arthroplasty , vol.17 , pp. 649-661
    • Dumbleton, J.H.1    Manley, M.T.2    Edidin, A.A.3
  • 84
    • 0035230836 scopus 로고    scopus 로고
    • Bearing surfaces in total hip replacements: State of the art and future developments
    • McKellop HA. Bearing surfaces in total hip replacements: state of the art and future developments. Instr. Course Lect. 50, 165-179 (2001).
    • (2001) Instr. Course Lect. , vol.50 , pp. 165-179
    • McKellop, H.A.1
  • 85
    • 10744222195 scopus 로고    scopus 로고
    • Current status of zirconia used in total hip implants
    • Clarke JC, Manaka M, Green DD et al. Current status of zirconia used in total hip implants. J. Bone Joint Surg. 85-A, 73-84 (2003).
    • (2003) J. Bone Joint Surg. , vol.85 A , pp. 73-84
    • Clarke, J.C.1    Manaka, M.2    Green, D.D.3
  • 86
    • 0037365495 scopus 로고    scopus 로고
    • Effect of terminal sterilization with gas plasma or γ radiation on wear of polyethylene liners
    • Hopper RH, Young AM, Orishimo KF, Engh CA. Effect of terminal sterilization with gas plasma or γ radiation on wear of polyethylene liners. J. Bone Joint Surg. 85-A, 464-468 (2003).
    • (2003) J. Bone Joint Surg. , vol.85 A , pp. 464-468
    • Hopper, R.H.1    Young, A.M.2    Orishimo, K.F.3    Engh, C.A.4
  • 87
    • 0035223150 scopus 로고    scopus 로고
    • Cross-linked polyethylene: Why the enthusiasm?
    • Harris WH. Cross-linked polyethylene: Why the enthusiasm? Instr. Course Lect. 50, 181-184 (2001).
    • (2001) Instr. Course Lect. , vol.50 , pp. 181-184
    • Harris, W.H.1
  • 89
    • 0033637708 scopus 로고    scopus 로고
    • Effects of sterilization method and other modifications on the wear resistance of acetabular cups made of ultra-high molecular weight polyethylene: A hip simulator study
    • McKellop H, Shen FW, Lu B, Campbell P, Salovey R. Effects of sterilization method and other modifications on the wear resistance of acetabular cups made of ultra-high molecular weight polyethylene: a hip simulator study. J. Bone Joint Surg. 82-A, 1708-1725 (2000).
    • (2000) J. Bone Joint Surg. , vol.82 A , pp. 1708-1725
    • McKellop, H.1    Shen, F.W.2    Lu, B.3    Campbell, P.4    Salovey, R.5
  • 90
    • 26844478198 scopus 로고    scopus 로고
    • Mechanical properties of retrieved highly cross-linked Crossfire liners after short-term implantation
    • Kurtz SM, Hozack WH, Turner J et al. Mechanical properties of retrieved highly cross-linked Crossfire liners after short-term implantation. J. Arthroplasty 20, 840-849 (2005).
    • (2005) J. Arthroplasty , vol.20 , pp. 840-849
    • Kurtz, S.M.1    Hozack, W.H.2    Turner, J.3
  • 91
    • 0038377243 scopus 로고    scopus 로고
    • Comparison of properties of annealed crosslinked (Crossfire) and conventional polyethylene as hip bearing materials
    • Kurtz SM, Manley M, Wang A, Taylor S, Dumbleton J. Comparison of properties of annealed crosslinked (Crossfire) and conventional polyethylene as hip bearing materials. Bull. Hosp. Joint Dis. 61, 17-26 (2003).
    • (2003) Bull. Hosp. Joint Dis. , vol.61 , pp. 17-26
    • Kurtz, S.M.1    Manley, M.2    Wang, A.3    Taylor, S.4    Dumbleton, J.5
  • 92
    • 23044492290 scopus 로고    scopus 로고
    • Clinical performance of a Durasol highly cross-linked polyethylene acetabular liner for total hip arthroplasty at five years
    • Dorr LD, Wan Z, Shahrdar C, Sirianni L, Boutary M, Yun A. Clinical performance of a Durasol highly cross-linked polyethylene acetabular liner for total hip arthroplasty at five years. J. Bone Joint Surg. 87-A, 1816-1821 (2005).
    • (2005) J. Bone Joint Surg. , vol.87 A , pp. 1816-1821
    • Dorr, L.D.1    Wan, Z.2    Shahrdar, C.3    Sirianni, L.4    Boutary, M.5    Yun, A.6
  • 93
    • 33644802015 scopus 로고    scopus 로고
    • Five-year experience with Crossfire highly cross-linked polyethylene
    • D'Antonio JA, Manley MT, Capello WN et al. Five-year experience with Crossfire highly cross-linked polyethylene. Clin. Orthop. Relat. Res. 441, 143-150 (2005).
    • (2005) Clin. Orthop. Relat. Res. , vol.441 , pp. 143-150
    • D'Antonio, J.A.1    Manley, M.T.2    Capello, W.N.3
  • 94
    • 27644448756 scopus 로고    scopus 로고
    • Effect of cross-linking on the microstructure and mechanical properties of ultra-high molecular weight polyethylene
    • Ries MD, Pruitt L. Effect of cross-linking on the microstructure and mechanical properties of ultra-high molecular weight polyethylene. Clin. Orthop. Relat. Res. 440, 149-156 (2005).
    • (2005) Clin. Orthop. Relat. Res. , vol.440 , pp. 149-156
    • Ries, M.D.1    Pruitt, L.2
  • 95
    • 2642564678 scopus 로고    scopus 로고
    • Wear and surface cracking in early retrieved highly cross-linked polyethylene acetabular liners
    • Bradford L, Baker DA, Graham J, Chawan A, Ries MD, Pruitt LA. Wear and surface cracking in early retrieved highly cross-linked polyethylene acetabular liners. J. Bone Joint Surg. 86-A, 1271-1282 (2004).
    • (2004) J. Bone Joint Surg. , vol.86 A , pp. 1271-1282
    • Bradford, L.1    Baker, D.A.2    Graham, J.3    Chawan, A.4    Ries, M.D.5    Pruitt, L.A.6
  • 96
    • 0037233869 scopus 로고    scopus 로고
    • Metal-on-metal versus polyethylene in hip arthroplasty: A randomized clinical trial
    • MacDonald SJ, McCalden RW, Chess DG et al. Metal-on-metal versus polyethylene in hip arthroplasty: a randomized clinical trial. Clin. Orthop. 406, 282-296 (2003).
    • (2003) Clin. Orthop. , vol.406 , pp. 282-296
    • MacDonald, S.J.1    McCalden, R.W.2    Chess, D.G.3
  • 97
    • 33744808260 scopus 로고    scopus 로고
    • Metallosis after contemporary metal-on-metal total hip arthroplasty. Five to nine-year-follow-up
    • Korovessis P, Petsinis G, Repanti M, Repantis T. Metallosis after contemporary metal-on-metal total hip arthroplasty. Five to nine-year-follow-up. J. Bone Joint Surg. 88-A, 1183-1191 (2006).
    • (2006) J. Bone Joint Surg. , vol.88 A , pp. 1183-1191
    • Korovessis, P.1    Petsinis, G.2    Repanti, M.3    Repantis, T.4
  • 98
    • 11844305550 scopus 로고    scopus 로고
    • An unusual lymphocytic perivascular infiltration in tissues around contemporary metal-on-metal joint replacements
    • Davies AP, Willert HG, Campbell PA, Learmonth ID, Case CP. An unusual lymphocytic perivascular infiltration in tissues around contemporary metal-on-metal joint replacements. J. Bone Joint Surg. 87-A, 18-27 (2005).
    • (2005) J. Bone Joint Surg. , vol.87 A , pp. 18-27
    • Davies, A.P.1    Willert, H.G.2    Campbell, P.A.3    Learmonth, I.D.4    Case, C.P.5
  • 99
    • 11844293972 scopus 로고    scopus 로고
    • Metal-on-metal bearings and hypersensitivity in patients with artificial hip joints. A clinical and histomorphological study
    • Willert H-G, Buchhorn GH, Fayyazi A et al. Metal-on-metal bearings and hypersensitivity in patients with artificial hip joints. A clinical and histomorphological study. J. Bone Joint Surg. 87-A, 28-36 (2005).
    • (2005) J. Bone Joint Surg. , vol.87 A , pp. 28-36
    • Willert, H.-G.1    Buchhorn, G.H.2    Fayyazi, A.3
  • 100
    • 0942298191 scopus 로고    scopus 로고
    • Biologic and tribologic considerations of alternative bearing surfaces
    • Campbell P, Shen FW, McKellop H. Biologic and tribologic considerations of alternative bearing surfaces. Clin. Orthop. Relat. Res. 418, 98-111 (2004).
    • (2004) Clin. Orthop. Relat. Res. , vol.418 , pp. 98-111
    • Campbell, P.1    Shen, F.W.2    McKellop, H.3
  • 101
    • 0029831455 scopus 로고    scopus 로고
    • In vivo wear of three types of metal on metal hip prostheses during two decades of use
    • McKellop H, Park SH, Chiesa R et al. In vivo wear of three types of metal on metal hip prostheses during two decades of use. Clin. Orthop. Relat. Res. 329(Suppl.), S128-S140 (1996).
    • (1996) Clin. Orthop. Relat. Res. , vol.329 , Issue.SUPPL.
    • McKellop, H.1    Park, S.H.2    Chiesa, R.3
  • 102
    • 33645218973 scopus 로고    scopus 로고
    • Cancer incidence and causes of death among total hip replacement patients: A review based on Nordic cohorts with a special emphasis on metal-on-metal bearings
    • Visuri TI, Pukkala E, Pulkkinen P, Paavolainen P. Cancer incidence and causes of death among total hip replacement patients: a review based on Nordic cohorts with a special emphasis on metal-on-metal bearings. Proc. Inst. Mech. Eng. (H) 220, 399-407 (2006).
    • (2006) Proc. Inst. Mech. Eng. (H) , vol.220 , pp. 399-407
    • Visuri, T.I.1    Pukkala, E.2    Pulkkinen, P.3    Paavolainen, P.4
  • 103
    • 0036380582 scopus 로고    scopus 로고
    • Ion release in patients with metal-on-metal hip bearings in total joint replacement: A comparison with metal-on-polyethylene bearings
    • Savarino L, Granchi D, Ciapetti G et al. Ion release in patients with metal-on-metal hip bearings in total joint replacement: a comparison with metal-on-polyethylene bearings. J. Biomed. Materials Res. 63, 467-474 (2002).
    • (2002) J. Biomed. Materials Res. , vol.63 , pp. 467-474
    • Savarino, L.1    Granchi, D.2    Ciapetti, G.3
  • 104
    • 0037224605 scopus 로고    scopus 로고
    • Four-year study of cobalt and chromium blood levels in patients managed with two different metal-on-metal total hip replacements
    • Lhota C, Szekeres T, Steffan I, Zhuber K, Zweymuller K. Four-year study of cobalt and chromium blood levels in patients managed with two different metal-on-metal total hip replacements. J. Orthop. Res. 21, 189-195 (2003).
    • (2003) J. Orthop. Res. , vol.21 , pp. 189-195
    • Lhota, C.1    Szekeres, T.2    Steffan, I.3    Zhuber, K.4    Zweymuller, K.5
  • 105
    • 8144223349 scopus 로고    scopus 로고
    • Cementless Metasul metal-on-metal total hip arthroplasty in patients less than fifty years old
    • Kim SY, Kyung HS, Ihn JC, Cho MR, Koo KH, Kim CY. Cementless Metasul metal-on-metal total hip arthroplasty in patients less than fifty years old. J. Bone Joint Surg. 86-A. 2475-2481 (2004).
    • (2004) J. Bone Joint Surg. , vol.86 A , pp. 2475-2481
    • Kim, S.Y.1    Kyung, H.S.2    Ihn, J.C.3    Cho, M.R.4    Koo, K.H.5    Kim, C.Y.6
  • 106
    • 9644259021 scopus 로고    scopus 로고
    • An American experience with metal-on-metal total hip arthroplasties: A 7-year follow-up study
    • Long WT, Dorr LD, Gendelman V. An American experience with metal-on-metal total hip arthroplasties: a 7-year follow-up study. J. Arthroplasty 19(8 Suppl. 3), 29-34 (2004).
    • (2004) J. Arthroplasty , vol.19 , Issue.8 SUPPL. 3 , pp. 29-34
    • Long, W.T.1    Dorr, L.D.2    Gendelman, V.3
  • 107
    • 0037243628 scopus 로고    scopus 로고
    • Alumina ceramic bearings for total hip arthroplasty
    • D'Antonio J, Capello W, Manley M. Alumina ceramic bearings for total hip arthroplasty. Orthopedics 26, 39-46 (2003).
    • (2003) Orthopedics , vol.26 , pp. 39-46
    • D'Antonio, J.1    Capello, W.2    Manley, M.3
  • 108
    • 0036083725 scopus 로고    scopus 로고
    • New experience with alumina-on-alumina ceramic bearings for total hip arthroplasty
    • D'Antonio J, Capello W, Manley M, Bierbaum B. New experience with alumina-on-alumina ceramic bearings for total hip arthroplasty. J. Arhtroplasty 17, 390-397 (2003).
    • (2003) J. Arhtroplasty , vol.17 , pp. 390-397
    • D'Antonio, J.1    Capello, W.2    Manley, M.3    Bierbaum, B.4
  • 110
    • 0031940455 scopus 로고    scopus 로고
    • Ceramics for total hip replacement: What a surgeon should know
    • William G. Ceramics for total hip replacement: what a surgeon should know. Orthopedics 21, 173-177 (1998).
    • (1998) Orthopedics , vol.21 , pp. 173-177
    • William, G.1
  • 111
    • 0024255826 scopus 로고
    • The use of dense alumina-on-alumina ceramic combination in total hip replacement
    • Boutin P, Christel P, Dorlot JM et al. The use of dense alumina-on-alumina ceramic combination in total hip replacement. J. Biomed. Materials Res. 22, 1203-1232 (1988).
    • (1988) J. Biomed. Materials Res. , vol.22 , pp. 1203-1232
    • Boutin, P.1    Christel, P.2    Dorlot, J.M.3
  • 112
    • 0037657959 scopus 로고    scopus 로고
    • Revision total hip arthroplasty performed after fracture of a ceramic femoral head: A multicenter survivorship study
    • Allain J, Roudot-Thoraval F, Delecrin J et al. Revision total hip arthroplasty performed after fracture of a ceramic femoral head: a multicenter survivorship study. J. Bone Joint Surg. 85-A, 825-830 (2003).
    • (2003) J. Bone Joint Surg. , vol.85 A , pp. 825-830
    • Allain, J.1    Roudot-Thoraval, F.2    Delecrin, J.3
  • 113
    • 1642284142 scopus 로고    scopus 로고
    • Hybrid alumina total hip arthroplasty using a press-fit metal-backed socket in patients younger than 55 years. A six- to 11 -year evaluation
    • Bizot P, Hannouche D, Nizard R, Witvoet J, Sedel L. Hybrid alumina total hip arthroplasty using a press-fit metal-backed socket in patients younger than 55 years. A six- to 11 -year evaluation. J. Bone Joint Surg. 86-B, 190-194 (2004).
    • (2004) J. Bone Joint Surg. , vol.86 B , pp. 190-194
    • Bizot, P.1    Hannouche, D.2    Nizard, R.3    Witvoet, J.4    Sedel, L.5
  • 114
    • 21844437667 scopus 로고    scopus 로고
    • Alumina ceramic bearings for total hip arthroplasty: Five-year results of a prospective randomized study
    • D'Antonio J, Capello W, Manley M, Naughton M, Sutton K. Alumina ceramic bearings for total hip arthroplasty: five-year results of a prospective randomized study. Clin. Orthop Relat. Res. 436, 164-471 (2005).
    • (2005) Clin. Orthop. Relat. Res. , vol.436 , pp. 164-471
    • D'Antonio, J.1    Capello, W.2    Manley, M.3    Naughton, M.4    Sutton, K.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.