메뉴 건너뛰기




Volumn 11, Issue 4, 1996, Pages 419-428

Comparative results of a distal modular sleeve, circumferential coating, and stiffness relief using the anatomic porous replacement II

Author keywords

fixation; porous coating; stem geometry

Indexed keywords

ACETABULOPLASTY; ADULT; AGED; ARTICLE; AVASCULAR NECROSIS; BONE ATROPHY; CLINICAL TRIAL; CONGENITAL HIP DISLOCATION; CONTROLLED CLINICAL TRIAL; CONTROLLED STUDY; CORTICAL BONE; COXITIS; FEMALE; FEMUR HEAD PROSTHESIS; GEOMETRY; HIP RADIOGRAPHY; HUMAN; MAJOR CLINICAL STUDY; MALE; METAPHYSIS; PHYSICAL PHENOMENA; REOPERATION; RHEUMATOID ARTHRITIS; RIGIDITY; TISSUE FIXATION; TOTAL HIP PROSTHESIS;

EID: 0029974887     PISSN: 08835403     EISSN: None     Source Type: Journal    
DOI: 10.1016/S0883-5403(96)80032-5     Document Type: Article
Times cited : (59)

References (17)
  • 2
  • 3
    • 0024591258 scopus 로고
    • Torsional stability of the femoral component of hip arthroplasty: Response to an anteriorly applied load
    • Nunn D, Freeman MA, Tanner KE et al: Torsional stability of the femoral component of hip arthroplasty: response to an anteriorly applied load. J Bone Joint Surg 71B:452, 1989
    • (1989) J Bone Joint Surg , vol.71 B , pp. 452
    • Nunn, D.1    Freeman, M.A.2    Tanner, K.E.3
  • 4
    • 0014525462 scopus 로고
    • Traumatic arthritis of hip after dislocation and acetabular fractures: Treatment by mold arthroplasty: an end result study using a new method of result evaluation
    • Harris WH: Traumatic arthritis of hip after dislocation and acetabular fractures: treatment by mold arthroplasty: an end result study using a new method of result evaluation. J Bone Joint Surg 51A:737, 1969
    • (1969) J Bone Joint Surg , vol.51 A , pp. 737
    • Harris, W.H.1
  • 5
    • 22644447213 scopus 로고
    • Anatomical porous replacement hip system: The interface
    • Fitzgerald R Jr (ed): Raven Press, New York
    • Dorr LD, Mackel AM: Anatomical porous replacement hip system: the interface. p. 407. In Fitzgerald R Jr (ed): Non-cemented total hip arthroplasty. Raven Press, New York, 1988
    • (1988) Non-cemented Total Hip Arthroplasty , pp. 407
    • Dorr, L.D.1    Mackel, A.M.2
  • 6
    • 0027230459 scopus 로고
    • Structural and cellular assessment of bone quality of proximal femur
    • Dorr LD, Faugere MC, Mackel AM et al: Structural and cellular assessment of bone quality of proximal femur. Bone 14:231, 1993
    • (1993) Bone , vol.14 , pp. 231
    • Dorr, L.D.1    Faugere, M.C.2    Mackel, A.M.3
  • 7
    • 0025916543 scopus 로고
    • Techniques for preoperative planning and postoperative evaluation of noncemented hip arthroplasty
    • Dossick PH, Dorr LD, Gruen T: Techniques for preoperative planning and postoperative evaluation of noncemented hip arthroplasty. Techniques Orthop 6:1, 1991
    • (1991) Techniques Orthop , vol.6 , pp. 1
    • Dossick, P.H.1    Dorr, L.D.2    Gruen, T.3
  • 8
    • 0017047304 scopus 로고
    • Radiological demarcation of cemented sockets in total hip replacement
    • Delee JG, Charnley J: Radiological demarcation of cemented sockets in total hip replacement. Clin Orthop 121:20, 1976
    • (1976) Clin Orthop , vol.121 , pp. 20
    • Delee, J.G.1    Charnley, J.2
  • 9
    • 0027499479 scopus 로고
    • Functional recovery of noncemented total hip arthroplasty
    • Long WT, Dorr LD, Healy B et al: Functional recovery of noncemented total hip arthroplasty. Clin Orthop 288:73, 1993
    • (1993) Clin Orthop , vol.288 , pp. 73
    • Long, W.T.1    Dorr, L.D.2    Healy, B.3
  • 10
    • 0023240947 scopus 로고
    • Porous-coated hip replacement: The factors governing bone ingrowth, stress shielding, and clinical results
    • Engh CA, Bobyn JD, Glassman AH: Porous-coated hip replacement: the factors governing bone ingrowth, stress shielding, and clinical results. J Bone Joint Surg 69B:45, 1987
    • (1987) J Bone Joint Surg , vol.69 B , pp. 45
    • Engh, C.A.1    Bobyn, J.D.2    Glassman, A.H.3
  • 11
    • 0019957225 scopus 로고
    • Femoral component loosening using contemporary technique of femoral cement fixation
    • Harris WH, McCarthy JC Jr, O'Neill DA: Femoral component loosening using contemporary technique of femoral cement fixation. J Bone Joint Surg 64A:1063, 1982
    • (1982) J Bone Joint Surg , vol.64 A , pp. 1063
    • Harris, W.H.1    McCarthy Jr., J.C.2    O'Neill, D.A.3
  • 12
    • 0020541681 scopus 로고
    • Total hip arthroplasties in patients less than forty-five years old
    • Dorr LD, Takei GK, Conaty JP: Total hip arthroplasties in patients less than forty-five years old. J Bone Joint Surg 65A:474, 1983
    • (1983) J Bone Joint Surg , vol.65 A , pp. 474
    • Dorr, L.D.1    Takei, G.K.2    Conaty, J.P.3
  • 13
    • 0025165926 scopus 로고
    • Total hip arthroplasty in patients younger than 45 years: A nine to ten years follow up study
    • Dorr LD, Luckett M, Conaty JP: Total hip arthroplasty in patients younger than 45 years: a nine to ten years follow up study. Clin Orthop 260:215, 1990
    • (1990) Clin Orthop , vol.260 , pp. 215
    • Dorr, L.D.1    Luckett, M.2    Conaty, J.P.3
  • 14
    • 0028139402 scopus 로고
    • Long-term results of cemented total hip arthroplasty in patients 45 years old or younger: A 16-year follow up study
    • Dorr LD, Kane TJ, Conaty JP: Long-term results of cemented total hip arthroplasty in patients 45 years old or younger: a 16-year follow up study. J Arthroplasty 9:453, 1994
    • (1994) J Arthroplasty , vol.9 , pp. 453
    • Dorr, L.D.1    Kane, T.J.2    Conaty, J.P.3
  • 15
    • 0028123590 scopus 로고
    • Omniflex modular femoral component: Two- To five-year results
    • Capello WN, Sallay PI, Feinberg JR: Omniflex modular femoral component: two- to five-year results. Clin Orthop 298:54, 1994
    • (1994) Clin Orthop , vol.298 , pp. 54
    • Capello, W.N.1    Sallay, P.I.2    Feinberg, J.R.3
  • 16
    • 0024951004 scopus 로고
    • Cementless total hip replacement using the anatomic medullary locking stem: Results using a survivorship analysis
    • Engh CA, Massin P: Cementless total hip replacement using the anatomic medullary locking stem: results using a survivorship analysis. Clin Orthop 249:141, 1989
    • (1989) Clin Orthop , vol.249 , pp. 141
    • Engh, C.A.1    Massin, P.2
  • 17
    • 0028054273 scopus 로고
    • Taperloc femoral component: A 2-6 years study of the first 100 consecutive cases
    • Hozack W, Gardiner R, Hearn S et al: Taperloc femoral component: a 2-6 years study of the first 100 consecutive cases. J Arthroplasty 9:489, 1994
    • (1994) J Arthroplasty , vol.9 , pp. 489
    • Hozack, W.1    Gardiner, R.2    Hearn, S.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.