Digital radiography using active matrix readout of amorphous selenium: Construction and evaluation of a prototype real-time detector
W Zhao I Blevis S Germann 1997 Digital radiography using active matrix readout of amorphous selenium: construction and evaluation of a prototype real-time detector Med Phys 24 1834 1843
Empirical and theoretical investigation of the noise performance of indirect detection, active matrix flat-panel imagers (AMFPIs) for diagnostic radiography
JH Siewerdesn LE Antonuk Y EI-Mohri 1997 Empirical and theoretical investigation of the noise performance of indirect detection, active matrix flat-panel imagers (AMFPIs) for diagnostic radiography Med Phys 24 71 89
New CsI/a-Si 17″ × 17″ x-ray flat-panel detector provides superior directivity and immediate direct digital output for general radiography systems
C Chaussat J Chabbal T Ducourant 1998 New CsI/a-Si 17″ × 17″ x-ray flat-panel detector provides superior directivity and immediate direct digital output for general radiography systems Proc SPIE 3336 45 56
Performance of a 41 cm × 41 cm amorphous silicon flat panel x-ray detector for radiographic imaging applications
PR Granfors R Aufrichtig 2000 Performance of a 41 cm × 41 cm amorphous silicon flat panel x-ray detector for radiographic imaging applications Med Phys 27 1324 1331
Imaging characteristics of an amorphous silicon flat-panel detector for digital chest radiography
CE Floyd RJ Warp Jr JT Dobbins 2001 Imaging characteristics of an amorphous silicon flat-panel detector for digital chest radiography Radiology 218 683 688
A comprehensive physical image quality evaluation of a selenium based digital x-ray imaging system for thorax radiography
JH Launders SM Kengyelics AR Cowen 1998 A comprehensive physical image quality evaluation of a selenium based digital x-ray imaging system for thorax radiography Med Phys 25 986 997
International Electrotechnical Commission, Switzerland
IEC62220-1: Medical electrorical equipment-characteristics of digital X-ray imaging devices-Part 1: Determination of the detective quantum efficiency, International Electrotechnical Commission, Switzerland, 2003
A method for measuring the presampled MTF of digital radiographic systems using an edge test device
E Samei MJ Flynn DA Reimann 1998 A method for measuring the presampled MTF of digital radiographic systems using an edge test device Med Phys 25 102 113
International Commission on Radiation Units and Measurements: International Commission on Radiation Units and Measurements, Bethesda, MD
International Commission on Radiation Units and Measurements: Medical imaging-the assessment of image quality, ICRU Report No. 54, International Commission on Radiation Units and Measurements, Bethesda, MD, 1996