메뉴 건너뛰기




Volumn 4190 LNCS - I, Issue , 2006, Pages 33-40

A pilot study of robot-assisted cochlear implant surgery using steerable electrode arrays

Author keywords

[No Author keywords available]

Indexed keywords

ELECTRODES; MOTION PLANNING; ROBOT APPLICATIONS; ROBOTICS;

EID: 33750254841     PISSN: 03029743     EISSN: 16113349     Source Type: Book Series    
DOI: 10.1007/11866565_5     Document Type: Conference Paper
Times cited : (21)

References (18)
  • 1
    • 23344447785 scopus 로고    scopus 로고
    • A model for cochlear implant electrode insertion and force evaluation: Results with a new electrode design and insertion technique
    • Roland, T., A model for cochlear implant electrode insertion and force evaluation: results with a new electrode design and insertion technique. The Laryngeoscope, 2005. 115(august): p. 1325-1339.
    • (2005) The Laryngeoscope , vol.115 , Issue.AUGUST , pp. 1325-1339
    • Roland, T.1
  • 2
    • 0037336982 scopus 로고    scopus 로고
    • Comparative study of cochlear damage with three perimodiolar electride designs
    • Eshraghi, A., N. Yang, and T. Balkany, Comparative Study of Cochlear Damage with Three Perimodiolar Electride Designs. The Laryngeoscope, 2003. 113: p. 415-419.
    • (2003) The Laryngeoscope , vol.113 , pp. 415-419
    • Eshraghi, A.1    Yang, N.2    Balkany, T.3
  • 3
    • 18044377967 scopus 로고    scopus 로고
    • A temporal bone study of insertion trauma and intracochlear position of cochlear implant electrodes I: Comparison of Nucleus banded and Nucleus Contour electrodes
    • Wardrop, P., et al., A temporal bone study of insertion trauma and intracochlear position of cochlear implant electrodes I: comparison of Nucleus banded and Nucleus Contour electrodes. Hearing Research, 2005. 203: p. 54-67.
    • (2005) Hearing Research , vol.203 , pp. 54-67
    • Wardrop, P.1
  • 4
    • 18044386764 scopus 로고    scopus 로고
    • A temporal bone study of insertion trauma and intracochlear position of cochlear implant electrodes II: Comparison of spiral clariontrade mark and HiFocus IItrade mark electrodes banded and Nucleus Contour electrodes
    • Wardrop, P., et al., A temporal bone study of insertion trauma and intracochlear position of cochlear implant electrodes II: comparison of spiral clariontrade mark and HiFocus IItrade mark electrodes banded and Nucleus Contour electrodes. Hearing Research, 2005. 203: p. 68-79.
    • (2005) Hearing Research , vol.203 , pp. 68-79
    • Wardrop, P.1
  • 10
    • 33750246192 scopus 로고    scopus 로고
    • The kinematics of hyper-redundant robots
    • ed. J. Baillieul, S. Sastry, and H. Sussmann. Springer-Verlag
    • Burdick, J.W. and G. Chirikjian, The Kinematics of Hyper-Redundant Robots. The IMA Volumes in Mathematics and its Applications, ed. J. Baillieul, S. Sastry, and H. Sussmann. Vol. 104. 1998: Springer-Verlag.
    • (1998) The IMA Volumes in Mathematics and Its Applications , vol.104
    • Burdick, J.W.1    Chirikjian, G.2
  • 15
    • 0029868754 scopus 로고    scopus 로고
    • Improved and simplified methods for specifying positions of the electrode bands of a cochlear implant array
    • Cohen, L., et al., Improved and Simplified Methods for Specifying Positions of the Electrode bands of a Cochlear Implant Array. The American Journal of Otology, 1996. 17: p. 859-865.
    • (1996) The American Journal of Otology , vol.17 , pp. 859-865
    • Cohen, L.1
  • 16
    • 0032215286 scopus 로고    scopus 로고
    • In vivo measures of cochlear length and insertion depth of Nucleus cochlear implant electrode arrays
    • Ketten, D.R., et al., In vivo measures of cochlear length and insertion depth of Nucleus cochlear implant electrode arrays. Ann. Otol. Rhinol. Laryngol., 1998. 107(12): p. 1-16.
    • (1998) Ann. Otol. Rhinol. Laryngol. , vol.107 , Issue.12 , pp. 1-16
    • Ketten, D.R.1
  • 17
    • 0033625487 scopus 로고    scopus 로고
    • Three-dimensional modeling and visualization of the cochlea on the internet
    • Yoo, S.K., et al., Three-Dimensional Modeling and Visualization of the Cochlea on the Internet. IEEE Transactions on Information Technology in Biomedicine, 2000. 4(2): p. 144-151.
    • (2000) IEEE Transactions on Information Technology in Biomedicine , vol.4 , Issue.2 , pp. 144-151
    • Yoo, S.K.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.