메뉴 건너뛰기




Volumn 56, Issue 4, 2006, Pages 754-760

On restoring motion-induced signal loss in single-voxel magnetic resonance spectra

Author keywords

Artifact reduction; Motion correction; MRS; Spectral processing

Indexed keywords

MAGNETIC RESONANCE; MAGNETIC RESONANCE SPECTROSCOPY; PARTICLE DETECTORS; PRESSES (MACHINE TOOLS); SIGNAL RECONSTRUCTION;

EID: 33749167998     PISSN: 07403194     EISSN: 15222594     Source Type: Journal    
DOI: 10.1002/mrm.21015     Document Type: Article
Times cited : (42)

References (23)
  • 1
    • 0032492358 scopus 로고    scopus 로고
    • Noninvasive MRS detection of localized creatine depletion in non-viable, infarcted myocardium
    • Bottomley PA, Weiss RG. Noninvasive MRS detection of localized creatine depletion in non-viable, infarcted myocardium. Lancet 1998; 351:714-718.
    • (1998) Lancet , vol.351 , pp. 714-718
    • Bottomley, P.A.1    Weiss, R.G.2
  • 2
    • 0032710765 scopus 로고    scopus 로고
    • Methods and reproducibility of cardiac/respiratory double-triggered 1H-MR spectroscopy of the human heart
    • Felblinger J, Jung B, Slotboom J, Boesch C, Kreis R. Methods and reproducibility of cardiac/respiratory double-triggered 1H-MR spectroscopy of the human heart. Magn Reson Med 1999;42:903-910.
    • (1999) Magn Reson Med , vol.42 , pp. 903-910
    • Felblinger, J.1    Jung, B.2    Slotboom, J.3    Boesch, C.4    Kreis, R.5
  • 5
    • 0041315396 scopus 로고    scopus 로고
    • Breathhold abdominal and thoracic proton MR spectroscopy at 3T
    • Katz-Brull R, Rofsky NM, Lenkinski RE. Breathhold abdominal and thoracic proton MR spectroscopy at 3T. Magn Reson Med 2003;50:461-467.
    • (2003) Magn Reson Med , vol.50 , pp. 461-467
    • Katz-Brull, R.1    Rofsky, N.M.2    Lenkinski, R.E.3
  • 6
    • 0028298119 scopus 로고
    • Localized proton MR spectroscopy of the human kidney in vivo by means of short echo time STEAM sequences
    • Dixon RM, Frahm J. Localized proton MR spectroscopy of the human kidney in vivo by means of short echo time STEAM sequences. Magn Reson Med 199431:482-487.;
    • (1994) Magn Reson Med , vol.31 , pp. 482-487
    • Dixon, R.M.1    Frahm, J.2
  • 7
    • 2942714876 scopus 로고    scopus 로고
    • Navigator gating and volume tracking for double-triggered cardiac proton spectroscopy at 3 Tesla
    • Schär M, Kozerke S, Boesiger P. Navigator gating and volume tracking for double-triggered cardiac proton spectroscopy at 3 Tesla. Magn Reson Med 2004;51:1091-1095.
    • (2004) Magn Reson Med , vol.51 , pp. 1091-1095
    • Schär, M.1    Kozerke, S.2    Boesiger, P.3
  • 8
    • 0032077809 scopus 로고    scopus 로고
    • Effects of physiologic motion of the human brain upon quantitative 1H-MRS: Analysis and correction by retrogating
    • Felblinger J, Kreis R, Boesch C. Effects of physiologic motion of the human brain upon quantitative 1H-MRS: analysis and correction by retrogating. NMR Biomed 1998;11:107-114.
    • (1998) NMR Biomed , vol.11 , pp. 107-114
    • Felblinger, J.1    Kreis, R.2    Boesch, C.3
  • 9
    • 0009236807 scopus 로고
    • Motion artifact compensation in 1H spectroscopic imaging by signal tracking
    • Posse S, Cuenod CA, LeBihan D. Motion artifact compensation in 1H spectroscopic imaging by signal tracking. J Magn Reson 1993;102:222-227.
    • (1993) J Magn Reson , vol.102 , pp. 222-227
    • Posse, S.1    Cuenod, C.A.2    LeBihan, D.3
  • 10
    • 0026894094 scopus 로고
    • Motional degradation of metabolite signal strengths when using STEAM: A correction method
    • Zhu G, Gheorghiu D, Allen PS. Motional degradation of metabolite signal strengths when using STEAM: a correction method. NMR Biomed 1992;5:209-211.
    • (1992) NMR Biomed , vol.5 , pp. 209-211
    • Zhu, G.1    Gheorghiu, D.2    Allen, P.S.3
  • 11
    • 0001127267 scopus 로고
    • Signal-to-noise improvement in in vivo spin-echo spectroscopy in the presence of motion
    • Ziegler A, Decorps M. Signal-to-noise improvement in in vivo spin-echo spectroscopy in the presence of motion. J Magn Reson B 1993; 102:26-34.
    • (1993) J Magn Reson B , vol.102 , pp. 26-34
    • Ziegler, A.1    Decorps, M.2
  • 12
    • 0005253298 scopus 로고    scopus 로고
    • Constructive averaging increases SNR of creatine MRS in the presence of motion
    • Philadelphia, PA, USA
    • Bottomley PA, Lee RF, Weiss RG. Constructive averaging increases SNR of creatine MRS in the presence of motion. In: Proceedings of the 7th Annual Meeting of ISMRM, Philadelphia, PA, USA, 1999. p 687.
    • (1999) Proceedings of the 7th Annual Meeting of ISMRM , pp. 687
    • Bottomley, P.A.1    Lee, R.F.2    Weiss, R.G.3
  • 14
    • 0034900222 scopus 로고    scopus 로고
    • Restoration of motion-related signal loss and line-shape deterioration of proton MR spectra using the residual water as intrinsic reference
    • Helms G, Piringer A. Restoration of motion-related signal loss and line-shape deterioration of proton MR spectra using the residual water as intrinsic reference. Magn Reson Med 2001;46:395-400.
    • (2001) Magn Reson Med , vol.46 , pp. 395-400
    • Helms, G.1    Piringer, A.2
  • 15
    • 10044229567 scopus 로고    scopus 로고
    • Measurement and correction of respiration-induced B0 variations in breast 1H MRS at 4 Tesla
    • Bolan PJ, Henry PG, Baker EH, Meisamy S, Garwood M. Measurement and correction of respiration-induced B0 variations in breast 1H MRS at 4 Tesla. Magn Reson Med 2004;52:1239-1245.
    • (2004) Magn Reson Med , vol.52 , pp. 1239-1245
    • Bolan, P.J.1    Henry, P.G.2    Baker, E.H.3    Meisamy, S.4    Garwood, M.5
  • 17
    • 0028839871 scopus 로고
    • The Rician distribution of noisy MRI data
    • Gudbjartsson H, Patz S. The Rician distribution of noisy MRI data. Magn Reson Med 1995;34:910-914.
    • (1995) Magn Reson Med , vol.34 , pp. 910-914
    • Gudbjartsson, H.1    Patz, S.2
  • 18
    • 0037596767 scopus 로고    scopus 로고
    • Coherent integration loss due to white Gaussian phase noise
    • Richards MA. Coherent integration loss due to white Gaussian phase noise. IEEE Signal Proc Lett 2003;10:208-210.
    • (2003) IEEE Signal Proc Lett , vol.10 , pp. 208-210
    • Richards, M.A.1
  • 20
    • 0031959485 scopus 로고    scopus 로고
    • In-plane motion correction for MR spectroscopic imaging
    • Haupt CI, Kiefer AP, Maudsley AA. In-plane motion correction for MR spectroscopic imaging. Magn Reson Med 1998;39:749-753.
    • (1998) Magn Reson Med , vol.39 , pp. 749-753
    • Haupt, C.I.1    Kiefer, A.P.2    Maudsley, A.A.3
  • 21
    • 0033867569 scopus 로고    scopus 로고
    • The effect of respiratory motion on CSI localized MRS
    • Doyle VL, Howet FA, Griffiths JR. The effect of respiratory motion on CSI localized MRS. Phys Med Biol 2000;45:2093-2104.
    • (2000) Phys Med Biol , vol.45 , pp. 2093-2104
    • Doyle, V.L.1    Howet, F.A.2    Griffiths, J.R.3
  • 23
    • 1542286646 scopus 로고    scopus 로고
    • Spiral readout gradients for the reduction of motion artifacts in chemical shift imaging
    • Kim DH, Adalsteinsson E, Spielman DM. Spiral readout gradients for the reduction of motion artifacts in chemical shift imaging. Magn Reson Med 2004;51:458-463.
    • (2004) Magn Reson Med , vol.51 , pp. 458-463
    • Kim, D.H.1    Adalsteinsson, E.2    Spielman, D.M.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.