메뉴 건너뛰기




Volumn 51, Issue 6, 2004, Pages 1091-1095

Navigator gating and volume tracking for double-triggered cardiac proton spectroscopy at 3 Tesla

Author keywords

3 Tesla; Cardiac magnetic resonance spectroscopy; Double trigger; Localized higher order shimming; Navigator motion compensation; Navigator volume tracking

Indexed keywords

MAGNETIC RESONANCE; MAGNETIC RESONANCE SPECTROSCOPY; MOTION COMPENSATION; RESPIRATORY MECHANICS;

EID: 2942714876     PISSN: 07403194     EISSN: None     Source Type: Journal    
DOI: 10.1002/mrm.20123     Document Type: Article
Times cited : (51)

References (14)
  • 1
    • 0027998937 scopus 로고
    • Observation of cardiac lipids in humans by localized 1H magnetic resonance spectroscopic imaging
    • den Hollander JA, Evanochko WT, Pohost GM. Observation of cardiac lipids in humans by localized 1H magnetic resonance spectroscopic imaging. Magn Reson Med 1994;32:175-180.
    • (1994) Magn Reson Med , vol.32 , pp. 175-180
    • Den Hollander, J.A.1    Evanochko, W.T.2    Pohost, G.M.3
  • 3
    • 0032492358 scopus 로고    scopus 로고
    • Non-invasive magnetic-resonance detection of creatine depletion in non-viable infarcted myocardium
    • Bottomley PA, Weiss RG. Non-invasive magnetic-resonance detection of creatine depletion in non-viable infarcted myocardium. Lancet 1998;351:714-718.
    • (1998) Lancet , vol.351 , pp. 714-718
    • Bottomley, P.A.1    Weiss, R.G.2
  • 4
    • 0032710765 scopus 로고    scopus 로고
    • Methods and reproducibility of cardiac/respiratory double-triggered (1)H-MR spectroscopy of the human heart
    • Felblinger J, Jung B, Slotboom J, Boesch C, Kreis R. Methods and reproducibility of cardiac/respiratory double-triggered (1)H-MR spectroscopy of the human heart. Magn Reson Med 1999;42:903-910.
    • (1999) Magn Reson Med , vol.42 , pp. 903-910
    • Felblinger, J.1    Jung, B.2    Slotboom, J.3    Boesch, C.4    Kreis, R.5
  • 5
    • 0030026702 scopus 로고    scopus 로고
    • Navigator-echo-based real-time respiratory gating and triggering for reduction of respiration effects in three-dimensional coronary MR angiography
    • Wang Y, Rossman PJ, Grimm RC, Riederer SJ, Ehman RL. Navigator-echo-based real-time respiratory gating and triggering for reduction of respiration effects in three-dimensional coronary MR angiography. Radiology 1996;198:55-60.
    • (1996) Radiology , vol.198 , pp. 55-60
    • Wang, Y.1    Rossman, P.J.2    Grimm, R.C.3    Riederer, S.J.4    Ehman, R.L.5
  • 7
    • 0031964426 scopus 로고    scopus 로고
    • Navigated single-voxel proton spectroscopy of the human liver
    • Tyszka JM, Silverman JM. Navigated single-voxel proton spectroscopy of the human liver. Magn Reson Med 1998;39:1-5.
    • (1998) Magn Reson Med , vol.39 , pp. 1-5
    • Tyszka, J.M.1    Silverman, J.M.2
  • 9
    • 0035033720 scopus 로고    scopus 로고
    • Single-voxel proton MRS of the human brain at 1.5T and 3.0T
    • Barker PB, Hearshen DO, Boska MD. Single-voxel proton MRS of the human brain at 1.5T and 3.0T. Magn Reson Med 2001;45:765-769.
    • (2001) Magn Reson Med , vol.45 , pp. 765-769
    • Barker, P.B.1    Hearshen, D.O.2    Boska, M.D.3
  • 13
    • 0023636904 scopus 로고
    • Spatial localization in NMR spectroscopy in vivo
    • Bottomley PA. Spatial localization in NMR spectroscopy in vivo. Ann NY Acad Sci 1987;508:333-348.
    • (1987) Ann NY Acad Sci , vol.508 , pp. 333-348
    • Bottomley, P.A.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.