메뉴 건너뛰기




Volumn 50, Issue 3, 2003, Pages 461-467

Breathhold abdominal and thoracic proton MR spectroscopy at 3T

Author keywords

3T; Body; Breathhold; Proton MR spectroscopy

Indexed keywords

METABOLITES;

EID: 0041315396     PISSN: 07403194     EISSN: None     Source Type: Journal    
DOI: 10.1002/mrm.10560     Document Type: Article
Times cited : (70)

References (22)
  • 1
    • 0032977735 scopus 로고    scopus 로고
    • Motion artifact control in body MR imaging
    • Barish MA, Jara H. Motion artifact control in body MR imaging. Magn Reson Imag Clin N Am 1999;7:289-301.
    • (1999) Magn Reson Imag Clin N Am , vol.7 , pp. 289-301
    • Barish, M.A.1    Jara, H.2
  • 2
    • 0032858862 scopus 로고    scopus 로고
    • A computationally efficient method for tracking reference position displacements for motion compensation in magnetic resonance imaging
    • Foo TK, King KF. A computationally efficient method for tracking reference position displacements for motion compensation in magnetic resonance imaging. Magn Reson Med 1999;42:548-553.
    • (1999) Magn Reson Med , vol.42 , pp. 548-553
    • Foo, T.K.1    King, K.F.2
  • 4
    • 0025267867 scopus 로고
    • Rapid acquisition spin-echo (RASE) MR imaging: A new technique for reduction of artifacts and acquisition time
    • Mirowitz SA, Lee JK, Brown JJ, Eilenberg SS, Heiken JP, Perman WH. Rapid acquisition spin-echo (RASE) MR imaging: a new technique for reduction of artifacts and acquisition time. Radiology 1990;175:131-135.
    • (1990) Radiology , vol.175 , pp. 131-135
    • Mirowitz, S.A.1    Lee, J.K.2    Brown, J.J.3    Eilenberg, S.S.4    Heiken, J.P.5    Perman, W.H.6
  • 5
    • 0022260368 scopus 로고
    • Respiratory ordered phase encoding (ROPE): A method of reducing respiratory motion artefacts in MR imaging
    • Bailes DR, Gilderdale DJ, Bydder GM, Collins AG, Firmin DN. Respiratory ordered phase encoding (ROPE): a method of reducing respiratory motion artefacts in MR imaging. J Comput Assist Tomogr 1985;9:835-838.
    • (1985) J Comput Assist Tomogr , vol.9 , pp. 835-838
    • Bailes, D.R.1    Gilderdale, D.J.2    Bydder, G.M.3    Collins, A.G.4    Firmin, D.N.5
  • 7
    • 0032928635 scopus 로고    scopus 로고
    • Echo-train STIR MRI of the liver: Comparison of breath-hold and non-breath-hold imaging strategies
    • Earls JP, Rofsky NM, DeCorato DR, Krinsky GA, Weinreb JC. Echo-train STIR MRI of the liver: comparison of breath-hold and non-breath-hold imaging strategies. J Magn Reson Imag 1999;9:87-92.
    • (1999) J Magn Reson Imag , vol.9 , pp. 87-92
    • Earls, J.P.1    Rofsky, N.M.2    DeCorato, D.R.3    Krinsky, G.A.4    Weinreb, J.C.5
  • 8
    • 0025144653 scopus 로고
    • Segmented turboFLASH: Method for breath-hold MR imaging of the liver with flexible contrast
    • Edelman RR, Wallner B, Singer A, Atkinson DJ, Saini S. Segmented turboFLASH: method for breath-hold MR imaging of the liver with flexible contrast. Radiology 1990;177:515-521.
    • (1990) Radiology , vol.177 , pp. 515-521
    • Edelman, R.R.1    Wallner, B.2    Singer, A.3    Atkinson, D.J.4    Saini, S.5
  • 9
    • 0029953063 scopus 로고    scopus 로고
    • Replacement of conventional T2-weighted imaging with breath-hold MR imaging
    • Gaa J, Hatabu H, Jenkins RJ, Finn JP, Edelman RR. Replacement of conventional T2-weighted imaging with breath-hold MR imaging. Radiology 1996;200:459-464.
    • (1996) Radiology , vol.200 , pp. 459-464
    • Gaa, J.1    Hatabu, H.2    Jenkins, R.J.3    Finn, J.P.4    Edelman, R.R.5
  • 11
    • 0031401343 scopus 로고    scopus 로고
    • Breath-holding in healthy and pulmonary-compromised populations: Effects of hyperventilation and oxygen inspiration
    • Marks B, Mitchell DG, Simelaro JP. Breath-holding in healthy and pulmonary-compromised populations: effects of hyperventilation and oxygen inspiration. J Magn Reson Imag 1997;7:595-597.
    • (1997) J Magn Reson Imag , vol.7 , pp. 595-597
    • Marks, B.1    Mitchell, D.G.2    Simelaro, J.P.3
  • 12
    • 0028865810 scopus 로고
    • Multiple breath hold average (MBA) method for increased SNR in rapid abdominal MRI
    • Feinberg DA, Rofsky NM, Johnson G. Multiple breath hold average (MBA) method for increased SNR in rapid abdominal MRI. Magn Reson Med 1995;34:905-909.
    • (1995) Magn Reson Med , vol.34 , pp. 905-909
    • Feinberg, D.A.1    Rofsky, N.M.2    Johnson, G.3
  • 14
    • 0031964426 scopus 로고    scopus 로고
    • Navigated single-voxel proton spectroscopy of the human liver
    • Tyszka JM, Silverman JM. Navigated single-voxel proton spectroscopy of the human liver. Magn Reson Med 1998;39:1-5.
    • (1998) Magn Reson Med , vol.39 , pp. 1-5
    • Tyszka, J.M.1    Silverman, J.M.2
  • 18
    • 0021254071 scopus 로고
    • NMR even echo rephasing in slow laminar-flow
    • Waluch V, Bradley WG. NMR even echo rephasing in slow laminar-flow. J Comput Assist Tomogr 1984;8:594-598.
    • (1984) J Comput Assist Tomogr , vol.8 , pp. 594-598
    • Waluch, V.1    Bradley, W.G.2
  • 21
    • 0034845169 scopus 로고    scopus 로고
    • A generalized approach to parallel magnetic resonance imaging
    • Sodickson DK, McKenzie CA. A generalized approach to parallel magnetic resonance imaging. Med Phys 2001;28:1629-1643.
    • (2001) Med Phys , vol.28 , pp. 1629-1643
    • Sodickson, D.K.1    McKenzie, C.A.2
  • 22
    • 0033867569 scopus 로고    scopus 로고
    • The effect of respiratory motion on CSI localized MRS
    • Cooperative Group on MR Applications to Cancer
    • Doyle VL, Howet FA, Griffiths JR. The effect of respiratory motion on CSI localized MRS. Cooperative Group on MR Applications to Cancer. Phys Med Biol 2000;45:2093-2104.
    • (2000) Phys Med Biol , vol.45 , pp. 2093-2104
    • Doyle, V.L.1    Howet, F.A.2    Griffiths, J.R.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.