메뉴 건너뛰기




Volumn 11, Issue 3, 1998, Pages 107-114

Effects of physiologic motion of the human brain upon quantitative 1H- MRS: Analysis and correction by retrogating

Author keywords

Brain; ECG gating; H MRS; Quantitation; Retro gating

Indexed keywords

BRAIN; DISPERSION (WAVES); ELECTROCARDIOGRAPHY; MAGNETIC RESONANCE IMAGING; METABOLITES; PHYSIOLOGY; SIGNAL PROCESSING;

EID: 0032077809     PISSN: 09523480     EISSN: None     Source Type: Journal    
DOI: 10.1002/(SICI)1099-1492(199805)11:3<107::AID-NBM525>3.0.CO;2-I     Document Type: Article
Times cited : (39)

References (29)
  • 2
    • 0029312360 scopus 로고
    • In vivo quantitation of metabolite concentrations in the brain by means of proton MRS
    • Henriksen O. In vivo quantitation of metabolite concentrations in the brain by means of proton MRS. HMR Biomed. 8, 139-148 (1995).
    • (1995) HMR Biomed. , vol.8 , pp. 139-148
    • Henriksen, O.1
  • 3
    • 0000927648 scopus 로고    scopus 로고
    • 1H-MR spectroscopy for clinical use
    • 1H-MR spectroscopy for clinical use. Prog. NMR Spectroscopy 31, 155-195 (1997).
    • (1997) Prog. NMR Spectroscopy , vol.31 , pp. 155-195
    • Kreis, R.1
  • 4
    • 0029118783 scopus 로고
    • Retrospective estimation and correction of physiological fluctuation in functional MRI
    • Hu X., Le T. H., Parrish T. and Erhard P. Retrospective estimation and correction of physiological fluctuation in functional MRI. Magn. Reson. Med. 34, 201-212 (1995).
    • (1995) Magn. Reson. Med. , vol.34 , pp. 201-212
    • Hu, X.1    Le, T.H.2    Parrish, T.3    Erhard, P.4
  • 5
    • 0026485075 scopus 로고
    • Brain motion: Measurement with phase-contrast MR imaging
    • Enzmann D. R. and Pelc N. J. Brain motion: measurement with phase-contrast MR imaging. Radiology 185, 653-660 (1992).
    • (1992) Radiology , vol.185 , pp. 653-660
    • Enzmann, D.R.1    Pelc, N.J.2
  • 6
    • 0026463748 scopus 로고
    • Brain parenchyma motion: Measurement with cine echo-planar MR imaging
    • Poncelet B. P., Wedeen V. J., Weisskoff R. M. and Cohen M. S. Brain parenchyma motion: measurement with cine echo-planar MR imaging. Radiology 185, 645-651 (1992).
    • (1992) Radiology , vol.185 , pp. 645-651
    • Poncelet, B.P.1    Wedeen, V.J.2    Weisskoff, R.M.3    Cohen, M.S.4
  • 7
    • 0027960917 scopus 로고
    • Brain and cerebrospinal fluid motion: Realtime quantification with M-mode MR imaging
    • Maier S. E., Hardy C. J. and Jolesz F. A. Brain and cerebrospinal fluid motion: realtime quantification with M-mode MR imaging. Radiology 193, 477-483 (1994).
    • (1994) Radiology , vol.193 , pp. 477-483
    • Maier, S.E.1    Hardy, C.J.2    Jolesz, F.A.3
  • 9
    • 0028324684 scopus 로고
    • Correction of motional artifacts in diffusion-weighted MR images using navigator echoes
    • Ordidge R. J., Helpern J. A., Qing Z. X., Knight R. A. and Nagesh V. Correction of motional artifacts in diffusion-weighted MR images using navigator echoes. Magn. Reson. Imag. 12, 455-460 (1994).
    • (1994) Magn. Reson. Imag. , vol.12 , pp. 455-460
    • Ordidge, R.J.1    Helpern, J.A.2    Qing, Z.X.3    Knight, R.A.4    Nagesh, V.5
  • 10
    • 0028183287 scopus 로고
    • Funktionelle Spektroskopie: Grenzen und Moeglichkeiten einer neuen Methode zur Untersuchung der Hirnaktivierung mit Kernspintomographie
    • Hennig J., Laubenberger J., Ernst T., Speck O., Feifel E., Deuschl G. and Langer M. Funktionelle Spektroskopie: Grenzen und Moeglichkeiten einer neuen Methode zur Untersuchung der Hirnaktivierung mit Kernspintomographie. RoFo 161, 51-57 (1994).
    • (1994) RoFo , vol.161 , pp. 51-57
    • Hennig, J.1    Laubenberger, J.2    Ernst, T.3    Speck, O.4    Feifel, E.5    Deuschl, G.6    Langer, M.7
  • 12
    • 0026894094 scopus 로고
    • Motional degradation of metabolite signal strengths when using STEAM: A correction method
    • Zhu G., Gheorghiu D. and Allen P. S. Motional degradation of metabolite signal strengths when using STEAM: a correction method. NMR Biomed. 5, 209-211 (1992).
    • (1992) NMR Biomed. , vol.5 , pp. 209-211
    • Zhu, G.1    Gheorghiu, D.2    Allen, P.S.3
  • 13
    • 0001127267 scopus 로고
    • Signal-to-noise improvement in in vivo spin-echo spectroscopy in the presence of motion
    • Ziegler A. and Decorps M. Signal-to-noise improvement in in vivo spin-echo spectroscopy in the presence of motion. J. Magn. Reson. Series B 102, 26-34 (1993).
    • (1993) J. Magn. Reson. Series B , vol.102 , pp. 26-34
    • Ziegler, A.1    Decorps, M.2
  • 14
    • 0009236807 scopus 로고
    • Motion artifact compensation in 1H spectroscopic imaging by signal tracking
    • Posse S., Cuenod C. A. and LeBihan D. Motion artifact compensation in 1H spectroscopic imaging by signal tracking. J. Magn. Reson. Series B 102, 222-227 (1993).
    • (1993) J. Magn. Reson. Series B , vol.102 , pp. 222-227
    • Posse, S.1    Cuenod, C.A.2    LeBihan, D.3
  • 15
    • 0027265566 scopus 로고
    • Human brain. Proton diffusion MR spectroscopy
    • Posse S., Cuenod C. A. and LeBihan D. Human brain. Proton diffusion MR spectroscopy. Radiology 188, 719-725 (1993).
    • (1993) Radiology , vol.188 , pp. 719-725
    • Posse, S.1    Cuenod, C.A.2    LeBihan, D.3
  • 16
    • 0024835363 scopus 로고
    • Comparison of single-shot localization methods (STEAM and PRESS) for in vivo proton NMR spectroscopy
    • Moonen C. T. W., von Kienlin M., van Zijl P. C. M., Cohen J., Gillen J., Daly P. and Wolf G. Comparison of single-shot localization methods (STEAM and PRESS) for in vivo proton NMR spectroscopy. NMR Biomed. 2, 201-208 (1989).
    • (1989) NMR Biomed. , vol.2 , pp. 201-208
    • Moonen, C.T.W.1    Von Kienlin, M.2    Van Zijl, P.C.M.3    Cohen, J.4    Gillen, J.5    Daly, P.6    Wolf, G.7
  • 17
    • 0000085492 scopus 로고
    • Selected volume excitation using stimulated echoes (VEST). Applications to spatially localized spectroscopy and imaging
    • Granot J. Selected volume excitation using stimulated echoes (VEST). Applications to spatially localized spectroscopy and imaging. J. Magn. Reson. 70, 488-492 (1986).
    • (1986) J. Magn. Reson. , vol.70 , pp. 488-492
    • Granot, J.1
  • 18
    • 45949115041 scopus 로고
    • Volume-selective multipulse spin-echo spectroscopy
    • Kimmich R. and Hoepfel D. Volume-selective multipulse spin-echo spectroscopy. J. Magn. Reson. 72, 379-384 (1987).
    • (1987) J. Magn. Reson. , vol.72 , pp. 379-384
    • Kimmich, R.1    Hoepfel, D.2
  • 19
    • 45949114306 scopus 로고
    • Localized proton spectroscopy using stimulated echoes
    • Frahm J., Merboldt K. D. and Haenicke W. Localized proton spectroscopy using stimulated echoes. J. Magn. Reson. 72, 502-508 (1987).
    • (1987) J. Magn. Reson. , vol.72 , pp. 502-508
    • Frahm, J.1    Merboldt, K.D.2    Haenicke, W.3
  • 20
    • 0028224243 scopus 로고
    • Automated single-voxel proton MRS: Technical development and multisite verification
    • Webb P. G., Sailasuta N., Kohler S. J., Raidy T., Moats R. A. and Hurd R. E. Automated single-voxel proton MRS: technical development and multisite verification. Magn. Reson. Med. 31, 365-373 (1994).
    • (1994) Magn. Reson. Med. , vol.31 , pp. 365-373
    • Webb, P.G.1    Sailasuta, N.2    Kohler, S.J.3    Raidy, T.4    Moats, R.A.5    Hurd, R.E.6
  • 21
    • 0002909727 scopus 로고
    • Highly effective water suppression for in vivo proton NMR spectroscopy (DRYSTEAM)
    • Moonen C. T. W. and van Zijl P. C. M. Highly effective water suppression for in vivo proton NMR spectroscopy (DRYSTEAM). J. Magn. Reson. 88, 28-41 (1990).
    • (1990) J. Magn. Reson. , vol.88 , pp. 28-41
    • Moonen, C.T.W.1    Van Zijl, P.C.M.2
  • 22
    • 0028524876 scopus 로고
    • Electrocardiogram acquisition during MR examinations for patient monitoring and sequence triggering
    • Felblinger J., Lehmann C. and Boesch C. Electrocardiogram acquisition during MR examinations for patient monitoring and sequence triggering. Magn. Reson. Med. 32, 523-529 (1994).
    • (1994) Magn. Reson. Med. , vol.32 , pp. 523-529
    • Felblinger, J.1    Lehmann, C.2    Boesch, C.3
  • 24
    • 0010239571 scopus 로고    scopus 로고
    • Reproducible quantitative 1H-MR spectroscopy of the human heart using double triggering
    • Abstract
    • Felblinger J., Kreis R., Jung B., Slotboorn J. and Boesch C. Reproducible quantitative 1H-MR spectroscopy of the human heart using double triggering. MAGMA 4 (suppl), 78 (1996) (Abstract).
    • (1996) MAGMA , vol.4 , Issue.SUPPL. , pp. 78
    • Felblinger, J.1    Kreis, R.2    Jung, B.3    Slotboorn, J.4    Boesch, C.5
  • 25
    • 0027345896 scopus 로고
    • Quantitation of proton NMR spectra of the human brain using tissue water as an internal concentration reference
    • Barker P. B., Soher B. J., Blackband S. J., Chatham J. C., Mathews V. P. and Bryan R. N. Quantitation of proton NMR spectra of the human brain using tissue water as an internal concentration reference. NMR Biomed. 6, 89-94 (1993).
    • (1993) NMR Biomed. , vol.6 , pp. 89-94
    • Barker, P.B.1    Soher, B.J.2    Blackband, S.J.3    Chatham, J.C.4    Mathews, V.P.5    Bryan, R.N.6
  • 26
  • 28
    • 0029155699 scopus 로고
    • Correction of motional artifacts in diffusion-weighted images using a reference phase map
    • Ulug A. M., Barker P. B. and van Zijl P. C. M. Correction of motional artifacts in diffusion-weighted images using a reference phase map. Magn. Reson. Med. 34, 476-480 (1995).
    • (1995) Magn. Reson. Med. , vol.34 , pp. 476-480
    • Ulug, A.M.1    Barker, P.B.2    Van Zijl, P.C.M.3
  • 29
    • 0030747734 scopus 로고    scopus 로고
    • Amplitude demodulation of the electroardiogram signal (ECG) for respiration monitoring and compensation during MR examinations
    • Felblinger J. and Boesch C. Amplitude demodulation of the electroardiogram signal (ECG) for respiration monitoring and compensation during MR examinations. Magn. Reson. Med. 38, 129-136 (1997).
    • (1997) Magn. Reson. Med. , vol.38 , pp. 129-136
    • Felblinger, J.1    Boesch, C.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.