메뉴 건너뛰기




Volumn 18, Issue 6, 2003, Pages 745-749

Application of the Keyhole Technique to T1ρ Relaxation Mapping

Author keywords

Efficiency; Keyhole; Magnetic resonance imaging; Relaxation mapping; T1p

Indexed keywords

ARTICLE; CATTLE; CORRELATION ANALYSIS; HUMAN; KNEE; NONHUMAN; NUCLEAR MAGNETIC RESONANCE IMAGING; PHANTOM; PRIORITY JOURNAL; REGRESSION ANALYSIS; SIMULATION; STANDARDIZATION; STATISTICAL ANALYSIS; TECHNIQUE;

EID: 0344153786     PISSN: 10531807     EISSN: None     Source Type: Journal    
DOI: 10.1002/jmri.10412     Document Type: Article
Times cited : (26)

References (27)
  • 1
    • 0015046195 scopus 로고
    • Biochemical and metabolic abnormalities in articular cartilage from osteo-arthritic human hips. II. Correlation of morphology with biochemical and metabolic data
    • Mankin HJ, Dorfman H, Lippiello L, Zarins A. Biochemical and metabolic abnormalities in articular cartilage from osteo-arthritic human hips. II. Correlation of morphology with biochemical and metabolic data. J Bone Joint Surg Am 1971;53:523-537.
    • (1971) J Bone Joint Surg Am , vol.53 , pp. 523-537
    • Mankin, H.J.1    Dorfman, H.2    Lippiello, L.3    Zarins, A.4
  • 2
    • 0034852133 scopus 로고    scopus 로고
    • Proteoglycan-induced changes in T1rho-relaxation of articular cartilage at 4T
    • Akella SV, Regatte RR, Gougoutas AJ, et al. Proteoglycan-induced changes in T1rho-relaxation of articular cartilage at 4T. Magn Reson Med 2001;46:419-423.
    • (2001) Magn Reson Med , vol.46 , pp. 419-423
    • Akella, S.V.1    Regatte, R.R.2    Gougoutas, A.J.3
  • 3
    • 0037219788 scopus 로고    scopus 로고
    • Proton spin-lock ratio imaging for quantitation of glycosaminoglycans in articular cartilage
    • Regatte RR, Akella SV, Borthakur A, Reddy R. Proton spin-lock ratio imaging for quantitation of glycosaminoglycans in articular cartilage. J Magn Reson Imaging 2003;17:114-121.
    • (2003) J Magn Reson Imaging , vol.17 , pp. 114-121
    • Regatte, R.R.1    Akella, S.V.2    Borthakur, A.3    Reddy, R.4
  • 5
    • 0034871410 scopus 로고    scopus 로고
    • Human knee: In vivo T1(rho)-weighted MR imaging at 1.5 T-preliminary experience
    • Duvvuri U, Charagundla SR, Kudchodkar SB, et al. Human knee: in vivo T1(rho)-weighted MR imaging at 1.5 T-preliminary experience. Radiology 2001;220:822-826.
    • (2001) Radiology , vol.220 , pp. 822-826
    • Duvvuri, U.1    Charagundla, S.R.2    Kudchodkar, S.B.3
  • 8
    • 0032587954 scopus 로고    scopus 로고
    • Fast T1 mapping on a whole-body scanner
    • Deichmann R, Hahn D, Haase A. Fast T1 mapping on a whole-body scanner. Magn Reson Med 1999;42:206-209.
    • (1999) Magn Reson Med , vol.42 , pp. 206-209
    • Deichmann, R.1    Hahn, D.2    Haase, A.3
  • 9
    • 0027256155 scopus 로고
    • Quantification of regional blood volumes by rapid T1 mapping
    • Schwarzbauer C, Syha J, Haase A. Quantification of regional blood volumes by rapid T1 mapping. Magn Reson Med 1993;29:709-712.
    • (1993) Magn Reson Med , vol.29 , pp. 709-712
    • Schwarzbauer, C.1    Syha, J.2    Haase, A.3
  • 10
    • 0014732355 scopus 로고
    • Time saving in measurement of NMR and EPR relaxation times
    • Look DC, Locker DR. Time saving In measurement of NMR and EPR relaxation times. Rev Sci Instrum 1970:41:250-251.
    • (1970) Rev Sci Instrum , vol.41 , pp. 250-251
    • Look, D.C.1    Locker, D.R.2
  • 11
    • 0027337153 scopus 로고
    • Accurate measurement of T1 in vivo in less than 3 seconds using echo-planar imaging
    • Gowland P, Mansfield P. Accurate measurement of T1 in vivo in less than 3 seconds using echo-planar imaging. Magn Reson Med 1993;30:351-354.
    • (1993) Magn Reson Med , vol.30 , pp. 351-354
    • Gowland, P.1    Mansfield, P.2
  • 12
    • 0032736504 scopus 로고    scopus 로고
    • Phantom and in vivo study of the Look-Locher T1 mapping method
    • Karlsson M, Nordell B. Phantom and in vivo study of the Look-Locher T1 mapping method. Magn Reson Imaging 1999;17:1481-1488.
    • (1999) Magn Reson Imaging , vol.17 , pp. 1481-1488
    • Karlsson, M.1    Nordell, B.2
  • 13
    • 0036338505 scopus 로고    scopus 로고
    • Rapid simultaneous mapping of T2 and T2* by multiple acquisition of spin and gradient echoes using interleaved echo planar imaging (MASAGE-IEPI)
    • Thomas DL, Lythgoe MF, Gadian DG, Ordidge RJ. Rapid simultaneous mapping of T2 and T2* by multiple acquisition of spin and gradient echoes using interleaved echo planar imaging (MASAGE-IEPI). Neuroimage 2002;15:992-1002.
    • (2002) Neuroimage , vol.15 , pp. 992-1002
    • Thomas, D.L.1    Lythgoe, M.F.2    Gadian, D.G.3    Ordidge, R.J.4
  • 14
    • 0036021698 scopus 로고    scopus 로고
    • Radial fast spin-echo method for T2-weighted imaging and T2 mapping of the liver
    • Altbach MI, Outwater EK, Trouard TP, et al. Radial fast spin-echo method for T2-weighted imaging and T2 mapping of the liver. J Magn Reson Imaging 2002;16:179-189.
    • (2002) J Magn Reson Imaging , vol.16 , pp. 179-189
    • Altbach, M.I.1    Outwater, E.K.2    Trouard, T.P.3
  • 16
    • 0027633059 scopus 로고
    • "Keyhole" method for accelerating imaging of contrast agent uptake
    • van Vaals JJ, Brummer ME, Dixon WT, et al. "Keyhole" method for accelerating imaging of contrast agent uptake. J Magn Reson Imaging 1993;3:671-675.
    • (1993) J Magn Reson Imaging , vol.3 , pp. 671-675
    • Van Vaals, J.J.1    Brummer, M.E.2    Dixon, W.T.3
  • 19
    • 0029894499 scopus 로고    scopus 로고
    • Improving the temporal resolution of functional MR imaging using keyhole techniques
    • Gao JH, Xiong J, Lai S, et al. Improving the temporal resolution of functional MR imaging using keyhole techniques. Magn Reson Med 1996;35:854-860.
    • (1996) Magn Reson Med , vol.35 , pp. 854-860
    • Gao, J.H.1    Xiong, J.2    Lai, S.3
  • 23
    • 0030276850 scopus 로고    scopus 로고
    • Application of keyhole imaging to interventional MRI: A simulation study to predict sequence requirements
    • Duerk JL, Lewin JS, Wu DH. Application of keyhole imaging to interventional MRI: a simulation study to predict sequence requirements. J Magn Reson Imaging 1996;6:918-924.
    • (1996) J Magn Reson Imaging , vol.6 , pp. 918-924
    • Duerk, J.L.1    Lewin, J.S.2    Wu, D.H.3
  • 24
  • 25
    • 0033366653 scopus 로고    scopus 로고
    • The carotid artery through a keyhole
    • Bowen B. The carotid artery through a keyhole. AJNR Am J Neuroradiol 1999;20:186-187.
    • (1999) AJNR Am J Neuroradiol , vol.20 , pp. 186-187
    • Bowen, B.1
  • 26
    • 0029018452 scopus 로고
    • Multislice first-pass myocardial perfusion imaging on a conventional clinical scanner
    • Walsh EG, Doyle M, Lawson MA, Blackwell GG, Pohost GM. Multislice first-pass myocardial perfusion imaging on a conventional clinical scanner. Magn Reson Med 1995:34:39-47.
    • (1995) Magn Reson Med , vol.34 , pp. 39-47
    • Walsh, E.G.1    Doyle, M.2    Lawson, M.A.3    Blackwell, G.G.4    Pohost, G.M.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.