메뉴 건너뛰기




Volumn 177, Issue 11, 2005, Pages 1491-1496

Initial clinical results with a new needle screen storage phosphor system in chest radiograms

Author keywords

Digital radiography; Radiation safety; Radiography; Technical aspects; Technology assessment; Thorax

Indexed keywords

PHOSPHORUS;

EID: 28044467731     PISSN: 14389029     EISSN: None     Source Type: Journal    
DOI: 10.1055/s-2005-858687     Document Type: Article
Times cited : (25)

References (22)
  • 1
    • 0035204969 scopus 로고    scopus 로고
    • Developments in digital radiography: An equipment update
    • James JJ, Davies AG, Cowen AR et al. Developments in digital radiography: an equipment update. Eur Radiol 2001; 11: 2616-2626
    • (2001) Eur Radiol , vol.11 , pp. 2616-2626
    • James, J.J.1    Davies, A.G.2    Cowen, A.R.3
  • 2
    • 0032754840 scopus 로고    scopus 로고
    • Detection of simulated interstitial lung disease and catheters with selenium, storage phosphor, and film-based radiography
    • Bernhardt TM, Otto D, Reichel G et al. Detection of simulated interstitial lung disease and catheters with selenium, storage phosphor, and film-based radiography. Radiology 1999; 213: 445-454
    • (1999) Radiology , vol.213 , pp. 445-454
    • Bernhardt, T.M.1    Otto, D.2    Reichel, G.3
  • 3
    • 0035740395 scopus 로고    scopus 로고
    • Efficacy of daily bedside chest radiography as visualized by digital luminescence radiography
    • Kirchner J, Stueckle CA, Schilling EM et al. Efficacy of daily bedside chest radiography as visualized by digital luminescence radiography. Australas Radiol 2001; 45: 444-447
    • (2001) Australas Radiol , vol.45 , pp. 444-447
    • Kirchner, J.1    Stueckle, C.A.2    Schilling, E.M.3
  • 4
    • 0030279516 scopus 로고    scopus 로고
    • ROC-analysis of detection performance by analogue and digital plain film systems in chest radiography
    • Müller RD, Wähling S, Hirche H et al. ROC-analysis of detection performance by analogue and digital plain film systems in chest radiography. Acta Radiol 1996; 37: 847-854
    • (1996) Acta Radiol , vol.37 , pp. 847-854
    • Müller, R.D.1    Wähling, S.2    Hirche, H.3
  • 6
    • 0037780679 scopus 로고    scopus 로고
    • Neue CR-Technologien für die digitale radiographie
    • Fasbender R, Schaetzing R. Neue CR-Technologien für die digitale Radiographie. Radiologe 2003; 43: 367-373
    • (2003) Radiologe , vol.43 , pp. 367-373
    • Fasbender, R.1    Schaetzing, R.2
  • 7
    • 0033625293 scopus 로고    scopus 로고
    • A new needle-crystalline computed radiography detector
    • Leblans P, Struye L, Willems P. A new needle-crystalline computed radiography detector. J Digit Imaging 2000; 13: 117-120
    • (2000) J Digit Imaging , vol.13 , pp. 117-120
    • Leblans, P.1    Struye, L.2    Willems, P.3
  • 8
    • 3042546856 scopus 로고    scopus 로고
    • Measurement of the Detective. Quantum Efficiency (DQE) of digital X-ray imaging devices according to the standard IEC 62220-1
    • Illers H, Buhr E, Bergmann D et al. Measurement of the Detective. Quantum Efficiency (DQE) of digital X-ray imaging devices according to the standard IEC 62220-1. Proc SPIE 2004: 177-187
    • (2004) Proc SPIE , pp. 177-187
    • Illers, H.1    Buhr, E.2    Bergmann, D.3
  • 9
    • 23844489226 scopus 로고    scopus 로고
    • Reflective and transmissive CR scanHead technology on needle image plates
    • Frankenberger J, Mair S, Herrmann C et al. Reflective and Transmissive CR ScanHead Technology on Needle Image Plates. Proc SPIE 2005: 499-510
    • (2005) Proc SPIE , pp. 499-510
    • Frankenberger, J.1    Mair, S.2    Herrmann, C.3
  • 10
    • 0032754757 scopus 로고    scopus 로고
    • Reduktion der strahlendosis mittels speicherfolienradiographie im vergleich zum konventionellen Film-Folien-System mit rasterkassette am schädelphantom
    • Heyne JP, Merbold H, Sehner J et al. Reduktion der Strahlendosis mittels Speicherfolienradiographie im Vergleich zum konventionellen Film-Folien-System mit Rasterkassette am Schädelphantom. Fortschr Röntgenstr 1999; 171: 54-59
    • (1999) Fortschr Röntgenstr , vol.171 , pp. 54-59
    • Heyne, J.P.1    Merbold, H.2    Sehner, J.3
  • 11
    • 0034070794 scopus 로고    scopus 로고
    • Reduktion der strahlendosis mittels speicherfolienradiographie am handphantom
    • Heyne JP, Merbold H, Sehner J et al. Reduktion der Strahlendosis mittels Speicherfolienradiographie am Handphantom. Fortschr Röntgenstr 2000; 172: 386-390
    • (2000) Fortschr Röntgenstr , vol.172 , pp. 386-390
    • Heyne, J.P.1    Merbold, H.2    Sehner, J.3
  • 12
    • 0036180222 scopus 로고    scopus 로고
    • Reduktion der strahlenexposition mittels speicherfolienradiographie an becken und lendenwirbelsäule
    • Heyne JP, Sehner J, Neumann R et al. Reduktion der Strahlenexposition mittels Speicherfolienradiographie an Becken und Lendenwirbelsäule. Fortschr Röntgenstr 2002; 174: 104-111
    • (2002) Fortschr Röntgenstr , vol.174 , pp. 104-111
    • Heyne, J.P.1    Sehner, J.2    Neumann, R.3
  • 13
    • 0036598378 scopus 로고    scopus 로고
    • Storage phosphor radiography of wrist fractures: A subjective comparison of image quality at varying exposure levels
    • Peer R, Lanser A, Giacomuzzi SM et al. Storage phosphor radiography of wrist fractures: a subjective comparison of image quality at varying exposure levels. Eur Radiol 2002; 12: 1354-1359
    • (2002) Eur Radiol , vol.12 , pp. 1354-1359
    • Peer, R.1    Lanser, A.2    Giacomuzzi, S.M.3
  • 14
    • 3042630418 scopus 로고    scopus 로고
    • Bildqualität und dosis in der digitalen projektionsradiographie
    • Busch HP, Busch S, Decker C et al. Bildqualität und Dosis in der Digitalen Projektionsradiographie. Fortschr Röntgenstr 2003; 175: 32-37
    • (2003) Fortschr Röntgenstr , vol.175 , pp. 32-37
    • Busch, H.P.1    Busch, S.2    Decker, C.3
  • 15
    • 0037251071 scopus 로고    scopus 로고
    • Thoraxübersichtsaufnahme: ROC-phantomstudie an vier verschiedenen digitalen und einem konventionellen röntgenaufnahmesystem
    • Redlich U, Reissberg S, Hoeschen C et al. Thoraxübersichtsaufnahme: ROC-Phantomstudie an vier verschiedenen digitalen und einem konventionellen Röntgenaufnahmesystem. Fortschr Röntgenstr 2003; 175: 38-45
    • (2003) Fortschr Röntgenstr , vol.175 , pp. 38-45
    • Redlich, U.1    Reissberg, S.2    Hoeschen, C.3
  • 16
    • 0141855190 scopus 로고    scopus 로고
    • Dose reduction in patients undergoing chest imaging: Digital amorphous silicon flat-panel detector radiography versus conventional film-screen radiography and phosphor-based computed radiography
    • Bacher K, Smeets P, Bonnarens K et al. Dose reduction in patients undergoing chest imaging: digital amorphous silicon flat-panel detector radiography versus conventional film-screen radiography and phosphor-based computed radiography. AJR Am J Roentgenol 2003; 181: 923-929
    • (2003) AJR Am J Roentgenol , vol.181 , pp. 923-929
    • Bacher, K.1    Smeets, P.2    Bonnarens, K.3
  • 17
    • 0043244882 scopus 로고    scopus 로고
    • Chest imaging with flat-panel detector at low and standard doses: Comparison with storage phosphor technology in normal patients
    • Herrmann A, Bonel H, Stabler A et al. Chest imaging with flat-panel detector at low and standard doses: comparison with storage phosphor technology in normal patients. Eur Radiol 2002; 12: 385-390
    • (2002) Eur Radiol , vol.12 , pp. 385-390
    • Herrmann, A.1    Bonel, H.2    Stabler, A.3
  • 18
    • 0036135625 scopus 로고    scopus 로고
    • Routine chest radiography using a flat-panel detector, image quality at standard detector dose and 33% dose reduction
    • Strotzer M, Volk M, Frund R et al. Routine chest radiography using a flat-panel detector, image quality at standard detector dose and 33% dose reduction. AJR Am J Roentgenol 2002; 178; 169-171
    • (2002) AJR Am J Roentgenol , vol.178 , pp. 169-171
    • Strotzer, M.1    Volk, M.2    Frund, R.3
  • 19
    • 2542425641 scopus 로고    scopus 로고
    • Dose reduction in skeletal and chest radiography using a large-area flat-panel detector based on amorphous silicon and thallium-doped cesium iodide: Technical background, basic image quality parameters, and review of the literature
    • Volk M, Hamer OW, Feuerbach S et al. Dose reduction in skeletal and chest radiography using a large-area flat-panel detector based on amorphous silicon and thallium-doped cesium iodide: technical background, basic image quality parameters, and review of the literature. Eur Radiol 2004; 14: 827-834
    • (2004) Eur Radiol , vol.14 , pp. 827-834
    • Volk, M.1    Hamer, O.W.2    Feuerbach, S.3
  • 20
    • 2142702254 scopus 로고    scopus 로고
    • Skeletal applications for flat-panel versus storage-phosphor radiography: Effect of exposure on detection of low-contrast details
    • Uffmann M, Schaefer-Prokop C, Neitzel U et al. Skeletal applications for flat-panel versus storage-phosphor radiography: effect of exposure on detection of low-contrast details. Radiology 2004; 231: 506-514
    • (2004) Radiology , vol.231 , pp. 506-514
    • Uffmann, M.1    Schaefer-Prokop, C.2    Neitzel, U.3
  • 21
    • 0032767558 scopus 로고    scopus 로고
    • Comparison of low contrast detectability between a digital amorphous silicon and a screen-film based imaging system for thoracic radiography
    • Aufrichtig R. Comparison of low contrast detectability between a digital amorphous silicon and a screen-film based imaging system for thoracic radiography. Med Phys 1999; 26: 1349-1358
    • (1999) Med Phys , vol.26 , pp. 1349-1358
    • Aufrichtig, R.1
  • 22
    • 13944284459 scopus 로고    scopus 로고
    • Vergleich von vier digitalen und einem konventionellen röntgenaufnahmesystem für den thorax mittels einer patientenstudie mit nachfolgender systemoptimierung
    • Redlich U, Hoeschen C, Effenberger O et al. Vergleich von vier digitalen und einem konventionellen Röntgenaufnahmesystem für den Thorax mittels einer Patientenstudie mit nachfolgender Systemoptimierung. Fortschr Röntgenstr 2005; 177: 272-278
    • (2005) Fortschr Röntgenstr , vol.177 , pp. 272-278
    • Redlich, U.1    Hoeschen, C.2    Effenberger, O.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.