Computed radiography and direct radiography: Influence of acquisition dose on the detection of simulated lung lesions

Author keywords

Chest radiography; Comparative study; Computed radiography; Digital radiography; Experimental study; Exposure settings; ROC analysis

Indexed keywords

ANALYSIS OF VARIANCE; ANTHROPOMETRIC PARAMETERS; ARTICLE; COMPUTER ASSISTED TOMOGRAPHY; DIGITAL RADIOGRAPHY; EVALUATION; IMAGE PROCESSING; IMAGE QUALITY; INTERMETHOD COMPARISON; LUNG DISEASE; NONHUMAN; PHANTOM; PHOSPHOR RADIOGRAPHY SYSTEM; PRIORITY JOURNAL; RADIATION ATTENUATION; RADIATION DETECTION; RADIATION DOSE; RECEIVER OPERATING CHARACTERISTIC; SIMULATION; STATISTICAL SIGNIFICANCE;

EID: 17644379010     PISSN: 00209996     EISSN: None     Source Type: Journal    
DOI: 10.1097/01.rli.0000159875.01324.bf     Document Type: Article
Times cited : (24)

References (20)
  • 2
    • 0033742471 scopus 로고    scopus 로고
    • Comparison of low-contrast detail detectability with five different conventional and digital radiographic imaging systems
    • Neitzel U, Boehm A, Maack I. Comparison of low-contrast detail detectability with five different conventional and digital radiographic imaging systems. Proc SPIE Int Soc Opt Eng. 2000;3981:216-223.
    • (2000) Proc SPIE Int Soc Opt Eng , vol.3981 , pp. 216-223
    • Neitzel, U.1    Boehm, A.2    Maack, I.3
  • 3
    • 0035185721 scopus 로고    scopus 로고
    • Comparison of an amorphous silicon/ cesium iodide flat-panel digital chest radiography system with screen/ film and computed radiography systems - A contrast-detail phantom study
    • Rong X, Shaw C, Liu X, et al. Comparison of an amorphous silicon/ cesium iodide flat-panel digital chest radiography system with screen/ film and computed radiography systems-a contrast-detail phantom study. Med Phys. 2001;28:2328-2335.
    • (2001) Med Phys , vol.28 , pp. 2328-2335
    • Rong, X.1    Shaw, C.2    Liu, X.3
  • 4
    • 0035119131 scopus 로고    scopus 로고
    • Imaging characteristics of an amorphous silicon flat-panel detector for digital chest radiography
    • Floyd C, Warp R, Dobbins J, et al. Imaging characteristics of an amorphous silicon flat-panel detector for digital chest radiography. Radiology. 2001;218:683-688.
    • (2001) Radiology , vol.218 , pp. 683-688
    • Floyd, C.1    Warp, R.2    Dobbins, J.3
  • 5
    • 0036135625 scopus 로고    scopus 로고
    • Routine chest radiography using a flat-panel detector: Image quality at standard detector dose and 33% dose reduction
    • Strotzer M, Volk M, Frund R, et al. Routine chest radiography using a flat-panel detector: image quality at standard detector dose and 33% dose reduction. Am J Roentgenol. 2002;178:169-171.
    • (2002) Am J Roentgenol , vol.178 , pp. 169-171
    • Strotzer, M.1    Volk, M.2    Frund, R.3
  • 6
    • 0035560182 scopus 로고    scopus 로고
    • Image quality vs. radiation dose for a flat-panel amorphous silicon detector: A phantom study
    • Geijer H, Beckman KW, Andersson T, et al. Image quality vs. radiation dose for a flat-panel amorphous silicon detector: a phantom study. Eur Radiol. 2001;11:1704-1709.
    • (2001) Eur Radiol , vol.11 , pp. 1704-1709
    • Geijer, H.1    Beckman, K.W.2    Andersson, T.3
  • 7
    • 0027231117 scopus 로고
    • Improved parameters for unsharp mask filtering of digital chest radiographs
    • Prokop M, Schaefer C, Oestmann J, et al. Improved parameters for unsharp mask filtering of digital chest radiographs. Radiology. 1993; 187:521-526.
    • (1993) Radiology , vol.187 , pp. 521-526
    • Prokop, M.1    Schaefer, C.2    Oestmann, J.3
  • 8
    • 2442700387 scopus 로고    scopus 로고
    • Comparison of an automatic versus a semiautomatic mode for gray-scale adaptation for digital chest radiography
    • Sailer J, Prokop M, Neitzel U, et al. Comparison of an automatic versus a semiautomatic mode for gray-scale adaptation for digital chest radiography. Invest Radiol. 2004;39:325-333.
    • (2004) Invest Radiol , vol.39 , pp. 325-333
    • Sailer, J.1    Prokop, M.2    Neitzel, U.3
  • 9
    • 0030791269 scopus 로고    scopus 로고
    • Improvement of signal-to-noise and contrast-to-noise ratios in dual-screen computed radiography
    • Shaw C, Wang T, Breitenstein D, et al. Improvement of signal-to-noise and contrast-to-noise ratios in dual-screen computed radiography. Med Phys. 1997;24:1293-1302.
    • (1997) Med Phys , vol.24 , pp. 1293-1302
    • Shaw, C.1    Wang, T.2    Breitenstein, D.3
  • 10
    • 0037382624 scopus 로고    scopus 로고
    • Amorphous silicon, flat-panel, x-ray detector versus storage phosphor-based computed radiography: Contrast-detail phantom study at different tube voltages and detector entrance doses
    • Hamer OW, Volk M, Zorger Z, et al. Amorphous silicon, flat-panel, x-ray detector versus storage phosphor-based computed radiography: contrast-detail phantom study at different tube voltages and detector entrance doses. Invest Radiol. 2003;38:212-220.
    • (2003) Invest Radiol , vol.38 , pp. 212-220
    • Hamer, O.W.1    Volk, M.2    Zorger, Z.3
  • 11
    • 0035263307 scopus 로고    scopus 로고
    • Comparison of low-contrast detail perception on storage phosphor radiographs and digital flat panel detector images
    • Peer S, Neitzel U, Giacomuzzi SM, et al. Comparison of low-contrast detail perception on storage phosphor radiographs and digital flat panel detector images. IEEE Trans Med Imaging. 2001;20:239-242.
    • (2001) IEEE Trans Med Imaging , vol.20 , pp. 239-242
    • Peer, S.1    Neitzel, U.2    Giacomuzzi, S.M.3
  • 12
    • 0342647521 scopus 로고    scopus 로고
    • Chest radiography with a large-area detector based on cesium-iodide/amorphous-silicon technology: Image quality and dose requirement in comparison with an asymmetric screen-film system
    • Strotzer M, Volk M, Reiser M, et al. Chest radiography with a large-area detector based on cesium-iodide/amorphous-silicon technology: image quality and dose requirement in comparison with an asymmetric screen-film system. J Thorac Imaging. 2000;15:157-161.
    • (2000) J Thorac Imaging , vol.15 , pp. 157-161
    • Strotzer, M.1    Volk, M.2    Reiser, M.3
  • 13
    • 0033985984 scopus 로고    scopus 로고
    • Digital radiography versus conventional radiography in chest imaging: Diagnostic performance of a large-area silicon flat-panel detector in a clinical CT-controlled study
    • Garmer M, Hennigs S, Jager H, et al. Digital radiography versus conventional radiography in chest imaging: diagnostic performance of a large-area silicon flat-panel detector in a clinical CT-controlled study. AJR Am J Roentgenol. 2000;174:75-80.
    • (2000) AJR Am J Roentgenol , vol.174 , pp. 75-80
    • Garmer, M.1    Hennigs, S.2    Jager, H.3
  • 14
    • 0034839073 scopus 로고    scopus 로고
    • Digital chest radiography with a large-area flat-panel silicon X-ray detector: Clinical comparison with conventional radiography
    • Hennigs S, Garmer M, Jaeger H, et al. Digital chest radiography with a large-area flat-panel silicon X-ray detector: clinical comparison with conventional radiography. Eur Radiol. 2001;11:1688-1696.
    • (2001) Eur Radiol , vol.11 , pp. 1688-1696
    • Hennigs, S.1    Garmer, M.2    Jaeger, H.3
  • 15
    • 0037251071 scopus 로고    scopus 로고
    • Chest radiography: ROC phantom study of four different digital systems and one conventional radiographic system
    • Redlich U, Reissberg S, Hoeschen C, et al. Chest radiography: ROC phantom study of four different digital systems and one conventional radiographic system [in German]. Rofo. 2003;175:38-45.
    • (2003) Rofo , vol.175 , pp. 38-45
    • Redlich, U.1    Reissberg, S.2    Hoeschen, C.3
  • 16
    • 0037382844 scopus 로고    scopus 로고
    • Detection of monitoring materials on bedside chest radiographs with the most recent generation of storage phosphor plates: Dose increase does not improve detection performance
    • Eisenhuber E, Stadler A, Prokop M, et al. Detection of monitoring materials on bedside chest radiographs with the most recent generation of storage phosphor plates: dose increase does not improve detection performance. Radiology. 2003;227:216-221.
    • (2003) Radiology , vol.227 , pp. 216-221
    • Eisenhuber, E.1    Stadler, A.2    Prokop, M.3
  • 17
    • 0037962482 scopus 로고    scopus 로고
    • Performance evaluation of a "dual-side read" dedicated mammography computed radiography system
    • Fetterly KA, Schueler BA. Performance evaluation of a "dual-side read" dedicated mammography computed radiography system. Med Phys. 2003;30:1843-1854.
    • (2003) Med Phys , vol.30 , pp. 1843-1854
    • Fetterly, K.A.1    Schueler, B.A.2
  • 18
    • 0032812524 scopus 로고    scopus 로고
    • Experimental comparison of noise and resolution for 2k and 4k storage phosphor radiography systems
    • Flynn MJ, Samei E. Experimental comparison of noise and resolution for 2k and 4k storage phosphor radiography systems. Med Phys. 1999; 26:1612-1623.
    • (1999) Med Phys , vol.26 , pp. 1612-1623
    • Flynn, M.J.1    Samei, E.2
  • 19
    • 0037875820 scopus 로고    scopus 로고
    • Impact of increased matrix size on the performance of storage phosphor chest radiographs
    • Strasser GR, Schaefer-Prokop CM, Boehm P, et al. Impact of increased matrix size on the performance of storage phosphor chest radiographs. Radiology. 2001;221:354.
    • (2001) Radiology , vol.221 , pp. 354
    • Strasser, G.R.1    Schaefer-Prokop, C.M.2    Boehm, P.3
  • 20
    • 0035143259 scopus 로고    scopus 로고
    • Digital storage phosphor chest radiography: An ROC study of the effect of 2K versus 4K matrix size on observer performance
    • Miro SP, Leung AN, Rubin GD, et al. Digital storage phosphor chest radiography: an ROC study of the effect of 2K versus 4K matrix size on observer performance. Radiology. 2001;218:527-532.
    • (2001) Radiology , vol.218 , pp. 527-532
    • Miro, S.P.1    Leung, A.N.2    Rubin, G.D.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.