메뉴 건너뛰기




Volumn 17, Issue 9, 2006, Pages 992-997

Management of far-field R wave sensing for the avoidance of inappropriate mode switch in dual chamber pacemakers: Results of the FFS-test study

Author keywords

Dual chamber pacemaker; Mode switch; Pacemaker diagnostics

Indexed keywords

ADULT; AGED; ARTICLE; ARTIFICIAL HEART PACEMAKER; ATRIOVENTRICULAR BLOCK; CLINICAL TRIAL; CONTROLLED CLINICAL TRIAL; CONTROLLED STUDY; DUAL CHAMBER PACEMAKER; FAR FIELD R WAVE SENSING; FEMALE; HEMODYNAMICS; HOLTER MONITORING; HOSPITAL DISCHARGE; HUMAN; MAJOR CLINICAL STUDY; MALE; PRIORITY JOURNAL; R WAVE; RANDOMIZED CONTROLLED TRIAL; RELIABILITY; SINUS NODE DISEASE; STANDARD; SUPRAVENTRICULAR TACHYCARDIA; TREATMENT INDICATION;

EID: 33747316320     PISSN: 10453873     EISSN: 15408167     Source Type: Journal    
DOI: 10.1111/j.1540-8167.2006.00545.x     Document Type: Article
Times cited : (30)

References (22)
  • 2
    • 33747221767 scopus 로고    scopus 로고
    • True incidence of far-field R wave oversensing during chronic DDD pacing
    • Abstract
    • Geroux L, Cazeau S, Mabo P: True incidence of far-field R wave oversensing during chronic DDD pacing. Pacing Clin Electrophysiol 2001;24:566 (Abstract).
    • (2001) Pacing Clin Electrophysiol , vol.24 , pp. 566
    • Geroux, L.1    Cazeau, S.2    Mabo, P.3
  • 4
    • 0034021440 scopus 로고    scopus 로고
    • Far-field QRS complex sensing: Prevalence and timing with bipolar atrial leads
    • Brandt J, Worzewski W: Far-field QRS complex sensing: Prevalence and timing with bipolar atrial leads. Pacing Clin Electrophysiol 2000;23:315-320.
    • (2000) Pacing Clin Electrophysiol , vol.23 , pp. 315-320
    • Brandt, J.1    Worzewski, W.2
  • 7
    • 3543114531 scopus 로고    scopus 로고
    • Preventricular far-field sensing in the atrial channel of dual chamber pacemakers - An occasional cause of inappropriate mode switch
    • Kolb C, Aratma S, Zrenner B, Schmitt C: Preventricular far-field sensing in the atrial channel of dual chamber pacemakers - An occasional cause of inappropriate mode switch. J Interv Card Electrophysiol 2004;10:231-235.
    • (2004) J Interv Card Electrophysiol , vol.10 , pp. 231-235
    • Kolb, C.1    Aratma, S.2    Zrenner, B.3    Schmitt, C.4
  • 9
    • 0034888919 scopus 로고    scopus 로고
    • Far-field R wave oversensing in a dual chamber arrhythmia management device: Predisposing factors and practical implications
    • Weretka S, Becker R, Hilbel T, Karle C, Osswald BR, Kübler W, Schöls W: Far-field R wave oversensing in a dual chamber arrhythmia management device: Predisposing factors and practical implications. Pacing Clin Electrophysiol 2001;24:1240-1246.
    • (2001) Pacing Clin Electrophysiol , vol.24 , pp. 1240-1246
    • Weretka, S.1    Becker, R.2    Hilbel, T.3    Karle, C.4    Osswald, B.R.5    Kübler, W.6    Schöls, W.7
  • 13
    • 0031951020 scopus 로고    scopus 로고
    • Prevalence of supraventricular arrhythmias from the automated analysis of data stored in the DDD pacemakers of 617 patients: The AIDA study
    • Defaye P, Dournaux F, Mouton E, for the AIDA multicenter study group: Prevalence of supraventricular arrhythmias from the automated analysis of data stored in the DDD pacemakers of 617 patients: The AIDA study. Pacing Clin Electrophysiol 1998;21:250-255.
    • (1998) Pacing Clin Electrophysiol , vol.21 , pp. 250-255
    • Defaye, P.1    Dournaux, F.2    Mouton, E.3
  • 17
    • 0033911655 scopus 로고    scopus 로고
    • Sensing of atrial fibrillation by a dual chamber pacemaker: How should atrial sensing be programmed to ensure adequate mode shifting?
    • Walfriedsson H, Aunes M, Capocci M, Edvardsson N: Sensing of atrial fibrillation by a dual chamber pacemaker: How should atrial sensing be programmed to ensure adequate mode shifting? Pacing Clin Electrophysiol 2000;23:1089-1093.
    • (2000) Pacing Clin Electrophysiol , vol.23 , pp. 1089-1093
    • Walfriedsson, H.1    Aunes, M.2    Capocci, M.3    Edvardsson, N.4
  • 18
    • 33747235434 scopus 로고    scopus 로고
    • Can far field R-wave sensing at follow-up be prevented by using acute threshold measurements?
    • Abstract
    • Cools FJC, van Twembecke R, Verpooten GA: Can far field R-wave sensing at follow-up be prevented by using acute threshold measurements? Europace 2003;4:B33 (Abstract).
    • (2003) Europace , vol.4
    • Cools, F.J.C.1    Van Twembecke, R.2    Verpooten, G.A.3
  • 21
    • 0037251638 scopus 로고    scopus 로고
    • Mode switching failure during atrial flutter: The '2:1 lock-in' phenomenon
    • Goethals M, Timmermans W, Geelen P, Backers J, Brugada P: Mode switching failure during atrial flutter: The '2:1 lock-in' phenomenon. Europace 2003;5:95-102.
    • (2003) Europace , vol.5 , pp. 95-102
    • Goethals, M.1    Timmermans, W.2    Geelen, P.3    Backers, J.4    Brugada, P.5
  • 22
    • 0036693688 scopus 로고    scopus 로고
    • Failure of atrial flutter detection by a pacemaker with a dedicated atrial flutter detection algorithm
    • Israel CW, Barold SS: Failure of atrial flutter detection by a pacemaker with a dedicated atrial flutter detection algorithm. Pacing Clin Electrophysiol 2002;25:1274-1277.
    • (2002) Pacing Clin Electrophysiol , vol.25 , pp. 1274-1277
    • Israel, C.W.1    Barold, S.S.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.