Far-field QRS complex sensing: Prevalence and timing with bipolar atrial leads

Author keywords

Atrial pacemaker lead; Dual chamber pacing; Oversensing; QRS complex sensing

Indexed keywords

AGED; ARTICLE; ARTIFICIAL HEART PACEMAKER; CLINICAL ARTICLE; FEMALE; HEART ATRIUM CONDUCTION; HEART ATRIUM PACEMAKER; HEART ATRIUM PACING; HUMAN; MALE; P WAVE; PREVALENCE; PULSE GENERATOR; QRS COMPLEX;

EID: 0034021440     PISSN: 01478389     EISSN: None     Source Type: Journal    
DOI: 10.1111/j.1540-8159.2000.tb06755.x     Document Type: Article
Times cited : (46)

References (16)
  • 1
    • 0015957775 scopus 로고
    • Permanent pervenons atrial pacing from the coronary vein. Long-term follow-up
    • 1. Moss AJ, Rivers RJ Jr, Kramer DH. Permanent pervenons atrial pacing from the coronary vein. Long-term follow-up. Circulation 1974; 49:222-225.
    • (1974) Circulation , vol.49 , pp. 222-225
    • Moss, A.J.1    Rivers R.J., Jr.2    Kramer, D.H.3
  • 2
    • 0021186817 scopus 로고
    • The effect of electrode position on atrial sensing for physiologically responsive cardiac pacemakers
    • 2. Timmis GC, Westveer DC, Gadowski G, et al. The effect of electrode position on atrial sensing for physiologically responsive cardiac pacemakers. Am Heart J 1984; 108:909-916.
    • (1984) Am Heart J , vol.108 , pp. 909-916
    • Timmis, G.C.1    Westveer, D.C.2    Gadowski, G.3
  • 3
    • 84994947840 scopus 로고
    • QRS-sensing via atrial lead in AAI and DDD pacing
    • 3. Schüller H, Brandt J, Fåhraeus T. QRS-sensing via atrial lead in AAI and DDD pacing. (abstract) PACE 1985; 8:A95.
    • (1985) PACE , vol.8
    • Schüller, H.1    Brandt, J.2    Fåhraeus, T.3
  • 4
    • 0023736984 scopus 로고
    • Far-field QRS complex sensing via the atrial pacemaker lead. I. Mechanism, consequences, differential diagnosis and countermeasures in AAI and VDD/DDD pacing
    • 4. Brandt J, Fåhraeus T, Schüller H. Far-field QRS complex sensing via the atrial pacemaker lead. I. Mechanism, consequences, differential diagnosis and countermeasures in AAI and VDD/DDD pacing. PACE 1988; 11:1432-1438.
    • (1988) PACE , vol.11 , pp. 1432-1438
    • Brandt, J.1    Fåhraeus, T.2    Schüller, H.3
  • 5
    • 0024274730 scopus 로고
    • Far-field QRS complex sensing via the atrial pacemaker lead. II. Prevalence, clinical significance and possibility of intraoperative prediction in DDD pacing
    • 5. Brandt J, Fåhraeus T, Schüller H. Far-field QRS complex sensing via the atrial pacemaker lead. II. Prevalence, clinical significance and possibility of intraoperative prediction in DDD pacing. PACE 1988; 11:1540-1544.
    • (1988) PACE , vol.11 , pp. 1540-1544
    • Brandt, J.1    Fåhraeus, T.2    Schüller, H.3
  • 6
    • 0020695945 scopus 로고
    • Sensing characteristics of the right atrial appendage electrode
    • 6. Griffin JC. Sensing characteristics of the right atrial appendage electrode. PACE 1983; 6:22-25.
    • (1983) PACE , vol.6 , pp. 22-25
    • Griffin, J.C.1
  • 7
    • 0029958324 scopus 로고    scopus 로고
    • Effect of varying atrial sensitivity, AV interval, and detection algorithm on automatic mode switching
    • 7. Palma EC, Kedarnath V, Vankawalla V, et al. Effect of varying atrial sensitivity, AV interval, and detection algorithm on automatic mode switching. PACE 1996; 19(Pt.II):1734-1739.
    • (1996) PACE , vol.19 , Issue.PT.II , pp. 1734-1739
    • Palma, E.C.1    Kedarnath, V.2    Vankawalla, V.3
  • 8
    • 0031818491 scopus 로고    scopus 로고
    • Electrical proarrhythmia: Induction of inappropriate atrial therapies due to far-field R wave oversensing in a new dual chamber defibrillator
    • 8. Wolpert C, Jung W, Scholl C, et al. Electrical proarrhythmia: Induction of inappropriate atrial therapies due to far-field R wave oversensing in a new dual chamber defibrillator. J Cardiovasc Electrophysiol 1998; 9:859-863.
    • (1998) J Cardiovasc Electrophysiol , vol.9 , pp. 859-863
    • Wolpert, C.1    Jung, W.2    Scholl, C.3
  • 9
    • 0030907244 scopus 로고    scopus 로고
    • Analysis of atrial sensed far-field ventricular signals: A reassessment
    • 9. Brouwer J, Nagelkerke D, den Heijer P, et al. Analysis of atrial sensed far-field ventricular signals: A reassessment. PACE 1997; 20:916-922.
    • (1997) PACE , vol.20 , pp. 916-922
    • Brouwer, J.1    Nagelkerke, D.2    Den Heijer, P.3
  • 10
    • 0001509975 scopus 로고    scopus 로고
    • Atrial lead position: The effect on measured farfield ventricular signals
    • 10. Okreglicki A, Kim CH, Akiyama T, et al. Atrial lead position: The effect on measured farfield ventricular signals. (abstract) PACE 1999; 21:876.
    • (1999) PACE , vol.21 , pp. 876
    • Okreglicki, A.1    Kim, C.H.2    Akiyama, T.3
  • 11
    • 0000057243 scopus 로고    scopus 로고
    • Bipolar ventricular far field sensing in the atrium: Any impact of lead position (septum versus free wall) or tip to ring spacing (10 versus 30 mm)?
    • 11. Fröhlig G, Berg M, Kusch O, et al. Bipolar ventricular far field sensing in the atrium: Any impact of lead position (septum versus free wall) or tip to ring spacing (10 versus 30 mm)? (abstract) PACE 1999; 22:876.
    • (1999) PACE , vol.22 , pp. 876
    • Fröhlig, G.1    Berg, M.2    Kusch, O.3
  • 12
    • 0000522111 scopus 로고    scopus 로고
    • Interelectrode spacing and right atrial location, both influence far-field ventricular electrogram amplitude
    • 12. Adler SW, Brown ML, Nelson LK, et al. Interelectrode spacing and right atrial location, both influence far-field ventricular electrogram amplitude. (abstract) PACE 1999; 22:877.
    • (1999) PACE , vol.22 , pp. 877
    • Adler, S.W.1    Brown, M.L.2    Nelson, L.K.3
  • 13
    • 0030877125 scopus 로고    scopus 로고
    • Is mode switching beneficial? A randomized study in patients with paroxysmal atrial tachyarrhythmias
    • 13. Kamalvand K, Tan K, Kotsakis A, et al. Is mode switching beneficial? A randomized study in patients with paroxysmal atrial tachyarrhythmias. J Am Coll Cardiol 1997; 30:496-504.
    • (1997) J Am Coll Cardiol , vol.30 , pp. 496-504
    • Kamalvand, K.1    Tan, K.2    Kotsakis, A.3
  • 14
    • 0020674570 scopus 로고
    • Atrio-ventricular and ventriculo-atrial conduction times in patients undergoing pacemaker implant
    • 14. Hayes DL, Furman S. Atrio-ventricular and ventriculo-atrial conduction times in patients undergoing pacemaker implant. PACE 1983; 6:38-46.
    • (1983) PACE , vol.6 , pp. 38-46
    • Hayes, D.L.1    Furman, S.2
  • 15
    • 0021216274 scopus 로고
    • Prevalence and significance of ventriculo-atrial conduction
    • 15. Westveer DC, Stewart JR, Goodfleish R, et al. Prevalence and significance of ventriculo-atrial conduction. PACE 1984; 7:784-789.
    • (1984) PACE , vol.7 , pp. 784-789
    • Westveer, D.C.1    Stewart, J.R.2    Goodfleish, R.3
  • 16
    • 0025611355 scopus 로고
    • Dynamic electrophysiology of ventriculoatrial conduction: Implications for DDD and DDDR pacing
    • 16. Cazeau S, Daubert C, Mabo P, et al. Dynamic electrophysiology of ventriculoatrial conduction: Implications for DDD and DDDR pacing. PACE 1990; 13:1646-1655.
    • (1990) PACE , vol.13 , pp. 1646-1655
    • Cazeau, S.1    Daubert, C.2    Mabo, P.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.