Permanent pervenons atrial pacing from the coronary vein. Long-term follow-up
-
1. Moss AJ, Rivers RJ Jr, Kramer DH. Permanent pervenons atrial pacing from the coronary vein. Long-term follow-up. Circulation 1974; 49:222-225.
-
(1974)
Circulation
, vol.49
, pp. 222-225
-
-
Moss, A.J.1
Rivers R.J., Jr.2
Kramer, D.H.3
-
2
-
-
0021186817
-
The effect of electrode position on atrial sensing for physiologically responsive cardiac pacemakers
-
2. Timmis GC, Westveer DC, Gadowski G, et al. The effect of electrode position on atrial sensing for physiologically responsive cardiac pacemakers. Am Heart J 1984; 108:909-916.
-
(1984)
Am Heart J
, vol.108
, pp. 909-916
-
-
Timmis, G.C.1
Westveer, D.C.2
Gadowski, G.3
-
3
-
-
84994947840
-
QRS-sensing via atrial lead in AAI and DDD pacing
-
3. Schüller H, Brandt J, Fåhraeus T. QRS-sensing via atrial lead in AAI and DDD pacing. (abstract) PACE 1985; 8:A95.
-
(1985)
PACE
, vol.8
-
-
Schüller, H.1
Brandt, J.2
Fåhraeus, T.3
-
4
-
-
0023736984
-
Far-field QRS complex sensing via the atrial pacemaker lead. I. Mechanism, consequences, differential diagnosis and countermeasures in AAI and VDD/DDD pacing
-
4. Brandt J, Fåhraeus T, Schüller H. Far-field QRS complex sensing via the atrial pacemaker lead. I. Mechanism, consequences, differential diagnosis and countermeasures in AAI and VDD/DDD pacing. PACE 1988; 11:1432-1438.
-
(1988)
PACE
, vol.11
, pp. 1432-1438
-
-
Brandt, J.1
Fåhraeus, T.2
Schüller, H.3
-
5
-
-
0024274730
-
Far-field QRS complex sensing via the atrial pacemaker lead. II. Prevalence, clinical significance and possibility of intraoperative prediction in DDD pacing
-
5. Brandt J, Fåhraeus T, Schüller H. Far-field QRS complex sensing via the atrial pacemaker lead. II. Prevalence, clinical significance and possibility of intraoperative prediction in DDD pacing. PACE 1988; 11:1540-1544.
-
(1988)
PACE
, vol.11
, pp. 1540-1544
-
-
Brandt, J.1
Fåhraeus, T.2
Schüller, H.3
-
6
-
-
0020695945
-
Sensing characteristics of the right atrial appendage electrode
-
6. Griffin JC. Sensing characteristics of the right atrial appendage electrode. PACE 1983; 6:22-25.
-
(1983)
PACE
, vol.6
, pp. 22-25
-
-
Griffin, J.C.1
-
7
-
-
0029958324
-
Effect of varying atrial sensitivity, AV interval, and detection algorithm on automatic mode switching
-
7. Palma EC, Kedarnath V, Vankawalla V, et al. Effect of varying atrial sensitivity, AV interval, and detection algorithm on automatic mode switching. PACE 1996; 19(Pt.II):1734-1739.
-
(1996)
PACE
, vol.19
, Issue.PT.II
, pp. 1734-1739
-
-
Palma, E.C.1
Kedarnath, V.2
Vankawalla, V.3
-
8
-
-
0031818491
-
Electrical proarrhythmia: Induction of inappropriate atrial therapies due to far-field R wave oversensing in a new dual chamber defibrillator
-
8. Wolpert C, Jung W, Scholl C, et al. Electrical proarrhythmia: Induction of inappropriate atrial therapies due to far-field R wave oversensing in a new dual chamber defibrillator. J Cardiovasc Electrophysiol 1998; 9:859-863.
-
(1998)
J Cardiovasc Electrophysiol
, vol.9
, pp. 859-863
-
-
Wolpert, C.1
Jung, W.2
Scholl, C.3
-
9
-
-
0030907244
-
Analysis of atrial sensed far-field ventricular signals: A reassessment
-
9. Brouwer J, Nagelkerke D, den Heijer P, et al. Analysis of atrial sensed far-field ventricular signals: A reassessment. PACE 1997; 20:916-922.
-
(1997)
PACE
, vol.20
, pp. 916-922
-
-
Brouwer, J.1
Nagelkerke, D.2
Den Heijer, P.3
-
10
-
-
0001509975
-
Atrial lead position: The effect on measured farfield ventricular signals
-
10. Okreglicki A, Kim CH, Akiyama T, et al. Atrial lead position: The effect on measured farfield ventricular signals. (abstract) PACE 1999; 21:876.
-
(1999)
PACE
, vol.21
, pp. 876
-
-
Okreglicki, A.1
Kim, C.H.2
Akiyama, T.3
-
11
-
-
0000057243
-
Bipolar ventricular far field sensing in the atrium: Any impact of lead position (septum versus free wall) or tip to ring spacing (10 versus 30 mm)?
-
11. Fröhlig G, Berg M, Kusch O, et al. Bipolar ventricular far field sensing in the atrium: Any impact of lead position (septum versus free wall) or tip to ring spacing (10 versus 30 mm)? (abstract) PACE 1999; 22:876.
-
(1999)
PACE
, vol.22
, pp. 876
-
-
Fröhlig, G.1
Berg, M.2
Kusch, O.3
-
12
-
-
0000522111
-
Interelectrode spacing and right atrial location, both influence far-field ventricular electrogram amplitude
-
12. Adler SW, Brown ML, Nelson LK, et al. Interelectrode spacing and right atrial location, both influence far-field ventricular electrogram amplitude. (abstract) PACE 1999; 22:877.
-
(1999)
PACE
, vol.22
, pp. 877
-
-
Adler, S.W.1
Brown, M.L.2
Nelson, L.K.3
-
13
-
-
0030877125
-
Is mode switching beneficial? A randomized study in patients with paroxysmal atrial tachyarrhythmias
-
13. Kamalvand K, Tan K, Kotsakis A, et al. Is mode switching beneficial? A randomized study in patients with paroxysmal atrial tachyarrhythmias. J Am Coll Cardiol 1997; 30:496-504.
-
(1997)
J Am Coll Cardiol
, vol.30
, pp. 496-504
-
-
Kamalvand, K.1
Tan, K.2
Kotsakis, A.3
-
14
-
-
0020674570
-
Atrio-ventricular and ventriculo-atrial conduction times in patients undergoing pacemaker implant
-
14. Hayes DL, Furman S. Atrio-ventricular and ventriculo-atrial conduction times in patients undergoing pacemaker implant. PACE 1983; 6:38-46.
-
(1983)
PACE
, vol.6
, pp. 38-46
-
-
Hayes, D.L.1
Furman, S.2
-
15
-
-
0021216274
-
Prevalence and significance of ventriculo-atrial conduction
-
15. Westveer DC, Stewart JR, Goodfleish R, et al. Prevalence and significance of ventriculo-atrial conduction. PACE 1984; 7:784-789.
-
(1984)
PACE
, vol.7
, pp. 784-789
-
-
Westveer, D.C.1
Stewart, J.R.2
Goodfleish, R.3
-
16
-
-
0025611355
-
Dynamic electrophysiology of ventriculoatrial conduction: Implications for DDD and DDDR pacing
-
16. Cazeau S, Daubert C, Mabo P, et al. Dynamic electrophysiology of ventriculoatrial conduction: Implications for DDD and DDDR pacing. PACE 1990; 13:1646-1655.
-
(1990)
PACE
, vol.13
, pp. 1646-1655
-
-
Cazeau, S.1
Daubert, C.2
Mabo, P.3
|