Volumn 10, Issue 3, 2004, Pages 231-235

Preventricular far-field sensing in the atrial channel of dual chamber pacemakers - An occasional cause of inappropriate mode switch

Author keywords

Far field sensing; Mode switch; Oversensing; Pacemaker diagnostics

Indexed keywords

ARTICLE; ATRIOVENTRICULAR CONDUCTION; DIFFERENTIAL DIAGNOSIS; HEART ATRIUM; HEART ATRIUM PACEMAKER; HEART MUSCLE CONDUCTION DISTURBANCE; HEART MUSCLE POTENTIAL; HEART VENTRICLE; HUMAN; IMPLANT; P WAVE; PHYSICAL SENSITIVITY; PRIORITY JOURNAL; R WAVE; SINUS RHYTHM; SUPRAVENTRICULAR TACHYCARDIA;

EID: 3543114531     PISSN: 1383875X     EISSN: None     Source Type: Journal    
DOI: 10.1023/B:JICE.0000026917.82516.eb     Document Type: Article
Times cited : (16)

References (10)
  • 5
    • 0034888919 scopus 로고    scopus 로고
    • Far-field R wave oversensing in a dual chamber arrhythmia management device: Predisposing factors and practical implications
    • Weretka S, Becker R, Hilbel T, Karle C, Osswald BR, Kübler W, Schöls W. Far-field R wave oversensing in a dual chamber arrhythmia management device: Predisposing factors and practical implications. Pacing Clin Electrophysiol 2001;24:1240-1246.
    • (2001) Pacing Clin Electrophysiol , vol.24 , pp. 1240-1246
    • Weretka, S.1    Becker, R.2    Hilbel, T.3    Karle, C.4    Osswald, B.R.5    Kübler, W.6    Schöls, W.7
  • 6
    • 0033927352 scopus 로고    scopus 로고
    • High rate atrial tachyarrhythmia detections in implantable pulse generators: Low incidence of false-positive detections
    • 3 Clinical Trial Investigators. High rate atrial tachyarrhythmia detections in implantable pulse generators: Low incidence of false-positive detections. Pacing Clin Electrophysiol 2000;23:1080-1086.
    • (2000) Pacing Clin Electrophysiol , vol.23 , pp. 1080-1086
    • Fitts, S.M.1    Hill, M.R.S.2    Mehra, R.3    Gillis, A.M.4
  • 8
    • 0034021440 scopus 로고    scopus 로고
    • Far-field QRS complex sensing: Prevalence and timing with bipolar atrial leads
    • Brandt J, Worzewski W. Far-field QRS complex sensing: Prevalence and timing with bipolar atrial leads. Pacing Clin Electrophysiol 2000;23:315-320.
    • (2000) Pacing Clin Electrophysiol , vol.23 , pp. 315-320
    • Brandt, J.1    Worzewski, W.2
  • 9
    • 0033911655 scopus 로고    scopus 로고
    • Sensing of atrial fibrillation by a dual chamber pacemaker: How should atrial sensing be programmed to ensure adequate mode shifting?
    • Walfriedsson H, Aunes M, Capocci M, Edvardsson N. Sensing of atrial fibrillation by a dual chamber pacemaker: How should atrial sensing be programmed to ensure adequate mode shifting? Pacing Clin Electrophysiol 2000;23:1089-1093.
    • (2000) Pacing Clin Electrophysiol , vol.23 , pp. 1089-1093
    • Walfriedsson, H.1    Aunes, M.2    Capocci, M.3    Edvardsson, N.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.