Mode switching failure during atrial flutter: The '2:1 lock-in' phenomenon

Author keywords

Atrial flutter; Dual chamber pacemakers; Mode switching failure

Indexed keywords

ANTIARRHYTHMIC AGENT;

EID: 0037251638     PISSN: 10995129     EISSN: None     Source Type: Journal    
DOI: 10.1053/eupc.2002.0281     Document Type: Article
Times cited : (26)

References (13)
  • 1
    • 0028111092 scopus 로고
    • Fallback response of dual chamber (DDD and DDDR) pacemakers: A proposed classification
    • Barold SS, Mond HG. Fallback response of dual chamber (DDD and DDDR) pacemakers: a proposed classification. Pacing Clin Electrophysiol 1994; 17: 1160-5.
    • (1994) Pacing Clin. Electrophysiol. , vol.17 , pp. 1160-1165
    • Barold, S.S.1    Mond, H.G.2
  • 2
  • 4
    • 0029958324 scopus 로고    scopus 로고
    • Effect of varying atrial sensitivity, AV interval, and detection algorithm on automatic mode switching
    • Palma EC, Kedarnath V, Vankawalla V, et al. Effect of varying atrial sensitivity, AV interval, and detection algorithm on automatic mode switching. Pacing Clin Electrophysiol 1996; 19: 1734-9.
    • (1996) Pacing Clin. Electrophysiol. , vol.19 , pp. 1734-1739
    • Palma, E.C.1    Kedarnath, V.2    Vankawalla, V.3
  • 5
    • 0000340954 scopus 로고    scopus 로고
    • Is automatic mode switching effective for atrial arrhythmias occurring at different rates? A study of the efficacy of automatic mode and rate switching to simulated atrial arrhythmias by chest wall stimulation
    • Leung SK, Lau CP, Tse-Fun Lam C, et al. Is automatic mode switching effective for atrial arrhythmias occurring at different rates? A study of the efficacy of automatic mode and rate switching to simulated atrial arrhythmias by chest wall stimulation. Pacing Clin Electrophysiol 2000; 23: 824-31.
    • (2000) Pacing Clin. Electrophysiol. , vol.23 , pp. 824-831
    • Leung, S.K.1    Lau, C.P.2    Tse-Fun Lam, C.3
  • 6
    • 0029003741 scopus 로고
    • Inconsistent response to rapid atrial rhythms in a DDD pacemaker with the fallback feature
    • Johnson NJ. Inconsistent response to rapid atrial rhythms in a DDD pacemaker with the fallback feature. Pacing Clin Electrophysiol 1995; 18: 1458-62.
    • (1995) Pacing Clin. Electrophysiol. , vol.18 , pp. 1458-1462
    • Johnson, N.J.1
  • 7
    • 0036220937 scopus 로고    scopus 로고
    • Analysis of mode switching algorithms in dual chamber pacemakers
    • Israel CW. Analysis of mode switching algorithms in dual chamber pacemakers. Pacing Clin Electrophysiol 2002; 25: 380-93.
    • (2002) Pacing Clin. Electrophysiol. , vol.25 , pp. 380-393
    • Israel, C.W.1
  • 8
    • 0024274730 scopus 로고
    • Far-field QRS complex sensing via the atrial pacemaker lead. II. Prevalence, clinical significance and possibility of intraoperative prediction in DDD pacing
    • Brandt J, Fåhraeus T, Schüller H. Far-field QRS complex sensing via the atrial pacemaker lead. II. Prevalence, clinical significance and possibility of intraoperative prediction in DDD pacing. Pacing Clin Electrophysiol 1988; 11: 1540-4.
    • (1988) Pacing Clin. Electrophysiol. , vol.11 , pp. 1540-1544
    • Brandt, J.1    Fåhraeus, T.2    Schüller, H.3
  • 10
    • 0034021440 scopus 로고    scopus 로고
    • Far-field QRS complex sensing: Prevalence and timing with bipolar atrial sensing atrial leads
    • Brandt J, Worzewski W. Far-field QRS complex sensing: prevalence and timing with bipolar atrial sensing atrial leads. Pacing Clin Electrophysiol 2000; 23: 315-20.
    • (2000) Pacing Clin. Electrophysiol. , vol.23 , pp. 315-320
    • Brandt, J.1    Worzewski, W.2
  • 11
    • 12244258715 scopus 로고    scopus 로고
    • Far-field R wave sensing
    • Lazarus A. Far-field R wave sensing. Prog Biomed Res 1998; 4: 229-31.
    • (1998) Prog. Biomed Res. , vol.4 , pp. 229-231
    • Lazarus, A.1
  • 12
    • 0002383879 scopus 로고    scopus 로고
    • Feasibility of using atrial sensitivities below 0.5 mV in a DDD(R) pacemaker with mode switching algorithm
    • Cools F, Van Twembeke R, Hemelhof H, et al. Feasibility of using atrial sensitivities below 0.5 mV in a DDD(R) pacemaker with mode switching algorithm. Prog Biomed Res 1999; 3: 303-6.
    • (1999) Prog. Biomed. Res. , vol.3 , pp. 303-306
    • Cools, F.1    Van Twembeke, R.2    Hemelhof, H.3
  • 13
    • 0033008422 scopus 로고    scopus 로고
    • Tiered management of atrial arrhythmias: The Pulsar Max™ family of pacemakers
    • Sutton R, Stack Z, Bruls A, et al. Tiered management of atrial arrhythmias: The Pulsar Max™ family of pacemakers. Herzschr Elektrophys 1999; 1O(Suppl. 1): 1/8-1/14.
    • (1999) Herzschr Elektrophys. , vol.10 , Issue.SUPPL. 1
    • Sutton, R.1    Stack, Z.2    Bruls, A.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.