메뉴 건너뛰기




Volumn 14, Issue 4, 2003, Pages 437-443

Early detection of implant healing process using resonance frequency analysis

Author keywords

Biomechanics; Dental implant; Osseointegration; Resonance frequency

Indexed keywords

ANIMAL EXPERIMENT; ANIMAL MODEL; ANIMAL TISSUE; ARTICLE; CONTROLLED STUDY; FREQUENCY ANALYSIS; IMPLANTATION; IN VITRO STUDY; IN VIVO STUDY; NONHUMAN; RABBIT; SIMULATION; STATISTICAL SIGNIFICANCE; SURGICAL TECHNIQUE; WOUND HEALING; ACOUSTICS; ANALYSIS OF VARIANCE; ANIMAL; BONE REGENERATION; COMPARATIVE STUDY; INSTRUMENTATION; MALE; PATHOPHYSIOLOGY; PHYSIOLOGY; REPRODUCIBILITY; SIGNAL PROCESSING; SURFACE PROPERTY; TIBIA; TIME; TOOTH IMPLANTATION; VALIDATION STUDY; VIBRATION;

EID: 0141497384     PISSN: 09057161     EISSN: None     Source Type: Journal    
DOI: 10.1034/j.1600-0501.2003.00818.x     Document Type: Article
Times cited : (101)

References (30)
  • 3
    • 0031132982 scopus 로고    scopus 로고
    • The relationship of some histologic parameters, radiographic evaluations, and Periotest measurements of oral implants: An experimental animal study
    • Caulier, H., Naert, I., Kalk, W. & Jansen, J.A. (1997) The relationship of some histologic parameters, radiographic evaluations, and Periotest measurements of oral implants: an experimental animal study. International Journal of Oral and Maxillofacial Implants 3: 380-386.
    • (1997) International Journal of Oral and Maxillofacial Implants , vol.3 , pp. 380-386
    • Caulier, H.1    Naert, I.2    Kalk, W.3    Jansen, J.A.4
  • 7
    • 0028686291 scopus 로고
    • A histomorphometric evaluation of bone-to-implant contact on machine-prepared and roughened titanium dental implants. A pilot study in the dog
    • Ericsson, I., Johansson, C.B., Bystedt, H. & Norton, M.R. (1994) A histomorphometric evaluation of bone-to-implant contact on machine-prepared and roughened titanium dental implants. A pilot study in the dog. Clinical Oral Implants Research 5: 202-206.
    • (1994) Clinical Oral Implants Research , vol.5 , pp. 202-206
    • Ericsson, I.1    Johansson, C.B.2    Bystedt, H.3    Norton, M.R.4
  • 8
    • 0029440426 scopus 로고
    • Identification of bone quality in conjunction with insertion of titanium implant. A pilot study in jaw autopsy specimens
    • Friberg, B., Sennerby, L., Roos, J. & Lekholm, U. (1995) Identification of bone quality in conjunction with insertion of titanium implant. A pilot study in jaw autopsy specimens. Clinical Oral Implants Research 6: 213-219.
    • (1995) Clinical Oral Implants Research , vol.6 , pp. 213-219
    • Friberg, B.1    Sennerby, L.2    Roos, J.3    Lekholm, U.4
  • 9
    • 0033176199 scopus 로고    scopus 로고
    • A comparison between cutting torque and resonance frequency measurements of maxillary implants. A 20-month clinical study
    • Friberg, B., Sennerby, L., Meredith, N. & Lekholm, U. (1999) A comparison between cutting torque and resonance frequency measurements of maxillary implants. A 20-month clinical study. International Journal of Oral Maxillofacial Surgery 28: 297-303.
    • (1999) International Journal of Oral Maxillofacial Surgery , vol.28 , pp. 297-303
    • Friberg, B.1    Sennerby, L.2    Meredith, N.3    Lekholm, U.4
  • 10
    • 0036481346 scopus 로고    scopus 로고
    • Resonance frequency assessment of dental implant stability with various bone qualities: A numerical approach
    • Huang, H.M., Lee, S.Y., Yeh, C.Y. & Lin, C.T. (2002) Resonance frequency assessment of dental implant stability with various bone qualities: a numerical approach. Clinical Oral Implant Research 13: 65-74.
    • (2002) Clinical Oral Implant Research , vol.13 , pp. 65-74
    • Huang, H.M.1    Lee, S.Y.2    Yeh, C.Y.3    Lin, C.T.4
  • 13
    • 0026301882 scopus 로고
    • A removal torque and histomorphometric study of bone tissue reactions to commercially pure titanium and vitallium implants
    • Johansson, C.B., Sennerby, L. & Albrektsson, T. (1991) A removal torque and histomorphometric study of bone tissue reactions to commercially pure titanium and vitallium implants. International Journal of Oral amp; Maxillofacial Implants 6: 437-441.
    • (1991) International Journal of Oral amp; Maxillofacial Implants , vol.6 , pp. 437-441
    • Johansson, C.B.1    Sennerby, L.2    Albrektsson, T.3
  • 14
    • 0034168143 scopus 로고    scopus 로고
    • In vivo and in vitro natural frequency analysis of periodontal conditions: An innovative method
    • Lee, S.Y., Huang, H.M., Lin, C.Y. & Shih, Y.H. (2000) In vivo and in vitro natural frequency analysis of periodontal conditions: an innovative method. Journal of Periodontology 71: 632-640.
    • (2000) Journal of Periodontology , vol.71 , pp. 632-640
    • Lee, S.Y.1    Huang, H.M.2    Lin, C.Y.3    Shih, Y.H.4
  • 15
    • 0032151752 scopus 로고    scopus 로고
    • Assessment of implant stability as a prognostic determinant
    • Meredith, N. (1998) Assessment of implant stability as a prognostic determinant. International Journal of Prosthodontics 11: 491-501.
    • (1998) International Journal of Prosthodontics , vol.11 , pp. 491-501
    • Meredith, N.1
  • 16
    • 0030224153 scopus 로고    scopus 로고
    • Quantitative determination of the stability of the implant-tissue interface using resonance frequency analysis
    • Meredith, N., Alleyne, D. & Cawley, P. (1996) Quantitative determination of the stability of the implant-tissue interface using resonance frequency analysis. Clinical Oral Implants Research 7: 261-267.
    • (1996) Clinical Oral Implants Research , vol.7 , pp. 261-267
    • Meredith, N.1    Alleyne, D.2    Cawley, P.3
  • 17
    • 0031152150 scopus 로고    scopus 로고
    • Resonance frequency measurements of implant stability in vivo. A cross-sectional and longitudinal study of resonance frequency measurements on implants in the edentulous and partially dentate maxilla
    • Meredith, N., Book, K., Friberg, B., Jemt, T. & Sennerby, L. (1997a) Resonance frequency measurements of implant stability in vivo. A cross-sectional and longitudinal study of resonance frequency measurements on implants in the edentulous and partially dentate maxilla. Clinical Oral Implants Research 8: 226-233.
    • (1997) Clinical Oral Implants Research , vol.8 , pp. 226-233
    • Meredith, N.1    Book, K.2    Friberg, B.3    Jemt, T.4    Sennerby, L.5
  • 18
    • 0031152189 scopus 로고    scopus 로고
    • The application of resonance frequency measurements to study the stability of titanium implants during healing in the rabbit tibia
    • Meredith, N., Shagaldi, F., Alleyne, D., Sennerby, L. & Cawley, P. (1997b) The application of resonance frequency measurements to study the stability of titanium implants during healing in the rabbit tibia. Clinical Oral Implants Research 8: 234-243.
    • (1997) Clinical Oral Implants Research , vol.8 , pp. 234-243
    • Meredith, N.1    Shagaldi, F.2    Alleyne, D.3    Sennerby, L.4    Cawley, P.5
  • 19
    • 0029681729 scopus 로고    scopus 로고
    • Assessment of fracture healing in the tibia using the impulse response method
    • Nakatsuchi, Y., Tsuchikane, A. & Nomura, A. (1996) Assessment of fracture healing in the tibia using the impulse response method. Journal of Orthopaedic Trauma 10: 50-62.
    • (1996) Journal of Orthopaedic Trauma , vol.10 , pp. 50-62
    • Nakatsuchi, Y.1    Tsuchikane, A.2    Nomura, A.3
  • 20
    • 0032605516 scopus 로고    scopus 로고
    • The use of low-frequency vibration measurement in orthopaedics
    • Nokes, L.D. (1999) The use of low-frequency vibration measurement in orthopaedics. Proceedings of the Institution of Mechanical Engineers 213 (H): 271-290.
    • (1999) Proceedings of the Institution of Mechanical Engineers , vol.213 , Issue.H , pp. 271-290
    • Nokes, L.D.1
  • 22
    • 0033145562 scopus 로고    scopus 로고
    • The influence of simultaneous versus delayed placement on the stability of titanium implants in onlay bone grafts: A histologic and biomechanics study in the rabbit
    • Rasmusson, L., Meredith, N., Cho, H.I., & Sennerby, L. (1999) The influence of simultaneous versus delayed placement on the stability of titanium implants in onlay bone grafts: a histologic and biomechanics study in the rabbit. International Journal of Oral and Maxillofacial Surgery 28: 224-231.
    • (1999) International Journal of Oral and Maxillofacial Surgery , vol.28 , pp. 224-231
    • Rasmusson, L.1    Meredith, N.2    Cho, H.I.3    Sennerby, L.4
  • 23
    • 0016707373 scopus 로고
    • The effect of movement on holding power of screws in bone
    • Schatzker, J., Home, J.G. & Sumner-Smith, G. (1975) The effect of movement on holding power of screws in bone. Clinical Orthopaedics 111: 257-262.
    • (1975) Clinical Orthopaedics , vol.111 , pp. 257-262
    • Schatzker, J.1    Home, J.G.2    Sumner-Smith, G.3
  • 24
    • 0026826756 scopus 로고
    • A morphometric and biomechanic comparison of titanium implants inserted in rabbit cortical and cancellous bone
    • Sennerby, L., Thomsen, P. & Ericson, L.E. (1992a) A morphometric and biomechanic comparison of titanium implants inserted in rabbit cortical and cancellous bone. International Journal of Oral and Maxillofacial Implants 7: 62-71.
    • (1992) International Journal of Oral and Maxillofacial Implants , vol.7 , pp. 62-71
    • Sennerby, L.1    Thomsen, P.2    Ericson, L.E.3
  • 26
    • 0026816665 scopus 로고
    • Finite element stress analysis of push-out test. Part 1: Fixed interface using stress compatible elements
    • Shirazi-Adl, A. (1992) Finite element stress analysis of push-out test. Part 1: Fixed interface using stress compatible elements. Journal of Biomechanical Engineering 114: 111-118.
    • (1992) Journal of Biomechanical Engineering , vol.114 , pp. 111-118
    • Shirazi-Adl, A.1
  • 29
    • 0015694102 scopus 로고
    • Mechanical factors influencing the holding powers of screws in compact bone
    • Uhthoff, H.K. (1973) Mechanical factors influencing the holding powers of screws in compact bone. Journal of Bone and Joint Surgery 55 (B): 633-639.
    • (1973) Journal of Bone and Joint Surgery , vol.55 , Issue.B , pp. 633-639
    • Uhthoff, H.K.1
  • 30
    • 0029268053 scopus 로고
    • A histomorphometric and removal torque study of screw-shaped titanium implants with three different surface topographies
    • Wennerberg, A., Albrektsson, T., Andersson, B. & Krol, J.J. (1995) A histomorphometric and removal torque study of screw-shaped titanium implants with three different surface topographies. Clinical Oral Implants Research 6: 24-30.
    • (1995) Clinical Oral Implants Research , vol.6 , pp. 24-30
    • Wennerberg, A.1    Albrektsson, T.2    Andersson, B.3    Krol, J.J.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.