메뉴 건너뛰기




Volumn 8, Issue 4, 2006, Pages 505-512

Further development of a robust workup process for solution-phase high-throughput library synthesis to address environmental and sample tracking issues

Author keywords

[No Author keywords available]

Indexed keywords

AMIDE; POLYSORBATE; SOLVENT; SURFACTANT; VALERIC ACID DERIVATIVE;

EID: 33746352366     PISSN: 15204766     EISSN: None     Source Type: Journal    
DOI: 10.1021/cc060004l     Document Type: Article
Times cited : (10)

References (27)
  • 7
    • 0003783790 scopus 로고
    • (b) Sugawara, T. Pharmacia 1995, 31, 1159-1162.
    • (1995) Pharmacia , vol.31 , pp. 1159-1162
    • Sugawara, T.1
  • 13
    • 33746348140 scopus 로고    scopus 로고
    • note
    • Modular high-throughput apparatuses include Myriad Core System, Myriad Personal Synthesizer (Mettler Toledo, Japan), Genesis multichannel liquid handler (Tecan, Manndorf, Switzerland), centrifugal evaporator (Genevac, Ipswich, U.K.), preparative HPLC purification system (Gilson, Wisconsin, U.S.A.), LC/Mass instruments (Shimadzu, Kyoto, Japan and Waters, Massachusetts, U.S.A.), and Automated weigher (Mettler Toledo, U.S.A.).
  • 14
    • 33746361644 scopus 로고    scopus 로고
    • note
    • Restriction limits are included in the Japanese laws. See Industrial Safety and Health law, law 57, article 28, clause 3; Air pollution control law, law 32, article 18, clause 21; and Clean Water law, law 35, article 3, clause 1.
  • 15
    • 33746326623 scopus 로고    scopus 로고
    • note
    • The stirring rack to contain the reaction vessels and the filter rack to hold phase separation tubes and the Exchanger 96 to transfer the vials from the polypropylene rack to the aluminum rack were all custom-made by Unitech Ltd. (Unitech, Osaka, Japan).
  • 16
    • 3042661383 scopus 로고    scopus 로고
    • Workstations and systems
    • Cork, D. G., Sugawara, T., Eds.; Marcel Dekker Inc.: New York
    • Hird, N.; MacLachlan, W. Robotic Workstations and Systems. In Laboratory Automation in the Chemical Industries; Cork, D. G., Sugawara, T., Eds.; Marcel Dekker Inc.: New York, 2002; pp 1-39.
    • (2002) Laboratory Automation in the Chemical Industries , pp. 1-39
    • Hird, N.1    Robotic, M.W.2
  • 17
    • 33746324081 scopus 로고    scopus 로고
    • note
    • Filter tubes (Catalogue No. 6984-0610, 1.0 μm) sold by Whatman Inc., Clifton, NJ. http://www.whatman.com (accessed 09/06/05).
  • 18
    • 33746383611 scopus 로고    scopus 로고
    • PCT Japanese Patent No. 15238, 2003
    • The top-phase filter tube was developed in collaboration with Wako Pure Chemical Industries Ltd. (Osaka, Japan), who now sell the tube as PreSep. Cork, D. G.; Inoue, K. PCT Japanese Patent No. 15238, 2003.
    • Cork, D.G.1    Inoue, K.2
  • 19
    • 33746369592 scopus 로고    scopus 로고
    • note
    • Traces of DMF or other organic compounds in the aqueous phase may cause the aqueous phase to also gradually seep through the PTFE membranes. The vials containing the organic phase should, therefore, be removed for further processing soon after filtration is observed to stop.
  • 20
    • 33746375502 scopus 로고    scopus 로고
    • PCT Japanese Patent Nos. 113927A, 2004; 004317, 2004; 131504A, 2005
    • The Soltrapper customized apparatus was developed by Technosigma, Okayama, Japan, using their patented technology. Torii, S.; Miki, K. PCT Japanese Patent Nos. 113927A, 2004; 004317, 2004; 131504A, 2005.
    • Torii, S.1    Miki, K.2
  • 21
    • 33746358028 scopus 로고    scopus 로고
    • note
    • Dichloromethane was evaporated rapidly using SolTrapper, and recovery was >90%, which was approximately twice the typical recovery obtained using vacuum centrifugation,
  • 22
    • 33746361044 scopus 로고    scopus 로고
    • note
    • A synthesizer with six positions for 100-mL vessels was used (Metz; Radleys Discovery Technologies, Saffron Walden, U.K.).
  • 24
    • 33746383116 scopus 로고    scopus 로고
    • U.S. Patent No. 6194465, 2001
    • (b) Flitter, W. D.; Garland, W. A.; Irwin, I. U.S. Patent No. 6194465, 2001.
  • 25
    • 33746362238 scopus 로고    scopus 로고
    • note
    • A vacuum centrifuge with eight positions for 100-mL vessels was used (CE-1; Hitachi, Tokyo, Japan).


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.