메뉴 건너뛰기




Volumn 55, Issue 5, 2006, Pages 1202-1209

Interactive continuously moving table (iCMT) large field-of-view real-time MRI

Author keywords

Interactive MR; Large FOV; Moving table; MR fluoroscopy; Real time imaging

Indexed keywords

DATA ACQUISITION; ENCODING (SYMBOLS); IMAGE RECONSTRUCTION; IMAGE SEGMENTATION; MAGNETIC RESONANCE IMAGING; SIGNAL ENCODING;

EID: 33646446583     PISSN: 07403194     EISSN: 15222594     Source Type: Journal    
DOI: 10.1002/mrm.20848     Document Type: Article
Times cited : (7)

References (34)
  • 1
    • 0036158390 scopus 로고    scopus 로고
    • Continuously moving table data acquisition method for long FOV contrast-enhanced MRA and whole-body MRI
    • Kruger DG, Riederer SJ, Grimm RC, Rossman PJ. Continuously moving table data acquisition method for long FOV contrast-enhanced MRA and whole-body MRI. Magn Reson Med 2002;47:224-231.
    • (2002) Magn Reson Med , vol.47 , pp. 224-231
    • Kruger, D.G.1    Riederer, S.J.2    Grimm, R.C.3    Rossman, P.J.4
  • 2
    • 0036667164 scopus 로고    scopus 로고
    • A new strategy for imaging blood vessels in the legs using magnetic resonance imaging (MRI)
    • Sabati M, Frayne R. A new strategy for imaging blood vessels in the legs using magnetic resonance imaging (MRI). Can J Elect Comput Eng (IEEE Can) 2002;27:117-121.
    • (2002) Can J Elect Comput Eng (IEEE Can) , vol.27 , pp. 117-121
    • Sabati, M.1    Frayne, R.2
  • 3
    • 0038778570 scopus 로고    scopus 로고
    • Extended field-of-view imaging with table translation and frequency sweeping
    • Zhu Y, Dumoulin CL. Extended field-of-view imaging with table translation and frequency sweeping. Magn Reson Med 2003;49:1106-1112.
    • (2003) Magn Reson Med , vol.49 , pp. 1106-1112
    • Zhu, Y.1    Dumoulin, C.L.2
  • 5
    • 0031403821 scopus 로고    scopus 로고
    • The effects of incomplete breath-holding on 3D MR image quality
    • Maki JH, Chenevert TL, Prince MR. The effects of incomplete breath-holding on 3D MR image quality. J Magn Reson Imaging 1997;7:1132-1139.
    • (1997) J Magn Reson Imaging , vol.7 , pp. 1132-1139
    • Maki, J.H.1    Chenevert, T.L.2    Prince, M.R.3
  • 6
    • 0032876353 scopus 로고    scopus 로고
    • Automated bolus chase peripheral MR angiography: Initial practical experiences and future directions of this work-in-progress
    • Ho VB, Choyke PL, Foo TKF, Hood MN, Miller DL, Czum JM, Aisen AM. Automated bolus chase peripheral MR angiography: initial practical experiences and future directions of this work-in-progress. J Magn Reson Imaging 1999;10:376-388.
    • (1999) J Magn Reson Imaging , vol.10 , pp. 376-388
    • Ho, V.B.1    Choyke, P.L.2    Foo, T.K.F.3    Hood, M.N.4    Miller, D.L.5    Czum, J.M.6    Aisen, A.M.7
  • 9
    • 12144276254 scopus 로고    scopus 로고
    • Dual-velocity continuously moving table acquisition for contrast-enhanced peripheral magnetic resonance angiography
    • Kruger DG, Riederer SJ, Polzin JA, Madhuranthakam AJ, Hu HH, Glockner JF. Dual-velocity continuously moving table acquisition for contrast-enhanced peripheral magnetic resonance angiography. Magn Reson Med 2005;53:110-117.
    • (2005) Magn Reson Med , vol.53 , pp. 110-117
    • Kruger, D.G.1    Riederer, S.J.2    Polzin, J.A.3    Madhuranthakam, A.J.4    Hu, H.H.5    Glockner, J.F.6
  • 10
    • 33646439342 scopus 로고    scopus 로고
    • Whole-body functional CE MRA to track the contrast bolus with high temporal resolution and real-time feedback controlled table motion
    • Miami Beach, FL, USA
    • Madhuranthakarn AJ, Hu HH, Kruger DG, Glockner JF, Riederer SJ. Whole-body functional CE MRA to track the contrast bolus with high temporal resolution and real-time feedback controlled table motion. In: Proceedings of the 13th Annual Meeting of ISMRM, Miami Beach, FL, USA, 2005. p 378.
    • (2005) Proceedings of the 13th Annual Meeting of ISMRM , pp. 378
    • Madhuranthakarn, A.J.1    Hu, H.H.2    Kruger, D.G.3    Glockner, J.F.4    Riederer, S.J.5
  • 13
  • 18
    • 0141849137 scopus 로고    scopus 로고
    • Space-time relationship in continuously moving table method for extended FOV peripheral CE MRA
    • Sabati M, Lauzon ML, Frayne R. Space-time relationship in continuously moving table method for extended FOV peripheral CE MRA. Phys Med Biol 2003;48:2739-2752.
    • (2003) Phys Med Biol , vol.48 , pp. 2739-2752
    • Sabati, M.1    Lauzon, M.L.2    Frayne, R.3
  • 19
    • 0034979158 scopus 로고    scopus 로고
    • Whole-body MR imaging in 30 seconds with real-time true FISP and a continuously rolling table platform: Feasibility study
    • Barkhausen J, Quick HH, Lauenstein T, Goyen M, Ruehm SG, Laub G, Debatin JF, Ladd ME. Whole-body MR imaging in 30 seconds with real-time true FISP and a continuously rolling table platform: feasibility study. Radiology 2001;220:252-256.
    • (2001) Radiology , vol.220 , pp. 252-256
    • Barkhausen, J.1    Quick, H.H.2    Lauenstein, T.3    Goyen, M.4    Ruehm, S.G.5    Laub, G.6    Debatin, J.F.7    Ladd, M.E.8
  • 20
    • 0002682680 scopus 로고    scopus 로고
    • Single bolus contrast enhanced peripheral 3D MRA using automated table motion integrated with automated bolus detection and acquisition triggering (SMARTPREP)
    • Sydney, Australia
    • Foo TKF, Vo VB, McCann RA, Moalemi A, Hood MD. Single bolus contrast enhanced peripheral 3D MRA using automated table motion integrated with automated bolus detection and acquisition triggering (SMARTPREP). In: Proceedings of the 6th Annual Meeting of ISMRM, Sydney, Australia, 1998. p 67.
    • (1998) Proceedings of the 6th Annual Meeting of ISMRM , pp. 67
    • Foo, T.K.F.1    Vo, V.B.2    McCann, R.A.3    Moalemi, A.4    Hood, M.D.5
  • 21
    • 33644909301 scopus 로고    scopus 로고
    • A real-time 3D large field-of-view MRI system with interactive table motion
    • Sabati M, Lauzon ML, Nagarajappa N, Frayne R. A real-time 3D large field-of-view MRI system with interactive table motion. Concepts Magn Reson B 2006;298:23-41.
    • (2006) Concepts Magn Reson B , vol.298 , pp. 23-41
    • Sabati, M.1    Lauzon, M.L.2    Nagarajappa, N.3    Frayne, R.4
  • 22
    • 33644926907 scopus 로고    scopus 로고
    • Fast correction of the gradient field non-uniformity for large FOV continuously moving table techniques
    • Kyoto, Japan
    • Sabati M, Nagarajappa N, Lauzon ML, Frayne R. Fast correction of the gradient field non-uniformity for large FOV continuously moving table techniques. In: Proceedings of the 12th Annual Meeting of ISMRM, Kyoto, Japan, 2004. p 2188.
    • (2004) Proceedings of the 12th Annual Meeting of ISMRM , pp. 2188
    • Sabati, M.1    Nagarajappa, N.2    Lauzon, M.L.3    Frayne, R.4
  • 26
    • 21244468916 scopus 로고    scopus 로고
    • Novel undersampled acquisition schemes for continuously moving table peripheral contrast-enhanced MRA
    • Toronto, Canada
    • Sabati M, Lauzon ML, Frayne R. Novel undersampled acquisition schemes for continuously moving table peripheral contrast-enhanced MRA. In: Proceedings of the 11th Annual Meeting of ISMRM, Toronto, Canada, 2003. p 252.
    • (2003) Proceedings of the 11th Annual Meeting of ISMRM , pp. 252
    • Sabati, M.1    Lauzon, M.L.2    Frayne, R.3
  • 28
    • 0036200239 scopus 로고    scopus 로고
    • Utilizing SENSE to achieve lower station sub-millimeter isotropic resolution and minimal venous enhancement in peripheral MR angiography
    • Maki JH, Wilson GJ, Eubank WB, Hoogeveen RM. Utilizing SENSE to achieve lower station sub-millimeter isotropic resolution and minimal venous enhancement in peripheral MR angiography. J Magn Reson Imaging 2002;15:484-491.
    • (2002) J Magn Reson Imaging , vol.15 , pp. 484-491
    • Maki, J.H.1    Wilson, G.J.2    Eubank, W.B.3    Hoogeveen, R.M.4
  • 30
    • 21244435579 scopus 로고    scopus 로고
    • Variable field of view for spatial resolution improvement in continuously moving table magnetic resonance imaging
    • Hu HH, Madhuranthakam AJ, Kruger DG, Glockner JF, Riederer SJ. Variable field of view for spatial resolution improvement in continuously moving table magnetic resonance imaging. Magn Reson Med 2005;54:146-151.
    • (2005) Magn Reson Med , vol.54 , pp. 146-151
    • Hu, H.H.1    Madhuranthakam, A.J.2    Kruger, D.G.3    Glockner, J.F.4    Riederer, S.J.5
  • 31
    • 7544244928 scopus 로고    scopus 로고
    • Floating table isotropic projection (FLIPR) acquisition: A time-resolved 3D method for extended field-of-view MRI during continuous table motion
    • Fain SB, Browning FJ, Polzin JA, Du J, Zhou Y, Block WF, Grist TM, Mistretta CA. Floating table isotropic projection (FLIPR) acquisition: a time-resolved 3D method for extended field-of-view MRI during continuous table motion. Magn Reson Med 2004;52:1093-1102.
    • (2004) Magn Reson Med , vol.52 , pp. 1093-1102
    • Fain, S.B.1    Browning, F.J.2    Polzin, J.A.3    Du, J.4    Zhou, Y.5    Block, W.F.6    Grist, T.M.7    Mistretta, C.A.8
  • 32
    • 12144252522 scopus 로고    scopus 로고
    • Continuously moving table SENSE imaging
    • Keupp J, Aldefeld B, Bornert P. Continuously moving table SENSE imaging. Magn Reson Med 2005;53:217-220.
    • (2005) Magn Reson Med , vol.53 , pp. 217-220
    • Keupp, J.1    Aldefeld, B.2    Bornert, P.3
  • 33
    • 24144469362 scopus 로고    scopus 로고
    • Whole-body magnetic resonance imaging featuring moving table continuous data acquisition with high-precision position feedback
    • Zenge MO, Ladd ME, Vogt FM, Brauck K, Joekel M, Barkhausen J, Quick HH. Whole-body magnetic resonance imaging featuring moving table continuous data acquisition with high-precision position feedback. Magn Reson Med 2005;54:707-711.
    • (2005) Magn Reson Med , vol.54 , pp. 707-711
    • Zenge, M.O.1    Ladd, M.E.2    Vogt, F.M.3    Brauck, K.4    Joekel, M.5    Barkhausen, J.6    Quick, H.H.7


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.