메뉴 건너뛰기




Volumn 54, Issue 3, 2005, Pages 707-711

Whole-body magnetic resonance imaging featuring moving table continuous data acquisition with high-precision position feedback

Author keywords

AngioSURF; Continuous data acquisition; Large FOV; Phased array surface RF coils; TrueFISP; Whole body MRI

Indexed keywords

FEEDBACK; MAGNETIC RESONANCE IMAGING;

EID: 24144469362     PISSN: 07403194     EISSN: None     Source Type: Journal    
DOI: 10.1002/mrm.20598     Document Type: Article
Times cited : (26)

References (15)
  • 6
    • 0034979158 scopus 로고    scopus 로고
    • Whole-body MR imaging in 30 seconds with real-time true FISP and a continuously rolling table platform: Feasibility study
    • Barkhausen J, Quick HH, Lauenstein T, Goyen M, Ruehm SG, Laub G, Debatin JF, Ladd ME. Whole-body MR imaging in 30 seconds with real-time true FISP and a continuously rolling table platform: feasibility study. Radiology 2001;220:252-256.
    • (2001) Radiology , vol.220 , pp. 252-256
    • Barkhausen, J.1    Quick, H.H.2    Lauenstein, T.3    Goyen, M.4    Ruehm, S.G.5    Laub, G.6    Debatin, J.F.7    Ladd, M.E.8
  • 8
    • 0000557592 scopus 로고    scopus 로고
    • Extending the coverage of true volume scans by continuous movement of the subject
    • Philadelphia
    • Dietrich O, Hajnal JV. Extending the coverage of true volume scans by continuous movement of the subject. In: Proceedings of the 7th Annual Meeting of ISMRM, Philadelphia, 1999. p 1653.
    • (1999) Proceedings of the 7th Annual Meeting of ISMRM , pp. 1653
    • Dietrich, O.1    Hajnal, J.V.2
  • 9
    • 0008237644 scopus 로고    scopus 로고
    • FUSION for incremental field-of view imaging
    • Glasgow, Scotland
    • Zhu Y. FUSION for incremental field-of view imaging. In: Proceedings of the 9th Annual Meeting of ISMRM, Glasgow, Scotland, 2001. p 9.
    • (2001) Proceedings of the 9th Annual Meeting of ISMRM , pp. 9
    • Zhu, Y.1
  • 11
    • 0038778570 scopus 로고    scopus 로고
    • Extended field-of-view imaging with table translation and frequency sweeping
    • Zhu Y, Dumoulin CL. Extended field-of-view imaging with table translation and frequency sweeping. Magn Reson Med 2003;49:1106-1112.
    • (2003) Magn Reson Med , vol.49 , pp. 1106-1112
    • Zhu, Y.1    Dumoulin, C.L.2
  • 12
    • 0036158390 scopus 로고    scopus 로고
    • Continuously moving table data acquisition method for long FOV contrast-enhanced MRA and whole-body MRI
    • Kruger DG, Riederer SJ, Grimm RC, Rossman PJ. Continuously moving table data acquisition method for long FOV contrast-enhanced MRA and whole-body MRI. Magn Reson Med 2002;47:224-231.
    • (2002) Magn Reson Med , vol.47 , pp. 224-231
    • Kruger, D.G.1    Riederer, S.J.2    Grimm, R.C.3    Rossman, P.J.4
  • 15
    • 33645588897 scopus 로고    scopus 로고
    • Continuous adjustment of calibration values for improved image quality in continuously moving table imaging
    • Kyoto, Japan
    • Shankaranarayanan A, Brittain JH. Continuous adjustment of calibration values for improved image quality in continuously moving table imaging. In: Proceedings of the 12th Annual Meeting of ISMRM, Kyoto, Japan, 2004. p 103.
    • (2004) Proceedings of the 12th Annual Meeting of ISMRM , pp. 103
    • Shankaranarayanan, A.1    Brittain, J.H.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.