메뉴 건너뛰기




Volumn 6036, Issue , 2006, Pages

Thermal modeling of a microheater in a microchannel chip

Author keywords

CFD; Infrared imaging; Microchannel; Microheater

Indexed keywords

BIOMEDICAL ENGINEERING; COMPUTATIONAL FLUID DYNAMICS; COOLING; FLOW OF FLUIDS; INFRARED IMAGING; TEMPERATURE DISTRIBUTION;

EID: 33645228959     PISSN: 16057422     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1117/12.660972     Document Type: Conference Paper
Times cited : (1)

References (18)
  • 1
    • 0037207719 scopus 로고    scopus 로고
    • Thick and thermally isolated Si microheaters for microfabricated preconcentrators
    • Tian, W.-C. and S. W. Pang, 2003. Thick and thermally isolated Si microheaters for microfabricated preconcentrators. J. Vac. Sci. Technol. B. 21, 274-279.
    • (2003) J. Vac. Sci. Technol. B , vol.21 , pp. 274-279
    • Tian, W.-C.1    Pang, S.W.2
  • 2
    • 14744305706 scopus 로고    scopus 로고
    • Integrated and microheater embedded gas sensor array based on the polymer composites dispensed in micromachined wells
    • Ha, S.-C., Y. S. Kim, Y. Yang, Y. J. Kim, S.-M. Cho, H.Yang and Y. T. Kim, 2005. Integrated and microheater embedded gas sensor array based on the polymer composites dispensed in micromachined wells, Sensors and Actuators B 105, 549-555.
    • (2005) Sensors and Actuators B , vol.105 , pp. 549-555
    • Ha, S.-C.1    Kim, Y.S.2    Yang, Y.3    Kim, Y.J.4    Cho, S.-M.5    Yang, H.6    Kim, Y.T.7
  • 6
    • 0033315202 scopus 로고    scopus 로고
    • A metallic oxide gas sensor array for a selective detection of the CO and NH gases
    • Chambon, L., J.P. Germain, A. Pauly, V. Demarne and A. Grisel, 1999. A metallic oxide gas sensor array for a selective detection of the CO and NH gases, Sensors and Actuators B, 60, 138-147.
    • (1999) Sensors and Actuators B , vol.60 , pp. 138-147
    • Chambon, L.1    Germain, J.P.2    Pauly, A.3    Demarne, V.4    Grisel, A.5
  • 9
    • 4644312409 scopus 로고    scopus 로고
    • Design, fabrication, and test of a peristaltic micropump
    • Knight, M. and J. House, 2004. Design, fabrication, and test of a peristaltic micropump, Microsystem Technologies, 10, 426-431.
    • (2004) Microsystem Technologies , vol.10 , pp. 426-431
    • Knight, M.1    House, J.2
  • 10
    • 0034830475 scopus 로고    scopus 로고
    • A self-filling micropump based on PCB technology
    • Wego, A. and L. Pagel, 2001. A self-filling micropump based on PCB technology, Sensors and Actuators A, 88, 220-226.
    • (2001) Sensors and Actuators A , vol.88 , pp. 220-226
    • Wego, A.1    Pagel, L.2
  • 11
    • 0000087993 scopus 로고    scopus 로고
    • A polysilicon flow sensor for gas flow meters
    • Neda, T.; Nakamura, K.; Takumi, T. 1996. A polysilicon flow sensor for gas flow meters, Sensors and Actuators A, 54, 626-631.
    • (1996) Sensors and Actuators A , vol.54 , pp. 626-631
    • Neda, T.1    Nakamura, K.2    Takumi, T.3
  • 12
    • 0031213628 scopus 로고    scopus 로고
    • Silicon probe with integrated micrometers for thermal marking and monitoring of neural tissue
    • Wise, K. D. and J. Chen, 1997. Silicon probe with integrated micrometers for thermal marking and monitoring of neural tissue, 44 IEEE Transactions on Biomedical Engineering, 770-774.
    • (1997) IEEE Transactions on Biomedical Engineering , vol.44 , pp. 770-774
    • Wise, K.D.1    Chen, J.2
  • 13
    • 0033355466 scopus 로고    scopus 로고
    • A new technology for fluidic microsystems based on PCB technology
    • Merkel, T., M. Graeber abd L. Pagel, 1999. A new technology for fluidic microsystems based on PCB technology, Sensors and Actuators A, 77, 98-105.
    • (1999) Sensors and Actuators A , vol.77 , pp. 98-105
    • Merkel, T.1    Graeber, M.2    Pagel, L.3
  • 14
    • 0035443367 scopus 로고    scopus 로고
    • Fluidic Microsystems based on printed circuit board technology
    • Wego, A., S. Richter and L. Pagel, 2001, Fluidic Microsystems based on printed circuit board technology. J. Micromech. Microeng. 11, 528-531.
    • (2001) J. Micromech. Microeng. , vol.11 , pp. 528-531
    • Wego, A.1    Richter, S.2    Pagel, L.3
  • 15
    • 0035975578 scopus 로고    scopus 로고
    • Investigations of thermo-pneumatic volume actuators based on PCB technology
    • Wego A., H.-W. Glock, L. Pagel and S. Richter, 2001. Investigations of thermo-pneumatic volume actuators based on PCB technology. Sensors and Actuators A, 93, 95-102.
    • (2001) Sensors and Actuators A , vol.93 , pp. 95-102
    • Wego, A.1    Glock, H.-W.2    Pagel, L.3    Richter, S.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.