메뉴 건너뛰기




Volumn 13, Issue 7, 2003, Pages 1501-1507

Diagnosis of pulmonary embolism with spiral CT as a second procedure following scintigraphy

Author keywords

Comparative studies; Computed tomography; Perfusion scan; Pulmonary angiography; Pulmonary embolism; Ventilation scan

Indexed keywords

IODINATED CONTRAST MEDIUM; IOMEPROL; IOMERON 350; IOPROMIDE; NONIONIC CONTRAST MEDIUM; TECHNETIUM 99M;

EID: 0037591923     PISSN: 09387994     EISSN: None     Source Type: Journal    
DOI: 10.1007/s00330-002-1709-3     Document Type: Article
Times cited : (38)

References (23)
  • 1
    • 0032603546 scopus 로고    scopus 로고
    • Update on diagnostic strategies of pulmonary embolism
    • Kauczor HU, Heussel CP, Thelen M (1999) Update on diagnostic strategies of pulmonary embolism. Eur Radiol 9:262-275
    • (1999) Eur. Radiol. , vol.9 , pp. 262-275
    • Kauczor, H.U.1    Heussel, C.P.2    Thelen, M.3
  • 2
    • 0022406249 scopus 로고
    • Diagnostic value of ventilation-perfusion lung scanning in patients with suspected pulmonary embolism
    • Hull RD, Hirsh J, Carter CJ, Raskob GE et al. (1985) Diagnostic value of ventilation-perfusion lung scanning in patients with suspected pulmonary embolism. Chest 88:819-828
    • (1985) Chest , vol.88 , pp. 819-828
    • Hull, R.D.1    Hirsh, J.2    Carter, C.J.3    Raskob, G.E.4
  • 4
    • 0025354523 scopus 로고
    • Value of the ventilation/perfusion scan in acute pulmonary embolism. Results of the prospective investigation of pulmonary embolism diagnosis (PIOPED)
    • The PIOPED investigators
    • The PIOPED investigators (1990) Value of the ventilation/perfusion scan in acute pulmonary embolism. Results of the prospective investigation of pulmonary embolism diagnosis (PIOPED). J Am Med Assoc 263:2753-2759
    • (1990) J. Am. Med. Assoc. , vol.263 , pp. 2753-2759
  • 6
    • 0034142339 scopus 로고    scopus 로고
    • Sensitivity and specificity of helical computed tomography in the diagnosis of pulmonary embolism: A systematic review
    • Rathbun SW, Raskob GE, Whitsett TL (2000) Sensitivity and specificity of helical computed tomography in the diagnosis of pulmonary embolism: a systematic review. Ann Intern Med 132:227-232
    • (2000) Ann. Intern. Med. , vol.132 , pp. 227-232
    • Rathbun, S.W.1    Raskob, G.E.2    Whitsett, T.L.3
  • 7
    • 0030716466 scopus 로고    scopus 로고
    • Acute pulmonary embolism: Role of helical CT in 164 patients with intermediate probability at ventilation-perfusion scintigraphy and normal results at duplex US of the legs
    • Ferretti GR, Bosson PD, Buffaz PD et al. (1997) Acute pulmonary embolism: role of helical CT in 164 patients with intermediate probability at ventilation-perfusion scintigraphy and normal results at duplex US of the legs. Radiology 205:453-458
    • (1997) Radiology , vol.205 , pp. 453-458
    • Ferretti, G.R.1    Bosson, P.D.2    Buffaz, P.D.3
  • 8
    • 0030711577 scopus 로고    scopus 로고
    • Pulmonary embolism: Prospective comparison of spiral-CT with ventilation-perfusion scintigraphy
    • Mayo JR, Remy-Jardin M, Müller NL et al. (1997) Pulmonary embolism: prospective comparison of spiral-CT with ventilation-perfusion scintigraphy. Radiology 205:447-452
    • (1997) Radiology , vol.205 , pp. 447-452
    • Mayo, J.R.1    Remy-Jardin, M.2    Müller, N.L.3
  • 9
    • 0029831577 scopus 로고    scopus 로고
    • Diagnosis of pulmonary embolism with spiral CT: Comparison with pulmonary angiography and scintigraphy
    • Remy-Jardin M, Remy J, Deschildre F et al. (1996) Diagnosis of pulmonary embolism with spiral CT: comparison with pulmonary angiography and scintigraphy. Radiology 200:699-706
    • (1996) Radiology , vol.200 , pp. 699-706
    • Remy-Jardin, M.1    Remy, J.2    Deschildre, F.3
  • 10
    • 0030039489 scopus 로고    scopus 로고
    • Role of spiral volumetric computed tomographic scanning in the assessment of patients with clinical suspicion of pulmonary embolism and an abnormal ventilation/perfusion lung scan
    • Van Rossum AB, Treurniet FE, Kieft GJ, Smith SJ, Schepers-Bok R (1996) Role of spiral volumetric computed tomographic scanning in the assessment of patients with clinical suspicion of pulmonary embolism and an abnormal ventilation/perfusion lung scan. Thorax 51:23-28
    • (1996) Thorax , vol.51 , pp. 23-28
    • Van Rossum, A.B.1    Treurniet, F.E.2    Kieft, G.J.3    Smith, S.J.4    Schepers-Bok, R.5
  • 11
    • 0029026454 scopus 로고
    • Detection of pulmonary embolism in patients with unresolved clinical and scintigraphic diagnosis: Helical CT versus angiography
    • Goodman LR, Curtin JJ, Mewissen MW et al. (1995) Detection of pulmonary embolism in patients with unresolved clinical and scintigraphic diagnosis: helical CT versus angiography. Am J Roentgenol 164:1369-1374
    • (1995) Am. J. Roentgenol. , vol.164 , pp. 1369-1374
    • Goodman, L.R.1    Curtin, J.J.2    Mewissen, M.W.3
  • 12
    • 0031666752 scopus 로고    scopus 로고
    • Acute pulmonary embolism: Assessment of helical CT for diagnosis
    • Drucker EA, Rivitz SM, Shepard JA et al. (1998) Acute pulmonary embolism: assessment of helical CT for diagnosis. Radiology 209:235-241
    • (1998) Radiology , vol.209 , pp. 235-241
    • Drucker, E.A.1    Rivitz, S.M.2    Shepard, J.A.3
  • 13
    • 0028787550 scopus 로고
    • Comprehensive analysis of the results of the PIOPED study
    • Worsley DF, Alavi A (1995) Comprehensive analysis of the results of the PIOPED study. J. Nucl Med 36:2380-2387
    • (1995) J. Nucl. Med. , vol.36 , pp. 2380-2387
    • Worsley, D.F.1    Alavi, A.2
  • 14
    • 0015071985 scopus 로고
    • Non-uniform pulmonary arterial perfusion: Pulmonary embolism
    • Sagel SS, Greenspan RH (1970) Non-uniform pulmonary arterial perfusion: pulmonary embolism. Radiology 99:541-548
    • (1970) Radiology , vol.99 , pp. 541-548
    • Sagel, S.S.1    Greenspan, R.H.2
  • 15
    • 0028236973 scopus 로고
    • Spiral-computed tomography versus pulmonary angiography in the diagnosis of acute massive pulmonary embolism
    • Blum AG, Delfau F, Grignon B et al. (1994) Spiral-computed tomography versus pulmonary angiography in the diagnosis of acute massive pulmonary embolism. Am J Cardiol 74:96-98
    • (1994) Am. J. Cardiol. , vol.74 , pp. 96-98
    • Blum, A.G.1    Delfau, F.2    Grignon, B.3
  • 16
    • 0033752851 scopus 로고    scopus 로고
    • Pulmonary embolism detection: Prospective evaluation of dual-section helical CT versus selective pulmonary arteriography in 157 patients
    • Qanadli SD, El Hajjam M, Mesurolle B et al. (2000) Pulmonary embolism detection: prospective evaluation of dual-section helical CT versus selective pulmonary arteriography in 157 patients. Radiology 217:447-455
    • (2000) Radiology , vol.217 , pp. 447-455
    • Qanadli, S.D.1    El Hajjam, M.2    Mesurolle, B.3
  • 18
    • 0000847165 scopus 로고    scopus 로고
    • Opinions/hypotheses: Opinions regarding the diagnosis and management of venous thromboembolic disease
    • Stein PD, Goldhaber SZ, Gottschalk A et al. (1998) Opinions/hypotheses: opinions regarding the diagnosis and management of venous thromboembolic disease. Chest 113:499-504
    • (1998) Chest , vol.113 , pp. 499-504
    • Stein, P.D.1    Goldhaber, S.Z.2    Gottschalk, A.3
  • 19
    • 0031010385 scopus 로고    scopus 로고
    • Peripheral pulmonary arteries: Optimization of the spiral CT acquisition protocol
    • Remy-Jardin M, Remy J, Artaud D, Deschildre F, Duhamel A (1997) Peripheral pulmonary arteries: optimization of the spiral CT acquisition protocol. Radiology 204:157-1563
    • (1997) Radiology , vol.204 , pp. 157-1563
    • Remy-Jardin, M.1    Remy, J.2    Artaud, D.3    Deschildre, F.4    Duhamel, A.5
  • 21
    • 10544242199 scopus 로고    scopus 로고
    • Value of perfusion lung scan in the diagnosis of pulmonary embolism: Results of the Prospective Investigative Study of Acute Pulmonary Embolism diagnosis (PISA-PED)
    • Miniati M, Pistolesi M, Marini C, Ricco G di, Formichi B, Prediletto R et al. (1996) Value of perfusion lung scan in the diagnosis of pulmonary embolism: results of the Prospective Investigative Study of Acute Pulmonary Embolism diagnosis (PISA-PED). Am J Respir Crit Care Med 154:1387-1393
    • (1996) Am. J. Respir. Crit. Care Med. , vol.154 , pp. 1387-1393
    • Miniati, M.1    Pistolesi, M.2    Marini, C.3    di Ricco, G.4    Formichi, B.5    Prediletto, R.6
  • 22
    • 0031878546 scopus 로고    scopus 로고
    • Pulmonary embolism: Diagnosis with spiral CT and ventilation-perfusion scintigraphy: Correlation with pulmonary angiographic results or clinical outcome
    • Garg K, Welsh CH, Feyerabend AJ et al. (1998) Pulmonary embolism: diagnosis with spiral CT and ventilation-perfusion scintigraphy: correlation with pulmonary angiographic results or clinical outcome. Radiology 208:201-208
    • (1998) Radiology , vol.208 , pp. 201-208
    • Garg, K.1    Welsh, C.H.2    Feyerabend, A.J.3
  • 23
    • 0030045298 scopus 로고    scopus 로고
    • Pulmonary embolism: Interobserver agreement in the interpretation of conventional angiographic and DSA images in patients with nondiagnostic lung scan results
    • Van Beek EJ, Bakker AJ, Reekers JA (1996) Pulmonary embolism: interobserver agreement in the interpretation of conventional angiographic and DSA images in patients with nondiagnostic lung scan results. Radiology 198:721-724
    • (1996) Radiology , vol.198 , pp. 721-724
    • Van Beek, E.J.1    Bakker, A.J.2    Reekers, J.A.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.