메뉴 건너뛰기




Volumn 41, Issue 1, 2006, Pages 103-112

Effective detection of peptides containing cysteine sulfonic acid using matrix-assisted laser desorption/ionization and laser desorption/ionization on porous silicon mass spectrometry

Author keywords

Cysteine sulfonic acid; Desorption ionization on porous silicon; Matrix additive; Matrix assisted laser desorption ionization; Peptide

Indexed keywords

ACIDITY; IONIZATION; MASS SPECTROMETRY; ORGANIC ACIDS; POROUS SILICON; PROTEINS; SIGNAL TO NOISE RATIO;

EID: 31544460928     PISSN: 10765174     EISSN: 10969888     Source Type: Journal    
DOI: 10.1002/jms.973     Document Type: Article
Times cited : (22)

References (39)
  • 1
    • 0037184525 scopus 로고    scopus 로고
    • How to flip the (redox) switch
    • Georgiou G. How to flip the (redox) switch. Cell 2002; 111: 607.
    • (2002) Cell , vol.111 , pp. 607
    • Georgiou, G.1
  • 3
    • 0028072911 scopus 로고
    • Thioredoxin-dependent peroxide reductase from yeast
    • Chae HZ, Chung SJ, Rhee SG. Thioredoxin-dependent peroxide reductase from yeast. J. Biol. Chem. 1994; 269: 27670.
    • (1994) J. Biol. Chem. , vol.269 , pp. 27670
    • Chae, H.Z.1    Chung, S.J.2    Rhee, S.G.3
  • 4
    • 19444375216 scopus 로고    scopus 로고
    • Peroxiredoxins: A historical overview and speculative preview of novel mechanisms and emerging concepts in cell signaling
    • Rhee SG, Chae HZ, Kim K. Peroxiredoxins: a historical overview and speculative preview of novel mechanisms and emerging concepts in cell signaling. Free Radical Biol. Med. 2005; 38: 1543.
    • (2005) Free Radical Biol. Med. , vol.38 , pp. 1543
    • Rhee, S.G.1    Chae, H.Z.2    Kim, K.3
  • 5
    • 0037205455 scopus 로고    scopus 로고
    • Proteomics analysis of cellular response to oxidative stress. Evidence for in vivo overoxidation of peroxiredoxins at their active site
    • Rabilloud T, Heller M, Gasnier F, Luche S, Rey C, Aebersold R, Benahmed M, Louisot P, Lunardi J. Proteomics analysis of cellular response to oxidative stress. Evidence for in vivo overoxidation of peroxiredoxins at their active site. J. Biol. Chem. 2002; 277: 19396.
    • (2002) J. Biol. Chem. , vol.277 , pp. 19396
    • Rabilloud, T.1    Heller, M.2    Gasnier, F.3    Luche, S.4    Rey, C.5    Aebersold, R.6    Benahmed, M.7    Louisot, P.8    Lunardi, J.9
  • 6
    • 1842581669 scopus 로고    scopus 로고
    • Oxidative modifications and down-regulation of ubiquitin carboxyl-terminal hydrolase L1 associated with idiopathic Parkinson's and Alzheimer's diseases
    • Choi J, Levey AI, Weintraub ST, Rees HD, Gearing M, Chin LS, Li L. Oxidative modifications and down-regulation of ubiquitin carboxyl-terminal hydrolase L1 associated with idiopathic Parkinson's and Alzheimer's diseases. J. Biol. Chem. 2004; 279: 13256.
    • (2004) J. Biol. Chem. , vol.279 , pp. 13256
    • Choi, J.1    Levey, A.I.2    Weintraub, S.T.3    Rees, H.D.4    Gearing, M.5    Chin, L.S.6    Li, L.7
  • 7
    • 0035798684 scopus 로고    scopus 로고
    • Hypochlorous acid oxygenates the cysteine switch domain of pro-matrilysin (MMP-7). A mechanism for matrix metalloproteinase activation and atherosclerotic plaque rupture by myeloperoxidase
    • Fu X, Kassim SY, Parks WC, Heinecke JW. Hypochlorous acid oxygenates the cysteine switch domain of pro-matrilysin (MMP-7). A mechanism for matrix metalloproteinase activation and atherosclerotic plaque rupture by myeloperoxidase. J. Biol. Chem. 2001; 276: 41279.
    • (2001) J. Biol. Chem. , vol.276 , pp. 41279
    • Fu, X.1    Kassim, S.Y.2    Parks, W.C.3    Heinecke, J.W.4
  • 9
    • 1842740232 scopus 로고    scopus 로고
    • Cysteine-106 of DJ-1 is the most sensitive cysteine residue to hydrogen peroxide-mediated oxidation in vivo in human umbilical vein endothelial cells
    • Kinumi T, Kimata J, Taira T, Ariga H, Niki E. Cysteine-106 of DJ-1 is the most sensitive cysteine residue to hydrogen peroxide-mediated oxidation in vivo in human umbilical vein endothelial cells. Biochem. Biophys. Res. Commun. 2004; 317: 722.
    • (2004) Biochem. Biophys. Res. Commun. , vol.317 , pp. 722
    • Kinumi, T.1    Kimata, J.2    Taira, T.3    Ariga, H.4    Niki, E.5
  • 10
    • 0024289037 scopus 로고
    • Laser desorption ionization of proteins with molecular masses exceeding 10 000 daltons
    • Karas M, Hillenkamp F. Laser desorption ionization of proteins with molecular masses exceeding 10 000 daltons. Anal. Chem. 1988; 60: 2299.
    • (1988) Anal. Chem. , vol.60 , pp. 2299
    • Karas, M.1    Hillenkamp, F.2
  • 11
    • 84984042980 scopus 로고
    • Protein and polymer analyses up to m/z 100 000 by laser desorption ionization time-of-flight mass spectrometry
    • Tanaka K, Waki H, Ido Y, Akita S, Yoshida Y, Yoshida T. Protein and polymer analyses up to m/z 100 000 by laser desorption ionization time-of-flight mass spectrometry. Rapid Commun. Mass Spectrom. 1988; 2: 151.
    • (1988) Rapid Commun. Mass Spectrom. , vol.2 , pp. 151
    • Tanaka, K.1    Waki, H.2    Ido, Y.3    Akita, S.4    Yoshida, Y.5    Yoshida, T.6
  • 14
    • 12744268421 scopus 로고    scopus 로고
    • Mitochondrial proteomic analysis of a cell line model of familial amyotrophic lateral sclerosis
    • Fukada K, Zhang F, Vien A, Cashman NR, Zhu H. Mitochondrial proteomic analysis of a cell line model of familial amyotrophic lateral sclerosis. Mol. Cell. Proteomics 2004; 3: 1211.
    • (2004) Mol. Cell. Proteomics , vol.3 , pp. 1211
    • Fukada, K.1    Zhang, F.2    Vien, A.3    Cashman, N.R.4    Zhu, H.5
  • 15
    • 0028346026 scopus 로고
    • Mass spectrometric molecular-weight determination of highly acidic compounds of biological significance via their complexes with basic polypeptides
    • Juhasz P, Biemann K. Mass spectrometric molecular-weight determination of highly acidic compounds of biological significance via their complexes with basic polypeptides. Proc. Natl. Acad. Sci. U.S.A. 1994; 91: 4333.
    • (1994) Proc. Natl. Acad. Sci. U.S.A. , vol.91 , pp. 4333
    • Juhasz, P.1    Biemann, K.2
  • 16
    • 0028166698 scopus 로고
    • Monitoring protein kinase and phosphatase reactions with matrix-assisted laser desorption/ionization mass spectrometry and capillary zone electrophoresis: Comparison of the detection efficiency of peptide- phosphopeptide mixtures
    • Craig AG, Hoeger CA, Miller CL, Goedken T, Rivier JE, Fischer WH. Monitoring protein kinase and phosphatase reactions with matrix-assisted laser desorption/ionization mass spectrometry and capillary zone electrophoresis: comparison of the detection efficiency of peptide-phosphopeptide mixtures. Biol. Mass Spectrom. 1994; 23: 519.
    • (1994) Biol. Mass Spectrom. , vol.23 , pp. 519
    • Craig, A.G.1    Hoeger, C.A.2    Miller, C.L.3    Goedken, T.4    Rivier, J.E.5    Fischer, W.H.6
  • 17
    • 0029979976 scopus 로고    scopus 로고
    • Influence of matrix solution conditions on the MALDI-MS analysis of peptides and proteins
    • Cohen SL, Chait BT. Influence of matrix solution conditions on the MALDI-MS analysis of peptides and proteins. Anal. Chem. 1996; 68: 31.
    • (1996) Anal. Chem. , vol.68 , pp. 31
    • Cohen, S.L.1    Chait, B.T.2
  • 18
    • 0031871699 scopus 로고    scopus 로고
    • Suppression effects in enzymatic peptide ladder sequencing using ultraviolet - Matrix assisted laser desorption/ionization - Mass spectrometry
    • Kratzer R, Eckerskorn C, Karas M, Lottspeich F. Suppression effects in enzymatic peptide ladder sequencing using ultraviolet - matrix assisted laser desorption/ionization - mass spectrometry. Electrophoresis 1998; 19: 1910.
    • (1998) Electrophoresis , vol.19 , pp. 1910
    • Kratzer, R.1    Eckerskorn, C.2    Karas, M.3    Lottspeich, F.4
  • 20
    • 0000866601 scopus 로고
    • Analysis of oligodeoxynucleotides by negative-ion matrix-assisted laser desorption mass spectrometry
    • Currie GJ III, Yates JR. Analysis of oligodeoxynucleotides by negative-ion matrix-assisted laser desorption mass spectrometry. J. Am. Soc. Mass Spectrom. 1993; 4: 955.
    • (1993) J. Am. Soc. Mass Spectrom. , vol.4 , pp. 955
    • Currie III, G.J.1    Yates, J.R.2
  • 21
    • 0027240210 scopus 로고
    • Matrix-assisted laser desorption ionization time-of-flight mass spectrometry: A powerful tool for the mass and sequence analysis of natural and modified oligonucleotides
    • Pieles U, Zurcher W, Schar M, Moser HE. Matrix-assisted laser desorption ionization time-of-flight mass spectrometry: a powerful tool for the mass and sequence analysis of natural and modified oligonucleotides. Nucleic Acids Res. 1993; 21: 3191.
    • (1993) Nucleic Acids Res. , vol.21 , pp. 3191
    • Pieles, U.1    Zurcher, W.2    Schar, M.3    Moser, H.E.4
  • 22
    • 0033238004 scopus 로고    scopus 로고
    • Enhanced detection of phosphopeptides in matrix-assisted laser desorption/ionization mass spectrometry using ammonium salts
    • Asara JM, Allison J. Enhanced detection of phosphopeptides in matrix-assisted laser desorption/ionization mass spectrometry using ammonium salts. J. Am. Soc. Mass Spectrom. 1999; 10: 35.
    • (1999) J. Am. Soc. Mass Spectrom. , vol.10 , pp. 35
    • Asara, J.M.1    Allison, J.2
  • 23
    • 0345188660 scopus 로고    scopus 로고
    • Desorption-ionization mass spectrometry on porous silicon
    • Wei J, Buriak JM, Siuzdak G. Desorption-ionization mass spectrometry on porous silicon. Nature 1999; 399: 243.
    • (1999) Nature , vol.399 , pp. 243
    • Wei, J.1    Buriak, J.M.2    Siuzdak, G.3
  • 24
    • 1642326559 scopus 로고    scopus 로고
    • Activation of the antioxidant enzyme 1-CYS peroxiredoxin requires glutathionylation mediated by heterodimerization with pi GST
    • Manevich Y, Feinstein SI, Fisher AB. Activation of the antioxidant enzyme 1-CYS peroxiredoxin requires glutathionylation mediated by heterodimerization with pi GST. Proc. Natl. Acad. Sci. U.S.A. 2004; 101: 3780.
    • (2004) Proc. Natl. Acad. Sci. U.S.A. , vol.101 , pp. 3780
    • Manevich, Y.1    Feinstein, S.I.2    Fisher, A.B.3
  • 25
    • 0346850874 scopus 로고    scopus 로고
    • Reversible oxidation of the active site cysteine of peroxiredoxins to cysteine sulfinic acid. Immunoblot detection with antibodies specific for the hyperoxidized cysteine-containing sequence
    • Woo HA, Kang SW, Kim HK, Yang KS, Chae HZ, Rhee SG. Reversible oxidation of the active site cysteine of peroxiredoxins to cysteine sulfinic acid. Immunoblot detection with antibodies specific for the hyperoxidized cysteine-containing sequence. J. Biol. Chem. 2003; 278: 47361.
    • (2003) J. Biol. Chem. , vol.278 , pp. 47361
    • Woo, H.A.1    Kang, S.W.2    Kim, H.K.3    Yang, K.S.4    Chae, H.Z.5    Rhee, S.G.6
  • 27
    • 0028957687 scopus 로고
    • Quantitative bioanalysis using matrix-assisted laser desorption/ ionization mass spectrometry
    • Jespersen S, Niessen WMA, Tjaden UR, van der Greef J. Quantitative bioanalysis using matrix-assisted laser desorption/ionization mass spectrometry. J. Mass Spectrom. 1995; 30: 357.
    • (1995) J. Mass Spectrom. , vol.30 , pp. 357
    • Jespersen, S.1    Niessen, W.M.A.2    Tjaden, U.R.3    Van Der Greef, J.4
  • 28
    • 0036729136 scopus 로고    scopus 로고
    • Practical quantitative biomedical applications of MALDI-TOF mass spectrometry
    • Bucknall M, Fung KYC, Duncan MW. Practical quantitative biomedical applications of MALDI-TOF mass spectrometry. J. Am. Soc. Mass Spectrom. 2002; 13: 1015.
    • (2002) J. Am. Soc. Mass Spectrom. , vol.13 , pp. 1015
    • Bucknall, M.1    Fung, K.Y.C.2    Duncan, M.W.3
  • 30
    • 11244296899 scopus 로고    scopus 로고
    • Further studies on the fragmentation of protonated ions of peptides containing aspartic acid, glutamic acid, cysteine sulfinic acid, and cysteine sulfonic acid
    • Men L, Wang Y. Further studies on the fragmentation of protonated ions of peptides containing aspartic acid, glutamic acid, cysteine sulfinic acid, and cysteine sulfonic acid. Rapid Commun. Mass Spectrom. 2005; 19: 23.
    • (2005) Rapid Commun. Mass Spectrom. , vol.19 , pp. 23
    • Men, L.1    Wang, Y.2
  • 31
    • 0034845380 scopus 로고    scopus 로고
    • Phosphopeptide analysis by positive and negative ion matrix-assisted laser desorption/ionization mass spectrometry
    • Janek K, Wenschuh H, Bienert M, Krause E. Phosphopeptide analysis by positive and negative ion matrix-assisted laser desorption/ionization mass spectrometry. Rapid Commun. Mass Spectrom. 2001; 15: 1593.
    • (2001) Rapid Commun. Mass Spectrom. , vol.15 , pp. 1593
    • Janek, K.1    Wenschuh, H.2    Bienert, M.3    Krause, E.4
  • 32
    • 67650440289 scopus 로고
    • Amino acid composition and wavelength effects in matrix-assisted laser desorption/ionization
    • Olumee Z, Sadeghi M, Tang X, Vertes A. Amino acid composition and wavelength effects in matrix-assisted laser desorption/ionization. Rapid Commun. Mass Spectrom. 1995; 9: 744.
    • (1995) Rapid Commun. Mass Spectrom. , vol.9 , pp. 744
    • Olumee, Z.1    Sadeghi, M.2    Tang, X.3    Vertes, A.4
  • 33
    • 0030047007 scopus 로고    scopus 로고
    • Use of 2,6-dihydroxyacetophenone for analysis of fragile peptides, disulphide bonding and small proteins by matrix-assisted laser desorption/ionization
    • Gorman JJ, Ferguson BL, Nguyen TB. Use of 2,6-dihydroxyacetophenone for analysis of fragile peptides, disulphide bonding and small proteins by matrix-assisted laser desorption/ionization. Rapid Commun. Mass Spectrom. 1996; 10: 529.
    • (1996) Rapid Commun. Mass Spectrom. , vol.10 , pp. 529
    • Gorman, J.J.1    Ferguson, B.L.2    Nguyen, T.B.3
  • 34
    • 0037106326 scopus 로고    scopus 로고
    • A method for detection of overoxidation of cysteines: Peroxiredoxins are oxidized in vivo at the active-site cysteine during oxidative stress
    • Wagner E, Luche S, Penna L, Chevallet M, Van Dorsselaer A, Leize-Wagner E, Rabilloud T. A method for detection of overoxidation of cysteines: peroxiredoxins are oxidized in vivo at the active-site cysteine during oxidative stress. Biochem. J. 2002; 366: 777.
    • (2002) Biochem. J. , vol.366 , pp. 777
    • Wagner, E.1    Luche, S.2    Penna, L.3    Chevallet, M.4    Van Dorsselaer, A.5    Leize-Wagner, E.6    Rabilloud, T.7
  • 35
    • 0029851666 scopus 로고    scopus 로고
    • Excess salt removal with matrix rinsing: Direct peptide profiling of neurons from marine invertebrates using matrix-assisted laser desorption/ionization time-of-flight mass spectrometry
    • Garden RW, Moroz LL, Moroz TP, Shippy SA, Sweedler JV. Excess salt removal with matrix rinsing: direct peptide profiling of neurons from marine invertebrates using matrix-assisted laser desorption/ionization time-of-flight mass spectrometry. J. Mass Spectrom. 1996; 31: 1126.
    • (1996) J. Mass Spectrom. , vol.31 , pp. 1126
    • Garden, R.W.1    Moroz, L.L.2    Moroz, T.P.3    Shippy, S.A.4    Sweedler, J.V.5
  • 36
    • 0030468684 scopus 로고    scopus 로고
    • The effect of ammonium salt and matrix in the detection of DNA by matrix-assisted laser desorption/ionization time-of-flight mass spectrometry
    • Zhu YF, Taranenko NI, Allman SL, Martin SA, Haff L, Chen CH. The effect of ammonium salt and matrix in the detection of DNA by matrix-assisted laser desorption/ionization time-of-flight mass spectrometry. Rapid Commun. Mass Spectrom. 1996; 10: 1591.
    • (1996) Rapid Commun. Mass Spectrom. , vol.10 , pp. 1591
    • Zhu, Y.F.1    Taranenko, N.I.2    Allman, S.L.3    Martin, S.A.4    Haff, L.5    Chen, C.H.6
  • 37
    • 0006532588 scopus 로고    scopus 로고
    • The MALDI mass spectra of carbosilane-based dendrimers containing up to eight fixed positive or 16 negative charges
    • Wu Z, Biemann K. The MALDI mass spectra of carbosilane-based dendrimers containing up to eight fixed positive or 16 negative charges. Int. J. Mass Spectrom. Ion Processes 1997; 165: 349.
    • (1997) Int. J. Mass Spectrom. Ion Processes , vol.165 , pp. 349
    • Wu, Z.1    Biemann, K.2
  • 38
    • 13844320727 scopus 로고    scopus 로고
    • Ordered silicon nanocavity arrays in surface-assisted desorption/ionization mass spectrometry
    • Finkel NH, Prevo BG, Velev OD, He L. Ordered silicon nanocavity arrays in surface-assisted desorption/ionization mass spectrometry. Anal. Chem. 2005; 77: 1088.
    • (2005) Anal. Chem. , vol.77 , pp. 1088
    • Finkel, N.H.1    Prevo, B.G.2    Velev, O.D.3    He, L.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.