Volumn 10, Issue 5-6, 2005, Pages 281-292

A system for ultrasound-guided computer-assisted orthopaedic surgery

Author keywords

Computer assisted orthopedic surgery; Entropy; Image registration; Image guided surgery; ITK; Mutual information; Ultrasound calibration; Ultrasound imaging; Volume reconstruction; VTK

Indexed keywords

ACCURACY; COMPUTER ASSISTED SURGERY; COMPUTER ASSISTED TOMOGRAPHY; CONFERENCE PAPER; DIAGNOSTIC IMAGING; FLUOROSCOPY; HUMAN; INTRAOPERATIVE PERIOD; ORTHOPEDIC SURGERY; PREOPERATIVE PERIOD; PRIORITY JOURNAL; STATISTICAL SIGNIFICANCE; SURGICAL TECHNIQUE; ULTRASOUND;

EID: 30944450798     PISSN: 10929088     EISSN: 10970150     Source Type: Journal    
DOI: 10.1080/10929080500390017     Document Type: Conference Paper
Times cited : (43)

References (32)
  • 4
    • 0037401152 scopus 로고    scopus 로고
    • Computer assisted orthopaedic and trauma surgery: State of the art and future perspectives
    • Schep NWL, Broeders IA, van der Werken C. Computer assisted orthopaedic and trauma surgery: state of the art and future perspectives. Injury 2003;34:299-306.
    • (2003) Injury , vol.34 , pp. 299-306
    • Schep, N.W.L.1    Broeders, I.A.2    Van Der Werken, C.3
  • 5
    • 0037783239 scopus 로고    scopus 로고
    • Computer-assisted orthopedic surgery
    • Sugano N. Computer-assisted orthopedic surgery. J Orthop Science 2003;8:442-448.
    • (2003) J Orthop Science , vol.8 , pp. 442-448
    • Sugano, N.1
  • 8
    • 0041825426 scopus 로고    scopus 로고
    • Robust registration for computer-integrated orthopedic surgery: Laboratory validation and clinical experience
    • Ma B, Ellis RE. Robust registration for computer-integrated orthopedic surgery: laboratory validation and clinical experience. Med Image Anal 2003;7:237-250.
    • (2003) Med Image Anal , vol.7 , pp. 237-250
    • Ma, B.1    Ellis, R.E.2
  • 11
    • 0038371263 scopus 로고    scopus 로고
    • Three-dimensional image registration of phantom vertebrae for image-guided surgery: A preliminary study
    • Muratore DM, Russ JH, Dawant BM, Galloway RL. Three-dimensional image registration of phantom vertebrae for image-guided surgery: a preliminary study. Comput Aided Surg 2002;7:342-352.
    • (2002) Comput Aided Surg , vol.7 , pp. 342-352
    • Muratore, D.M.1    Russ, J.H.2    Dawant, B.M.3    Galloway, R.L.4
  • 12
    • 84947727831 scopus 로고    scopus 로고
    • Percutaneous computer assisted iliosacral screwing
    • Wells WM, Colchester A, Delp S, editors. Proceedings of the First International Conference on Medical Image Computing and Computer-Assisted Intervention (MICCAI '98), October 1998, Cambridge, MA. Berlin: Springer
    • Carrat L, Tonetti J, Lavallée S, Merloz P, Pittet L, Chirossel JP. Percutaneous computer assisted iliosacral screwing. In: Wells WM, Colchester A, Delp S, editors. Proceedings of the First International Conference on Medical Image Computing and Computer-Assisted Intervention (MICCAI '98), October 1998, Cambridge, MA. Lecture Notes in Computer Science, Vol. 1496. Berlin: Springer; 1998. pp 84-91.
    • (1998) Lecture Notes in Computer Science , vol.1496 , pp. 84-91
    • Carrat, L.1    Tonetti, J.2    Lavallée, S.3    Merloz, P.4    Pittet, L.5    Chirossel, J.P.6
  • 13
    • 84945551734 scopus 로고    scopus 로고
    • Percutaneous computer assisted iliosacral screwing: Clinical validation
    • Delp S, DiGioia AM, Jaramaz B, editors. Proceedings of the 3rd International Conference on Medical Image Computing and Computer-Assisted Intervention (MICCAI 2000), October 2000, Pittsburgh, PA. Berlin: Springer
    • Carrat L, Tonetti J, Merloz P, Troccaz J. Percutaneous computer assisted iliosacral screwing: Clinical validation. In: Delp S, DiGioia AM, Jaramaz B, editors. Proceedings of the 3rd International Conference on Medical Image Computing and Computer-Assisted Intervention (MICCAI 2000), October 2000, Pittsburgh, PA. Lecture Notes in Computer Science, Vol. 1935. Berlin: Springer; 2000. pp 1229-1237.
    • (2000) Lecture Notes in Computer Science , vol.1935 , pp. 1229-1237
    • Carrat, L.1    Tonetti, J.2    Merloz, P.3    Troccaz, J.4
  • 14
    • 0035708541 scopus 로고    scopus 로고
    • Clinical results of percutaneous pelvic surgery: Computer assisted surgery using ultrasound compared to standard fluoroscopy
    • Tonetti J, Carrat L, Blendea S, Merloz P, Troccaz J, Lavallée S, Chirossel JP. Clinical results of percutaneous pelvic surgery: computer assisted surgery using ultrasound compared to standard fluoroscopy. Comput Aided Surg 2002;6:204-211.
    • (2002) Comput Aided Surg , vol.6 , pp. 204-211
    • Tonetti, J.1    Carrat, L.2    Blendea, S.3    Merloz, P.4    Troccaz, J.5    Lavallée, S.6    Chirossel, J.P.7
  • 16
    • 1242309418 scopus 로고    scopus 로고
    • Ultrasound registration of the bone surface for surgical navigation
    • Amin DV, Kanade T, DiGioia AM, Jaramaz B. Ultrasound registration of the bone surface for surgical navigation. Comput Aided Surg 2003;8(1):1-16.
    • (2003) Comput Aided Surg , vol.8 , Issue.1 , pp. 1-16
    • Amin, D.V.1    Kanade, T.2    DiGioia, A.M.3    Jaramaz, B.4
  • 19
    • 0043028206 scopus 로고    scopus 로고
    • Mutual information based registration of medical images: A survey
    • Pluim J, Maintz JB, Viergever MA. Mutual information based registration of medical images: a survey. IEEE Trans Med Imaging 2003;22(8):986-1004.
    • (2003) IEEE Trans Med Imaging , vol.22 , Issue.8 , pp. 986-1004
    • Pluim, J.1    Maintz, J.B.2    Viergever, M.A.3
  • 22
    • 77956647540 scopus 로고    scopus 로고
    • A hybrid method for registration of interventional CT and ultrasound images
    • Lemke HU, Vannier MW, Inamura K, Farman AG, doi K, Reiber JHC, editors. Computer assisted radiology and surgery. Chicago, June
    • Berg J, Kruecker J, Schulz H, Meetz K, Sabczynski J. A hybrid method for registration of interventional CT and ultrasound images. In: Lemke HU, Vannier MW, Inamura K, Farman AG, doi K, Reiber JHC, editors. Computer assisted radiology and surgery. Proceedings of the 18th International Congress and Exhibition (CARS 2004), Chicago, June 2004, IL. Amsterdam: Elsevier; 2004. pp 492-497.
    • (2004) Proceedings of the 18th International Congress and Exhibition (CARS 2004) , vol.2004 , pp. 492-497
    • Berg, J.1    Kruecker, J.2    Schulz, H.3    Meetz, K.4    Sabczynski, J.5
  • 23
    • 0033103209 scopus 로고    scopus 로고
    • Semiautomatic registration of volumetric ultrasound scans
    • Meyer CR, Boes JL, Kim B. Semiautomatic registration of volumetric ultrasound scans. Ultrasound Med Biol 1999;25:339-347.
    • (1999) Ultrasound Med Biol , vol.25 , pp. 339-347
    • Meyer, C.R.1    Boes, J.L.2    Kim, B.3
  • 25
    • 0003547470 scopus 로고    scopus 로고
    • Unified modeling language user guide (object technology)
    • Redwood City, CA: Addison-Wesley Professional
    • Booch G, Jacobson I, Rumbaugh J. Unified modeling language user guide (object technology). The Addison-Wesley Object Technology Series. Redwood City, CA: Addison-Wesley Professional; 1998.
    • (1998) The Addison-Wesley Object Technology Series
    • Booch, G.1    Jacobson, I.2    Rumbaugh, J.3
  • 26
    • 13644249894 scopus 로고    scopus 로고
    • A review of calibration techniques for freehand 3-D ultrasound systems
    • Mercier L, Lango T, Lindseth F, Collins LD. A review of calibration techniques for freehand 3-D ultrasound systems. Ultrasound Med Biol 2005;31(2):143-165.
    • (2005) Ultrasound Med Biol , vol.31 , Issue.2 , pp. 143-165
    • Mercier, L.1    Lango, T.2    Lindseth, F.3    Collins, L.D.4
  • 27
    • 0034804115 scopus 로고    scopus 로고
    • A fast calibration method for 3D tracking of ultrasound images using a spatial localizer
    • Pagoulatos N, Haynor DR, Kim Y. A fast calibration method for 3D tracking of ultrasound images using a spatial localizer. Ultrasound Med Biol 2000;27:1219-1229.
    • (2000) Ultrasound Med Biol , vol.27 , pp. 1219-1229
    • Pagoulatos, N.1    Haynor, D.R.2    Kim, Y.3
  • 31
    • 0030088712 scopus 로고    scopus 로고
    • Multi-modal volume registration by maximization of mutual information
    • Wells W, Viola P, Atsumi H, Nakajima S, Kikinis R. Multi-modal volume registration by maximization of mutual information. Med Image Anal 1996;1:35-51.
    • (1996) Med Image Anal , vol.1 , pp. 35-51
    • Wells, W.1    Viola, P.2    Atsumi, H.3    Nakajima, S.4    Kikinis, R.5
  • 32
    • 0000070850 scopus 로고    scopus 로고
    • Optimization of mutual information for multiresolution image registration
    • Thevenaz P, Unser M. Optimization of mutual information for multiresolution image registration. IEEE Trans Image Process 2000;9(12):2083-2099.
    • (2000) IEEE Trans Image Process , vol.9 , Issue.12 , pp. 2083-2099
    • Thevenaz, P.1    Unser, M.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.