메뉴 건너뛰기




Volumn 126, Issue 26, 2004, Pages 8108-8109

EXAFS spectroscopic evidence for an Fe=O unit in the Fe(IV) intermediate observed during oxygen activation by taurine:α-ketoglutarate dioxygenase

Author keywords

[No Author keywords available]

Indexed keywords

IRON; OXYGEN; OXYGENASE; TAURINE ALPHA KETOGLUTARATE DIOXYGENASE; UNCLASSIFIED DRUG;

EID: 3042770458     PISSN: 00027863     EISSN: None     Source Type: Journal    
DOI: 10.1021/ja048255q     Document Type: Article
Times cited : (273)

References (17)
  • 3
    • 3042704952 scopus 로고    scopus 로고
    • note
    • Abbreviations used: α-KG: α-ketoglutarate; TauD: taurine: α-ketoglutarate dioxygenase; XAS: X-ray absorption spectroscopy; XANES: X-ray absorption near edge spectrum; EXAFS: extended X-ray absorption fine structure; FT: Fourier transform.
  • 8
    • 15844409181 scopus 로고    scopus 로고
    • 2. 2 was prepared under identical conditions, except that the reaction time was 20 ms and oxygen was excluded. Samples were packed into a sample holder that can be used for Mössbauer and XAS spectroscopies. Mössbauer experiments were carried out as described in reference (5). XAS data were collected at the National Synchrotron Light Source on Beamline X9B. Samples were maintained at T = 14 K with a displex cryostat and the Fe Kα fluorescence was detected with a Canberra 13 element Ge detector. The general protocols for data reduction and curve fitting were described in Riggs-Gelasco et al., J. Am. Chem. Soc. 1996, 118, 2387-2399 and minor modifications are described in the Supporting Information.
    • (1996) J. Am. Chem. Soc. , vol.118 , pp. 2387-2399
    • Riggs-Gelasco1
  • 12
    • 3042744483 scopus 로고    scopus 로고
    • note
    • Single 45-minute scans were collected at six different sample positions and were averaged for the intermediate edge spectrum shown. Progressive photoreduction both in the edge position and in the intensity of the preedge feature is apparent after several scans on a single spot as shown in Figure S3.
  • 16
    • 3042743031 scopus 로고    scopus 로고
    • note
    • The spectrum of 1 shown is the average of 20 first and second scans of several replicate samples. Similar results are obtained if all scans, including scans after 10 h of collection, are averaged for a single sample. Also, if first and second scans are excluded from the average, the short Fe-O distance can still be detected, despite the apparent photoreduction in these scans.


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.