메뉴 건너뛰기




Volumn 45, Issue 6, 2004, Pages 1846-1853

Psychophysical measurement of neural adaptation abnormalities magnocellular and parvocellular pathways in glaucoma

Author keywords

[No Author keywords available]

Indexed keywords

ADAPTATION; ADULT; AGED; ARTICLE; CLINICAL ARTICLE; CONTRAST SENSITIVITY; CONTROLLED STUDY; DEVICE; GLAUCOMA; HUMAN; LUMINANCE; MAGNOCELLULAR NERVE CELL; MEASUREMENT; OPEN ANGLE GLAUCOMA; PARVOCELLULAR NERVE CELL; PRIORITY JOURNAL; PSYCHOPHYSIOLOGY; RETINA FOVEA; RETINA GANGLION CELL; STIMULUS; VISUAL FIELD; DIFFERENTIAL THRESHOLD; METHODOLOGY; PATHOPHYSIOLOGY; PERIMETRY; PHYSIOLOGY; PSYCHOPHYSICS; VISUAL DISORDER; VISUAL SYSTEM;

EID: 3042631215     PISSN: 01460404     EISSN: None     Source Type: Journal    
DOI: 10.1167/iovs.03-1225     Document Type: Article
Times cited : (60)

References (42)
  • 1
    • 0027209047 scopus 로고
    • Blue-on-yellow perimetry can predict the development of glaucomatous visual field loss
    • Johnson CA, Adams AJ, Casson EJ, Brandt JD. Blue-on-yellow perimetry can predict the development of glaucomatous visual field loss. Arch Ophthalmol. 1993;111:645-650.
    • (1993) Arch Ophthalmol , vol.111 , pp. 645-650
    • Johnson, C.A.1    Adams, A.J.2    Casson, E.J.3    Brandt, J.D.4
  • 2
    • 0027161746 scopus 로고
    • Progression of early glaucomatous visual field loss for blue-on-yellow and standard white-on-white automated perimetry
    • Johnson CA, Adams AJ, Casson EJ, Brandt JD. Progression of early glaucomatous visual field loss for blue-on-yellow and standard white-on-white automated perimetry. Arch Ophthalmol. 1993; 111:651-656.
    • (1993) Arch Ophthalmol , vol.111 , pp. 651-656
    • Johnson, C.A.1    Adams, A.J.2    Casson, E.J.3    Brandt, J.D.4
  • 3
    • 0031058190 scopus 로고    scopus 로고
    • Screening for glaucomatous visual field loss with frequency doubling perimetry
    • Johnson CA, Samuels SJ. Screening for glaucomatous visual field loss with frequency doubling perimetry. Invest Ophthalmol Vis Sci. 1997;38:413-425.
    • (1997) Invest Ophthalmol Vis Sci , vol.38 , pp. 413-425
    • Johnson, C.A.1    Samuels, S.J.2
  • 4
    • 0027643378 scopus 로고
    • Longitudinal comparison of temporal-modulation perimetry with white-on-white and blue-on-yellow perimetry in ocular hypertension and early glaucoma
    • Casson EJ, Johnson CA, Shapiro LR. Longitudinal comparison of temporal-modulation perimetry with white-on-white and blue-on-yellow perimetry in ocular hypertension and early glaucoma. J Opt Soc Am A. 1993;10:1792-1806.
    • (1993) J Opt Soc Am A , vol.10 , pp. 1792-1806
    • Casson, E.J.1    Johnson, C.A.2    Shapiro, L.R.3
  • 5
    • 0030931708 scopus 로고    scopus 로고
    • Short-wavelength automated perimetry and motion automated perimetry in patients with glaucoma
    • Sample PA, Bosworth CF, Weinreb RN. Short-wavelength automated perimetry and motion automated perimetry in patients with glaucoma. Arch Ophthalmol. 1997;115:1129-1133.
    • (1997) Arch Ophthalmol , vol.115 , pp. 1129-1133
    • Sample, P.A.1    Bosworth, C.F.2    Weinreb, R.N.3
  • 7
    • 0023865522 scopus 로고
    • Chronic human glaucoma causing selectively greater loss of large optic nerve fibers
    • Quigley HA, Dunkelberger GR, Green WR. Chronic human glaucoma causing selectively greater loss of large optic nerve fibers. Ophthalmology. 1988;95:357-363.
    • (1988) Ophthalmology , vol.95 , pp. 357-363
    • Quigley, H.A.1    Dunkelberger, G.R.2    Green, W.R.3
  • 9
    • 0027688673 scopus 로고
    • Morphology of a small-field bistratified ganglion cell type in the macaque and human retina
    • Dacey DM. Morphology of a small-field bistratified ganglion cell type in the macaque and human retina. Vis Neurosci. 1993;10: 1081-1098.
    • (1993) Vis Neurosci , vol.10 , pp. 1081-1098
    • Dacey, D.M.1
  • 10
    • 0026713178 scopus 로고
    • Dendritic field size and morphology of midget and parasol ganglion cells of the human retina
    • Dacey DM, Petersen MR. Dendritic field size and morphology of midget and parasol ganglion cells of the human retina. Proc Nat Acad Sci USA. 1992;89:9666-9670.
    • (1992) Proc Nat Acad Sci USA , vol.89 , pp. 9666-9670
    • Dacey, D.M.1    Petersen, M.R.2
  • 11
    • 0036022762 scopus 로고    scopus 로고
    • Retinal ganglion cell shrinkage in glaucoma
    • Morgan JE. Retinal ganglion cell shrinkage in glaucoma. J Glaucoma. 2002;11:365-370.
    • (2002) J Glaucoma , vol.11 , pp. 365-370
    • Morgan, J.E.1
  • 13
    • 0343851600 scopus 로고    scopus 로고
    • Loss of neurons in magnocellular and parvocellular layers of the lateral geniculate nucleus in glaucoma
    • Yucel YH, Zhang Q, Gupta N, Kaufman PL, Weinreb RN. Loss of neurons in magnocellular and parvocellular layers of the lateral geniculate nucleus in glaucoma. Arch Ophthalmol. 2000;118:378-384.
    • (2000) Arch Ophthalmol , vol.118 , pp. 378-384
    • Yucel, Y.H.1    Zhang, Q.2    Gupta, N.3    Kaufman, P.L.4    Weinreb, R.N.5
  • 14
    • 0028307409 scopus 로고
    • Selective versus nonselective losses in glaucoma
    • Johnson CA. Selective versus nonselective losses in glaucoma. J Glaucoma. 1994;3:S32-S44.
    • (1994) J Glaucoma , vol.3
    • Johnson, C.A.1
  • 15
    • 0025011140 scopus 로고
    • Topography of ganglion cells in human retina
    • Curcio CA, Allen KA. Topography of ganglion cells in human retina. J Comp Neurol. 1990;300:5-25.
    • (1990) J Comp Neurol , vol.300 , pp. 5-25
    • Curcio, C.A.1    Allen, K.A.2
  • 16
    • 17944390776 scopus 로고    scopus 로고
    • Effects of retinal ganglion cell loss on magno-, parvo- and koniocellular pathways in the lateral geniculate nucleus and visual cortex in glaucoma
    • Yucel YH, Zhang Q, Weinreb RN, Kaufman PL, Gupta N. Effects of retinal ganglion cell loss on magno-, parvo- and koniocellular pathways in the lateral geniculate nucleus and visual cortex in glaucoma. Prog Retin Eye Res. 2003;22:465-481.
    • (2003) Prog Retin Eye Res , vol.22 , pp. 465-481
    • Yucel, Y.H.1    Zhang, Q.2    Weinreb, R.N.3    Kaufman, P.L.4    Gupta, N.5
  • 19
    • 0032927961 scopus 로고    scopus 로고
    • Comparison of conventional and high-pass resolution perimetry in a prospective study of patients with glaucoma and healthy controls
    • Chauhan BC, House PH, McCormick TA, LeBlanc RP. Comparison of conventional and high-pass resolution perimetry in a prospective study of patients with glaucoma and healthy controls. Arch Ophthalmol. 1999;117:24-33.
    • (1999) Arch Ophthalmol , vol.117 , pp. 24-33
    • Chauhan, B.C.1    House, P.H.2    McCormick, T.A.3    LeBlanc, R.P.4
  • 20
    • 0142139217 scopus 로고    scopus 로고
    • Peripheral resolution for achromatic and SWS gratings in early to moderate glaucoma and the implications for selective ganglion cell density loss
    • Beirne RO, Logan JFJ, Zlatkova MB, et al. Peripheral resolution for achromatic and SWS gratings in early to moderate glaucoma and the implications for selective ganglion cell density loss. Invest Ophthalmol Vis Sci. 2003;44:4780-4786.
    • (2003) Invest Ophthalmol Vis Sci , vol.44 , pp. 4780-4786
    • Beirne, R.O.1    Logan, J.F.J.2    Zlatkova, M.B.3
  • 24
    • 0031225977 scopus 로고    scopus 로고
    • Psychophysical signatures associated with magnocellular and parvocellular pathway contrast gain
    • Pokorny J, Smith VC. Psychophysical signatures associated with magnocellular and parvocellular pathway contrast gain. Vision Res. 1997;14:2477-2486.
    • (1997) Vision Res , vol.14 , pp. 2477-2486
    • Pokorny, J.1    Smith, V.C.2
  • 25
    • 0037246890 scopus 로고    scopus 로고
    • Contrast-processing dysfunction in both magnocellular and parvocellular pathways in migraineurs both with and without aura
    • McKendrick AM, Badcock DR. Contrast-processing dysfunction in both magnocellular and parvocellular pathways in migraineurs both with and without aura. Invest Ophthalmol Vis Sci. 2003;44: 442-448.
    • (2003) Invest Ophthalmol Vis Sci , vol.44 , pp. 442-448
    • McKendrick, A.M.1    Badcock, D.R.2
  • 26
    • 0030010989 scopus 로고    scopus 로고
    • Undersampling produces non-veridical motion perception, but not necessarily motion reversal in peripheral vision
    • Wang Y, Thibos LN, Bradley A. Undersampling produces non-veridical motion perception, but not necessarily motion reversal in peripheral vision. Vision Res. 1996;36:1737-1744.
    • (1996) Vision Res , vol.36 , pp. 1737-1744
    • Wang, Y.1    Thibos, L.N.2    Bradley, A.3
  • 27
    • 0025368583 scopus 로고
    • The Opticom M-600: A new LED automated perimeter
    • Vingrys AJ, Helfrich KA. The Opticom M-600: a new LED automated perimeter. Clin Exp Optom. 1990;1:10-20.
    • (1990) Clin Exp Optom , vol.1 , pp. 10-20
    • Vingrys, A.J.1    Helfrich, K.A.2
  • 28
    • 0038018330 scopus 로고    scopus 로고
    • A comparison of perimetric results with the Medmont and Humphrey perimeters
    • Landers J, Sharma A, Goldberg I, Graham S. A comparison of perimetric results with the Medmont and Humphrey perimeters. Br J Ophthalmol. 2003;87:690-694.
    • (2003) Br J Ophthalmol , vol.87 , pp. 690-694
    • Landers, J.1    Sharma, A.2    Goldberg, I.3    Graham, S.4
  • 29
    • 0007993505 scopus 로고
    • Sequential estimation of points on a psychometric function
    • Wetherill G, Levitt H. Sequential estimation of points on a psychometric function. Br J Math Stat Psychol. 1965;18:1-10.
    • (1965) Br J Math Stat Psychol , vol.18 , pp. 1-10
    • Wetherill, G.1    Levitt, H.2
  • 31
    • 0344190968 scopus 로고
    • The primate retina contains two types of ganglion cells, with high and low contrast sensitivity
    • Kaplan E, Shapley RM. The primate retina contains two types of ganglion cells, with high and low contrast sensitivity. Proc Natl Acad Sci USA. 1986;83:2755-2757.
    • (1986) Proc Natl Acad Sci USA , vol.83 , pp. 2755-2757
    • Kaplan, E.1    Shapley, R.M.2
  • 32
    • 0037385106 scopus 로고    scopus 로고
    • Comparison of contrast sensitivity, visual acuity, and Humphrey visual field testing in patients with glaucoma
    • Hawkins AS, Szlyk JP, Ardickas Z, Alexander KR, Wilensky JT. Comparison of contrast sensitivity, visual acuity, and Humphrey visual field testing in patients with glaucoma. J Glaucoma. 2003; 12:134-138.
    • (2003) J Glaucoma , vol.12 , pp. 134-138
    • Hawkins, A.S.1    Szlyk, J.P.2    Ardickas, Z.3    Alexander, K.R.4    Wilensky, J.T.5
  • 33
    • 0034000981 scopus 로고    scopus 로고
    • Frequency doubling technology perimetry for detection of glaucomatous field loss
    • Cello KE, Nelson-Quigg JM, Johnson CA. Frequency doubling technology perimetry for detection of glaucomatous field loss. Am J Ophthalmol. 2000;129:314-322.
    • (2000) Am J Ophthalmol , vol.129 , pp. 314-322
    • Cello, K.E.1    Nelson-Quigg, J.M.2    Johnson, C.A.3
  • 34
    • 0027243394 scopus 로고
    • Vernier thresholds and alignment bias in control, suspect, and glaucomatous eyes
    • Piltz J, Swindale NV, Drance SM. Vernier thresholds and alignment bias in control, suspect, and glaucomatous eyes. J Glaucoma. 1993;2:87-95.
    • (1993) J Glaucoma , vol.2 , pp. 87-95
    • Piltz, J.1    Swindale, N.V.2    Drance, S.M.3
  • 36
    • 0034995932 scopus 로고    scopus 로고
    • Pulse and steady-pedestal contrast discrimination: Effect of spatial parameters
    • Smith VC, Sun VC, Pokorny J. Pulse and steady-pedestal contrast discrimination: effect of spatial parameters. Vision Res. 2001;41: 2079-2088.
    • (2001) Vision Res , vol.41 , pp. 2079-2088
    • Smith, V.C.1    Sun, V.C.2    Pokorny, J.3
  • 37
    • 0038648330 scopus 로고    scopus 로고
    • Spatial frequency processing in inferred PC- and MC-pathways
    • Leonova A, Pokorny J, Smith VC. Spatial frequency processing in inferred PC- and MC-pathways. Vision Res. 2003;43:2133-2139.
    • (2003) Vision Res , vol.43 , pp. 2133-2139
    • Leonova, A.1    Pokorny, J.2    Smith, V.C.3
  • 38
    • 0141633564 scopus 로고    scopus 로고
    • Patterns of glaucomatous visual field defects in an older population: The Blue Mountains Eye Study
    • Lee AJ, Wang JJ, Rochtchina E, Healey P, Chia EM, Mitchell P. Patterns of glaucomatous visual field defects in an older population: the Blue Mountains Eye Study. Clin Exp Ophthalmol. 2003;31:331-335.
    • (2003) Clin Exp Ophthalmol , vol.31 , pp. 331-335
    • Lee, A.J.1    Wang, J.J.2    Rochtchina, E.3    Healey, P.4    Chia, E.M.5    Mitchell, P.6
  • 39
    • 0022493414 scopus 로고
    • Functions of the ON and OFF channels of the visual system
    • Schiller PH, Sandell JH, Maunsell JH. Functions of the ON and OFF channels of the visual system. Nature. 1986;322:824-825.
    • (1986) Nature , vol.322 , pp. 824-825
    • Schiller, P.H.1    Sandell, J.H.2    Maunsell, J.H.3
  • 40
    • 0024440419 scopus 로고
    • Sawtooth contrast sensitivity: Decrements have the edge
    • Bowen RW, Pokorny J, Smith VC. Sawtooth contrast sensitivity: decrements have the edge. Vision Res. 1989;29:1501-1509.
    • (1989) Vision Res , vol.29 , pp. 1501-1509
    • Bowen, R.W.1    Pokorny, J.2    Smith, V.C.3
  • 41
    • 0026584813 scopus 로고
    • Different spatial tunings for ON and OFF pathway stimulation
    • Tyler CW, Chan H, Liu L. Different spatial tunings for ON and OFF pathway stimulation. Ophthalmic Physiol Opt. 1992;12:233-240.
    • (1992) Ophthalmic Physiol Opt , vol.12 , pp. 233-240
    • Tyler, C.W.1    Chan, H.2    Liu, L.3
  • 42
    • 0036674272 scopus 로고    scopus 로고
    • Adaptation of spatiotemporal mechanisms by increment and decrement stimuli
    • Purkiss TJ, DeMarco PJJ. Adaptation of spatiotemporal mechanisms by increment and decrement stimuli. J Opt Soc Am A. 2002;19:1475-1483.
    • (2002) J Opt Soc Am A , vol.19 , pp. 1475-1483
    • Purkiss, T.J.1    DeMarco, P.J.J.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.