메뉴 건너뛰기




Volumn 40, Issue 10, 1999, Pages 2242-2250

Ganglion cell losses underlying visual field defects from experimental glaucoma

Author keywords

[No Author keywords available]

Indexed keywords

ANIMAL EXPERIMENT; ANIMAL MODEL; ANIMAL TISSUE; ARGON LASER; ARTICLE; CELL LOSS; CONTROLLED STUDY; GLAUCOMA; MALE; NONHUMAN; PERIMETRY; PRIORITY JOURNAL; RETINA GANGLION CELL; RHESUS MONKEY; TRABECULAR MESHWORK; VISUAL FIELD DEFECT; VISUAL STIMULATION; VISUAL THRESHOLD;

EID: 0344329377     PISSN: 01460404     EISSN: None     Source Type: Journal    
DOI: None     Document Type: Article
Times cited : (438)

References (57)
  • 2
    • 0030023469 scopus 로고    scopus 로고
    • Standardizing the measurement of visual fields for clinical research
    • Johnson CA. Standardizing the measurement of visual fields for clinical research. Ophthalmology 1996;103:186-189.
    • (1996) Ophthalmology , vol.103 , pp. 186-189
    • Johnson, C.A.1
  • 3
    • 0026280173 scopus 로고
    • Diagnosis and management of primary open-angle glaucoma
    • Classe JG, ed. Norwalk: Appleton & Lange
    • Alexander LJ. Diagnosis and management of primary open-angle glaucoma. In: Classe JG, ed. Optometry Clinics. Norwalk: Appleton & Lange, 1991;1:19-102.
    • (1991) Optometry Clinics , vol.1 , pp. 19-102
    • Alexander, L.J.1
  • 4
    • 0027399771 scopus 로고
    • Open-angle glaucoma
    • Quigley HA. Open-angle glaucoma. N Engl J Med. 1993;328:1097-1106.
    • (1993) N Engl J Med. , vol.328 , pp. 1097-1106
    • Quigley, H.A.1
  • 5
    • 0000342180 scopus 로고    scopus 로고
    • Primary open angle glaucoma
    • Epstein DL, Allingham RR, Schuman JS, eds. Baltimore: Williams & Wilkins;
    • Epstein DL. Primary open angle glaucoma. In: Epstein DL, Allingham RR, Schuman JS, eds. Chandler and Grant's Glaucoma. 4th ed. Baltimore: Williams & Wilkins; 1997:183-198.
    • (1997) Chandler and Grant's Glaucoma. 4th Ed. , pp. 183-198
    • Epstein, D.L.1
  • 7
    • 0000139368 scopus 로고
    • A package for the statistical analysis of visual fields
    • Heijl A, Lindgren G, Olsson J. A package for the statistical analysis of visual fields. Doc Ophthalmol. 1987;49:153-168.
    • (1987) Doc Ophthalmol. , vol.49 , pp. 153-168
    • Heijl, A.1    Lindgren, G.2    Olsson, J.3
  • 8
    • 0000139365 scopus 로고
    • Reliability parameters in computerized perimetry
    • Heijl A, Lindgren G, Olsson J. Reliability parameters in computerized perimetry. Doc Ophthalmol. 1987;49:595-600.
    • (1987) Doc Ophthalmol. , vol.49 , pp. 595-600
    • Heijl, A.1    Lindgren, G.2    Olsson, J.3
  • 9
    • 0009696251 scopus 로고
    • The value of visual field indexes in screening and threshold testing of glaucoma
    • Wood JM, Bruce AS. The value of visual field indexes in screening and threshold testing of glaucoma. Glaucoma. 1993;15:140-146.
    • (1993) Glaucoma , vol.15 , pp. 140-146
    • Wood, J.M.1    Bruce, A.S.2
  • 10
    • 0030013973 scopus 로고    scopus 로고
    • Analysis of progressive change in automated visual fields in glaucoma
    • Smith SD, Katz J, Quigley HA. Analysis of progressive change in automated visual fields in glaucoma. Invest Ophthalmol Vis Sci. 1996;37:1419-1428.
    • (1996) Invest Ophthalmol Vis Sci. , vol.37 , pp. 1419-1428
    • Smith, S.D.1    Katz, J.2    Quigley, H.A.3
  • 11
    • 0026410735 scopus 로고
    • Comparison of analytic algorithms for detecting visual field loss
    • Katz J, Sommer A, Gaasterland DE, Anderson DR. Comparison of analytic algorithms for detecting visual field loss. Arch Ophthalmol. 1991;109:1684-1689.
    • (1991) Arch Ophthalmol. , vol.109 , pp. 1684-1689
    • Katz, J.1    Sommer, A.2    Gaasterland, D.E.3    Anderson, D.R.4
  • 12
    • 0026717105 scopus 로고
    • Glaucoma hemifield test
    • Asman P, Heijl A. Glaucoma hemifield test. Arch Ophthalmol. 1992;110:812-819.
    • (1992) Arch Ophthalmol. , vol.110 , pp. 812-819
    • Asman, P.1    Heijl, A.2
  • 13
    • 0026708189 scopus 로고
    • Evaluation of methods for automated hemifield analysis in perimetry
    • Asman P, Heijl A. Evaluation of methods for automated hemifield analysis in perimetry. Arch Ophthalmol. 1992;110:820-826.
    • (1992) Arch Ophthalmol. , vol.110 , pp. 820-826
    • Asman, P.1    Heijl, A.2
  • 14
    • 0020042426 scopus 로고
    • Optic nerve damage in human glaucoma, III: Quantitative correlation of nerve fiber loss and visual field defect in glaucoma, ischemic neuropathy, papilledema, and toxic neuropathy
    • Quigley HA, Addicks EM, Green WR. Optic nerve damage in human glaucoma, III: quantitative correlation of nerve fiber loss and visual field defect in glaucoma, ischemic neuropathy, papilledema, and toxic neuropathy. Arch Ophthalmol. 1982;100:136-146.
    • (1982) Arch Ophthalmol. , vol.100 , pp. 136-146
    • Quigley, H.A.1    Addicks, E.M.2    Green, W.R.3
  • 15
    • 0009731424 scopus 로고
    • The physiological basis for perimetry
    • Drance SM, Anderson DR, eds. Orlando: Grune & Stratton;
    • Tate GW. The physiological basis for perimetry. In: Drance SM, Anderson DR, eds. Automatic Perimetry in Glaucoma: A Practical Guide. Orlando: Grune & Stratton; 1985:1-28.
    • (1985) Automatic Perimetry in Glaucoma: A Practical Guide , pp. 1-28
    • Tate, G.W.1
  • 16
    • 0027324565 scopus 로고
    • High-pass resolution perimetry
    • Frisen L. High-pass resolution perimetry. Doc Ophthalmol. 1993; 83:1-25.
    • (1993) Doc Ophthalmol. , vol.83 , pp. 1-25
    • Frisen, L.1
  • 17
    • 0027135063 scopus 로고
    • Comparison of spatial thresholds and intensity thresholds in glaucoma
    • Bartz-Schmidt KU, Weber J. Comparison of spatial thresholds and intensity thresholds in glaucoma. Int Ophthalmol. 1993;17:171-178.
    • (1993) Int Ophthalmol. , vol.17 , pp. 171-178
    • Bartz-Schmidt, K.U.1    Weber, J.2
  • 18
    • 0024402107 scopus 로고
    • Retinal ganglion cell atrophy correlated with automated perimetry in human eyes with glaucoma
    • Quigley HA, Dunlelberger GR, Green WR. Retinal ganglion cell atrophy correlated with automated perimetry in human eyes with glaucoma. Am J Ophthalmol. 1989;107:453-464.
    • (1989) Am J Ophthalmol. , vol.107 , pp. 453-464
    • Quigley, H.A.1    Dunlelberger, G.R.2    Green, W.R.3
  • 19
    • 0016243562 scopus 로고
    • Experimental glaucoma in the rhesus monkey
    • Gaasterland DE, Kupfer C. Experimental glaucoma in the rhesus monkey. Invest Ophthalmol. 1974;13:455-457.
    • (1974) Invest Ophthalmol. , vol.13 , pp. 455-457
    • Gaasterland, D.E.1    Kupfer, C.2
  • 20
    • 0021747124 scopus 로고
    • Laser-induced primate glaucoma, I: Progression of cupping
    • Pederson JE, Gaasterland DE. Laser-induced primate glaucoma, I: progression of cupping. Arch Ophthalmol. 1984;102:1689-1692.
    • (1984) Arch Ophthalmol. , vol.102 , pp. 1689-1692
    • Pederson, J.E.1    Gaasterland, D.E.2
  • 21
    • 0020619743 scopus 로고
    • Laser energy levels for trabecular meshwork damage in the primate eye
    • Quigley HA, Holman RM. Laser energy levels for trabecular meshwork damage in the primate eye. Invest Ophthalmol Vis Sci. 1987;24:1305-1307.
    • (1987) Invest Ophthalmol Vis Sci. , vol.24 , pp. 1305-1307
    • Quigley, H.A.1    Holman, R.M.2
  • 22
    • 0031473438 scopus 로고    scopus 로고
    • Experimental glaucoma: Perimetric field defects and intraocular pressure
    • Harwerth RS, Smith EL, DeSantis L. Experimental glaucoma: perimetric field defects and intraocular pressure. J Glaucoma. 1997; 6:390-401.
    • (1997) J Glaucoma , vol.6 , pp. 390-401
    • Harwerth, R.S.1    Smith, E.L.2    DeSantis, L.3
  • 26
    • 0029908754 scopus 로고    scopus 로고
    • Retinal ganglion cell death in glaucoma: The how, the why, and the maybe
    • Nickells RW. Retinal ganglion cell death in glaucoma: the how, the why, and the maybe. J Glaucoma. 1996;5:345-356.
    • (1996) J Glaucoma , vol.5 , pp. 345-356
    • Nickells, R.W.1
  • 28
    • 0032773751 scopus 로고    scopus 로고
    • Progressive visual field defects from experimental glaucoma: Measurements with white and colored stimuli
    • In press
    • Harwerth RS, Smith EL, Chandler M. Progressive visual field defects from experimental glaucoma: measurements with white and colored stimuli. Optom Vis Sci. In press.
    • Optom Vis Sci.
    • Harwerth, R.S.1    Smith, E.L.2    Chandler, M.3
  • 30
    • 0025187717 scopus 로고
    • Color perimetry for assessment of primary open-angle glaucoma
    • Sample PA, Weinreb RN. Color perimetry for assessment of primary open-angle glaucoma. Invest Ophthalmol Vis Sci. 1990;31: 1869-1875.
    • (1990) Invest Ophthalmol Vis Sci. , vol.31 , pp. 1869-1875
    • Sample, P.A.1    Weinreb, R.N.2
  • 31
    • 0027209047 scopus 로고
    • Blue-on-yellow perimetry can predict the development of glaucomatous visual field loss
    • Johnson CA, Adams AJ, Casson EJ, Brandt JD. Blue-on-yellow perimetry can predict the development of glaucomatous visual field loss. Arch Ophthalmol. 1993;111:645-650.
    • (1993) Arch Ophthalmol. , vol.111 , pp. 645-650
    • Johnson, C.A.1    Adams, A.J.2    Casson, E.J.3    Brandt, J.D.4
  • 33
    • 0029757405 scopus 로고    scopus 로고
    • Diagnostic value of short-wavelength automated perimetry
    • Johnson CA. Diagnostic value of short-wavelength automated perimetry. Curr Opin Ophthalmol. 1996;7:54-58.
    • (1996) Curr Opin Ophthalmol. , vol.7 , pp. 54-58
    • Johnson, C.A.1
  • 34
    • 0030832503 scopus 로고    scopus 로고
    • Responses to chromatic and luminance contrast in glaucoma: A psychophysical and electrophysiological study
    • Porciatti V, Di Bartolo E, Nardi MM, Fiorentini A. Responses to chromatic and luminance contrast in glaucoma: a psychophysical and electrophysiological study. Vision Res. 1997;37:1975-1987.
    • (1997) Vision Res. , vol.37 , pp. 1975-1987
    • Porciatti, V.1    Di Bartolo, E.2    Nardi, M.M.3    Fiorentini, A.4
  • 35
    • 0029063375 scopus 로고
    • The Glenn A. Fry Award Lecture: Early losses of visual function in glaucoma
    • Johnson CA. The Glenn A. Fry Award Lecture: early losses of visual function in glaucoma. Optom Vis Sci. 1995;72:359-370.
    • (1995) Optom Vis Sci. , vol.72 , pp. 359-370
    • Johnson, C.A.1
  • 36
    • 0002476645 scopus 로고    scopus 로고
    • Is early damage in glaucoma selective for a particular cell type or pathway?
    • Wall M, Heijl A, eds. Amsterdam: Kugler Publications
    • Lynch S, Johnson CA, Demirel S. Is early damage in glaucoma selective for a particular cell type or pathway? In: Wall M, Heijl A, eds. Perimetry Update 1996/1997. Amsterdam: Kugler Publications; 1997:253-261.
    • (1997) Perimetry Update 1996/1997 , pp. 253-261
    • Lynch, S.1    Johnson, C.A.2    Demirel, S.3
  • 37
    • 0002568754 scopus 로고    scopus 로고
    • Contrast sensitivity perimetry: Investigations with degenerate gratings
    • Wall M, Heijl A, eds. Amsterdam: Kugler Publications
    • Harwerth RS, Smith EL. Contrast sensitivity perimetry: investigations with degenerate gratings. In: Wall M, Heijl A, eds. Perimetry Update 1996/1997. Amsterdam: Kugler Publications; 1997:3-12.
    • (1997) Perimetry Update 1996/1997 , pp. 3-12
    • Harwerth, R.S.1    Smith, E.L.2
  • 41
    • 0025095732 scopus 로고
    • Retinal ganglion cell density and cortical magnification factor in the primate
    • Wassle H, Grunert U, Rohrenbeck J, Boycott BB. Retinal ganglion cell density and cortical magnification factor in the primate. Vision Res. 1990;30:1897-1911.
    • (1990) Vision Res. , vol.30 , pp. 1897-1911
    • Wassle, H.1    Grunert, U.2    Rohrenbeck, J.3    Boycott, B.B.4
  • 42
    • 0030027515 scopus 로고    scopus 로고
    • The scotopic electroretinogram of macaque after retinal ganglion cell loss from experimental glaucoma
    • Frishman LJ, Shen FF, Du L, et al. The scotopic electroretinogram of macaque after retinal ganglion cell loss from experimental glaucoma. Invest Ophthalmol Vis Sci. 1996;37:125-141.
    • (1996) Invest Ophthalmol Vis Sci. , vol.37 , pp. 125-141
    • Frishman, L.J.1    Shen, F.F.2    Du, L.3
  • 43
    • 84914639435 scopus 로고
    • Estimation of nuclear population from microtome sections
    • Abercrombie M. Estimation of nuclear population from microtome sections. Anat Rec. 1946;94:239-247.
    • (1946) Anat Rec. , vol.94 , pp. 239-247
    • Abercrombie, M.1
  • 44
    • 0009690272 scopus 로고    scopus 로고
    • The independence of perimetry thresholds
    • Wall M, Wild J, eds. Amsterdam: Kugler Publications. In press
    • Harwerth RS, Smith EL. The independence of perimetry thresholds. In: Wall M, Wild J, eds. Perimetry Update 1998/1999. Amsterdam: Kugler Publications. In press.
    • Perimetry Update 1998/1999
    • Harwerth, R.S.1    Smith, E.L.2
  • 47
    • 0030025548 scopus 로고    scopus 로고
    • Study of central retinal ganglion cell loss in experimental glaucoma in monkey eyes
    • Desatnik H, Quigley HA, Glovinsky Y. Study of central retinal ganglion cell loss in experimental glaucoma in monkey eyes. J Glaucoma. 1996;5:46-53.
    • (1996) J Glaucoma , vol.5 , pp. 46-53
    • Desatnik, H.1    Quigley, H.A.2    Glovinsky, Y.3
  • 49
    • 0028821533 scopus 로고
    • Optic nerve axon count and axon diameter in patients with ocular hypertension and normal visual fields
    • Mikelberg FS, Yidegiligne HM, Schulzer M. Optic nerve axon count and axon diameter in patients with ocular hypertension and normal visual fields. Ophthalmology. 1995;102:342-348.
    • (1995) Ophthalmology , vol.102 , pp. 342-348
    • Mikelberg, F.S.1    Yidegiligne, H.M.2    Schulzer, M.3
  • 50
    • 0028304945 scopus 로고
    • Evidence for a variety of functional defects in glaucoma-suspect eyes
    • Sample PA, Madrid ME, Weinreb RN. Evidence for a variety of functional defects in glaucoma-suspect eyes. J Glaucoma. 1994; 3(suppl):S5-S17.
    • (1994) J Glaucoma , vol.3 , Issue.SUPPL.
    • Sample, P.A.1    Madrid, M.E.2    Weinreb, R.N.3
  • 51
    • 0028307409 scopus 로고
    • Selective versus nonselective losses in glaucoma
    • Johnson CA. Selective versus nonselective losses in glaucoma. J Glaucoma. 1994;3(suppl):S32-S44.
    • (1994) J Glaucoma , vol.3 , Issue.SUPPL.
    • Johnson, C.A.1
  • 52
    • 0028864556 scopus 로고
    • Association between quantitative nerve fiber layer measurement and visual field loss in glaucoma
    • Weinreb RN, Shakba S, Sample PA. Association between quantitative nerve fiber layer measurement and visual field loss in glaucoma. Am J Ophthalmol. 1995;120:732-738.
    • (1995) Am J Ophthalmol. , vol.120 , pp. 732-738
    • Weinreb, R.N.1    Shakba, S.2    Sample, P.A.3
  • 53
    • 0031058190 scopus 로고    scopus 로고
    • Screening for glaucomatous visual field loss with frequency-doubling perimetry
    • Johnson CA, Samuels SJ. Screening for glaucomatous visual field loss with frequency-doubling perimetry. Invest Ophthalmol Vis Sci. 1997;38:413-425.
    • (1997) Invest Ophthalmol Vis Sci. , vol.38 , pp. 413-425
    • Johnson, C.A.1    Samuels, S.J.2
  • 54
    • 0030931708 scopus 로고    scopus 로고
    • Short-wavelength automated perimetry and motion automated perimetry in patients with glaucoma
    • Sample PA, Bosworth CF, Weinreb RN. Short-wavelength automated perimetry and motion automated perimetry in patients with glaucoma. Arch Ophthalmol. 1997;115:1129-1133.
    • (1997) Arch Ophthalmol. , vol.115 , pp. 1129-1133
    • Sample, P.A.1    Bosworth, C.F.2    Weinreb, R.N.3
  • 55
  • 56
    • 0009665110 scopus 로고    scopus 로고
    • Motion detection perimetry: Properties and results
    • Wall M, Heijl A, eds. Amsterdam: Kugler Publications
    • Wall M, Brito CF, Kutzko K. Motion detection perimetry: properties and results. In: Wall M, Heijl A, eds. Perimetry Update 1996/ 1997. Amsterdam: Kugler Publications; 1997:21-33.
    • (1997) Perimetry Update 1996/1997 , pp. 21-33
    • Wall, M.1    Brito, C.F.2    Kutzko, K.3
  • 57
    • 0023865522 scopus 로고
    • Chronic human glaucoma causing selectively greater loss of large optic nerve fibers
    • Quigley HA, Dunkelberger GR, Baginski TA, Green WR. Chronic human glaucoma causing selectively greater loss of large optic nerve fibers. Ophthalmology. 1988;95:357-363.
    • (1988) Ophthalmology , vol.95 , pp. 357-363
    • Quigley, H.A.1    Dunkelberger, G.R.2    Baginski, T.A.3    Green, W.R.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.