1
-
-
0036167173
-
Hydroxyapatite ceramic hip survey ceramic on ceramic bearrings
-
J.M. Buchanan. Hydroxyapatite ceramic hip survey ceramic on ceramic bearrings. Key Eng. Mater 212-218, 487 (2002).
-
(2002)
Key Eng. Mater.
, vol.212-218
, pp. 487
-
-
Buchanan, J.1
-
2
-
-
0028813516
-
Titanium as the material of choice for cementless femoral components in total hiparthroplasty
-
W.C. Head, D.J. Bauk, and R.H. Emerson: Titanium as the material of choice for cementless femoral components in total hiparthroplasty Clin. Orthop. 311, 85 (1995).
-
(1995)
Clin. Orthop.
, vol.311
, pp. 85
-
-
Head, W.C.1
Bauk, D.J.2
Emerson, R.H.3
-
3
-
-
0028363215
-
Complications of hiparthroplasty causing periprosthetic radiolucency on plain radiographs
-
S. Tigges, R.G. Stiles, and J.R. Roberson: Complications of hiparthroplasty causing periprosthetic radiolucency on plain radiographs. Am. J. Roentgenol. 162, 1387 (1994).
-
(1994)
Am. J. Roentgenol.
, vol.162
, pp. 1387
-
-
Tigges, S.1
Stiles, R.G.2
Roberson, J.R.3
-
4
-
-
1942500933
-
Regulation of osteoclast activity in peri-implant tissues
-
D.R. Haynes, T.N. Crotti, and H. Zreigat: Regulation of osteoclast activity in peri-implant tissues. Biomaterials 25, 4877 (2004).
-
(2004)
Biomaterials
, vol.25
, pp. 487
-
-
Haynes, D.R.1
Crotti, T.N.2
Zreigat, H.3
-
5
-
-
0031555495
-
Engineering the tissue which encapsulates subcutaneous implants: Diffusion properties
-
A. A. Sharkawy, B. Klitzman, G. A. Truskey, and W.M. Reichert: Engineering the tissue which encapsulates subcutaneous implants: Diffusion properties. J. Biomed. Mater. Res. 37, 401 (1997).
-
(1997)
J. Biomed. Mater. Res.
, vol.37
, pp. 401
-
-
Sharkawy, A.A.1
Klitzman, B.2
Truskey, G.A.3
Reichert, W.M.4
-
6
-
-
0029790827
-
Metal versus polyethylene wear particles in total hip replacements
-
P.F. Doorn, P.A. Campbell, and H.C. Amstutz: Metal versus polyethylene wear particles in total hip replacements. Clin Orthop. 329, S206 (1996).
-
(1996)
Clin Orthop.
, vol.329
-
-
Doorn, P.F.1
Campbell, P.A.2
Amstutz, H.C.3
-
7
-
-
0034782843
-
Adherent endotoxin on orthopedic wear particles stimulates cytokine production and osteoclast differentiation
-
Y.M. Bi, J.M. Seabold, S.G. Kaar, A.A. Ragab, V.M. Goldberg, J.M. Anderson, and E.M. Greenfield: Adherent endotoxin on orthopedic wear particles stimulates cytokine production and osteoclast differentiation. J. Bone Miner. Res. 16, 2082 (2001).
-
(2001)
J. Bone Miner. Res.
, vol.16
, pp. 2082
-
-
Bi, Y.M.1
Seabold, J.M.2
Kaar, S.G.3
Ragab, A.A.4
Goldberg, V.M.5
Anderson, J.M.6
Greenfield, E.M.7
-
8
-
-
0032763421
-
Cost analysis of revision total hip arthroplasty: A 5-year follow-up study
-
R.L. Barrack, J. Sawhney, J. Hsu, and R.H. Cofield: Cost analysis of revision total hip arthroplasty: A 5-year follow-up study. Clin. Orthop. 369, 175 (1999).
-
(1999)
Clin. Orthop.
, vol.369
, pp. 175
-
-
Barrack, R.L.1
Sawhney, J.2
Hsu, J.3
Cofield, R.H.4
-
9
-
-
0032723976
-
Bioactive ceramics: The effect of surface reactivity on bone formation and bone cell function
-
P. Ducheyne and Q. Qiu: Bioactive ceramics: The effect of surface reactivity on bone formation and bone cell function. Biomaterials 20, 2287 (1999).
-
(1999)
Biomaterials
, vol.20
, pp. 2287
-
-
Ducheyne, P.1
Qiu, Q.2
-
10
-
-
0034214546
-
Bioceramics - Yesterday, today, tomorrow
-
V.A. Dubok: Bioceramics - yesterday, today, tomorrow. Powder Metall Metal Ceram. 39, 381 (2000).
-
(2000)
Powder Metall. Metal. Ceram.
, vol.39
, pp. 381
-
-
Dubok, V.A.1
-
11
-
-
8144220495
-
Current concepts review -hydroxyapatite-coated prostheses in total hip and knee arthroplasty
-
J. Dumbleton and M.T. Manley: Current concepts review -hydroxyapatite-coated prostheses in total hip and knee arthroplasty. J. Bone Joint Surg.- Am. 86, 2526 (2004).
-
(2004)
J. Bone Joint Surg.- Am.
, vol.86
, pp. 2526
-
-
Dumbleton, J.1
Manley, M.T.2
-
12
-
-
1842560233
-
Applications of plasma coatings in artificial joints: An overview
-
H. Liang, B. Shi, A. Fairchild, and T. Cale: Applications of plasma coatings in artificial joints: an overview. Vacuum 73, 317 (2004).
-
(2004)
Vacuum
, vol.73
, pp. 317
-
-
Liang, H.1
Shi, B.2
Fairchild, A.3
Cale, T.4
-
13
-
-
0036836438
-
Surface characteristics and dissolution behavior of plasma-sprayed hydroxyapatite coating
-
L.M. Sun, C.C. Berndt, K.A. Khor, H.N. Cheang, and K.A. Gross: Surface characteristics and dissolution behavior of plasma-sprayed hydroxyapatite coating. J. Biomed. Mater. Res. 62, 228 (2002).
-
(2002)
J. Biomed. Mater. Res.
, vol.62
, pp. 228
-
-
Sun, L.M.1
Berndt, C.C.2
Khor, K.A.3
Cheang, H.N.4
Gross, K.A.5
-
14
-
-
1642266364
-
Plasma-sprayed hydroxyapatite plus titania composite bond coat for hydroxyapatite testing on titanium substrate
-
Y.P. Lu, M.S. Li, S.T. Li, Z.G. Wang, and R.F. Zhu: Plasma-sprayed hydroxyapatite plus titania composite bond coat for hydroxyapatite testing on titanium substrate. Biomaterials 28, 4393 (2004).
-
(2004)
Biomaterials
, vol.28
, pp. 4393
-
-
Lu, Y.P.1
Li, M.S.2
Li, S.T.3
Wang, Z.G.4
Zhu, R.F.5
-
15
-
-
0034801327
-
Material fundamentals and clinical performance of plasma-sprayed hydroxyapatite coatings: A review
-
L.M. Sun, C.C. Berndt, K.A. Gross, and A. Kucuk: Material fundamentals and clinical performance of plasma-sprayed hydroxyapatite coatings: A review. J. Biomed. Mater. Res. 58, 570 (2001).
-
(2001)
J. Biomed. Mater. Res.
, vol.58
, pp. 570
-
-
Sun, L.M.1
Berndt, C.C.2
Gross, K.A.3
Kucuk, A.4
-
16
-
-
29144529270
-
Mitochondrial viability and apoptosis induced by aluminum, mercuric mercury and methylmercury in cell lines of neural origin
-
T. Toimela and H. Tahti: Mitochondrial viability and apoptosis induced by aluminum, mercuric mercury and methylmercury in cell lines of neural origin. Arch. Toxicol. 18, 765 (2004).
-
(2004)
Arch. Toxicol.
, vol.18
, pp. 765
-
-
Toimela, T.1
Tahti, H.2
-
17
-
-
0028332820
-
Studies on nickel-induced inhibition of fibroblast growth
-
M.H. Grant, C. Nugent, and R. Bertrand: Studies on nickel-induced inhibition of fibroblast growth. Toxicol. In Vitro 8, 191 (1994).
-
(1994)
Toxicol. In Vitro
, vol.8
, pp. 191
-
-
Grant, M.H.1
Nugent, C.2
Bertrand, R.3
-
18
-
-
1642302150
-
Damage to F-actin and cell death induced by chromium VI and nickel in primary monolayer cultures of rat hepatocytes
-
M. Gunaratnam and M.H. Grant: Damage to F-actin and cell death induced by chromium VI and nickel in primary monolayer cultures of rat hepatocytes. Toxicol. In Vitro 18, 245 (2004).
-
(2004)
Toxicol. In Vitro
, vol.18
, pp. 245
-
-
Gunaratnam, M.1
Grant, M.H.2
-
21
-
-
0031453696
-
Hydroxyapatite coatings: A comparative study between plasma-spray and pulsed laser deposition techniques
-
F.J. Garcia Sanz, M.B. Mayor, J.L. Arias, J. Pou, B. Leon, and M. Perez Amor: Hydroxyapatite coatings: A comparative study between plasma-spray and pulsed laser deposition techniques. J. Mater. Sci. Mater. Med. 8, 861 (1997).
-
(1997)
J. Mater. Sci. Mater. Med.
, vol.8
, pp. 861
-
-
Garcia Sanz, F.J.1
Mayor, M.B.2
Arias, J.L.3
Pou, J.4
Leon, B.5
Perez Amor, M.6
-
22
-
-
0002630067
-
Pulsed laser deposition of hydoxylapatite thin-films on Ti-6Al-4V
-
C.M. Cotell, D.B. Chrisey, K.S. Grabowski, J.A. Sprague, and C.R. Gossett: Pulsed laser deposition of hydoxylapatite thin-films on Ti-6Al-4V, J. Appl. Biomater. 3, 87 (1992).
-
(1992)
J. Appl. Biomater.
, vol.3
, pp. 87
-
-
Cotell, C.M.1
Chrisey, D.B.2
Grabowski, K.S.3
Sprague, J.A.4
Gossett, C.R.5
-
23
-
-
0027905133
-
Pulsed-laser deposition and processing of biocompatible hydroxylapatite thin films
-
C.M. Cotell: Pulsed-laser deposition and processing of biocompatible hydroxylapatite thin films. Appl. Surf. Sci. 69, 140 (1993).
-
(1993)
Appl. Surf. Sci.
, vol.69
, pp. 140
-
-
Cotell, C.M.1
-
24
-
-
9344243580
-
Nanostructured ceramics in medical devices: Applications and prospects
-
R.J. Narayan, P.N. Kumta, C. Sfeir, D.H. Lee, D. Olton, and D.W. Choi: Nanostructured ceramics in medical devices: Applications and prospects. JOM 56, 38 (2004).
-
(2004)
JOM
, vol.56
, pp. 38
-
-
Narayan, R.J.1
Kumta, P.N.2
Sfeir, C.3
Lee, D.H.4
Olton, D.5
Choi, D.W.6
-
25
-
-
0034160230
-
Atomic structure, electrical properties, and infrared range optical properties of diamondlike-carbon films containing foreign atoms prepared by pulsed laser deposition
-
Q. Wei, J. Sankar, A.K. Sharma, S. Oktyabrsky, J. Narayan, and R.J. Narayan: Atomic structure, electrical properties, and infrared range optical properties of diamondlike-carbon films containing foreign atoms prepared by pulsed laser deposition. J. Mater. Res. 15, 633 (2000).
-
(2000)
J. Mater. Res.
, vol.15
, pp. 633
-
-
Wei, Q.1
Sankar, J.2
Sharma, A.K.3
Oktyabrsky, S.4
Narayan, J.5
Narayan, R.J.6
-
26
-
-
0037165927
-
Diamond-like amorphous carbon
-
J. Robertson: Diamond-like amorphous carbon, Mater. Sci. Eng. Rep. 37, 129 (2002).
-
(2002)
Mater. Sci. Eng. Rep.
, vol.37
, pp. 129
-
-
Robertson, J.1
-
27
-
-
1542316667
-
Preparation of diamond-like carbon polymer hybrid films using filtered pulsed arc discharge method
-
A. Antilla, V.M. Tiainen, M. Kiuru, E. Alakoski, and K. Arstila: Preparation of diamond-like carbon polymer hybrid films using filtered pulsed arc discharge method. Surf. Eng. 19, 425 (2003).
-
(2003)
Surf. Eng.
, vol.19
, pp. 425
-
-
Antilla, A.1
Tiainen, V.M.2
Kiuru, M.3
Alakoski, E.4
Arstila, K.5
-
28
-
-
0034225656
-
Synthesis of diamond-like-carbon films with superlow friction and wear properties
-
A. Erdemir, O.L. Eryilmaz, and G. Fenske: Synthesis of diamond-like-carbon films with superlow friction and wear properties. J. Vac. Sci. Technol. A 18, 1987 (2000).
-
(2000)
J. Vac. Sci. Technol. A
, vol.18
, pp. 1987
-
-
Erdemir, A.1
Eryilmaz, O.L.2
Fenske, G.3
-
29
-
-
0348014820
-
Reduction of wear in total hip replacement prostheses by amorphous diamond coatings
-
R. Lappalainen, M. Selenius, A. Anttila, Y.T. Konttinen, and S.S. Santavirta: Reduction of wear in total hip replacement prostheses by amorphous diamond coatings. J. Biomed. Mater. Res. Part B - Appl. Biomater. 66B, 410 (2003).
-
(2003)
J. Biomed. Mater. Res. Part B - Appl. Biomater.
, vol.66 B
, pp. 410
-
-
Lappalainen, R.1
Selenius, M.2
Anttila, A.3
Konttinen, Y.T.4
Santavirta, S.S.5
-
30
-
-
0035728743
-
In vitro and in vivo investigations into the biocompatibility of diamond-like carbon (DLC) coatings for orthopedic applications
-
M. Allen, B. Myer, and N. Rushton: In vitro and in vivo investigations into the biocompatibility of diamond-like carbon (DLC) coatings for orthopedic applications. J. Biomed. Mater. Res. 58, 319 (2001).
-
(2001)
J. Biomed. Mater. Res.
, vol.58
, pp. 319
-
-
Allen, M.1
Myer, B.2
Rushton, N.3
-
31
-
-
0026061113
-
Biocompatibility of diamond-like carbon coating
-
L.A. Thomson, F.C. Law, N. Rushton, and J. Franks: Biocompatibility of diamond-like carbon coating, Biomaterials 12, 37 (1991).
-
(1991)
Biomaterials
, vol.12
, pp. 37
-
-
Thomson, L.A.1
Law, F.C.2
Rushton, N.3
Franks, J.4
-
32
-
-
0036132132
-
Adhesion, cytoskeletal architecture and activation status of primary human macrophages on a diamond-like carbon coated surface
-
S. Linder, W. Pinkowski, and M. Aepfelbacher: Adhesion, cytoskeletal architecture and activation status of primary human macrophages on a diamond-like carbon coated surface. Biomaterials 23, 767 (2002).
-
(2002)
Biomaterials
, vol.23
, pp. 767
-
-
Linder, S.1
Pinkowski, W.2
Aepfelbacher, M.3
-
33
-
-
0040962639
-
Haemocompatibility of DLC and TiC-TiN interlayers on titanium
-
M.I. Jones, I.R. McColl, D.M. Grant, K.G. Parker, and T.L. Parker: Haemocompatibility of DLC and TiC-TiN interlayers on titanium. Diamond Relat. Mater. 8, 457 (1999).
-
(1999)
Diamond Relat. Mater.
, vol.8
, pp. 457
-
-
Jones, M.I.1
McColl, I.R.2
Grant, D.M.3
Parker, K.G.4
Parker, T.L.5
-
35
-
-
0034250566
-
Structural and tribological characteristics of diamond-like carbon films deposited by pulsed laser ablation
-
A.K. Sharma, R.J. Narayan, J. Narayan, and K. Jagannadham: Structural and tribological characteristics of diamond-like carbon films deposited by pulsed laser ablation. Mater. Sci. Eng. B-Solid State Mater. Adv. Technol. 77, 139 (2000).
-
(2000)
Mater. Sci. Eng. B-Solid State Mater. Adv. Technol.
, vol.77
, pp. 139
-
-
Sharma, A.K.1
Narayan, R.J.2
Narayan, J.3
Jagannadham, K.4
-
36
-
-
0028883591
-
Quantitative near-edge structure-analysis of diamond-like carbon in the electron-microscope using a 2-window method
-
J. Bruley, D.B. Williams, J.J. Cuomo, and D.P. Pappas: Quantitative near-edge structure-analysis of diamond-like carbon in the electron-microscope using a 2-window method. J. Microsc. Oxford 180, 22 (1995).
-
(1995)
J. Microsc. Oxford
, vol.180
, pp. 22
-
-
Bruley, J.1
Williams, D.B.2
Cuomo, J.J.3
Pappas, D.P.4
-
38
-
-
0032403157
-
Hydroxyapatite-polyethylene composites for bone substitution: Effects of ceramic particle size and morphology
-
M. Wang, R. Joseph, and W. Bonfield: Hydroxyapatite-polyethylene composites for bone substitution: Effects of ceramic particle size and morphology. Biomaterials 19, 2357 (1998).
-
(1998)
Biomaterials
, vol.19
, pp. 2357
-
-
Wang, M.1
Joseph, R.2
Bonfield, W.3
-
39
-
-
0000854187
-
Formation of bilayer Ni-SiC composite coatings by electrodeposition
-
S.K. Kim and H.J. Yoo: Formation of bilayer Ni-SiC composite coatings by electrodeposition. Surf. Coatings Technol. 108, 564 (1998).
-
(1998)
Surf. Coatings Technol.
, vol.108
, pp. 564
-
-
Kim, S.K.1
Yoo, H.J.2
-
40
-
-
0030198228
-
Nanocrystals as stoichiometric reagents with unique surface chemistry
-
K.J. Klabunde, J. Stark, O. Koper, C. Mohs, D.G. Park, S. Decker, Y. Jiang, I. Lagadic, and D.J. Zhang: Nanocrystals as stoichiometric reagents with unique surface chemistry. J. Phys. Chem. 100, 12142 (1996).
-
(1996)
J. Phys. Chem.
, vol.100
, pp. 12142
-
-
Klabunde, K.J.1
Stark, J.2
Koper, O.3
Mohs, C.4
Park, D.G.5
Decker, S.6
Jiang, Y.7
Lagadic, I.8
Zhang, D.J.9
-
41
-
-
2342440651
-
Increased osteoblast adhesion on nanophase metals: Ti, Ti6Al4V, and CoCrMo
-
T.J. Webster and J.U. Ejiofor: Increased osteoblast adhesion on nanophase metals: Ti, Ti6Al4V, and CoCrMo. Biomaterials 25, 4731 (2004).
-
(2004)
Biomaterials
, vol.25
, pp. 4731
-
-
Webster, T.J.1
Ejiofor, J.U.2
-
42
-
-
0037708471
-
Micro- and nanotesting of calcium phosphate coatings produced by pulsed laser deposition
-
J.L Arias, M.B. Mayor, J. Pou, Y. Leng, B. Leon, and M. Perez-Amor: Micro- and nanotesting of calcium phosphate coatings produced by pulsed laser deposition. Biomaterials 24, 3403 (2003).
-
(2003)
Biomaterials
, vol.24
, pp. 3403
-
-
Arias, J.1
Mayor, M.B.2
Pou, J.3
Leng, Y.4
Leon, B.5
Perez-Amor, M.6
-
43
-
-
0026241285
-
Microscratch testing to characterize the adhesion of thin-layers
-
C. Juliaschmutz and H.E. Hintermann: Microscratch testing to characterize the adhesion of thin-layers. Surf. Coatings Technol. 48, 1 (1991).
-
(1991)
Surf. Coatings Technol.
, vol.48
, pp. 1
-
-
Juliaschmutz, C.1
Hintermann, H.E.2
|