메뉴 건너뛰기




Volumn 66, Issue 1, 2003, Pages 410-413

Reduction of Wear in Total Hip Replacement Prostheses by Amorphous Diamond Coatings

Author keywords

Amorphous diamond; Hip simulator; Total hip replacement; Wear resistance

Indexed keywords

COATINGS; DEBRIS; DIAMONDS; LUBRICATION; PLASMA ARC CUTTING; SIMULATORS; WEAR OF MATERIALS;

EID: 0348014820     PISSN: 00219304     EISSN: None     Source Type: Journal    
DOI: 10.1002/jbm.b.10026     Document Type: Article
Times cited : (92)

References (16)
  • 1
    • 0003817623 scopus 로고    scopus 로고
    • Prognosis of total hip replacement. Revision and re-revision rate in THR: A revision-risk study of 148,359 primary operations
    • Malchau H, Herberts P. Prognosis of total hip replacement. Revision and re-revision rate in THR: A revision-risk study of 148,359 primary operations. The Swedish National Hip Arthroplasty Registry; 1998. pp 1-16.
    • (1998) The Swedish National Hip Arthroplasty Registry , pp. 1-16
    • Malchau, H.1    Herberts, P.2
  • 2
    • 0025874154 scopus 로고
    • Metal wear and tissue response in failed titanium alloy total hip replacements
    • Witt JD, Swann M. Metal wear and tissue response in failed titanium alloy total hip replacements. J Bone Joint Surg 1991; 73B:559-563.
    • (1991) J Bone Joint Surg , vol.73 B , pp. 559-563
    • Witt, J.D.1    Swann, M.2
  • 3
    • 0027244880 scopus 로고
    • Characteristics of metal and ceramic total hip bearing surfaces and their effect on long-term ultra high molecular weight polyethylene wear
    • Davidson J. Characteristics of metal and ceramic total hip bearing surfaces and their effect on long-term ultra high molecular weight polyethylene wear. Clin Orthop 1993;294:361-378.
    • (1993) Clin Orthop , vol.294 , pp. 361-378
    • Davidson, J.1
  • 4
    • 0031727764 scopus 로고    scopus 로고
    • Metal release in patients who had a primary total hip arthroplasty
    • Jacobs JJ et al. Metal release in patients who had a primary total hip arthroplasty. J Bone Joint Surg 1998;80A:1447-1458.
    • (1998) J Bone Joint Surg , vol.80 A , pp. 1447-1458
    • Jacobs, J.J.1
  • 7
    • 0031336524 scopus 로고    scopus 로고
    • Superior attachment of high-quality hydrogen-free amorphous diamond films to solid materials
    • Anttila A, Lappalainen R, Tiainen VM, Hakovirta M. Superior attachment of high-quality hydrogen-free amorphous diamond films to solid materials. Adv Mater 1997;9:1161-1164.
    • (1997) Adv Mater , vol.9 , pp. 1161-1164
    • Anttila, A.1    Lappalainen, R.2    Tiainen, V.M.3    Hakovirta, M.4
  • 8
    • 0029388375 scopus 로고
    • Energies of carbon plasma beams in the deposition of diamond-like coatings with the pulsed arc discharge method
    • Salo J, Lappalainen R, Anttila. A. Energies of carbon plasma beams in the deposition of diamond-like coatings with the pulsed arc discharge method. Appl Phys 1995;61A:353-355.
    • (1995) Appl Phys , vol.61 A , pp. 353-355
    • Salo, J.1    Lappalainen, R.2    Anttila, A.3
  • 9
    • 0346661509 scopus 로고    scopus 로고
    • Procedure and apparatus for the coating of materials by means of a pulsating plasma beam. U.S. Patent No. 5 078 848; 1992
    • Anttila A, Hirvonen JP, Koskinen J. Procedure and apparatus for the coating of materials by means of a pulsating plasma beam. U.S. Patent No. 5 078 848; 1992.
    • Anttila, A.1    Hirvonen, J.P.2    Koskinen, J.3
  • 10
    • 0029325023 scopus 로고
    • High adhesion of diamondlike films achieved by the pulsed arc discharge method
    • Anttila A, Salo J, Lappalainen R. High adhesion of diamondlike films achieved by the pulsed arc discharge method. Mater Lett 1995;24:153-156.
    • (1995) Mater Lett , vol.24 , pp. 153-156
    • Anttila, A.1    Salo, J.2    Lappalainen, R.3
  • 11
    • 0037792515 scopus 로고    scopus 로고
    • Role of polyethylene oxidation and consolidation defects in cup performance
    • Gómez-Barrena E et al. Role of polyethylene oxidation and consolidation defects in cup performance. Clin Orthop 1998; 352:105-117.
    • (1998) Clin Orthop , vol.352 , pp. 105-117
    • Gómez-Barrena, E.1
  • 12
    • 0029809897 scopus 로고    scopus 로고
    • Metal on metal total hip replacement workshop consensus document
    • Amstutz HC et al. Metal on metal total hip replacement workshop consensus document. Clin Orthop (Suppl) 1996;329: S297-S303.
    • (1996) Clin Orthop (Suppl) , vol.329
    • Amstutz, H.C.1
  • 13
    • 0028453984 scopus 로고
    • The effects of micromotion and particulate materials on tissue differentiation. Bone chamber studies in rabbits
    • Goodman SB. The effects of micromotion and particulate materials on tissue differentiation. Bone chamber studies in rabbits, Acta Orthop Scand 1994;65 Suppl 258:1-43.
    • (1994) Acta Orthop Scand , vol.65 , Issue.SUPPL. 258 , pp. 1-43
    • Goodman, S.B.1
  • 15
    • 0031816246 scopus 로고    scopus 로고
    • In vitro, in vivo, and tissue retrieval studies on particulate debris
    • Goodman SB, Lind M, Song Y, Smith RL. In vitro, in vivo, and tissue retrieval studies on particulate debris. Clin Orthop 1999; 352:25-34.
    • (1999) Clin Orthop , vol.352 , pp. 25-34
    • Goodman, S.B.1    Lind, M.2    Song, Y.3    Smith, R.L.4
  • 16
    • 0344369901 scopus 로고    scopus 로고
    • Quantitative assessment of activity in joint replacement patients
    • Schmalzried TP et al. Quantitative assessment of activity in joint replacement patients. Trans Orthop Res Soc 1997;22:284-285.
    • (1997) Trans Orthop Res Soc , vol.22 , pp. 284-285
    • Schmalzried, T.P.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.