메뉴 건너뛰기




Volumn 25, Issue 7, 2005, Pages 561-565

Longitudinal intrafascicular electrodes in collection and analysis of sensory signals of the peripheral nerve in a feline model

Author keywords

[No Author keywords available]

Indexed keywords

POLITEF;

EID: 27744563094     PISSN: 07381085     EISSN: None     Source Type: Journal    
DOI: 10.1002/micr.20159     Document Type: Article
Times cited : (10)

References (35)
  • 1
    • 0021895425 scopus 로고
    • Free toe transfer to the forearm stump following wrist amputation: A current alternative to the Krukenberg operation
    • Vilkki SK. Free toe transfer to the forearm stump following wrist amputation: a current alternative to the Krukenberg operation. Handchir Mikrochir Plast Chir 1985;17:92-97.
    • (1985) Handchir Mikrochir Plast Chir , vol.17 , pp. 92-97
    • Vilkki, S.K.1
  • 2
    • 0019396433 scopus 로고
    • "Hand reconstruction" by autotransplantation of toes
    • Chen ZW, Wang Y. "Hand reconstruction" by autotransplantation of toes. Chin J Surg 1981;19:7-9.
    • (1981) Chin J Surg , vol.19 , pp. 7-9
    • Chen, Z.W.1    Wang, Y.2
  • 3
    • 0022397229 scopus 로고
    • Method of reconstructing thumb, index and/or middle finger for digitless hands
    • Yu ZJ, He HG. Method of reconstructing thumb, index and/or middle finger for digitless hands. Chin Med J [Engl] 1985;98:863-867.
    • (1985) Chin Med J [Engl] , vol.98 , pp. 863-867
    • Yu, Z.J.1    He, H.G.2
  • 4
    • 0021603171 scopus 로고
    • The Krukenberg procedure: A method of treatment for unilateral anomalies of the upper limb in Chinese children
    • Chan KM, Ma GF, Cheng JC, Leung PC. The Krukenberg procedure: a method of treatment for unilateral anomalies of the upper limb in Chinese children. J Hand Surg [Am] 1984;9:548-551.
    • (1984) J Hand Surg [Am] , vol.9 , pp. 548-551
    • Chan, K.M.1    Ma, G.F.2    Cheng, J.C.3    Leung, P.C.4
  • 8
    • 0031931581 scopus 로고    scopus 로고
    • Experimental development of a sensory control system for an upper limb myoelectric prosthesis with cosmetic covering
    • Tura A, Lamberti C, Davalli A, Sacchetti R. Experimental development of a sensory control system for an upper limb myoelectric prosthesis with cosmetic covering. J Rehabil Res Dev 1998;35:14-26.
    • (1998) J Rehabil Res Dev , vol.35 , pp. 14-26
    • Tura, A.1    Lamberti, C.2    Davalli, A.3    Sacchetti, R.4
  • 9
    • 0037627472 scopus 로고    scopus 로고
    • Control of multifunctional prosthetic hands by processing the electromyographic signal
    • Zecca M, Micera S, Carrozza MC, Dario P. Control of multifunctional prosthetic hands by processing the electromyographic signal. Crit Rev Biomed Eng 2002;30:459-485.
    • (2002) Crit Rev Biomed Eng , vol.30 , pp. 459-485
    • Zecca, M.1    Micera, S.2    Carrozza, M.C.3    Dario, P.4
  • 13
    • 0038503570 scopus 로고    scopus 로고
    • Longitudinally implanted intrafascicular electrodes for stimulating and recording fascicular physioelectrical signals in the sciatic nerve of rabbits
    • Zheng XJ, Zhang J, Chen TY, Chen Z. Longitudinally implanted intrafascicular electrodes for stimulating and recording fascicular physioelectrical signals in the sciatic nerve of rabbits. Microsurgery 2003;23:268-273.
    • (2003) Microsurgery , vol.23 , pp. 268-273
    • Zheng, X.J.1    Zhang, J.2    Chen, T.Y.3    Chen, Z.4
  • 15
    • 0034792999 scopus 로고    scopus 로고
    • Neuroprostheses for the upper extremity
    • Keith MW. Neuroprostheses for the upper extremity. Microsurgery 2001;21:256-263.
    • (2001) Microsurgery , vol.21 , pp. 256-263
    • Keith, M.W.1
  • 16
    • 0036800309 scopus 로고    scopus 로고
    • Percutaneous Freehand system intramuscular electrode placement
    • Hausman MR, Masters JE. Percutaneous Freehand system intramuscular electrode placement. J Hand Surg [Br] 2002:27:465-469.
    • (2002) J Hand Surg [Br] , vol.27 , pp. 465-469
    • Hausman, M.R.1    Masters, J.E.2
  • 17
    • 3142743126 scopus 로고    scopus 로고
    • Residual function in peripheral nerve stumps of amputees: Implications for neural control of artificial limbs
    • Dhillon GS, Lawrence SM, Hutchinson DT, Horch KW. Residual function in peripheral nerve stumps of amputees: implications for neural control of artificial limbs. J Hand Surg [Am] 2004;29: 605-615.
    • (2004) J Hand Surg [Am] , vol.29 , pp. 605-615
    • Dhillon, G.S.1    Lawrence, S.M.2    Hutchinson, D.T.3    Horch, K.W.4
  • 19
    • 2442555963 scopus 로고    scopus 로고
    • Neuroprosthetics of the upper extremity-clinical application in spinal cord injury and future perspectives
    • Rupp R, Gerner HJ. Neuroprosthetics of the upper extremity-clinical application in spinal cord injury and future perspectives. Biomed Tech (Berlin) 2004;49:93-98.
    • (2004) Biomed Tech (Berlin) , vol.49 , pp. 93-98
    • Rupp, R.1    Gerner, H.J.2
  • 20
    • 21344494850 scopus 로고
    • Sense of feel for lower-limb amputees: A phase-one study
    • Sabolich JA, Ortega GM. Sense of feel for lower-limb amputees: a phase-one study. J Prosthet Orthotics 1994;6:36-41.
    • (1994) J Prosthet Orthotics , vol.6 , pp. 36-41
    • Sabolich, J.A.1    Ortega, G.M.2
  • 22
    • 0030008272 scopus 로고    scopus 로고
    • Non-invasive measurement of the input-output properties of peripheral nerve stimulating electrodes
    • Grill WM, Mortimer JT. Non-invasive measurement of the input-output properties of peripheral nerve stimulating electrodes. J Neurosci Methods 1996;65:43-50.
    • (1996) J Neurosci Methods , vol.65 , pp. 43-50
    • Grill, W.M.1    Mortimer, J.T.2
  • 24
    • 0029294523 scopus 로고
    • A neuromuscular stimulation selectivity of multiple-contact nerve cuff electrode arrays
    • Sweeney JD, Crawford NR, Brandon T. A neuromuscular stimulation selectivity of multiple-contact nerve cuff electrode arrays. Med Biol Eng Comput 1995;33:418-425.
    • (1995) Med Biol Eng Comput , vol.33 , pp. 418-425
    • Sweeney, J.D.1    Crawford, N.R.2    Brandon, T.3
  • 25
    • 0027588996 scopus 로고
    • Selective stimulation of peripheral nerve fibers using dual intrafascicular electrodes
    • Yoshida K, Horch K. Selective stimulation of peripheral nerve fibers using dual intrafascicular electrodes. IEEE Trans Biomed Eng 1993;40:492-494.
    • (1993) IEEE Trans Biomed Eng , vol.40 , pp. 492-494
    • Yoshida, K.1    Horch, K.2
  • 26
    • 0031868320 scopus 로고    scopus 로고
    • Protocol for microneurography with concentric needle electrodes
    • Hallin RG, Wu G. Protocol for microneurography with concentric needle electrodes. Brain Res Brain Res Protoc 1998;2: 120-132.
    • (1998) Brain Res Brain Res Protoc , vol.2 , pp. 120-132
    • Hallin, R.G.1    Wu, G.2
  • 27
    • 0031105670 scopus 로고    scopus 로고
    • A slowly penetrating interfascicular nerve electrode for selective activation of peripheral nerves
    • Tyler DJ, Durand DM. A slowly penetrating interfascicular nerve electrode for selective activation of peripheral nerves. IEEE Trans Rehabil Eng 1997;5:51-61.
    • (1997) IEEE Trans Rehabil Eng , vol.5 , pp. 51-61
    • Tyler, D.J.1    Durand, D.M.2
  • 28
    • 0034001259 scopus 로고    scopus 로고
    • A multielectrode array for intrafascicular recording and stimulation in sciatic nerve of cats
    • Branner A, Normann RA. A multielectrode array for intrafascicular recording and stimulation in sciatic nerve of cats. Brain Res Bull 2000;51:293-306.
    • (2000) Brain Res Bull , vol.51 , pp. 293-306
    • Branner, A.1    Normann, R.A.2
  • 29
    • 0035068673 scopus 로고    scopus 로고
    • Selective stimulation of cat sciatic nerve using an array of varying-length microelectrodes
    • Branner A, Stein RB, Normann RA. Selective stimulation of cat sciatic nerve using an array of varying-length microelectrodes. J Neurophysiol 2001;85:1585-1594.
    • (2001) J Neurophysiol , vol.85 , pp. 1585-1594
    • Branner, A.1    Stein, R.B.2    Normann, R.A.3
  • 30
    • 0024320175 scopus 로고
    • An intrafascicular electrode for recording of action potentials in peripheral nerves
    • Malagodi MS, Horch KW, Schoenberg AA. An intrafascicular electrode for recording of action potentials in peripheral nerves. Ann Biomed Eng 1989;17:397-410.
    • (1989) Ann Biomed Eng , vol.17 , pp. 397-410
    • Malagodi, M.S.1    Horch, K.W.2    Schoenberg, A.A.3
  • 31
    • 27744431952 scopus 로고    scopus 로고
    • Electric prosthesis controlled by nerve signals in amputation stump of a volunteer
    • Jia XF, Chen TY, Chen ZW. Electric prosthesis controlled by nerve signals in amputation stump of a volunteer. Chin J Phys Med Rehabil 2004;26:20-22.
    • (2004) Chin J Phys Med Rehabil , vol.26 , pp. 20-22
    • Jia, X.F.1    Chen, T.Y.2    Chen, Z.W.3
  • 32
    • 27744498589 scopus 로고    scopus 로고
    • Experimental study on harvesting nerve-signals in the human amputation stump of the upper arm
    • Jia XF, Chen ZW, Chen TY. Experimental study on harvesting nerve-signals in the human amputation stump of the upper arm. Chin J Orthop Trauma 2003;5:165-167.
    • (2003) Chin J Orthop Trauma , vol.5 , pp. 165-167
    • Jia, X.F.1    Chen, Z.W.2    Chen, T.Y.3
  • 34
    • 0030088097 scopus 로고    scopus 로고
    • Closed-loop control of ankle position using muscle afferent feedback with functional neuromuscular stimulation
    • Yoshida K, Horch K. Closed-loop control of ankle position using muscle afferent feedback with functional neuromuscular stimulation. IEEE Biomed Eng 1996;43:167-176.
    • (1996) IEEE Biomed Eng , vol.43 , pp. 167-176
    • Yoshida, K.1    Horch, K.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.